cmmCpuLoad15MinAlert
| .1.3.6.1.4.1.36673.100.1.3.1.1 | Trap to send information for 15min alert threshold and
CPU Utilisation |
cmmCpuCoreUtilHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.10 | Trap to send information for CPU utilization in alert condition. |
cmmSysPSUInputCurrentLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.100 | Set when PSU input current reached low alert threshold value. |
cmmSysPSUInputCurrentHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.101 | Set when PSU input current reached high critical threshold value. |
cmmSysPSUInputCurrentLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.102 | Set when PSU input current reached low critical threshold value. |
cmmSysPSUInputCurrentHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.103 | Set when PSU input current recovered from high alert threshold. |
cmmSysPSUInputCurrentLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.104 | Set when PSU input current recovered from low alert threshold. |
cmmSysPSUInputCurrentHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.105 | Set when PSU input current recovered from high critical threshold. |
cmmSysPSUInputCurrentLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.106 | Set when PSU input current recovered from low critical threshold. |
cmmSysPSUOutputCurrentHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.107 | Set when PSU output current reached high alert threshold value. |
cmmSysPSUOutputCurrentLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.108 | Set when PSU output current reached low alert threshold value. |
cmmSysPSUOutputCurrentHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.109 | Set when PSU output current reached high critical threshold value. |
cmmCpuCoreUtilHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.11 | Trap to send information for CPU utilization after critical recovery. |
cmmSysPSUOutputCurrentLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.110 | Set when PSU output current reached low critical threshold value. |
cmmSysPSUOutputCurrentHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.111 | Set when PSU output current recovered from high alert threshold. |
cmmSysPSUOutputCurrentLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.112 | Set when PSU output current recovered from low alert threshold. |
cmmSysPSUOutputCurrentHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.113 | Set when PSU output current recovered from high critical threshold. |
cmmSysPSUOutputCurrentLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.114 | Set when PSU output current recovered from low critical threshold. |
cmmSysPSUTemperature1HighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.115 | Set when PSU temperature1 reached high alert threshold value. |
cmmSysPSUTemperature1LowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.116 | Set when PSU temperature1 reached low alert threshold value. |
cmmSysPSUTemperature1HighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.117 | Set when PSU temperature1 reached high critical threshold value. |
cmmSysPSUTemperature1LowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.118 | Set when PSU temperature1 reached low critical threshold value. |
cmmSysPSUTemperature1HighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.119 | Set when PSU temperature1 recovered from high alert threshold. |
cmmCpuCoreUtilHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.12 | Trap to send information for CPU utilization after alert recovery. |
cmmSysPSUTemperature1LowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.120 | Set when PSU temperature1 recovered from low alert threshold. |
cmmSysPSUTemperature1HighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.121 | Set when PSU temperature1 recovered from high critical threshold. |
cmmSysPSUTemperature1LowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.122 | Set when PSU temperature1 recovered from low critical threshold. |
cmmSysPSUTemperature2HighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.123 | Set when PSU temperature2 reached high alert threshold value. |
cmmSysPSUTemperature2LowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.124 | Set when PSU temperature2 reached low alert threshold value. |
