ibmServeRaidNoControllers
| .1.3.6.1.4.1.2.6.167.2.0.201 | Informational: No controllers were found in this system. |
ibmServeRaidControllerFail
| .1.3.6.1.4.1.2.6.167.2.0.202 | Error: Commands not responding on Controller %d. |
ibmServeRaidDeadBattery
| .1.3.6.1.4.1.2.6.167.2.0.203 | Error: The battery-backup cache device on Controller %d needs a new battery. |
ibmServeRaidDeadBatteryCache
| .1.3.6.1.4.1.2.6.167.2.0.204 | Error: The battery-backup cache device on Controller %d is defective %d |
ibmServeRaidPollingFail
| .1.3.6.1.4.1.2.6.167.2.0.205 | Error: Background polling commands not responding on Controller %d %d |
ibmServeRaidConfigFail
| .1.3.6.1.4.1.2.6.167.2.0.206 | Error: Cannot read controller configuration. |
ibmServeRaidControllerAdded
| .1.3.6.1.4.1.2.6.167.2.0.207 | Informational: Controller %d has been added to the system. |
ibmServeRaidControllerReplaced
| .1.3.6.1.4.1.2.6.167.2.0.208 | Informational: Controller %d has been replaced in the system. |
ibmServeRaidControllerFailover
| .1.3.6.1.4.1.2.6.167.2.0.209 | Informational: Controller %d failover detected. Passive controller is now active. |
ibmServeRaidControllerVersionMismatch
| .1.3.6.1.4.1.2.6.167.2.0.210 | Warning: Controller %d version mismatch detected. The BIOS, Firmware, and Driver are not a matched set and are not compatible. |
ibmServeRaidControllerBatteryOvertemp
| .1.3.6.1.4.1.2.6.167.2.0.211 | Warning: Controller %d battery has exceeded normal operating temperature. |
ibmServeRaidLogicalDriveCritical
| .1.3.6.1.4.1.2.6.167.2.0.301 | Warning: Logical Drive %d is Critical on Controller %d. |
ibmServeRaidLogicalDriveBlocked
| .1.3.6.1.4.1.2.6.167.2.0.302 | Error: Logical Drive %d is Blocked on Controller %d. |
ibmServeRaidLogicalDriveOffLine
| .1.3.6.1.4.1.2.6.167.2.0.303 | Error: Logical Drive %d is Offline on Controller %d. |
ibmServeRaidRebuildDetected
| .1.3.6.1.4.1.2.6.167.2.0.304 | Informational: Rebuilding Logical Drive %d on Controller %d. |
ibmServeRaidRebuildComplete
| .1.3.6.1.4.1.2.6.167.2.0.305 | Informational: Rebuild complete on Logical Drive %d of Controller %d. |
ibmServeRaidRebuildFail
| .1.3.6.1.4.1.2.6.167.2.0.306 | Error: Rebuild failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidSyncDetected
| .1.3.6.1.4.1.2.6.167.2.0.307 | Informational: Synchronizing Logical Drive %d on Controller %d. |
ibmServeRaidSyncComplete
| .1.3.6.1.4.1.2.6.167.2.0.308 | Informational: Synchronization complete on Logical Drive %d of Controller %d. |
ibmServeRaidSyncFail
| .1.3.6.1.4.1.2.6.167.2.0.309 | Error: Synchronization failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidMigrationDetected
| .1.3.6.1.4.1.2.6.167.2.0.310 | Informational: Migrating Logical Drive %d on Controller %d. |
ibmServeRaidMigrationComplete
| .1.3.6.1.4.1.2.6.167.2.0.311 | Informational: Migration complete on Logical Drive %d of Controller %d. |
ibmServeRaidMigrationFail
| .1.3.6.1.4.1.2.6.167.2.0.312 | Error: Migration failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidCompressionDetected
