.1.3.6.1.4.1.5205.2.34.1.1.4.2 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841AccountTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841AccountTable'
This is a list of SW0657841AccountEntry. The numbers of entries are given by
the value of sw0657841AccountNumber.
sw0657841AccountEntry row .1.3.6.1.4.1.5205.2.34.1.1.4.2.1
This is the Entry(s) for account information.
Column Syntax OID
sw0657841AccountIndexThis is the index of the account entry.Integer32
Constraints:
range: 1-5
.1.3.6.1.4.1.5205.2.34.1.1.4.2.1.1
sw0657841AccountAuthorizationThis is the authorization of the account entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.1.4.2.1.2
sw0657841AccountNameThis is the username of the account entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.1.4.2.1.3
sw0657841AccountPasswordThis is the password of the account entry. The return value is always '********'.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.1.4.2.1.4
.1.3.6.1.4.1.5205.2.34.1.2.4 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841TrapHostTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841TrapHostTable'
A list of trap host entry. The numbers of entries are given by the value of sw0657841TrapHostNumber.
sw0657841TrapHostEntry row .1.3.6.1.4.1.5205.2.34.1.2.4.1
This is the entry information for trap host.
Column Syntax OID
sw0657841TrapHostIndexThe index of the trap host entry.Integer32
Constraints:
range: 1-6
.1.3.6.1.4.1.5205.2.34.1.2.4.1.1
sw0657841TrapHostIPThis is the IP of the trap host.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.5205.2.34.1.2.4.1.2
sw0657841TrapHostPortThis is the receiving-port number of the trap host.Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5205.2.34.1.2.4.1.3
sw0657841TrapHostCommunityThe community name for the trap PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.2.4.1.4
.1.3.6.1.4.1.5205.2.34.1.3.1.2 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841EventTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841EventTable'
This is a list of alarm event entry. The numbers of entries are given by the value of sw0657841EventNumber.
sw0657841EventEntry row .1.3.6.1.4.1.5205.2.34.1.3.1.2.1
This is the entry information for alarm event.
Column Syntax OID
sw0657841EventIndexThis is the index of the alarm event entry.Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.5205.2.34.1.3.1.2.1.1
sw0657841EventNameThis is the alarm event name.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.3.1.2.1.2
sw0657841EventSendEmailSend email when alarm event is triggered.Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.3.1.2.1.3
sw0657841EventSendTrapSend trap when alarm event is triggered.Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.3.1.2.1.4
.1.3.6.1.4.1.5205.2.34.1.3.2.5 · 1 row entry · 2 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841EmailUserTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841EmailUserTable'
This is a list of email user entry. The numbers of entries are given by the value of sw0657841EmailUserNumber.
sw0657841EmailUserEntry row .1.3.6.1.4.1.5205.2.34.1.3.2.5.1
This is the Entry information for email user entry.
Column Syntax OID
sw0657841EmailUserIndexThis is the index of the email user entry.Integer32
Constraints:
range: 1-6
.1.3.6.1.4.1.5205.2.34.1.3.2.5.1.1
sw0657841EmailUserAddressThis is the email address of the email user entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.3.2.5.1.2
.1.3.6.1.4.1.5205.2.34.1.7.5 · 1 row entry · 2 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841LogTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841LogTable'
This is a list of log entry. The numbers of entries are given by the value of sw0657841LogNumber.
sw0657841LogEntry row .1.3.6.1.4.1.5205.2.34.1.7.5.1
This is the Entry information for system log.
Column Syntax OID
sw0657841LogIndexThis is the index of the log entry.Integer32
Constraints:
range: 1-120
.1.3.6.1.4.1.5205.2.34.1.7.5.1.1
sw0657841LogEventThis is the detail information of the log entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.7.5.1.2
.1.3.6.1.4.1.5205.2.34.1.9.1.2 · 1 row entry · 7 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841PortStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841PortStatusTable'
This is a list of port status entry. The numbers of entries are given by the value of sw0657841PortStatusNumber.
sw0657841PortStatusEntry row .1.3.6.1.4.1.5205.2.34.1.9.1.2.1
This is the entry(s) for port status information.
Column Syntax OID
sw0657841PortStatusIndexThis is the index of the port status entry.Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.1
sw0657841PortStatusMediaThe port media type of the port status entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.2
sw0657841PortStatusLinkThis is the port link of the port status entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.3
sw0657841PortStatusSpdDpxThis is the speed/duplex of the port status entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.4
sw0657841PortStatusFlwCtrlRxThis is the Rx flow control of the port status entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.5
sw0657841PortStatusFlwCtrlTxThis is the Tx flow control of the port status entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.6
sw0657841PortStatuDescriptionThis is the description of port.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.1.2.1.7
.1.3.6.1.4.1.5205.2.34.1.9.2.2 · 1 row entry · 6 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841PortConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841PortConfTable'
This is a list of port configuration entry. The numbers of entries are given by the value of sw0657841PortConfNumber.
sw0657841PortConfEntry row .1.3.6.1.4.1.5205.2.34.1.9.2.2.1
This is the Entry(s) for port configuration information.
Column Syntax OID
sw0657841PortConfIndexThis is the index of the port configuration entry.Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.5205.2.34.1.9.2.2.1.1
sw0657841PortConfPortStateThis is the port state of the port configuration entry.
0 - disabled.
1 - enabled.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.9.2.2.1.2
sw0657841PortConfSpdDpxThis is the speed/duplex of the port configuration entry.
0 - auto.
1 - 10M/Half.
2 - 10M/Full.