cmmSysPSUTemperature2HighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.125 | Set when PSU temperature2 reached high critical threshold value. |
cmmSysPSUTemperature2LowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.126 | Set when PSU temperature2 reached low critical threshold value. |
cmmSysPSUTemperature2HighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.127 | Set when PSU temperature2 recovered from high alert threshold. |
cmmSysPSUTemperature2LowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.128 | Set when PSU temperature2 recovered from low alert threshold. |
cmmSysPSUTemperature2HighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.129 | Set when PSU temperature2 recovered from high critical threshold. |
cmmSysPSUTemperature2LowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.130 | Set when PSU temperature2 recovered from low critical threshold. |
cmmSysPSUTemperature3HighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.131 | Set when PSU temperaturer3 reached high alert threshold value. |
cmmSysPSUTemperature3LowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.132 | Set when PSU temperature3 reached low alert threshold value. |
cmmSysPSUTemperature3HighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.133 | Set when PSU temperature3 reached high critical threshold value. |
cmmSysPSUTemperature3LowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.134 | Set when PSU temperature3 reached low critical threshold value. |
cmmSysPSUTemperature3HighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.135 | Set when PSU temperature3 recovered from high alert threshold. |
cmmSysPSUTemperature3LowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.136 | Set when PSU temperature3 recovered from low alert threshold. |
cmmSysPSUTemperature3HighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.137 | Set when PSU temperature3 recovered from high critical threshold. |
cmmSysPSUTemperature3LowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.138 | Set when PSU temperature3 recovered from low critical threshold. |
cmmFanTrayInsertedNotify
| .1.3.6.1.4.1.36673.100.1.3.1.141 | Set when fan tray is inserted |
cmmFanTrayRemovedCritical
| .1.3.6.1.4.1.36673.100.1.3.1.142 | Set when fan tray is Removed |
cmmFanTrayFaultyCritical
| .1.3.6.1.4.1.36673.100.1.3.1.143 | Set when Given Fan Tray Faulty. |
cmmFanTrayRecovered
| .1.3.6.1.4.1.36673.100.1.3.1.144 | Set when Given Fan Tray is recovered. |
cmmFanTrayStallCritical
| .1.3.6.1.4.1.36673.100.1.3.1.145 | Set when Given Fan Tray Stalled. |
cmmFanTrayStallRecovered
| .1.3.6.1.4.1.36673.100.1.3.1.146 | Set when Given Fan Tray is recovered from stall. |
cmmFanRPMMinNotify
| .1.3.6.1.4.1.36673.100.1.3.1.147 | Set when fan RPM set to its minimum value. |
cmmFanRPMMaxCritical
| .1.3.6.1.4.1.36673.100.1.3.1.148 | Set when fan RPM set to its maximum value. |
cmmFanRPMDecreasedNotify
| .1.3.6.1.4.1.36673.100.1.3.1.149 | Set when fan RPM decreased from previous RPM |
cmmFanRPMIncreasedNotify
| .1.3.6.1.4.1.36673.100.1.3.1.150 | Set when fan RPM increased from previous RPM |
cmmCpuLoad5MinAlert
| .1.3.6.1.4.1.36673.100.1.3.1.2 | Trap to send information for 5min alert threshold and
CPU Utilisation |
cmmRamUsageRisingCritical
| .1.3.6.1.4.1.36673.100.1.3.1.21 | Trap to send when RAM usage exceeds Critical Threshold |
cmmRamUsageRisingAlert
| .1.3.6.1.4.1.36673.100.1.3.1.22 | Trap to send when RAM usage exceeds Alert Threshold |
cmmRamUsageCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.23 | Trap to send when RAM usage recovers from Critical Condition |
cmmRamUsageAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.24 | Trap to send when RAM usage recovers under Alert threshold. |
cmmHardDiskUsageRisingCritical
| .1.3.6.1.4.1.36673.100.1.3.1.25 | Trap to send when Hard Disk usage exceeds critical threshold. |
cmmHardDiskUsageRisingAlert
| .1.3.6.1.4.1.36673.100.1.3.1.26 | Trap to send when Hard Disk usage exceeds alert threshold. |
cmmHardDiskUsageCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.27 | Trap to send when Hard Disk usage recovers under critical threshold. |
cmmHardDiskUsageAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.28 | Trap to send when Hard Disk usage recovers under alert threshold. |
