HPE-ERRDISABLE-RECOVERY-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
2
Rows
2
Columns
5
.1.3.6.1.4.1.11.2.128.2 · 1 row entry · 2 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk rlErrdisableRecoveryCauseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HPE-ERRDISABLE-RECOVERY-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HPE-ERRDISABLE-RECOVERY-MIB::rlErrdisableRecoveryCauseTable'
The table is used to enable or disable auto-recovery for specific
application causes port suspend. The table includes entries for all applications.
rlErrdisableRecoveryCauseEntry row .1.3.6.1.4.1.11.2.128.2.1
An entry (conceptual row) in the rlErrdisableRecoveryCauseEntry.
Column Syntax OID
Type of recovery cause.
RlErrdisableRecoveryCauseType
Type Values:
1loopback-detection
2port-security
3dot1x-src-address
4acl-deny
5stp-bpdu-guard
6stp-loopback-guard
7pcb-overheat
8udld
9storm-control
10link-flapping
.1.3.6.1.4.1.11.2.128.2.1.1
Enable/Disable automatic recovery.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.11.2.128.2.1.2
.1.3.6.1.4.1.11.2.128.3 · 1 row entry · 3 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk rlErrdisableRecoveryIfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HPE-ERRDISABLE-RECOVERY-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HPE-ERRDISABLE-RECOVERY-MIB::rlErrdisableRecoveryIfTable'
The table is used for show the reason of shutdown the port in errdisable state.
The table includes only suspended interfaces.
rlErrdisableRecoveryIfEntry row .1.3.6.1.4.1.11.2.128.3.1
An entry (conceptual row) in the rlErrdisableRecoveryIfEntry.
Indexes
Column Syntax OID
The reason of shutdown the port in errdisable state.
RlErrdisableRecoveryCauseType
Type Values:
1loopback-detection
2port-security
3dot1x-src-address
4acl-deny
5stp-bpdu-guard
6stp-loopback-guard
7pcb-overheat
8udld
9storm-control
10link-flapping
.1.3.6.1.4.1.11.2.128.3.1.1
Enable/Disable automatic recovery status.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.11.2.128.3.1.2
Time in seconds left for automatic activation of an interface after shutdown,
calculated as (rlErrdisableRecoveryInterval - (port in down state time interval))
secondsInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.11.2.128.3.1.3