3 - 100M/Half.
4 - 100M/Full.
5 - 1G/Full.
Integer32r/w
Constraints:
range: 0-5
.1.3.6.1.4.1.5205.2.34.1.9.2.2.1.3
sw0657841PortConfFlwCtrlThis is the flow control of the port configuration entry.
0 - disabled.
1 - enabled.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.9.2.2.1.4
sw0657841PortConfExcessiveCollisionMode0 - Discard.
1 - Restart.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.9.2.2.1.5
sw0657841PortConfDescriptionThis is the description of port.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.2.2.1.6
.1.3.6.1.4.1.5205.2.34.1.9.3.2 · 1 row entry · 16 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841SFPInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841SFPInfoTable'
A list of sfp info entry. The numbers of entries are given by the value of sw0657841SFPInfoNumber.
sw0657841SFPInfoEntry row .1.3.6.1.4.1.5205.2.34.1.9.3.2.1
Entry(s) for SFP information.
Column Syntax OID
sw0657841SFPInfoIndexThe index of the sfp info entry.Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.1
sw0657841SFPConnectorTypeGet connector type of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.2
sw0657841SFPFiberTypeGet fiber type of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.3
sw0657841SFPWavelengthGet tx central wavelength of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.4
sw0657841SFPBaudRateGet baud rate of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.5
sw0657841SFPVendorOUIGet vendor OUI of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.6
sw0657841SFPVendorNameGet vendor name of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.7
sw0657841SFPVendorPNGet vendor part number of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.8
sw0657841SFPVendorRevGet vendor revision number of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.9
sw0657841SFPVendorSNGet vendor serial number of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.10
sw0657841SFPDateCodeGet data code of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.11
sw0657841SFPTemperatureGet current temperature of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.12
sw0657841SFPVccGet current internal supply voltage of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.13
sw0657841SFPTxBiasGet current TX Bias of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.14
sw0657841SFPTxPWRGet current TX output power of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.15
sw0657841SFPRxPWRGet current Received Power of the sfp.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.9.3.2.1.16
.1.3.6.1.4.1.5205.2.34.1.10.2 · 1 row entry · 3 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841MirroredPortsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841MirroredPortsTable'
This is a list of port configuration entry. The numbers of entries are given by the value of sw0657841PortConfNumber.
sw0657841MirroredPortsEntry row .1.3.6.1.4.1.5205.2.34.1.10.2.1
This is the Entry(s) for port configuration information.
Column Syntax OID
sw0657841MirroredPortIndexThis is the index of the mirrored port.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.10.2.1.1
sw0657841MirroredPortSrouceEnable0 - disabled.
1 - enabled.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.10.2.1.2
sw0657841MirroredPortDestinationEnable0 - disabled.
1 - enabled.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.10.2.1.3
.1.3.6.1.4.1.5205.2.34.1.11.2 · 1 row entry · 2 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841MaxPktLenConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841MaxPktLenConfTable'
This is a list of Max. packet length entry. The numbers of entries are given by the value of sw0657841MaxPktLenPortNumber.
sw0657841MaxPktLenConfEntry row .1.3.6.1.4.1.5205.2.34.1.11.2.1
Entry(s) for Max. packet length information.
Column Syntax OID
sw0657841MaxPktLenConfIndexThis is the index of the Max. packet length entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.11.2.1.1
sw0657841MaxPktLenConfSettingGet/Set the Max. packet length.
The Max. packet length is 1518~9600.
Integer32r/w
Constraints:
range: 1518-9600
.1.3.6.1.4.1.5205.2.34.1.11.2.1.2
.1.3.6.1.4.1.5205.2.34.1.12.2 · 1 row entry · 3 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841LoopDetectedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841LoopDetectedTable'
A list of loop detected entry. The numbers of entries are given by the value of sw0657841LoopDetectedNumber.
sw0657841LoopDetectedEntry row .1.3.6.1.4.1.5205.2.34.1.12.2.1
Entry(s) for loop detected information.
Column Syntax OID
sw0657841LoopDetectedfIndexThe index of the loop detected entry.Integer32
Constraints:
range: 1-2147483647
.1.3.6.1.4.1.5205.2.34.1.12.2.1.1
sw0657841LoopDetectedPortThe state of the loop detected entry.
0 - disabled.
1 - enabled.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.12.2.1.2
sw0657841LoopDetectedLockedPortThe current status of the loop detected port.
Get:
0 - unlocked
1 - locked due to the loop condition
Set:
0 - unlock the port
1 - do nothing
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.12.2.1.3
.1.3.6.1.4.1.5205.2.34.1.13.3 · 1 row entry · 7 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841ManagementSecurityTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841ManagementSecurityTable'
This is a list of SW0657841ManagementSecurityEntry. The numbers of entries are given by ManagementSecurityNumber.
sw0657841ManagementSecurityEntry row .1.3.6.1.4.1.5205.2.34.1.13.3.1
This is the Entry(s) for Management Security configuration information.
Column Syntax OID
sw0657841ManagementSecurityIndexThis is the index of the management policy configuration entry.Integer32
Constraints:
range: 1-64
.1.3.6.1.4.1.5205.2.34.1.13.3.1.1
sw0657841ManagementSecurityNameThis is the username of the management security entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.13.3.1.2
sw0657841ManagementSecurityIpRangeThis is the ip range of the management security entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.13.3.1.3
sw0657841ManagementSecurityIncomigPortThis is the incoming port of the management security entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.13.3.1.4
sw0657841ManagementSecurityAccessType0 - any.
1 - http.