cmmSysHardDiskRemainLifeRisingAlert
| .1.3.6.1.4.1.36673.100.1.3.1.29 | Trap to send when Hard Disk Remain life reached below the Alert threshold. |
cmmCpuLoad1MinCritical
| .1.3.6.1.4.1.36673.100.1.3.1.3 | Trap to send information for 1min critical level threshold and
CPU Utilisation |
cmmSysHardDiskRemainLifeRisingCritical
| .1.3.6.1.4.1.36673.100.1.3.1.30 | Trap to send when Hard Disk Remain life reached below the Critical threshold. |
cmmSysHardDiskAvailableReservedSpaceAlert
| .1.3.6.1.4.1.36673.100.1.3.1.31 | Trap to send when Hard Disk Available Reserved Space reached below the Alert threshold. |
cmmSysHardDiskAvailableReservedSpaceCritical
| .1.3.6.1.4.1.36673.100.1.3.1.32 | Trap to send when Hard Disk Available Reserved Space reached below the Critical threshold. |
cmmSysHardDiskReallocSectorsCountAlert
| .1.3.6.1.4.1.36673.100.1.3.1.33 | Trap to send when Hard Disk Realloced sector count increments by 10. |
cmmSysHardDiskUncorrectableSectorCountCritical
| .1.3.6.1.4.1.36673.100.1.3.1.34 | Trap to send when Hard Disk Uncorrectable sector count increments by 1. |
cmmSysHardDiskActivityMonitoringReadAlert
| .1.3.6.1.4.1.36673.100.1.3.1.35 | Trap to send when Hard Disk activity violates read threshold. |
cmmSysHardDiskActivityMonitoringReadRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.36 | Trap to send when Hard Disk read activity violation recovers. |
cmmSysHardDiskActivityMonitoringWriteAlert
| .1.3.6.1.4.1.36673.100.1.3.1.37 | Trap to send when Hard Disk activity violates write threshold. |
cmmSysHardDiskActivityMonitoringWriteRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.38 | Trap to send when Hard Disk write activity violation recovers. |
cmmSysHardDiskStorageStatusNotification
| .1.3.6.1.4.1.36673.100.1.3.1.39 | Trap to send when Hard Disk Storage Status (EOL) Change |
cmmCpuLoad1MinAlert
| .1.3.6.1.4.1.36673.100.1.3.1.4 | Trap to send information for 1min alert level threshold and
CPU Utilisation |
cmmTemperatureLowEmergency
| .1.3.6.1.4.1.36673.100.1.3.1.41 | Set when Temperature will be below lower threshold for sensor |
cmmTemperatureHighEmergency
| .1.3.6.1.4.1.36673.100.1.3.1.42 | Set when Temperature will be above threshold for sensor |
cmmTemperatureLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.43 | Set when Temperature is nearing low emergency condition for sensor |
cmmTemperatureHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.44 | Set when Temperature is nearing high emergency condition for sensor |
cmmTemperatureLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.45 | Set when Temperature has reached low alert condition for sensor |
cmmTemperatureHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.46 | Set when Temperature has reached high alert condition for sensor |
cmmTemperatureHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.47 | Set when Temperature is recovered to normal range from critical level high for sensor |
cmmTemperatureLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.48 | Set when Temperature is recovered to normal range from critical level low for sensor |
cmmTemperatureHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.49 | Set when Temperature is recovered to normal range from alert level high for sensor |
cmmCpuLoad1MinCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.5 | Trap to send information for CPU usage recovered from Critical Condition |
cmmTemperatureLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.50 | Set when Temperature is recovered to normal range from alert level low for sensor |
cmmCpuLoad15MinAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.6 | Trap to send information for CPU usage recovered from 15 min Alert Condition |
cmmPsuInsertedNotify
| .1.3.6.1.4.1.36673.100.1.3.1.61 | Set when Power supply unit is inserted |
cmmPsuRemovedCritical
| .1.3.6.1.4.1.36673.100.1.3.1.62 | Set when Power supply unit is Removed |
cmmPsuAcFailedCritical
| .1.3.6.1.4.1.36673.100.1.3.1.63 | Set when Power supply unit has no input power |
cmmPsuAcRecover
| .1.3.6.1.4.1.36673.100.1.3.1.64 | Set when Power supply unit input is restored |
cmmPsu12vPgFailedCritical
| .1.3.6.1.4.1.36673.100.1.3.1.65 | Set when Power supply unit has no output power |
cmmPsu12vPgRecover
