ICT-SINE-WAVE-MIB

Recognized by Observium
Observium recognizes this MIB
Observium uses this MIB to identify device capabilities or determine applicability.
Explore Observium network monitoring
Source file
ICT-SINE-WAVE-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises IpAddress
RFC1213-MIB DisplayString
Objects (13)
.1.3.6.1.4.1.39145
.1.3.6.1.4.1.39145.12
deviceModel mandatory
.1.3.6.1.4.1.39145.12.1
inverterControl mandatory r/w
Enumeration
.1.3.6.1.4.1.39145.12.10
Enumeration
.1.3.6.1.4.1.39145.12.11
deviceName mandatory
.1.3.6.1.4.1.39145.12.2
deviceHardware mandatory
Integer32
.1.3.6.1.4.1.39145.12.3
deviceFirmware mandatory
.1.3.6.1.4.1.39145.12.4
deviceMacAddress mandatory
.1.3.6.1.4.1.39145.12.5
batteryVoltage mandatory
.1.3.6.1.4.1.39145.12.6
inverterVoltage mandatory
.1.3.6.1.4.1.39145.12.7
inverterPower mandatory
.1.3.6.1.4.1.39145.12.8
inverterStatus mandatory
Enumeration
.1.3.6.1.4.1.39145.12.9
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. SNMPv2-SMIrfc
  5. SNMPv2-TCrfc
  6. IANAifType-MIBrfc
  7. RFC1213-MIBrfc
  8. ICT-SINE-WAVE-MIBictselected
Notifications / Traps (14)
NameOIDDescription
.1.3.6.1.4.1.39145.12.0.101
Trap generated when the Battery Input Undervoltage Alarm is triggered
.1.3.6.1.4.1.39145.12.0.102
Trap generated when the Battery Input Overvoltage Alarm is triggered
.1.3.6.1.4.1.39145.12.0.103
Trap generated when the Overtemperature Alarm is triggered
.1.3.6.1.4.1.39145.12.0.104
Trap generated when the Inverter Output Fault Alarm is triggered
.1.3.6.1.4.1.39145.12.0.105
Trap generated when the System Fault Alarm is triggered
.1.3.6.1.4.1.39145.12.0.106
Trap generated when the Remote Switch accessory is activated
.1.3.6.1.4.1.39145.12.0.111
Trap generated when the Battery Input Undervoltage Alarm is cleared
.1.3.6.1.4.1.39145.12.0.112
Trap generated when the Battery Input Overvoltage Alarm is cleared
.1.3.6.1.4.1.39145.12.0.113
Trap generated when the Overtemperature Alarm is cleared
.1.3.6.1.4.1.39145.12.0.114
Trap generated when the Inverter Output Fault Alarm is cleared
.1.3.6.1.4.1.39145.12.0.115
Trap generated when the System Fault Alarm is cleared
.1.3.6.1.4.1.39145.12.0.116
Trap generated when the Remote Switch accessory is deactivated
.1.3.6.1.4.1.39145.12.0.121
Trap generated when the Output switches to Inverter (Battery) Power
.1.3.6.1.4.1.39145.12.0.122
Trap generated when the Output switches to Grid Power