2 - telnet
3 - snmp
SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.13.3.1.5
sw0657841ManagementSecurityAction0 - deny.
1 - accept.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.13.3.1.6
sw0657841ManagementSecurityEntryAction1 - active.
2 - notInService.
3 - delete.
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.13.3.1.7
.1.3.6.1.4.1.5205.2.34.1.14.2.3 · 1 row entry · 7 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841TagBaseVlanGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841TagBaseVlanGroupTable'
A list of tagged-based VLAN group entry. The number of entries can be taked from sw0657841TagBaseVlanNumber.
sw0657841TagBaseVlanGroupEntry row .1.3.6.1.4.1.5205.2.34.1.14.2.3.1
This is the entry(s) for tagged-based VLAN group configuration.
Column Syntax OID
sw0657841TagBaseVlanVidThis is the index of the tagged-based VLAN group configuration entry.Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.1
sw0657841TagBaseVlanNameThis is the name of the VLAN.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.2
sw0657841TagBaseVlanIgmpProxyTo support IGMP proxy in this VLAN.
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.3
sw0657841TagBaseVlanPrivateVlanTo apply the port isolation configuration.
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.4
sw0657841TagBaseVlanGvrpThis VLAN can be propagated by gvrp.
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.5
sw0657841TagBaseVlanMemberPortThe member port(s) of this VLAN.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.6
sw0657841TagBaseVlanEntryActionThe row status of VLAN.
1 - active
2 - notInService
3 - delete
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.14.2.3.1.7
.1.3.6.1.4.1.5205.2.34.1.14.3 · 1 row entry · 8 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841VlanPortConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841VlanPortConfTable'
This is the port parameters for tagged-based VLAN.
sw0657841VlanPortConfEntry row .1.3.6.1.4.1.5205.2.34.1.14.3.1
These are the tagged-based VLAN parameters for each ports.
Column Syntax OID
sw0657841VlanPortConfIndexThis is the index of the tagged-based vlan port parameters.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.14.3.1.1
sw0657841VlanPortConfVlanAware0 - Ignore incoming VLAN tag, using pvid as VLAN classification.
1 - Using VLAN tag information first.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.14.3.1.2
sw0657841VlanPortConfIngressFilteringIf the packet is tagged with VLAN information, the ingress port will first determine if the
ingress port itself is a member of the tagged VLAN.
0 - Disable, don't care about the VLAN information of the packet.
1 - Enabl…
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.14.3.1.3
sw0657841VlanPortConfFrameTypeTo determine what kind of packet the port should accept.
0 - All
1 - Only tagged packet
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.14.3.1.4
sw0657841VlanPortConfPvidEach physical port has a parameter called PVID.
All untagged frames are assigned to the LAN specified in the PVID parameter.
When a tagged frame is received by a port, the tag is respected.
If the frame is untagged, the…
Integer32r/w
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.14.3.1.5
sw0657841VlanPortConfRole0 - Access: won't send packet with tag.
1 - Trunk: always send packet with tag.
2 - Hybrid: always send packet with tag but one.
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.14.3.1.6
sw0657841VlanPortConfUntagVidWon't send packet with tag in one specific vid. Only available in hybrid mode.Integer32r/w
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.14.3.1.7
sw0657841VlanPortConfDoubleTagThis is the double tag configuration for ports.
0 -- Disable,
1 -- Service,
2 -- Customer
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.14.3.1.8
.1.3.6.1.4.1.5205.2.34.1.14.4.3 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841PortBaseVlanGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841PortBaseVlanGroupTable'
A list of port base vlan group entry. The numbers of entries are given by the value of sw0657841PortBaseVlanNumber.
sw0657841PortBaseVlanGroupEntry row .1.3.6.1.4.1.5205.2.34.1.14.4.3.1
This is the Entry(s) for Port Base VLAN Group configuration information.
Column Syntax OID
sw0657841PortBaseVlanGroupIndexThis is the index of the Port Base VLAN Group configuration entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.14.4.3.1.1
sw0657841PortBaseVlanGroupNameThe name of vlan.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.14.4.3.1.2
sw0657841PortBaseVlanGroupMembersThe member of vlan.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.14.4.3.1.3
sw0657841PortBaseVlanGroupEntryActionThe row status of vlan.
1 : active,
2 : not-inService,
3 : delete
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.14.4.3.1.4
.1.3.6.1.4.1.5205.2.34.1.15.1.2 · 1 row entry · 2 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841MacTableLearningConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841MacTableLearningConfTable'
A list of Mac Learning entry.
sw0657841MacTableLearningConfEntry row .1.3.6.1.4.1.5205.2.34.1.15.1.2.1
This is the Entry(s) for Mac Learning table information.
Column Syntax OID
sw0657841MacTableLearningConfIndexThis is the index of the Learning MAC Table Group configuration entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.15.1.2.1.1
sw0657841MacTableLearningConfstate0 - Auto
1 - Disable
2 - Secure
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.15.1.2.1.2
.1.3.6.1.4.1.5205.2.34.1.15.2.3 · 1 row entry · 5 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841MacTableStaticFilterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841MacTableStaticFilterTable'
A list of static filter entry. The numbers of entries are given by the value of sw0657841MacTableStaticFilterNumber.
sw0657841MacTableStaticFilterEntry row .1.3.6.1.4.1.5205.2.34.1.15.2.3.1
This is the Entry(s) for static filter information.
