EntityExtTemperatureThresholdNotification
indicates the temperature exceeded the threshold.
In this condition, user should check the status and the
environment of the entity, sometimes it happens because
of the failure of air-condition.
hpnicfEntityExtSFPAlarmOff
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.10
s generated when the SFP module restores to
normal status.
hpnicfEntityExtSFPPhony
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.11
e is NOT sold by authorized manufacturer.
The normal function of the device or assume the maintenance
responsibility thereof will NOT be guaranteed.
The trap is generated periodically after a phony module has been
found.
hpnicfEntityInsert
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.12
s generated when a removable entity inserting to
device.
hpnicfEntityRemove
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.13
s generated when a removable entity removing from
device.
hpnicfEntityExtForcedPowerOff
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.14
The trap indicates the entity is forced to power off.
hpnicfEntityExtForcedPowerOn
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.15
The trap indicates the entity is forced to power on.
hpnicfEntityExtFaultAlarmOn
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.16
The trap indicates a fault occurs on the specified entity.
hpnicfEntityExtFaultAlarmOff
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.17
The trap indicates a fault disappears on the specified entity.
hpnicfEntityExtResourceLack
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.18
ndicates that a kind of resource is not enough on the
specified entity.
hpnicfEntityExtResourceEnough
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.19
ndicates that the entity recovers from the status of no
enough resource.
hpnicfEntityExtVoltageLowThresholdNotification
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.2
EntityExtVoltageLowThresholdNotification indicates
the voltage is lower than the threshold.
If the voltage is lower too much than the entity needs,
the entity will halt.
hpnicfEntityExtTemperatureLower
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.20
ndicates the temperature of a specified entity is under
the lower threshold. In this condition, user should check the
status and the environment of the entity, sometimes it goes wrong
for some reason.
hpnicfEntityExtTemperatureTooUp
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.21
ndicates the temperature of a specified entity exceeded
the shutdown threshold. In this condition, user should check the
status and the environment of the entity, sometimes it goes wrong
for some reason.
hpnicfEntityExtTemperatureNormal
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.22
ndicates the temperature of a specified entity recover
from abnormal status.
hpnicfEntityExternalAlarmOccur
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.23
s generated when the monitored device connected to the
specified entity fails.
hpnicfEntityExternalAlarmRecover
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.24
s generated when the failed device connected to the
specified entity returns to normal.
hpnicfEntityExtCpuUsageThresholdRecover
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.25
The trap indicates the CPU usage descends the threshold.
hpnicfEntityExtMemUsageThresholdRecover
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.26
The trap indicates the memory usage descends the threshold.
hpnicfEntityExtMemAllocatedFailed
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.27
The trap indicates the memory allocated failed.
hpnicfEntityExtECCParityAlarm
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.28
The trap indicates the ECC(Error Correction Code) parity error alarm.
hpnicfEntityExtCritLowerTempThresholdNotification
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.29
EntityExtCritLowerTempThresholdNotification
indicates the temperature is lower than the threshold.
If the temperature is lower too much than the entity needs,
the entity will halt.
hpnicfEntityExtVoltageHighThresholdNotification
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.3
EntityExtVoltageHighThresholdNotification indicates
the voltage is higher than the threshold.
If the voltage is higher too much than the entity needs,
The entity may be damaged by the high voltage.
hpnicfEntityExtTemperatureTooLow
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.30
EntityExtTemperatureTooLow indicates the temperature
is lower than the threshold.
If the temperature is lower too much than the entity needs,
the entity halts now.
hpnicfEntityExtFanDirectionNotPreferred
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.31
indicates the specified fan's direction does not
accord with preferred. The two parameters indicate the entity
index and physical name of fan.
hpnicfEntityExtFanDirectionNotAccord
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.32
indicates the direction of fans does not accord
with each other. The two parameters indicate the parent
entity of the fans.
hpnicfEntityExtSFPInvalid
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.33
eiver module is not compatible with the interface card.
The authorized manufacturer therefore shall NOT guarantee
the normal function of the transceiver.
The transceiver module will be invalidated in days.
Please replace it with a compatible one as soon as possible.
The trap is generated periodically after a phony transceiver module
has been found.
hpnicfEntityExtSFPInvalidNow
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.34
ceiver module is not compatible with the interface card.
The authorized manufacturer therefore shall NOT guarantee
the normal function of the transceiver.
The trap is generated after a phony transceiver module
has been found.
hpnicfEntityExtMemUsageThresholdOverTrap
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.35
indicates that the memory usage of the entity is
overloaded.
This trap is used to replace
hpnicfEntityExtMemUsageThresholdNotification.
hpnicfEntityExtMemUsageThresholdRecoverTrap
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.36
indicates that the memory usage decreased below
the threshold.
This trap is used to replace
hpnicfEntityExtMemUsageThresholdRecover.
hpnicfEntityExtVoltageNormal
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.37
This trap indicates that the voltage recovers to normal.
hpnicfEntityExtVoltageLower
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.38
indicates that the voltage is lower than the
low threshold.
hpnicfEntityExtVoltageTooLow
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.39
indicates that the voltage is lower than the
fatal low threshold.
hpnicfEntityExtCpuUsageThresholdNotfication
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.4
EntityExtCpuUsageThresholdNotfication indicates
the entity is overloaded.
hpnicfEntityExtVoltageHigher
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.40
indicates that the voltage is higher than the
high threshold.
hpnicfEntityExtVoltageTooHigh
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.41
indicates that the voltage is higher than the
fatal high threshold.
hpnicfEntityExtMemUsageThresholdNotification
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.5
EntityExtMemUsageThresholdNotification indicates
the entity is overloaded.
hpnicfEntityExtOperEnabled
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.6
The trap indicates the entity is operable at present.
hpnicfEntityExtOperDisabled
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.7
The trap indicates the entity is not operable at present.
EntityExtCriticalTemperatureThresholdNotification
indicates the temperature exceeds the critical temperature.
In this condition, user should check the status and the
environment of the entity, sometimes it happens because
of the failure of air-condition.
hpnicfEntityExtSFPAlarmOn
.1.3.6.1.4.1.11.2.14.11.15.2.6.2.0.9
s generated when the SFP module fails
or runs abnormally for some particular reason.