ipTHATable

table
.1.3.6.1.4.1.3711.24.1.1.1.2.2 · 1 row entry · 10 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk ipTHATable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::ipTHATable'
A table giving data for all enabled inputs with analogue-type monitoring.
ipTHAEntry row .1.3.6.1.4.1.3711.24.1.1.1.2.2.1
A conceptual row containing information about one analogue-type input.
Indexes
Column Syntax OID
The input number.
Integer32
Constraints:
range: 0-48
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.1
The analogue-type input table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.2
The name of this input
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.1.2.2.1.3
A system-defined name for the physical location of this input, e.g. MCU.
DisplayString .1.3.6.1.4.1.3711.24.1.1.1.2.2.1.4
Indicates that the type of data this input is monitoring is selected automatically.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.5
Indicates the type of data this input is monitoring.
InputDataType
Type Values:
1autodetect
2temperature
3humidity
4analogue
5contact
255inactive
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.6
The current reading in the relevant measurement units.
-999999999 - Input Data Uninitialised
-99999999 - Input Data Under Range
-17999680 - Temperature Data Under Range in F
-10000000 - Temperature Data Under Range i…
Integer32
Constraints:
range: -999999999--999999999
range: -99999999--99999999
range: -17999680--17999680
range: -10000000--10000000
range: -9997268--9997268
range: -580-120000
range: 10000000-10000000
range: 10002732-10002732
range: 18000320-18000320
range: 99999999-99999999
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.7
Scaling factor for ipTHAValue in units of 0.1 when ipTHAType=analogue.
Integer32r/w
Constraints:
range: 0-1
range: 10-10
range: 100-100
range: 1000-1000
range: 10000-10000
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.8
Calibration offset in the same units as for ipTHAValue.
Integer32r/w
Constraints:
range: -1479-2119
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.9
Hysteresis on threshold levels in the same units as for ipTHAValue.
Integer32r/w
Constraints:
range: -1479-2119
.1.3.6.1.4.1.3711.24.1.1.1.2.2.1.10
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1 · 1 row entry · 8 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk ipTHAThreshTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::ipTHAThreshTable'
A table listing the trap threshold levels for all enabled inputs with analogue-type monitoring.
ipTHAThreshEntry row .1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1
A conceptual row containing threshold information for one analogue-type input.
Indexes
Column Syntax OID
The input number.
Integer32
Constraints:
range: 0-48
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.1
The analogue-type input table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.2
The Upper Critical Limit for this input in the same units as for ipTHAValue.
Integer32r/w
Constraints:
range: -300-100000
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.3
The Upper Warning Limit for this input in the same units as for ipTHAValue.
Integer32r/w
Constraints:
range: -300-100000
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.4
The Lower Warning Limit for this input in the same units as for ipTHAValue.
Integer32r/w
Constraints:
range: -300-100000
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.5
The Lower Critical Limit for this input in the same units as for ipTHAValue.
Integer32r/w
Constraints:
range: -300-100000
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.6
Rising rate of change threshold for ipTHAValue in 0.1 units per minute.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.7
Falling rate of change threshold for ipTHAValue in 0.1 units per minute.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.1.2.3.1.1.8
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2 · 1 row entry · 8 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk ipTHATrapEnTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::ipTHATrapEnTable'
The table that controls trap enabling for all enabled inputs with analogue-type monitoring.
ipTHATrapEnEntry row .1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1
A conceptual row containing trap enabling information for one analogue-type input.
Indexes
Column Syntax OID
The input number.
Integer32
Constraints:
range: 0-48
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.1
The analogue-type input table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.2
Enables and disables input UCL alarm traps.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.3
Enables and disables input UWL alarm traps.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.4
Enables and disables input LWL alarm traps.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.5
Enables and disables input LCL alarm traps.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.6
Trap enable flag for ipTHADeltaPos.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.7
Trap enable flag for ipTHADeltaNeg.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.2.3.2.1.8
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3 · 1 row entry · 8 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk ipTHATrapPerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::ipTHATrapPerTable'
The table that controls trap repetition for all enabled inputs with analogue-type monitoring.
ipTHATrapPerEntry row .1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1
A conceptual row containing trap repetition information for one analogue-type input.
Column Syntax OID
The input number.
Integer32
Constraints:
range: 0-48
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.1
The table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.2
Trap repetition period for ipTHATrapUCL in seconds. A value of 0 disables trap repetition.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.3
Trap repetition period for ipTHATrapUWL in seconds. A value of 0 disables trap repetition.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.4
Trap repetition period for ipTHATrapLWL in seconds. A value of 0 disables trap repetition.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.5
Trap repetition period for ipTHATrapLCL in seconds. A value of 0 disables trap repetition.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.6
Trap repetition period for ipTHADeltaPos in seconds. A value of 0 disables trap repetition.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.7
Trap repetition period for ipTHADeltaNeg in seconds. A value of 0 disables trap repetition.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.2.3.3.1.8