Column Syntax OID
sw0657841MacTableStaticFilterIndexThis is the index of the Static Filter MAC Table Group configuration entry.Integer32
Constraints:
range: 1-512
.1.3.6.1.4.1.5205.2.34.1.15.2.3.1.1
sw0657841MacTableStaticFilterMacThe static filter mac in Mac TableSNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.15.2.3.1.2
sw0657841MacTableStaticFilterVidThe filter vid in Mac TableInteger32r/w
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.15.2.3.1.3
sw0657841MacTableStaticFilterAliasThe filter alias name in Mac TableSNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.15.2.3.1.4
sw0657841MacTableStaticFilterEntryActionThe row status of filter entry.
1 - active
2 - notInService
3 - delete
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.15.2.3.1.5
.1.3.6.1.4.1.5205.2.34.1.15.3.3 · 1 row entry · 6 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841MacTableStaticForwardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841MacTableStaticForwardTable'
A list of static forward entry. The numbers of entries are given by the value of sw0657841MacTableStaticForwardNumber.
sw0657841MacTableStaticForwardEntry row .1.3.6.1.4.1.5205.2.34.1.15.3.3.1
Column Syntax OID
sw0657841MacTableStaticForwardIndexThis is the index of the Static Forward MAC Table Group configuration entry.Integer32
Constraints:
range: 1-512
.1.3.6.1.4.1.5205.2.34.1.15.3.3.1.1
sw0657841MacTableStaticForwardMacThe static forwarding Mac in Mac TableSNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.15.3.3.1.2
sw0657841MacTableStaticForwardPortTo specify a destination port for a mac address in mac table.Integer32r/w
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.15.3.3.1.3
sw0657841MacTableStaticForwardVidTo specify a VLAN ID for a mac address in mac table.Integer32r/w
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.15.3.3.1.4
sw0657841MacTableStaticForwardAliasTo specify an alias for a mac address in mac table.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.15.3.3.1.5
sw0657841MacTableStaticForwardEntryActionThe row status of filter entry.
1 - active
2 - notInService
3 - delete
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.15.3.3.1.6
.1.3.6.1.4.1.5205.2.34.1.15.4.3 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841MacAliasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841MacAliasTable'
A list of Mac Alias entry. The numbers of entries are given by the value of sw0657841MacAliasNumber.
sw0657841MacAliasEntry row .1.3.6.1.4.1.5205.2.34.1.15.4.3.1
Entry(s) for Mac Alias.
Column Syntax OID
sw0657841MacAliasIndexThe index of the static mac alias entry.Integer32
Constraints:
range: 1-1024
.1.3.6.1.4.1.5205.2.34.1.15.4.3.1.1
sw0657841AliasMacThe Mac of the static mac alias entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.15.4.3.1.2
sw0657841AliasNameThe alias name of the static mac alias entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.15.4.3.1.3
sw0657841MacAliasEntryActionThe row status of mac alias entry.
1 - active
2 - notInService
3 - delete
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.15.4.3.1.4
.1.3.6.1.4.1.5205.2.34.1.16.1.2 · 1 row entry · 7 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841GvrpConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841GvrpConfTable'
A list of GVRP entry.
sw0657841GvrpConfEntry row .1.3.6.1.4.1.5205.2.34.1.16.1.2.1
This is the Entry(s) for gvrp information.
Column Syntax OID
sw0657841GvrpConfIndexThis is the index of the gvrp entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.1
sw0657841GvrpConfJoinTimeThis is the join-time of the gvrp entry.Integer32r/w
Constraints:
range: 20-100
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.2
sw0657841GvrpConfLeaveTimeThis is the leave-time of the gvrp entry.
default:60 centisecond
Integer32r/w
Constraints:
range: 60-300
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.3
sw0657841GvrpConfLeaveAllTimedefault: 1000 unit timeInteger32r/w
Constraints:
range: 1000-5000
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.4
sw0657841GvrpConfDefaultAppMode[default: Normal]
0 - Normal
1 - Non-Participant
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.5
sw0657841GvrpConfDefaultRegMode[default: Normal]
0 - Normal
1 - Fixed
2 - Forbidden
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.6
sw0657841GvrpConfRestrictedMode[default: Disable]
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.16.1.2.1.7
.1.3.6.1.4.1.5205.2.34.1.16.2.1 · 1 row entry · 14 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841GvrpCounterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841GvrpCounterTable'
This is a list of SW0657841GvrpCounterEntry.
sw0657841GvrpCounterEntry row .1.3.6.1.4.1.5205.2.34.1.16.2.1.1
This is the Entry(s) for gvrp counter information.
Column Syntax OID
sw0657841GvrpCounterIndexThis is the index of the gvrp counter entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.1
sw0657841GvrpCounterRxTotalGvrpPktsGet the amount of all received gvrp packets of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.2
sw0657841GvrpCounterRxInvalidGvrpPktsGet the amount of received invalid gvrp packets of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.3
sw0657841GvrpCounterRxLeaveAllMsgGet the amount of received leave-all-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.4
sw0657841GvrpCounterRxJoinEmptyMsgGet the amount of received join-empty-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.5
sw0657841GvrpCounterRxJoinInMsgGet the amount of received join-in-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.6
sw0657841GvrpCounterRxLeaveEmptyMsgGet the amount of received leave-empty-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.7
sw0657841GvrpCounterRxEmptyMsgGet the amount of received empty-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.8
sw0657841GvrpCounterTxTotalGvrpPktsGet the amount of all transmitted gvrp packets of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.9
sw0657841GvrpCounterTxLeaveAllMsgGet the amount of transmitted leave-all-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.10
sw0657841GvrpCounterTxJoinEmptyMsgGet the amount of transmitted join-empty-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.11
sw0657841GvrpCounterTxJoinInMsgGet the amount of transmitted join-in-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.12
sw0657841GvrpCounterTxLeaveEmptyMsgGet the amount of transmitted leave-empty-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.13
sw0657841GvrpCounterTxEmptyMsgGet the amount of transmitted empty-message of the gvrp counter entry.SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.16.2.1.1.14
.1.3.6.1.4.1.5205.2.34.1.16.3.2 · 1 row entry · 3 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841GvrpGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841GvrpGroupTable'
This is a list of SW0657841GvrpGroupEntry.
sw0657841GvrpGroupEntry row .1.3.6.1.4.1.5205.2.34.1.16.3.2.1
This is the Entry(s) for gvrp group information.
