HM2-POE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
29
.1.3.6.1.4.1.248.11.12.1.1.2 · 1 row entry · 4 columns
Uses the hirschmann variant from /opt/observium/mibs/hirschmann.
Command help
Walk hm2PoeMgmtPsuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HM2-POE-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-POE-MIB::hm2PoeMgmtPsuTable'
This table contains objects for each power supply type of
the device (internal or external power supply).
hm2PoeMgmtPsuEntry row .1.3.6.1.4.1.248.11.12.1.1.2.1
The entries of the hm2PoeMgmtPsuTable.
Column Syntax OID
The power budget per psu type expressed in Watts. Psu types could
be internal or external.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.2.1.1
The reserved power (depending on actual power classes)
per psu type expressed in Watts.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.2.1.2
The measured usage power per psu type expressed in Watts.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.2.1.3
The measured current delivered per psu type expressed in milliamperes
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.2.1.4
.1.3.6.1.4.1.248.11.12.1.1.3 · 1 row entry · 15 columns
Uses the hirschmann variant from /opt/observium/mibs/hirschmann.
Command help
Walk hm2PoeMgmtPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HM2-POE-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-POE-MIB::hm2PoeMgmtPortTable'
This table contains objects for each Power over Ethernet interface of
the device.
hm2PoeMgmtPortEntry row .1.3.6.1.4.1.248.11.12.1.1.3.1
The entry of the hm2PoeMgmtPortTable.
Column Syntax OID
enable (1) An interface which can provide the PSE functions.
disable(2) The interface will act - as it would - if it had no PSE
function.
HM2-TC-MIBHmEnabledStatusr/w
Type Values:
1enable
2disable
.1.3.6.1.4.1.248.11.12.1.1.3.1.1
Measured usage power per interface expressed in Milliwatts.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.3.1.2
Describes the operational status of the port PD detection.
A value of disabled(1)- indicates that the PSE State diagram
is in the state DISABLED.
A value of deliveringPower(3) - indicates that the PSE State
diagram is i…
Enumeration
Enumerated Values:
1disabled
2searching
3deliveringPower
4fault
5test
6otherFault
.1.3.6.1.4.1.248.11.12.1.1.3.1.3
This object controls the priority of the port from the point
of view of a power management algorithm. The priority that
is set by this variable could be used by a control mechanism
that prevents over current situations…
Enumerationr/w
Enumerated Values:
1critical
2high
3low
.1.3.6.1.4.1.248.11.12.1.1.3.1.4
Classification is a way to tag different terminals on the
Power over LAN network according to their power consumption.
Devices such as IP telephones, WLAN access points and others,
will be classified according to their …
Enumeration
Enumerated Values:
1class0
2class1
3class2
4class3
5class4
.1.3.6.1.4.1.248.11.12.1.1.3.1.5
A manager will set the value of this variable to indicate
the type of powered device that is connected to the port.
The default value supplied by the agent if no value has
ever been set should be a zero-length octet str…
OctetStringr/w
Constraints:
range: 1-32
.1.3.6.1.4.1.248.11.12.1.1.3.1.6
Bit mask which defines allowed classes per interface.
Bitsr/w
Enumerated Values:
0class0
1class1
2class2
3class3
4class4
.1.3.6.1.4.1.248.11.12.1.1.3.1.7
Enables/disables automatic shutdown functionality per interface.
HM2-TC-MIBHmEnabledStatusr/w
Type Values:
1enable
2disable
.1.3.6.1.4.1.248.11.12.1.1.3.1.8
Start time for the automatic shutdown functionality per interface.
HM2-TC-MIBHmTimeHHMM24r/w
Type Constraints:
range: 0..5
.1.3.6.1.4.1.248.11.12.1.1.3.1.9
End time for the automatic shutdown functionality per interface.
HM2-TC-MIBHmTimeHHMM24r/w
Type Constraints:
range: 0..5
.1.3.6.1.4.1.248.11.12.1.1.3.1.10
Evaluates if class represented through pethPsePortPowerClassifications
is valid or not. Class is valid if PD is delivered with power or in case
of power exceeding through a connected device.
Enumeration
Enumerated Values:
0invalid
1valid
.1.3.6.1.4.1.248.11.12.1.1.3.1.11
Enables/disables Power over Ethernet fast startup mode on given port.
The default value is 'disable'.
HM2-TC-MIBHmEnabledStatusr/w
Type Values:
1enable
2disable
.1.3.6.1.4.1.248.11.12.1.1.3.1.12
The maximum observed power consumption (hm2PoeMgmtPortMaxConsumptionPower)
value expressed in milliwatts used by the PD.
The value is reset to 0 if the PoE admin state is set to disable
or if a disconnect of the PD is …
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.3.1.13
The power limit per port expressed in milliwatts. If set to
zero the power consumption limitation is disabled.
Integer32r/w
Constraints:
range: 0-30000
.1.3.6.1.4.1.248.11.12.1.1.3.1.14
Measured current consumption per interface expressed in milliamperes (mA).
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.3.1.15
.1.3.6.1.4.1.248.11.12.1.1.4 · 1 row entry · 10 columns
Uses the hirschmann variant from /opt/observium/mibs/hirschmann.
Command help
Walk hm2PoeMgmtModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HM2-POE-MIB' -M '/opt/observium/mibs/hirschmann:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HM2-POE-MIB::hm2PoeMgmtModuleTable'
This table contains objects for each plugged PoE module of
the device. If the device is non-modular and supports PoE it
contains only one entry.
hm2PoeMgmtModuleEntry row .1.3.6.1.4.1.248.11.12.1.1.4.1
The entries of the hm2PoeMgmtModuleTable.
Column Syntax OID
Unit number - for stacking devices.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.4.1.1
Slot number of the plugged PoE module.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.4.1.2
Configurable power budget per module expressed in Watts. The default
value is hm2PoeMgmtModuleMaximumPower and depends on the hardware.
Integer32r/w
Constraints:
range: 0-1000
.1.3.6.1.4.1.248.11.12.1.1.4.1.3
Maximum available power budget per module expressed in Watts. This
value depends on the device or module.
Integer32
Constraints:
range: 0-1000
.1.3.6.1.4.1.248.11.12.1.1.4.1.4
The reserved power (depending on actual power classes)
per module expressed in Watts.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.4.1.5
The measured usage power per module expressed in Watts.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.4.1.6
This object displays the type of the PoE power source.
internal (0) means that the PoE power is used from the internal PSU and
external (1) means that a external PoE PSU must be installed and connected to this module.
Enumeration
Enumerated Values:
0internal
1external
.1.3.6.1.4.1.248.11.12.1.1.4.1.7
The usage power threshold per module expressed in percent.
If this threshold is exceeded a alarm is initiated.
Integer32r/w
Constraints:
range: 1-99
.1.3.6.1.4.1.248.11.12.1.1.4.1.8
This object controls, on a per-module basis, whether
or not notifications from the agent are enabled.
HM2-TC-MIBHmEnabledStatusr/w
Type Values:
1enable
2disable
.1.3.6.1.4.1.248.11.12.1.1.4.1.9
The measured current consumption per module expressed in milliamperes (mA).
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.248.11.12.1.1.4.1.10