ipContTable

table
.1.3.6.1.4.1.3711.24.1.1.1.3.1 · 1 row entry · 11 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk ipContTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::ipContTable'
A table listing the parameters and data for all enabled inputs with contact-type monitoring.
ipContEntry row .1.3.6.1.4.1.3711.24.1.1.1.3.1.1
A conceptual row containing information about one contact input.
Indexes
Column Syntax OID
The input number.
Integer32
Constraints:
range: 0-48
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.1
The contact input table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.2
The name of this input
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.1.3.1.1.3
A system-defined name for the physical location of this input, e.g. MCU.
DisplayString .1.3.6.1.4.1.3711.24.1.1.1.3.1.1.4
Indicates that the type of data this input is monitoring is selected automatically.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.5
The normal state for this contact.
ContactStater/w
Type Values:
1open
2closed
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.6
The current state of this contact.
InputContactState
Type Values:
1open
2closed
3armed
4triggered
255unknown
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.7
The contact trigger mode, level, +ve edge, -ve edge.
Enumerationr/w
Enumerated Values:
1positiveEdge
2negativeEdge
3level
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.8
Resets the contact after triggering in edge mode.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.9
Configure contact input traps.
Enumerationr/w
Enumerated Values:
1critical
2warning
3information
255disabled
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.10
Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds
Integer32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.1.3.1.1.11

opTable

table
.1.3.6.1.4.1.3711.24.1.1.2.2 · 1 row entry · 12 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk opTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::opTable'
A table listing the parameters and data for all outputs.
opEntry row .1.3.6.1.4.1.3711.24.1.1.2.2.1
A conceptual row containing information about one output.
Indexes
Column Syntax OID
The output number.
Integer32
Constraints:
range: 0-19
.1.3.6.1.4.1.3711.24.1.1.2.2.1.1
The contact input table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.2.2.1.2
A user-defined name for this output.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.2.2.1.3
A system-defined name for the physical location of this output, e.g. MCU.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.2.2.1.4
Sets or reads the required normal state of this output.
RelayStater/w
Type Values:
1on
2off
.1.3.6.1.4.1.3711.24.1.1.2.2.1.5
Reads the current state of this output.
RelayState
Type Values:
1on
2off
.1.3.6.1.4.1.3711.24.1.1.2.2.1.6
Sets the 'on' delay time for this output.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.2.2.1.7
Sets the 'off' delay time for this output.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.2.2.1.8
Boolean equation string
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.2.2.1.9
Configure output traps.
Enumerationr/w
Enumerated Values:
1critical
2warning
3information
255disabled
.1.3.6.1.4.1.3711.24.1.1.2.2.1.10
Set to 0 disables trap repetition, a value of 30 or higher sets the interval between traps in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.2.2.1.11
Reads the current control state of an output.
OutputControlStater/w
Type Values:
1activate
2deactivate
3logic
.1.3.6.1.4.1.3711.24.1.1.2.2.1.12

kpCtlTable

table
.1.3.6.1.4.1.3711.24.1.1.4.2 · 1 row entry · 10 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk kpCtlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::kpCtlTable'
A table listing the parameters and data for the keypads.
kpCtlEntry row .1.3.6.1.4.1.3711.24.1.1.4.2.1
A conceptual row containing information about one keypad.
Indexes
Column Syntax OID
The keypad number.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.3711.24.1.1.4.2.1.1
The keypad table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.4.2.1.2
The name of the manufacturer of the keypad.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.4.2.1.3
A name identifying the keypad.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.4.2.1.4
Time-out value in seconds for which the door latch is held open.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.4.2.1.5
Time-out value in seconds for Return to Standby Mode
Integer32r/w
Constraints:
range: 0-99
.1.3.6.1.4.1.3711.24.1.1.4.2.1.6
Set if previous keypad entry was valid.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.4.2.1.7
Time-out value in seconds for Door Open.
Integer32r/w
Constraints:
range: 0-99
.1.3.6.1.4.1.3711.24.1.1.4.2.1.8
Set to open the door.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.4.2.1.9
'keypad in use' trap enable
Enumerationr/w
Enumerated Values:
1critical
2warning
3information
255disabled
.1.3.6.1.4.1.3711.24.1.1.4.2.1.10