Column Syntax OID
sw0657841GvrpGroupIdThis is the index of the gvrp group entry.Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.16.3.2.1.1
sw0657841GvrpGroupVidThis is the vlan id of the gvrp grout entry.Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.16.3.2.1.2
sw0657841GvrpGroupMemberPortThe member ports of the gvrp grout entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.16.3.2.1.3
.1.3.6.1.4.1.5205.2.34.1.16.3.3 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841GvrpGroupAdministrativeCtrlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841GvrpGroupAdministrativeCtrlTable'
This is a list of SW0657841GvrpGroupAdministrativeCtrlEntry.
sw0657841GvrpGroupAdministrativeCtrlEntry row .1.3.6.1.4.1.5205.2.34.1.16.3.3.1
This is the Entry(s) for gvrp group administrative information.
Column Syntax OID
sw0657841GvrpGroupAdministrativeCtrlVidThis is the vlan id of the gvrp-group-admin entry.Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.16.3.3.1.1
sw0657841GvrpGroupAdministrativeCtrlPortThis is the port number of the gvrp-group-admin entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.16.3.3.1.2
sw0657841GvrpGroupAdministrativeCtrlAppSet gvrp applicant.
0 - Normal
1 - Non-Participant
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.16.3.3.1.3
sw0657841GvrpGroupAdministrativeCtrlRegSet gvrp registrar.
0 - Normal
1 - Fixed
2 - Forbidden
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.16.3.3.1.4
.1.3.6.1.4.1.5205.2.34.1.17.1.2 · 1 row entry · 9 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841QosPortConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841QosPortConfTable'
QoS parameter for ports.
sw0657841QosPortConfEntry row .1.3.6.1.4.1.5205.2.34.1.17.1.2.1
QoS parameter for ports.
Column Syntax OID
sw0657841QosPortConfIndexThis is the port number for QoS configuration.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.1
sw0657841QosPortConfDefaultClassesThis is the default class for packets mismatch the specified QCL setting.
0 - Low
1 - Normal
2 - Medium
3 - High
Integer32r/w
Constraints:
range: 0-3
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.2
sw0657841QosPortConfQCLThis is where to specify the QoS Control List the port should apply.Integer32r/w
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.3
sw0657841QosPortConfUserPriorityThis is the default ingress VLAN tag priorityInteger32r/w
Constraints:
range: 0-7
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.4
sw0657841QosPortConfQueuingMode0 - Strict Priority
1 - Weighted Fair
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.5
sw0657841QosPortConfQueueWeightedLowTo specify how many quotas the low queue can be distributed.
Only available when the queueing mode is Weighted Fair.
Integer32r/w
Constraints:
range: 1-2
range: 4-4
range: 8-8
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.6
sw0657841QosPortConfQueueWeightedNormalTo specify how many quotas the normal queue can be distributed.
Only available when the queueing mode is Weighted Fair.
Integer32r/w
Constraints:
range: 1-2
range: 4-4
range: 8-8
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.7
sw0657841QosPortConfQueueWeightedMediumTo specify how many quotas the medium queue can be distributed.
Only available when the queueing mode is Weighted Fair.
Integer32r/w
Constraints:
range: 1-2
range: 4-4
range: 8-8
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.8
sw0657841QosPortConfQueueWeightedHighTo specify how many quotas the high queue can be distributed.
Only available when the queueing mode is Weighted Fair.
Integer32r/w
Constraints:
range: 1-2
range: 4-4
range: 8-8
.1.3.6.1.4.1.5205.2.34.1.17.1.2.1.9
.1.3.6.1.4.1.5205.2.34.1.17.3.1 · 1 row entry · 5 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841QosRateLimitersTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841QosRateLimitersTable'
This is the port bandwidth configuration.
sw0657841QosRateLimitersEntry row .1.3.6.1.4.1.5205.2.34.1.17.3.1.1
This is the port bandwidth configuration.
Column Syntax OID
sw0657841QosRateLimitersIndexThis is the port number for rate limit configurationInteger32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.17.3.1.1.1
sw0657841QosRateLimitersPolicerThis is the ingress bandwidth function for specific port.
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.17.3.1.1.2
sw0657841QosRateLimitersPolicerRateTo set the ingress bandwidth for specific port.
Available value is from 500k to 1000000k
Integer32r/w
Constraints:
range: 1-1000000
.1.3.6.1.4.1.5205.2.34.1.17.3.1.1.3
sw0657841QosRateLimitersShaperThis is the egress bandwidth function for specific port.
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.17.3.1.1.4
sw0657841QosRateLimitersShaperRateTo set the ingress bandwidth for specific port.