| .1.3.6.1.4.1.36673.100.1.3.1.66 | Set when Power supply unit has restored output |
cmmSysPSUInputVoltageHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.67 | Set when PSU input voltage reached high alert threshold value. |
cmmSysPSUInputVoltageLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.68 | Set when PSU input voltage reached low alert threshold value. |
cmmSysPSUInputVoltageHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.69 | Set when PSU input voltage reached high critical threshold value. |
cmmCpuLoad5MinAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.7 | Trap to send information for CPU usage recovered from 5 min Alert Condition |
cmmSysPSUInputVoltageLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.70 | Set when PSU input power reached low alert threshold value. |
cmmSysPSUInputVoltageHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.71 | Set when PSU input voltage is recovered from high alert threshold. |
cmmSysPSUInputVoltageLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.72 | Set when PSU input voltage is recovered from low alert threshold. |
cmmSysPSUInputVoltageHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.73 | Set when PSU input voltage is recovered from high critical threshold. |
cmmSysPSUInputVoltageLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.74 | Set when PSU input power is recovered from low alert threshold. |
cmmSysPSUOutputVoltageHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.75 | Set when PSU output voltage reached high alert threshold value. |
cmmSysPSUOutputVoltageLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.76 | Set when PSU output voltage reached low alert threshold value. |
cmmSysPSUOutputVoltageHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.77 | Set when PSU output voltage reached high critical threshold value. |
cmmSysPSUOutputVoltageLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.78 | Set when PSU output voltage reached low critical threshold value. |
cmmSysPSUOutputVoltageHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.79 | Set when PSU output voltage recovered from high alert threshold. |
cmmCpuLoad1MinAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.8 | Trap to send information for CPU usage recovered from 15 min Alert Condition |
cmmSysPSUOutputVoltageLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.80 | Set when PSU output voltage recovered from low alert threshold. |
cmmSysPSUOutputVoltageHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.81 | Set when PSU output voltage recovered from high critical threshold. |
cmmSysPSUOutputVoltageLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.82 | Set when PSU output voltage recovered from low critical threshold. |
cmmSysPSUInputPowerHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.83 | Set when PSU input power reached high alert threshold value. |
cmmSysPSUInputPowerLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.84 | Set when PSU input power reached low alert threshold value. |
cmmSysPSUInputPowerHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.85 | Set when PSU input power reached high critical threshold value. |
cmmSysPSUInputPowerLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.86 | Set when PSU input power reached low critical threshold value. |
cmmSysPSUInputPowerHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.87 | Set when PSU input power recovered from high alert threshold. |
cmmSysPSUInputPowerLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.88 | Set when PSU input power recovered from low alert threshold. |
cmmSysPSUInputPowerHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.89 | Set when PSU input power recovered from high critical threshold. |
cmmCpuCoreUtilHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.9 | Trap to send information for CPU utilization in critical condition. |
cmmSysPSUInputPowerLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.90 | Set when PSU input power recovered from low critical threshold. |
cmmSysPSUOutputPowerHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.91 | Set when PSU output power reached high alert threshold value. |
cmmSysPSUOutputPowerLowAlert
| .1.3.6.1.4.1.36673.100.1.3.1.92 | Set when PSU output power reached low alert threshold value. |