acuCtlTable

table
.1.3.6.1.4.1.3711.24.1.1.5.2 · 1 row entry · 13 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk acuCtlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::acuCtlTable'
A table listing the parameters and data for the ACUs.
acuCtlEntry row .1.3.6.1.4.1.3711.24.1.1.5.2.1
A conceptual row containing information about one ACU.
Indexes
Column Syntax OID
The ACU number.
Integer32
Constraints:
range: 1-6
.1.3.6.1.4.1.3711.24.1.1.5.2.1.1
The ACU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.5.2.1.2
The name of the manufacturer of the ACU.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.5.2.1.3
A name identifying the ACU.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.5.2.1.4
Time-out value in seconds for which the door latch is held open.
Unsigned32r/w
Constraints:
range: 0-999
.1.3.6.1.4.1.3711.24.1.1.5.2.1.5
Time-out value in seconds for Return to Standby Mode
Integer32r/w
Constraints:
range: 0-999
.1.3.6.1.4.1.3711.24.1.1.5.2.1.6
Set if previous ACU entry was valid.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.5.2.1.7
Time-out value in seconds for Door Open.
Integer32r/w
Constraints:
range: 0-3600
.1.3.6.1.4.1.3711.24.1.1.5.2.1.8
Set to open the door.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.5.2.1.9
'ACU in use' trap enable
Enumerationr/w
Enumerated Values:
1critical
2warning
3information
255disabled
.1.3.6.1.4.1.3711.24.1.1.5.2.1.10
A string identifying the ACU type.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.5.2.1.11
A bit field flagging ACU alarms.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.5.2.1.12
The last key code read from the ACU. After this is consumed, write an empty string to clear the contents.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.5.2.1.13

accUserTable

table
.1.3.6.1.4.1.3711.24.1.1.6.1.2 · 1 row entry · 6 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk accUserTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::accUserTable'
A table controlling the access users.
accUserEntry row .1.3.6.1.4.1.3711.24.1.1.6.1.2.1
A conceptual row containing information about one ACU user.
Indexes
Column Syntax OID
The the access user-table entry number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.6.1.2.1.1
The access user table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.6.1.2.1.2
A name identifying the access user.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.6.1.2.1.3
The user's access code.
OctetStringr/w
Constraints:
range: 0-15
.1.3.6.1.4.1.3711.24.1.1.6.1.2.1.4
The ACUs and keypads that the user is allowed to gain access through - comma-separated numerical strings.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.6.1.2.1.5
A text string which specifies when the access code in the row expires. The format is defined by the application.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.6.1.2.1.6

pduTable

table
.1.3.6.1.4.1.3711.24.1.1.7.1.2 · 1 row entry · 14 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduTable'
A table containing information about each enabled PDU.
pduEntry row .1.3.6.1.4.1.3711.24.1.1.7.1.2.1
A conceptual row containing information about one PDU.
Indexes
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.2
A string identifying the PDU.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.1.2.1.3
Enables/disables PDU power outlet control - causes an entry for outlets to be created in each relevant PDU table.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.4
Enables/disables PDU power monitoring - causes an entry for monitoring to be created in each relevant PDU table.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.5
Indicates comms. status for the PDU.
Enumeration
Enumerated Values:
1commsGood
2commsFailed
3commsBadData
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.6
Indicates the type of device connected.
Enumeration
Enumerated Values:
1rs232PduMk1
2rs232PduTpt
3rs485PduTpt
4rs232CLAmp
5rs485CLAmp
6rs232PduMk2
7rs485PduMk2
8rs485PduMk3
9rs232G5
253virtual
254none
255unknown
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.7
Indicates the phase circuit topology.
Enumeration
Enumerated Values:
1singlePhase
2twoPhase
3threePhaseStar
4threePhaseDelta
253aggregate
254none
255unknown
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.8
Indicates the number of controlled outlets.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.9
Indicates the monitor mode.
Enumeration
Enumerated Values:
1currentOnly
2allParameters
254none
255unknown
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.10
Indicates the number of monitored outlets.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.11
A string identifying the PDU processor firmware version.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.1.2.1.12
A string identifying the PDU meter firmware version.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.1.2.1.13
Indicates the number of monitored branch circuits.
Integer32r/w
Constraints:
range: 0-9
.1.3.6.1.4.1.3711.24.1.1.7.1.2.1.14
.1.3.6.1.4.1.3711.24.1.1.7.2.2 · 1 row entry · 7 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduOutCmnTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduOutCmnTable'
A table containing information about the power outlets of all PDUs enabled for outlet control.
pduOutCmnEntry row .1.3.6.1.4.1.3711.24.1.1.7.2.2.1
A conceptual row containing information about the power outlets of one PDU.
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.2.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.2.2.1.2
The number of switchable outlets on the PDU - determines the number of entries to be created in the outlet table for the relevant PDU.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.2.1.3
Sets the required state of all power outlets on the PDU.
Enumerationr/w
Enumerated Values:
1up
2down
255unknown
.1.3.6.1.4.1.3711.24.1.1.7.2.2.1.4
Password controling access to setting the required state of all power outlets on the PDU.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.2.2.1.5
Abort power outlet setting task.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.2.1.6
Time delay to abort power outlet setting task.
Unsigned32r/w
Constraints:
range: 0-60
.1.3.6.1.4.1.3711.24.1.1.7.2.2.1.7