Available value is from 500k to 1000000k
Integer32r/w
Constraints:
range: 1-1000000
.1.3.6.1.4.1.5205.2.34.1.17.3.1.1.5
.1.3.6.1.4.1.5205.2.34.1.18.1 · 1 row entry · 6 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841AclPortsConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841AclPortsConfTable'
This is a list of port configuration entry.
sw0657841AclPortsConfEntry row .1.3.6.1.4.1.5205.2.34.1.18.1.1
This is the Entry(s) for ACL port information.
Column Syntax OID
sw0657841AclPortsConfIndexThis is the port number of the ACL port entry.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.18.1.1.1
sw0657841AclPortsConfPolicyIdThis is the policy id of the ACL port entry.Integer32r/w
Constraints:
range: 1-8
.1.3.6.1.4.1.5205.2.34.1.18.1.1.2
sw0657841AclPortsConfActionSet the action of the ACL port entry.
0 - Deny
1 - Permit
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.18.1.1.3
sw0657841AclPortsConfRateLimiterIdSet the rate limiter id of the ACL port entry.
0 - Disable
Integer32r/w
Constraints:
range: 0-16
.1.3.6.1.4.1.5205.2.34.1.18.1.1.4
sw0657841AclPortsConfPortCopySet the mirror port of the ACL port entry.
0 - Disable
Integer32r/w
Constraints:
range: 0-24
.1.3.6.1.4.1.5205.2.34.1.18.1.1.5
sw0657841AclPortsConfCounterThis is the port counter of the ACL port entry.
0 - Disable
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.18.1.1.6
.1.3.6.1.4.1.5205.2.34.1.18.2.1 · 1 row entry · 2 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841AclRateLimiterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841AclRateLimiterTable'
This is a list of SW0657841RateLimiterEntry.
sw0657841AclRateLimiterEntry row .1.3.6.1.4.1.5205.2.34.1.18.2.1.1
This is the Entry(s) for rate limiter information.
Column Syntax OID
sw0657841AclRateLimiterIndexThis is the index of the rate limiter entry.Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.5205.2.34.1.18.2.1.1.1
sw0657841AclRateLimiterRate(pps) 1 | 2 | 4 | 8 | 16 | 32 | 64 | 128 | 256 | 512 | 1k | 2k | 4k | 8k | 16k | 32k |64k | 128k | 256k | 512k | 1024kSNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.18.2.1.1.2
.1.3.6.1.4.1.5205.2.34.1.19.2.3 · 1 row entry · 6 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841IpMacBindSettingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841IpMacBindSettingTable'
This is a list of SW0657841IpMacBindSettingEntry.
sw0657841IpMacBindSettingEntry row .1.3.6.1.4.1.5205.2.34.1.19.2.3.1
This is the entry of the ip_mac_binding information.
Column Syntax OID
sw0657841IpMacBindSettingIndexThis is the index of the ip_mac_binding entry.Integer32
Constraints:
range: 1-1024
.1.3.6.1.4.1.5205.2.34.1.19.2.3.1.1
sw0657841IpMacBindSettingMACThis is the mac address of the ip_mac_binding entry.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.19.2.3.1.2
sw0657841IpMacBindSettingIPThis is the ip address of the ip_mac_binding entry.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.5205.2.34.1.19.2.3.1.3
sw0657841IpMacBindSettingPortThis is the port number of the ip_mac_binding entry.Integer32r/w
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.19.2.3.1.4
sw0657841IpMacBindSettingVIDThis is the vid of the ip_mac_binding entry.Integer32r/w
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.19.2.3.1.5
sw0657841IpMacBindSettingEntryAction1 - active
2 - notInService
3 - delete
Integer32r/w
Constraints:
range: 1-3
.1.3.6.1.4.1.5205.2.34.1.19.2.3.1.6
.1.3.6.1.4.1.5205.2.34.1.23.2 · 1 row entry · 11 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841Dot1XPortConfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841Dot1XPortConfTable'
A table that contains the configuration objects for the
Authenticator PAE associated with each port.
sw0657841Dot1XPortConfEntry row .1.3.6.1.4.1.5205.2.34.1.23.2.1
The configuration information for an Authenticator PAE.
Column Syntax OID
sw0657841Dot1XPortThe port index of 802.1X port configuration table.Integer32r/w
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.23.2.1.1
sw0657841Dot1XPortModeGet/Set IEEE 802.1X port mode.
0 - Disable
1 - Normal
2 - Advanced
3 - Clientless
Integer32r/w
Constraints:
range: 0-3
.1.3.6.1.4.1.5205.2.34.1.23.2.1.2
sw0657841Dot1XPortControlThe current value of the controlled Port
control parameter of the Port.
0 : ForceUnauthorized,
1 : ForceAuthorized,
2 : Auto
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.23.2.1.3
sw0657841Dot1XPortreAuthMaxThe value of the reAuthMax constant currently in use by
the Authenticator PAE state machine.
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.5205.2.34.1.23.2.1.4
sw0657841Dot1XPorttxPeriodThe value, in seconds, of the txPeriod constant
currently in use by the Authenticator PAE state
machine.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5205.2.34.1.23.2.1.5
sw0657841Dot1XPortquietPeriodThe value, in seconds, of the quietPeriod constant
currently in use by the Authenticator PAE state
machine.
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.5205.2.34.1.23.2.1.6
sw0657841Dot1XPortreAuthEnabledThe enable/disable control used by the Reauthentication
Timer state machine.
0 - Disable
1 - Enable
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.23.2.1.7
sw0657841Dot1XPortreAuthPeriodThe value, in seconds, of the reAuthPeriod constant
currently in use by the Reauthentication Timer state
machine.
