ibmSpTrapTempC
| .1.3.6.1.4.1.2.6.158.5.0.0 | Critical Alert: Temperature threshold exceeded. |
ibmSpTrapVoltC
| .1.3.6.1.4.1.2.6.158.5.0.1 | Critical Alert: Voltage threshold exceeded. |
ibmSpTrapRdpsN
| .1.3.6.1.4.1.2.6.158.5.0.10 | Non-Critical Alert: Redundant Power Supply failure. |
ibmSpTrapFanC
| .1.3.6.1.4.1.2.6.158.5.0.11 | Critical Alert: Single Fan failure. |
ibmSpTrapTempN
| .1.3.6.1.4.1.2.6.158.5.0.12 | Non-Critical Alert: Temperature threshold exceeded. |
ibmSpTrapVoltN
| .1.3.6.1.4.1.2.6.158.5.0.13 | Non-Critical Alert: Voltage threshold exceeded. |
ibmSpTrapPowerN
| .1.3.6.1.4.1.2.6.158.5.0.164 | Non-Critical Alert: Power. |
ibmSpTrapFanN
| .1.3.6.1.4.1.2.6.158.5.0.165 | Non-Critical Alert: Fan Error. |
ibmSpTrapOsToS
| .1.3.6.1.4.1.2.6.158.5.0.21 | System Alert: OS Timeout value exceeded. |
ibmSpTrapAppS
| .1.3.6.1.4.1.2.6.158.5.0.22 | System Alert: Application Alert. Refer to Message ID for specific condition. |
ibmSpTrapPoffS
| .1.3.6.1.4.1.2.6.158.5.0.23 | System Alert: Power Off. |
ibmSpTrapPonS
| .1.3.6.1.4.1.2.6.158.5.0.24 | System Alert: Power On. |
ibmSpTrapBootS
| .1.3.6.1.4.1.2.6.158.5.0.25 | System Alert: System Boot Failure. |
ibmSpTrapLdrToS
| .1.3.6.1.4.1.2.6.158.5.0.26 | System Alert: OS Loader Timeout. |
ibmSpTrapPFAS
| .1.3.6.1.4.1.2.6.158.5.0.27 | System Alert: Predictive Failure Analysis(PFA) information. |
ibmSpTrapRLogin
| .1.3.6.1.4.1.2.6.158.5.0.30 | Sev-Off Alert: Event Remote Login. |
ibmSpTrapSysLogS
| .1.3.6.1.4.1.2.6.158.5.0.35 | System Alert: System Log 75% full. |
ibmSpTrapIhcC
| .1.3.6.1.4.1.2.6.158.5.0.36 | Critical Alert: Incompatible hardware configuration. |
ibmSpTrapNwChangeS
| .1.3.6.1.4.1.2.6.158.5.0.37 | System Alert: Network change notification. |
ibmSpTrapPowerC
| .1.3.6.1.4.1.2.6.158.5.0.4 | Critical Alert: Power failure. |
ibmSpTrapCPUC
| .1.3.6.1.4.1.2.6.158.5.0.40 | Critical Alert: CPU Error. |
ibmSpTrapMemoryC
| .1.3.6.1.4.1.2.6.158.5.0.41 | Critical Alert: Memory Error. |
ibmSpTrapCPUN
| .1.3.6.1.4.1.2.6.158.5.0.42 | Non-Critical Alert: CPU Error. |
ibmSpTrapMemoryN
| .1.3.6.1.4.1.2.6.158.5.0.43 | Non-Critical Alert: Memory Error. |
ibmSpTrapHdC
| .1.3.6.1.4.1.2.6.158.5.0.5 | Critical Alert: Hard disk drive failure. |
ibmSpTrapHardwareC
| .1.3.6.1.4.1.2.6.158.5.0.50 | Critical Alert: Other Failure - refer to Message ID for specific condition. |
ibmSpTrapHardwareN
| .1.3.6.1.4.1.2.6.158.5.0.60 | Non-Critical Alert: Warning - refer to Message ID for specific condition. |
ibmSpTrapRdpsC
| .1.3.6.1.4.1.2.6.158.5.0.9 | Critical Alert: Redundant Power Supply failure. |