cmmSysPSUOutputPowerHighCritical
| .1.3.6.1.4.1.36673.100.1.3.1.93 | Set when PSU output power reached high critical threshold value. |
cmmSysPSUOutputPowerLowCritical
| .1.3.6.1.4.1.36673.100.1.3.1.94 | Set when PSU output power reached low critical threshold value. |
cmmSysPSUOutputPowerHighAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.95 | Set when PSU output power recovered from high alert threshold. |
cmmSysPSUOutputPowerLowAlertRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.96 | Set when PSU output power recovered from low alert threshold. |
cmmSysPSUOutputPowerHighCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.97 | Set when PSU output power recovered from high critical threshold. |
cmmSysPSUOutputPowerLowCriticalRecovery
| .1.3.6.1.4.1.36673.100.1.3.1.98 | Set when PSU output power recovered from low critical threshold. |
cmmSysPSUInputCurrentHighAlert
| .1.3.6.1.4.1.36673.100.1.3.1.99 | Set when PSU input current reached high alert threshold value. |
cmmTransAlertTempHigh
| .1.3.6.1.4.1.36673.100.1.3.2.1 | Set when internal temperature of transceiver exceeds high alarm level. |
cmmTransAlertSnrHigh
| .1.3.6.1.4.1.36673.100.1.3.2.101 | Notification sent when SNR falls above alert max value. |
cmmTransAlertSnrLow
| .1.3.6.1.4.1.36673.100.1.3.2.102 | Notification sent when SNR falls below alert min value. |
cmmTransCriticalSnrHigh
| .1.3.6.1.4.1.36673.100.1.3.2.103 | Notification sent when SNR falls above critical max value. |
cmmTransCriticalSnrLow
| .1.3.6.1.4.1.36673.100.1.3.2.104 | Notification sent when SNR falls below critical min value. |
cmmTransNotifyTransceiverSnrRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.105 | Set when SNR of transceiver is recovered from SNR fault. |
cmmTransAlertVoltageHigh
| .1.3.6.1.4.1.36673.100.1.3.2.11 | Set when internal supply voltage of transceiver exceeds high alarm level. |
cmmTransAlertresIsiHigh
| .1.3.6.1.4.1.36673.100.1.3.2.111 | Notification sent when residual-isi falls above alert max value. |
cmmTransAlertresIsiLow
| .1.3.6.1.4.1.36673.100.1.3.2.112 | Notification sent when residual-isi falls below alert min value. |
cmmTransCriticalResIsiHigh
| .1.3.6.1.4.1.36673.100.1.3.2.113 | Notification sent when residual-isi falls above critical max value. |
cmmTransCriticalResIsiLow
| .1.3.6.1.4.1.36673.100.1.3.2.114 | Notification sent when residual-isi falls below critical min value. |
cmmTransNotifyTransceiverResIsiRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.115 | Set when residual-isi of transceiver is recovered from residual-isi fault. |
cmmTransAlertVoltageLow
| .1.3.6.1.4.1.36673.100.1.3.2.12 | Set when internal supply voltage of transceiver is below low alarm level. |
cmmTransAlertLvlTranHigh
| .1.3.6.1.4.1.36673.100.1.3.2.121 | Notification sent when level transition falls above alert max value. |
cmmTransAlertLvlTranLow
| .1.3.6.1.4.1.36673.100.1.3.2.122 | Notification sent when level transition falls below alert min value. |
cmmTransCriticalLvlTranHigh
| .1.3.6.1.4.1.36673.100.1.3.2.123 | Notification sent when level transition falls above critical max value. |
cmmTransCriticalLvlTranLow
| .1.3.6.1.4.1.36673.100.1.3.2.124 | Notification sent when level transition falls below critical min value. |
cmmTransNotifyTransceiverLvlTranRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.125 | Set when level transition of transceiver is recovered from level transition fault. |
cmmTransCriticalVoltageHigh
| .1.3.6.1.4.1.36673.100.1.3.2.13 | Set when internal supply voltage of transceiver exceeds high Critical level. |
cmmTransAlertTecCurrErrHigh
| .1.3.6.1.4.1.36673.100.1.3.2.131 | Notification sent when thermo-electric cooler current falls above alert max value. |
cmmTransAlertTecCurrErrLow
| .1.3.6.1.4.1.36673.100.1.3.2.132 | Notification sent when thermo-electric cooler current falls below alert min value. |
cmmTransCriticalTecCurrErrHigh
| .1.3.6.1.4.1.36673.100.1.3.2.133 | Notification sent when thermo-electric cooler current falls above critical max value. |
cmmTransCriticalTecCurrErrLow
| .1.3.6.1.4.1.36673.100.1.3.2.134 | Notification sent when thermo-electric cooler current falls below critical min value. |