Integer32r/w
Constraints:
range: 1-65535
.1.3.6.1.4.1.5205.2.34.1.23.2.1.8
sw0657841Dot1XPortmaxReqThe value of the maxReq constant currently in use by
the Backend Authentication state machine.
Integer32r/w
Constraints:
range: 1-10
.1.3.6.1.4.1.5205.2.34.1.23.2.1.9
sw0657841Dot1XPortsuppTimeoutThe value, in seconds, of the suppTimeout constant
currently in use by the Backend Authentication state
machine.
Integer32r/w
Constraints:
range: 1-255
.1.3.6.1.4.1.5205.2.34.1.23.2.1.10
sw0657841Dot1XPortserverTimeoutThe value, in seconds, of the serverTimeout constant
currently in use by the Backend Authentication state
machine.
Integer32r/w
Constraints:
range: 1-255
.1.3.6.1.4.1.5205.2.34.1.23.2.1.11
.1.3.6.1.4.1.5205.2.34.1.23.3 · 1 row entry · 3 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841Dot1XStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841Dot1XStatusTable'
A table that contains the status objects for the
Authenticator PAE associated with each port.
sw0657841Dot1XStatusEntry row .1.3.6.1.4.1.5205.2.34.1.23.3.1
The status information for an Authenticator PAE.
Column Syntax OID
sw0657841Dot1XStatusIndexThe port index of 802.1X status table.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.23.3.1.1
sw0657841Dot1XStatusModeThe current mode of the controlled port.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.23.3.1.2
sw0657841Dot1XStatusStatusThe current status of the controlled port.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.23.3.1.3
.1.3.6.1.4.1.5205.2.34.1.23.4 · 1 row entry · 30 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841Dot1XStatisticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841Dot1XStatisticsTable'
A table that contains the statistics objects for the
Authenticator PAE associated with each port.
sw0657841Dot1XStatisticsEntry row .1.3.6.1.4.1.5205.2.34.1.23.4.1
The statistics information for an Authenticator PAE.
Column Syntax OID
sw0657841Dot1XStatisticsIndexThe port index of the 802.1X statistics table.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.23.4.1.1
sw0657841Dot1XClearCounterReset the 802.1X counter associated with this port.
0 - do nothing
1 - clear
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.23.4.1.2
sw0657841Dot1XAuthEntersConnectingCounts the number of times that the state machine
transitions to the CONNECTING state from any other
state.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.3
sw0657841Dot1XauthEapLogoffsWhileConnectingCounts the number of times that the state machine
transitions from CONNECTING to DISCONNECTED as a result
of receiving an EAPOL-Logoff message.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.4
sw0657841Dot1XAuthEntersAuthenticatingCounts the number of times that the state machine
transitions from CONNECTING to AUTHENTICATING, as a
result of an EAP-Response/Identity message being
received from the Supplicant.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.5
sw0657841Dot1XAuthAuthSuccessesWhileAuthenticatingCounts the number of times that the state machine
transitions from AUTHENTICATING to AUTHENTICATED, as a
result of the Backend Authentication state machine
indicating successful authentication of the Supplicant.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.6
sw0657841Dot1XAuthAuthTimeoutsWhileAuthenticatingCounts the number of times that the state machine
transitions from AUTHENTICATING to ABORTING, as a result
of the Backend Authentication state machine indicating
authentication timeout.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.7
sw0657841Dot1XAuthAuthFailWhileAuthenticatingCounts the number of times that the state machine
transitions from AUTHENTICATING to HELD, as a result
of the Backend Authentication state machine indicating
authentication failure.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.8
sw0657841Dot1XAuthAuthEapStartsWhileAuthenticatingCounts the number of times that the state machine
transitions from AUTHENTICATING to ABORTING, as a result
of an EAPOL-Start message being received from the
Supplicant.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.9
sw0657841Dot1XAuthAuthEapLogoffWhileAuthenticatingCounts the number of times that the state machine
transitions from AUTHENTICATING to ABORTING, as a result
of an EAPOL-Logoff message being received from the
Supplicant.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.10
sw0657841Dot1XAuthAuthReauthsWhileAuthenticatedCounts the number of times that the state machine
transitions from AUTHENTICATED to CONNECTING, as a
result of a reauthentication request.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.11
sw0657841Dot1XAuthAuthEapStartsWhileAuthenticatedCounts the number of times that the state machine
transitions from AUTHENTICATED to CONNECTING, as a
result of an EAPOL-Start message being received from
the Supplicant.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.12
sw0657841Dot1XAuthAuthEapLogoffWhileAuthenticatedCounts the number of times that the state machine
transitions from AUTHENTICATED to DISCONNECTED, as a
result of an EAPOL-Logoff message being received from
the Supplicant.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.13
sw0657841Dot1XBackendResponsesCounts the number of times that the state machine sends
an initial Access-Request packet to the Authentication
server (i.e., executes sendRespToServer on entry to the
RESPONSE state). Indicates that the Authenticator
at…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.14
sw0657841Dot1XBackendAccessChallengesCounts the number of times that the state machine receives
an initial Access-Challenge packet from the Authentication
server (i.e., aReq becomes TRUE, causing exit from the
RESPONSE state). Indicates that the Authentica…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.15
sw0657841Dot1XBackendOtherRequestsToSupplicantCounts the number of times that the state machine sends
an EAP-Request packet (other than Indentity, Notification,
Faluire or Success message) to the Supplicant (i.e.,
executes txReq on entry to the REQUEST state). Indi…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.16
