This object indicates the notification of the switchover of clock reference sources.
hwClockSourceFailed
.1.3.6.1.4.1.2011.5.25.186.1.8.11
This object indicates that the clock source is invalid.
hwClockSourceValid
.1.3.6.1.4.1.2011.5.25.186.1.8.12
This object indicates that the clock source is valid.
hwClockSourceFreqCheckResume
.1.3.6.1.4.1.2011.5.25.186.1.8.13
This object indicates an alarm that the clock source frequency detection is normal.
hwClockSourceOutputBelowThresholdResume
.1.3.6.1.4.1.2011.5.25.186.1.8.14
This object indicates an alarm that the SSM level output by the clock source is higher than the configured threshold.
hwClockCesAcrMasterPwChange
.1.3.6.1.4.1.2011.5.25.186.1.8.15
This object indicates a master PW change event. The object associated is hwClockCesAcrSlot, hwClockCesAcrCard, hwClockCesAcrDomain, hwClockCesAcrOldMasterPwName, hwClockCesAcrNewMasterPwName.
hwClockCesAcrLockFail
.1.3.6.1.4.1.2011.5.25.186.1.8.16
This object indicates an alarm that a CES ACR clock source is unlocked. The object associated is hwClockCesAcrSlot, hwClockCesAcrCard, hwClockCesAcrDomain, hwClockCesAcrLockState.
hwClockCesAcrLockFailResume
.1.3.6.1.4.1.2011.5.25.186.1.8.17
This object indicates an alarm that a CES ACR clock source is locked. The object associated is wClockCesAcrSlothwClockCesAcrCardhwClockCesAcrDomainhwClockCesAcrLockState.
hwClockSourceSysClkLockModeChange
.1.3.6.1.4.1.2011.5.25.186.1.8.2
This object indicates the notification of the change on the working mode of the system clock.
hwClockClusterTopoFail
.1.3.6.1.4.1.2011.5.25.186.1.8.22
This object indicates a clock synchronization topology planning failure between chassis in a cluster.
hwClockClusterTopoFailResume
.1.3.6.1.4.1.2011.5.25.186.1.8.23
This object indicates a clock synchronization topology planning success between chassis in a cluster.
hwClockSourceInputBelowThreshold
.1.3.6.1.4.1.2011.5.25.186.1.8.24
This object indicates an alarm that the input SSM level of the clock source is lower than the threshold.
hwClockSourceInputBelowThresholdResume
.1.3.6.1.4.1.2011.5.25.186.1.8.25
This object indicates an alarm that the input SSM level of the clock source reaches or exceeds the threshold.
hwClockSsmPktLos
.1.3.6.1.4.1.2011.5.25.186.1.8.26
This object indicates an alarm that ESMC packets are lost.
hwClockSsmPktLosResume
.1.3.6.1.4.1.2011.5.25.186.1.8.27
This object indicates that ESMC packet loss recovers.
hwClockCesDcrMasterPwChange
.1.3.6.1.4.1.2011.5.25.186.1.8.28
CES DCR master PW status change.
hwClockCesDcrLockFail
.1.3.6.1.4.1.2011.5.25.186.1.8.29
CES DCR clock source lock fail.
hwClockSourceStateChange
.1.3.6.1.4.1.2011.5.25.186.1.8.3
The state of clock source change notification.
hwClockCesDcrLockFailResume
.1.3.6.1.4.1.2011.5.25.186.1.8.30
CES DCR clock source lock fail resume.
hwClockSourceSsmChange
.1.3.6.1.4.1.2011.5.25.186.1.8.31
This object indicates that the clock source SSM is changed.
hwClockFMSwitch
.1.3.6.1.4.1.2011.5.25.186.1.8.32
Clock select mode is force or manual.
hwClockFMSwitchResume
.1.3.6.1.4.1.2011.5.25.186.1.8.33
Clock select mode is automative.
hwClockSyncBad
.1.3.6.1.4.1.2011.5.25.186.1.8.34
Clock frequency synchronization bad.
hwClockSyncBadResume
.1.3.6.1.4.1.2011.5.25.186.1.8.35
Clock frequency synchronization bad resume.
hwClockPortNonSupport
.1.3.6.1.4.1.2011.5.25.186.1.8.36
This object indicates an alarm that the interface does not support physical layer clock synchronization.
hwClockPortNonSupportResume
.1.3.6.1.4.1.2011.5.25.186.1.8.37
This object indicates an alarm that the interface supports physical layer clock synchronization.
hwClockGnssModelChange
.1.3.6.1.4.1.2011.5.25.186.1.8.38
The smart clock gnss model changed.
hwClockSourceStateResume
.1.3.6.1.4.1.2011.5.25.186.1.8.4
The state of clock source resume notification.
hwClockSourceFreqCheck
.1.3.6.1.4.1.2011.5.25.186.1.8.5
This object indicates the notification of the abnormal result of frequency offset detection of the clock reference clock.
hwClockSourceOutputBelowThreshold
.1.3.6.1.4.1.2011.5.25.186.1.8.6
This object indicates that the SSM level output by the clock source is lower than the configured threshold.
hwClockNotInLockedMode
.1.3.6.1.4.1.2011.5.25.186.1.8.7
This object indicates that the system clock is in the unlocked state.
hwClockInLockedMode
.1.3.6.1.4.1.2011.5.25.186.1.8.8
This object indicates that the system clock is in the locked state.