cmmTransNotifyTransceiverTecCurrErrRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.135 | Set when thermo-electric cooler current of transceiver is recovered thermo-electric cooler current fault. |
cmmTransCriticalVoltageLow
| .1.3.6.1.4.1.36673.100.1.3.2.14 | Set when internal supply voltage of transceiver is below low Critical level |
cmmTransAlertLaserTempValHigh
| .1.3.6.1.4.1.36673.100.1.3.2.141 | Notification sent when laser temperature falls above crictical max value. |
cmmTransAlertLaserTempValLow
| .1.3.6.1.4.1.36673.100.1.3.2.142 | Notification sent when laser temperature falls below alert min value. |
cmmTransCriticalLaserTempValHigh
| .1.3.6.1.4.1.36673.100.1.3.2.143 | Notification sent when laser temperature falls above critical max value. |
cmmTransCriticalLaserTempValLow
| .1.3.6.1.4.1.36673.100.1.3.2.144 | Notification sent when laser temperature falls below critical min value. |
cmmTransNotifyTransceiverLaserTempRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.145 | Set when laser temperature of transceiver is recovered from temperature fault. |
cmmTranAlertTransceiverPortRxLoss
| .1.3.6.1.4.1.36673.100.1.3.2.146 | Set when RX_LOSS is detected on transceiver ports |
cmmTransNotifyTransceiverPortRxLossRecovery
| .1.3.6.1.4.1.36673.100.1.3.2.147 | Set when RX_LOSS is recovered on transceiver ports |
cmmTransNotifyTransceiverVoltRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.15 | Set when Trasceiver is recovered from voltage fault. |
cmmTransAlertTempLow
| .1.3.6.1.4.1.36673.100.1.3.2.2 | Set when internal temperature of transceiver is below low alarm level. |
cmmTransAlertBiasHigh
| .1.3.6.1.4.1.36673.100.1.3.2.21 | Set when TX Bias current of transceiver exceeds high alarm level. |
cmmTransAlertBiasLow
| .1.3.6.1.4.1.36673.100.1.3.2.22 | Set when TX Bias current of transceiver is below low alarm level. |
cmmTransCriticalBiashigh
| .1.3.6.1.4.1.36673.100.1.3.2.23 | Set when TX Bias current of transceiver exceeds high Critical level. |
cmmTransCriticalBiasLow
| .1.3.6.1.4.1.36673.100.1.3.2.24 | Set when TX Bias current of transceiver is below low Critical level. |
cmmTransNotifyTransceiverBiasRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.25 | Set when Trasceiver is recovered from Bias current fault. |
cmmTransCriticalTempHigh
| .1.3.6.1.4.1.36673.100.1.3.2.3 | Set when internal temperature of transceiver exceeds high Critical level. |
cmmTransAlertRxPowerHigh
| .1.3.6.1.4.1.36673.100.1.3.2.31 | Set when Received Power of transceiver exceeds high alarm level. |
cmmTransAlertRxPowerLow
| .1.3.6.1.4.1.36673.100.1.3.2.32 | Set when Received Power of transceiver is below low alarm level. |
cmmTransCriticalRxPowerHigh
| .1.3.6.1.4.1.36673.100.1.3.2.33 | Set when Received Power of transceiver exceeds high Critical level. |
cmmTransCriticalRxPowerLow
| .1.3.6.1.4.1.36673.100.1.3.2.34 | Set when Received Power of transceiver is below low Critical level. |
cmmTransNotifyTransceiverRxPowRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.35 | Set when Trasceiver is recovered from Rx power fault. |
cmmTransCriticalTempLow
| .1.3.6.1.4.1.36673.100.1.3.2.4 | Set when internal temperature of transceiver is below low Critical level |
cmmTransAlertTxPowerHigh
| .1.3.6.1.4.1.36673.100.1.3.2.41 | Set when Transferred Power of transceiver exceeds high alarm level. |
cmmTransAlertTxPowerLow
| .1.3.6.1.4.1.36673.100.1.3.2.42 | Set when Transferred Power of transceiver is below low alarm level. |
cmmTransCriticalTxPowerHigh
| .1.3.6.1.4.1.36673.100.1.3.2.43 | Set when Transferred Power of transceiver exceeds high Critical level. |
cmmTransCriticalTxPowerLow
| .1.3.6.1.4.1.36673.100.1.3.2.44 | Set when Transferred Power of transceiver is below low Critical level. |
cmmTransNotifyTransceiverTxPowRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.45 | Set when Trasceiver is recovered from Tx Power fault. |
cmmTransNotifyTransceiverTempRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.5 | Set when Trasceiver is recovered from temperature fault. |
cmmTransNotifyTransceiverInserted
| .1.3.6.1.4.1.36673.100.1.3.2.51 | Set when Trasceiver is inserted. |
cmmTransCriticalTransceiverRemoved
| .1.3.6.1.4.1.36673.100.1.3.2.52 | Set when Trasceiver is removed. |
cmmTransCriticalFaultyTransceiverInserted
