HPE-SENSOR-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
8
entPhySensorTable
table.1.3.6.1.4.1.11.2.83.2.1.1
·
1 row entry
·
8 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk entPhySensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HPE-SENSOR-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HPE-SENSOR-MIB::entPhySensorTable'
This table contains one row per physical sensor represented by an associated row in the entPhysicalTable.
Information about a particular physical sensor.
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are cre…
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are cre…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| entPhySensorTypeThe type of data returned by the associated entPhySensorValue object. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation. | EntitySensorDataType Type Values:
| .1.3.6.1.4.1.11.2.83.2.1.1.1.1 | ||||||||||||||||||||||||||||||||||
| entPhySensorScaleThe exponent to apply to values returned by the associated entPhySensorValue object. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation. | EntitySensorDataScale Type Values:
| .1.3.6.1.4.1.11.2.83.2.1.1.1.2 | ||||||||||||||||||||||||||||||||||
| entPhySensorPrecisionThe number of decimal places of precision in fixed-point sensor values returned by the associated entPhySensorValue object. This object SHOULD be set to '0' when the associated entPhySensorType value is n… | EntitySensorPrecision Type Constraints: range: -8..9 | .1.3.6.1.4.1.11.2.83.2.1.1.1.3 | ||||||||||||||||||||||||||||||||||
| entPhySensorValueThe most recent measurement obtained by the agent for this sensor. To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects mu… | EntitySensorValue Type Constraints: range: -1000000000..1000000000 | .1.3.6.1.4.1.11.2.83.2.1.1.1.4 | ||||||||||||||||||||||||||||||||||
| entPhySensorOperStatusThe operational status of the sensor. | EntitySensorStatus Type Values:
| .1.3.6.1.4.1.11.2.83.2.1.1.1.5 | ||||||||||||||||||||||||||||||||||
| entPhySensorUnitsDisplayA textual description of the data units that should be used in the display of entPhySensorValue. | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.11.2.83.2.1.1.1.6 | ||||||||||||||||||||||||||||||||||
| entPhySensorValueTimeStampThe value of sysUpTime at the time the status and/or value of this sensor was last obtained by the agent. | SNMPv2-TCTimeStamp Based On: SNMPv2-SMITimeTicks Description: The value of the sysUpTime object at which a specific occurrence happened. The specific occurrence must be defined in the description of any object defined using this type. If sysUpTime is reset t… | .1.3.6.1.4.1.11.2.83.2.1.1.1.7 | ||||||||||||||||||||||||||||||||||
| entPhySensorValueUpdateRateAn indication of the frequency that the agent updates the associated entPhySensorValue object, representing in milliseconds. The value zero indicates: - the sensor value is updated on d… | millisecondsSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.11.2.83.2.1.1.1.8 |