HPIPF02TRAP-MIB
- Source file
HPIPF02TRAP-MIB- Last revised
- Not declared
Imported Objects
| RFC-1212 | OBJECT-TYPE (no object page) |
| RFC-1215 | TRAP-TYPE (no object page) |
| RFC1155-SMI | enterprises |
| RFC1213-MIB | DisplayString |
Objects (6)
Showing 6 of 6 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.11 |
||
.1.3.6.1.4.1.11.2 |
||
.1.3.6.1.4.1.11.2.23 |
||
.1.3.6.1.4.1.11.2.23.35 |
||
.1.3.6.1.4.1.11.2.23.45 |
||
|
|
.1.3.6.1.4.1.11.2.23.45.1 |
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- RFC-1212rfc
- RFC-1215rfc
- RFC1155-SMIrfc
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- RFC1213-MIBrfc
- HPIPF02TRAP-MIBhpselected
Notifications / Traps (47)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.11.2.23.45.0.10 |
One of the voltage sensors crossed its upper non-critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.113 |
A SCSI cable has been removed from the hot swap cage.
|
|
.1.3.6.1.4.1.11.2.23.45.0.12 |
One of the voltage sensors crossed its upper non-recoverable threshold - Check all boards with this voltage
|
|
.1.3.6.1.4.1.11.2.23.45.0.26 |
The chassis has been opened.
|
|
.1.3.6.1.4.1.11.2.23.45.0.4 |
One of the temperature sensors crossed its upper non-critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.5 |
One of the temperature sensors crossed its upper critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.518 |
Uncorrectable multi-bit ECC error has occurred in memory module
|
|
.1.3.6.1.4.1.11.2.23.45.0.6 |
One of the temperature sensors crossed its upper non-recoverable threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.699 |
Machine Check Initiated
|
|
.1.3.6.1.4.1.11.2.23.45.0.700 |
System firmware error
|
|
.1.3.6.1.4.1.11.2.23.45.0.704 |
Voltage fault - Check all boards with this voltage
|
|
.1.3.6.1.4.1.11.2.23.45.0.705 |
Voltage degraded to non-recoverable level from less severe - Check all boards with this voltage
|
|
.1.3.6.1.4.1.11.2.23.45.0.706 |
Voltage becomes non-recoverable from either critical level or less severe level - Check all boards with this voltage
|
|
.1.3.6.1.4.1.11.2.23.45.0.707 |
Voltage absent
|
|
.1.3.6.1.4.1.11.2.23.45.0.710 |
Fan speed lags
|
|
.1.3.6.1.4.1.11.2.23.45.0.720 |
Power supply failed or disconnected
|
|
.1.3.6.1.4.1.11.2.23.45.0.722 |
Power supply AC lost
|
|
.1.3.6.1.4.1.11.2.23.45.0.726 |
A/C Failed, disconnected, or out of range
|
|
.1.3.6.1.4.1.11.2.23.45.0.728 |
Voltage degraded to critical level from less severe - Check all boards with this voltage
|
|
.1.3.6.1.4.1.11.2.23.45.0.729 |
System shut-down or reset caused by sensor reading.
|
|
.1.3.6.1.4.1.11.2.23.45.0.730 |
The BMC firmware did not detect the system firmware boot.
|
|
.1.3.6.1.4.1.11.2.23.45.0.731 |
A/C Failed, disconnected, or out of range
|
|
.1.3.6.1.4.1.11.2.23.45.0.732 |
The Power supply's sensors detect possible problems
|
|
.1.3.6.1.4.1.11.2.23.45.0.733 |
Cooling unit warning
|
|
.1.3.6.1.4.1.11.2.23.45.0.734 |
Cooling unit failure
|
|
.1.3.6.1.4.1.11.2.23.45.0.735 |
BMC entering special mode
|
|
.1.3.6.1.4.1.11.2.23.45.0.736 |
Watchdog timer expired - hard reset
|
|
.1.3.6.1.4.1.11.2.23.45.0.737 |
Watchdog timer expired - power-off
|
|
.1.3.6.1.4.1.11.2.23.45.0.738 |
Watchdog timer expired - power-cycle
|
|
.1.3.6.1.4.1.11.2.23.45.0.739 |
Missing FRU device
|
|
.1.3.6.1.4.1.11.2.23.45.0.740 |
Missing Entity
|
|
.1.3.6.1.4.1.11.2.23.45.0.744 |
System event log almost full
|
|
.1.3.6.1.4.1.11.2.23.45.0.745 |
TOC interrupt (crash dump)
|
|
.1.3.6.1.4.1.11.2.23.45.0.746 |
INIT Initiated
|
|
.1.3.6.1.4.1.11.2.23.45.0.747 |
PCI system error detected
|
|
.1.3.6.1.4.1.11.2.23.45.0.748 |
OS run-time critical shutdown
|
|
.1.3.6.1.4.1.11.2.23.45.0.749 |
ACPI state S5 (soft-off, entered by override)
|
|
.1.3.6.1.4.1.11.2.23.45.0.751 |
PCI parity error detected
|
|
.1.3.6.1.4.1.11.2.23.45.0.752 |
One of the temperature sensors crossed its lower non-critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.753 |
One of the temperature sensors crossed its upper critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.754 |
One of the temperature sensors crossed its upper non-recoverable threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.755 |
A temperature inside the server has gone outside the factory specified range.
|
|
.1.3.6.1.4.1.11.2.23.45.0.756 |
One of the temperature sensors crossed its upper critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.757 |
The Power Supply AC voltage was lost or is out of range.
|
|
.1.3.6.1.4.1.11.2.23.45.0.758 |
The AC voltage connected to the power supply is out of range.
|
|
.1.3.6.1.4.1.11.2.23.45.0.8 |
One of the voltage sensors crossed its lower critical threshold.
|
|
.1.3.6.1.4.1.11.2.23.45.0.9 |
One of the voltage sensors crossed its lower non-recoverable threshold.
|