sw0657841Dot1XBackendAuthSuccessesCounts the number of times that the state machine receives
an EAP-Success message from the Authentication Server (i.e.,
aSuccess becomes TRUE, causing a transitions from RESPONSE to
SUCCESS). Indicates that the Supplica…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.17
sw0657841Dot1XBackendAuthFailsCounts the number of times that the state machine receives
an EAP-Failure message from the Authentication Server (i.e.,
aFail becomes TRUE, causing a transitions from RESPONSE to
FAIL). Indicates that the Supplicant has…
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.18
sw0657841Dot1XAuthEapolFramesRxThe number of valid EAPOL frames of any type
that have been received by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.19
sw0657841Dot1XAuthEapolFramesTxThe number of valid EAPOL frames of any type
that have been transmitted by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.20
sw0657841Dot1XAuthEapolStartFramesRxThe number of EAPOL Start frames that have
been received by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.21
sw0657841Dot1XAuthEapolLogoffFramesRxThe number of EAPOL Logoff frames that have
been received by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.22
sw0657841Dot1XAuthEapolRespIdFramesRxThe number of EAP Resp/Id frames that have
been received by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.23
sw0657841Dot1XAuthEapolRespFramesRxThe number of valid EAP Response frames
(other than Resp/Id frames) that have been
received by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.24
sw0657841Dot1XAuthEapolReqIdFramesTxThe number of EAP Req/Id frames that have
been transmitted by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.25
sw0657841Dot1XAuthEapolReqFramesTxThe number of valid EAP Request frames
(other than Req/Id frames) that have been
transmitted by this Authenticator.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.26
sw0657841Dot1XAuthInvalidEapolFramesRxThe number of EAPOL frames that have been
received by this Authenticator in which the
frame type is not recognized.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.27
sw0657841Dot1XAuthEapLengthErrorFramesRxThe number of EAPOL frames that have been
received by this Authenticator in which the
Packet Body Length field is invalid.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.28
sw0657841Dot1XAuthLastEapolFrameVersionThe protocol version number carried in the
most recently received EAPOL frames.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.5205.2.34.1.23.4.1.29
sw0657841Dot1XAuthLastEapolFrameSourceThe source MAC address carried in the
most recently received EAPOL frames.
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.23.4.1.30
.1.3.6.1.4.1.5205.2.34.1.24.1.1 · 1 row entry · 7 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841TrunkPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841TrunkPortTable'
This is a list of SW0657841TrunkPortEntry.
sw0657841TrunkPortEntry row .1.3.6.1.4.1.5205.2.34.1.24.1.1.1
Entry(s) for trunk table.
Column Syntax OID
sw0657841TrunkPortIndexThe port index of trunk table.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.1
sw0657841TrunkPortMethodThe method of trunk port.
0 : None,
1 : LACP,
2 : Static.
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.2
sw0657841TrunkPortGroupThe group(0~12) of trunk port.Integer32r/w
Constraints:
range: 0-12
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.3
sw0657841TrunkPortActiveLacpThe active lacp mode of trunk port.
0 : Passive,
1 : Active.
Integer32r/w
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.4
sw0657841TrunkPortAggtrThe Aggtr of trunk port.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.5
sw0657841TrunkPortStatusThe status of trunk port.
0 : None,
1 : Ready.
Integer32
Constraints:
range: 0-1
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.6
sw0657841TrunkPortCurrentModeThe current mode of trunk port entry.
0 : Active mode,
1 : Edit mode,
2 : Do edit.
Integer32r/w
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.24.1.1.1.7
.1.3.6.1.4.1.5205.2.34.1.24.2.1 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841AggregatorViewTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841AggregatorViewTable'
This is a list of SW0657841AggregatorViewEntry.
sw0657841AggregatorViewEntry row .1.3.6.1.4.1.5205.2.34.1.24.2.1.1
Entry(s) for aggregator view table.
Column Syntax OID
sw0657841AggregatorViewIndexThe port index of aggregator view table.Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.5205.2.34.1.24.2.1.1.1
sw0657841AggregatorViewMethodThe method of aggregator view table.
0 : None,
1 : LACP,
2 : Static.
Integer32
Constraints:
range: 0-2
.1.3.6.1.4.1.5205.2.34.1.24.2.1.1.2
sw0657841AggregatorViewMemberPortsThe member ports of aggregator view table.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.24.2.1.1.3
sw0657841AggregatorViewReadyPortsThe ready ports of aggregator view table.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.24.2.1.1.4
.1.3.6.1.4.1.5205.2.34.1.25.11 · 1 row entry · 4 columns
Uses the signamax variant from /opt/observium/mibs/signamax.
Command help
Walk sw0657841IgmpGroupMembershipTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'INTELEK-SW0657841-MIB' -M '/opt/observium/mibs/signamax:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'INTELEK-SW0657841-MIB::sw0657841IgmpGroupMembershipTable'
Get multicast group membership.
sw0657841IgmpGroupMembershipEntry row .1.3.6.1.4.1.5205.2.34.1.25.11.1
Multicast group membership entry.
Column Syntax OID
sw0657841IgmpGroupNoThe index of multicast group membership entry.Integer32
Constraints:
range: 1-1024
.1.3.6.1.4.1.5205.2.34.1.25.11.1.1
sw0657841IgmpGroupAddressThe group address of multicast group membership entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.25.11.1.2
sw0657841IgmpGroupVLANIdThe vlan id of multicast group membership entry.Integer32
Constraints:
range: 1-4094
.1.3.6.1.4.1.5205.2.34.1.25.11.1.3
sw0657841IgmpGroupPortMembersThe port member of multicast group membership entry.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.5205.2.34.1.25.11.1.4