| .1.3.6.1.4.1.36673.100.1.3.2.53 | Set when Trasceiver is inserted and failed to read transceiver EEPROM information. |
cmmCriticalIncompatibleTransceiverPresence
| .1.3.6.1.4.1.36673.100.1.3.2.54 | Set when Incompatible Trasceiver is Present |
cmmNotifyIncompatibleTransceiverRecovery
| .1.3.6.1.4.1.36673.100.1.3.2.55 | Set when Incompatible Trasceiver is Removed |
cmmTransXFPAlertVoltage2High
| .1.3.6.1.4.1.36673.100.1.3.2.61 | Set when the volatge of the second available supply of the XFP transceiver exceeds the high warning level. |
cmmTransXFPAlertVoltage2Low
| .1.3.6.1.4.1.36673.100.1.3.2.62 | Set when the volatge of the second available supply of the XFP transceiver is below the low warning level. |
cmmTransXFPCriticalVoltage2High
| .1.3.6.1.4.1.36673.100.1.3.2.63 | Set when the volatge of the second available supply of the XFP transceiver exceeds the high critical level. |
cmmTransXFPCriticalVoltage2Low
| .1.3.6.1.4.1.36673.100.1.3.2.64 | Set when the volatge of the second available supply of the XFP transceiver is below the low critical level |
cmmTransNotifyTransceiverXFPVolt2Recovered
| .1.3.6.1.4.1.36673.100.1.3.2.65 | Set when the volatge of the second available supply of the XFP transceiver is recovered from the voltage fault. |
cmmTransFrequencyErrorHighAlert
| .1.3.6.1.4.1.36673.100.1.3.2.66 | Set when Frequency error of transceiver exceeds high alert level. |
cmmTransFrequencyErrorLowAlert
| .1.3.6.1.4.1.36673.100.1.3.2.67 | Set when Frequency error of transceiver is below low alert level. |
cmmTransFrequencyErrorHighCritical
| .1.3.6.1.4.1.36673.100.1.3.2.68 | Set when Frequency error of transceiver exceeds high critical level. |
cmmTransFrequencyErrorLowCritical
| .1.3.6.1.4.1.36673.100.1.3.2.69 | Set when Frequency error of transceiver is below low critical level. |
cmmTransFrequencyErrorRecovery
| .1.3.6.1.4.1.36673.100.1.3.2.70 | Set when Frequency error is recovered to normal range. |
cmmTransWavelengthErrorHighAlert
| .1.3.6.1.4.1.36673.100.1.3.2.71 | Set when Wavelength error of transceiver exceeds high alert level. |
cmmTransWavelengthErrorLowAlert
| .1.3.6.1.4.1.36673.100.1.3.2.72 | Set when Wavelength error of transceiver is below low alert level. |
cmmTransWavelengthErrorHighCritical
| .1.3.6.1.4.1.36673.100.1.3.2.73 | Set when Wavelength error of transceiver exceeds high critical level. |
cmmTransWavelengthErrorLowCritical
| .1.3.6.1.4.1.36673.100.1.3.2.74 | Set when Wavelength error of transceiver is below low critical level. |
cmmTransWavelengthErrorRecovery
| .1.3.6.1.4.1.36673.100.1.3.2.75 | Set when Wavelength error is recovered to normal range. |
cmmTransTECFaultCritical
| .1.3.6.1.4.1.36673.100.1.3.2.76 | Set when TEC Fault has occurred on the transceiver. |
cmmTransTECFaultRecovery
| .1.3.6.1.4.1.36673.100.1.3.2.77 | Set when the transceiver has recovered from TEC Fault. |
cmmTransAlertPreFecBerErrHigh
| .1.3.6.1.4.1.36673.100.1.3.2.81 | Notification sent when FEC bit error rate falls above alert max value. |
cmmTransAlertPreFecBerErrLow
| .1.3.6.1.4.1.36673.100.1.3.2.82 | Notification sent when FEC bit error rate falls below alert min value. |
cmmTransCriticalPreFecBerErrHigh
| .1.3.6.1.4.1.36673.100.1.3.2.83 | Notification sent when FEC bit error rate falls above critical max value. |
cmmTransCriticalPreFecBerErrLow
| .1.3.6.1.4.1.36673.100.1.3.2.84 | Notification sent when FEC bit error rate falls below critical min value. |
cmmTransNotifyTransceiverPreFecBerRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.85 | Set when FEC bit error rate of transceiver is recovered from BER fault. |
cmmTransAlertUncorrectedBerHigh
| .1.3.6.1.4.1.36673.100.1.3.2.91 | Notification sent when Frame Error Rate falls above alert max value. |
cmmTransAlertUncorrectedBerLow
| .1.3.6.1.4.1.36673.100.1.3.2.92 | Notification sent when Frame Error Rate falls below alert min value. |
cmmTransCriticalUncorrectedBerHigh
| .1.3.6.1.4.1.36673.100.1.3.2.93 | Notification sent when Frame Error Rate falls above critical max value. |
cmmTransCriticalUncorrectedBerLow
| .1.3.6.1.4.1.36673.100.1.3.2.94 | Notification sent when Frame Error Rate falls below critical min value. |
cmmTransNotifyTransceiverUncorrectedBerRecovered
| .1.3.6.1.4.1.36673.100.1.3.2.95 | Set when Frame Error Rate transceiver is recovered from uncorrected BER fault. |