| .1.3.6.1.4.1.2.6.167.2.0.313 | Informational: Compressing Logical Drive %d on Controller %d. |
ibmServeRaidCompressionComplete
| .1.3.6.1.4.1.2.6.167.2.0.314 | Informational: Compression complete on Logical Drive %d of Controller %d. |
ibmServeRaidcompressionFail
| .1.3.6.1.4.1.2.6.167.2.0.315 | Error: Compression failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidDecompressionDetected
| .1.3.6.1.4.1.2.6.167.2.0.316 | Informational: Decompressing Logical Drive %d on Controller %d. |
ibmServeRaidDecompressionComplete
| .1.3.6.1.4.1.2.6.167.2.0.317 | Informational: Decompression complete on Logical Drive %d of Controller %d. |
ibmServeRaidDecompressionFail
| .1.3.6.1.4.1.2.6.167.2.0.318 | Error: Decompression failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidFlashCopyDetected
| .1.3.6.1.4.1.2.6.167.2.0.319 | Informational: FlashCopying Logical Drive %d on Controller %d. |
ibmServeRaidFlashCopyComplete
| .1.3.6.1.4.1.2.6.167.2.0.320 | Informational: FlashCopy complete on Logical Drive %d of Controller %d. |
ibmServeRaidFlashCopyFail
| .1.3.6.1.4.1.2.6.167.2.0.321 | Error: FlashCopy failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidArrayRebuildDetected
| .1.3.6.1.4.1.2.6.167.2.0.322 | Informational: Rebuilding Array %d on Controller %d. |
ibmServeRaidArrayRebuildComplete
| .1.3.6.1.4.1.2.6.167.2.0.323 | Informational: Rebuild complete on Array %d of Controller %d. |
ibmServeRaidArrayRebuildFail
| .1.3.6.1.4.1.2.6.167.2.0.324 | Error: Rebuild failed on Array %d of Controller %d %d. |
ibmServeRaidArraySyncDetected
| .1.3.6.1.4.1.2.6.167.2.0.325 | Informational: Synchronizing Array %d on Controller %d. |
ibmServeRaidArraySyncComplete
| .1.3.6.1.4.1.2.6.167.2.0.326 | Informational: Synchronization complete on Array %d of Controller %d. |
ibmServeRaidArraySyncFail
| .1.3.6.1.4.1.2.6.167.2.0.327 | Error: Synchronization failed on Array %d of Controller %d %d. |
ibmServeRaidArrayFlashCopyDetected
| .1.3.6.1.4.1.2.6.167.2.0.328 | Informational: FlashCopying Array %d on Controller %d. |
ibmServeRaidArrayFlashCopyComplete
| .1.3.6.1.4.1.2.6.167.2.0.329 | Informational: FlashCopy complete on Array %d of Controller %d. |
ibmServeRaidArrayFlashCopyFail
| .1.3.6.1.4.1.2.6.167.2.0.330 | Error: FlashCopy failed on Array %d of Controller %d %d. |
ibmServeRaidLogicalDriveUnblocked
| .1.3.6.1.4.1.2.6.167.2.0.331 | Informational: Logical Drive %d is unblocked on Controller %d. |
ibmServeRaidCompactionDetected
| .1.3.6.1.4.1.2.6.167.2.0.332 | Informational: Compacting Logical Drive %d on Controller %d. |
ibmServeRaidCompactionComplete
| .1.3.6.1.4.1.2.6.167.2.0.333 | Informational: Compaction complete on Logical Drive %d of Controller %d. |
ibmServeRaidCompactionFail
| .1.3.6.1.4.1.2.6.167.2.0.334 | Error: Compaction failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidExpansionDetected
| .1.3.6.1.4.1.2.6.167.2.0.335 | Informational: Expanding Logical Drive %d on Controller %d. |
ibmServeRaidExpansionComplete
| .1.3.6.1.4.1.2.6.167.2.0.336 | Informational: Expansion complete on Logical Drive %d of Controller %d. |
ibmServeRaidExpansionFail
| .1.3.6.1.4.1.2.6.167.2.0.337 | Error: Expansion failed on Logical Drive %d of Controller %d %d. |
ibmServeRaidLogicalDriveCriticalPeriodic
| .1.3.6.1.4.1.2.6.167.2.0.338 | Warning: Periodic scan found 1 or more critical logical drives on Controller %d. |
ibmServeRaidDefunctDrive
| .1.3.6.1.4.1.2.6.167.2.0.401 | Error: Defunct drive on Controller %d, Channel %d, SCSI ID %d. |
ibmServeRaidPfaDrive
| .1.3.6.1.4.1.2.6.167.2.0.402 | Warning: PFA drive on Controller %d, Channel %d, SCSI ID %d. |
ibmServeRaidDefunctReplaced
| .1.3.6.1.4.1.2.6.167.2.0.403 | Informational: A drive is set to Hot-Spare on Controller %d, Channel %d, SCSI ID %d. |
ibmServeRaidDefunctDriveFru
| .1.3.6.1.4.1.2.6.167.2.0.404 | Error: Defunct drive (FRU Part # %d} on controller %d, channel %d, SCSI ID %d. |
ibmServeRaidPfaDriveFru
| .1.3.6.1.4.1.2.6.167.2.0.405 | Warning: PFA drive (FRU Part # %d) on Controller %d, Channel %d, SCSI ID %d. |
ibmServeRaidUnsupportedDrive
| .1.3.6.1.4.1.2.6.167.2.0.406 | Warning: Unsupported physical drive found on Controller %d, Channel %d, SCSI ID %d. |
ibmServeRaidEnclosureOK
| .1.3.6.1.4.1.2.6.167.2.0.501 | Informational: Enclosure device responding on Controller %d, Channel %d. |
ibmServeRaidEnclosureFail
| .1.3.6.1.4.1.2.6.167.2.0.502 | Error: Enclosure device not responding on Controller %d, Channel %d. |
ibmServeRaidFanOk
| .1.3.6.1.4.1.2.6.167.2.0.503 | Informational: Enclosure fan %d on Controller %d, Channel %d is now operational. |
ibmServeRaidFanFail
| .1.3.6.1.4.1.2.6.167.2.0.504 | Error: Enclosure fan %d on Controller %d, Channel %d is malfunctioning. |
ibmServeRaidFanInstalled
| .1.3.6.1.4.1.2.6.167.2.0.505 | Informational: Enclosure fan %d on Controller %d, Channel %d has been installed. |
ibmServeRaidFanRemoved
| .1.3.6.1.4.1.2.6.167.2.0.506 | Warning: Enclosure fan %d on Controller %d, Channel %d has been removed. |
ibmServeRaidTempOk
| .1.3.6.1.4.1.2.6.167.2.0.507 | Error: Enclosure temperature is in normal range on Controller %d, Channel %d. |
ibmServeRaidTempFail
| .1.3.6.1.4.1.2.6.167.2.0.508 | Error: Enclosure temperature is out of normal range on Controller %d, Channel %d. |
ibmServeRaidPowerSupplyOk
| .1.3.6.1.4.1.2.6.167.2.0.509 | Informational: Enclosure power supply %d on Controller %d, Channel %d is now operational. |
ibmServeRaidPowerSupplyFail
| .1.3.6.1.4.1.2.6.167.2.0.510 | Error: Enclosure power supply %d on Controller %d, Channel %d is malfunctioning. |
ibmServeRaidPowerSupplyInstalled
| .1.3.6.1.4.1.2.6.167.2.0.511 | Informational: Enclosure power supply %d on Controller %d, Channel %d has been installed. |
ibmServeRaidPowerSupplyRemoved
| .1.3.6.1.4.1.2.6.167.2.0.512 | Warning: Enclosure power supply %d on Controller %d, Channel %d has been removed. |
ibmServeRaidTestTrap
| .1.3.6.1.4.1.2.6.167.2.0.601 | Informational: This is a test trap. |