pduOutTable

table
.1.3.6.1.4.1.3711.24.1.1.7.2.3 · 1 row entry · 21 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduOutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduOutTable'
A table listing the states and descriptions for each outlet on the PDU.
pduOutEntry row .1.3.6.1.4.1.3711.24.1.1.7.2.3.1
A row containing information about one PDU outlet.
Column Syntax OID
The PDU number on which the outlet resides.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.1
The outlet number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.2
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.3
A name identifying the outlet.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.2.3.1.4
The current state for this outlet.
Enumerationr/w
Enumerated Values:
1on
2off
3reboot
4unknown
5failedStuck
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.5
The password for this outlet.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.2.3.1.6
The on/off delay for this outlet in seconds.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.7
The pduOutOn reboot off period for this outlet in seconds.
Unsigned32
Constraints:
range: 5-300
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.8
RMS current value at the outlet in 0.1 Amps
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.9
Maximum value of pduOutRMSAmpsValue for another outlet to be switched on in 0.1 Amps
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.10
Maximum value of pduOutRMSAmpsValue since reset in 0.1 Amps
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.11
Resets value of pduOutRMSAmpsPeak to current value of pduOutRMSAmpsValue
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.12
Mean kVA value at the outlet in 0.1 kVA
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.13
kWhr value at the outlet in 0.1 kWhr
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.14
Power factor value at the outlet in 0.01 units
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.15
Upper threshold of pduOutRMSAmpsValue in 0.1 Amps
Integer32r/w
Constraints:
range: -10-500
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.16
Lower threshold of pduOutRMSAmpsValue in 0.1 Amps
Integer32r/w
Constraints:
range: -10-500
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.17
Trap enable flag for pduOutRMSAmpsUTL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.18
Trap enable flag for pduOutRMSAmpsLTL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.19
Trap repetition period for pduOutRMSAmpsUTL.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.20
Trap repetition period for pduOutRMSAmpsLTL.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.2.3.1.21

pduMonTable

table
.1.3.6.1.4.1.3711.24.1.1.7.3.1 · 1 row entry · 37 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduMonTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduMonTable'
A table containing monitor information for all PDUs enabled for monitoring.
pduMonEntry row .1.3.6.1.4.1.3711.24.1.1.7.3.1.1
A conceptual row containing monitor information for one PDU.
Indexes
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.2
RMS Volts across load in Volts
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.3
RMS current through load in 0.1 Amps
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.4
Total energy supplied to load in 0.1 kWh
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.5
Kilo Volt-Amperes supplied to load in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.6
Kilo Watts supplied to load in 0.1 kW
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.7
Power factor of load in 0.01
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.8
Power supply frequency in 0.1Hz
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.9
RMS Volts across phase in Volts
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.10
RMS current supplied by phase in 0.1 Amps
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.11
Total energy supplied by phase in 0.1 kWh
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.12
Apparent power supplied by phase in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.13
True power supplied by phase in 0.1 kW
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.14
Power factor of phase in 0.01
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.15
A string identifying the circuit.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.16
Maximum apparent power in circuit for measurment period in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.17
Timestamp for maximum apparent power in circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.18
Minimum apparent power in circuit for measurment period in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.19
Timestamp for mniimum apparent power in circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.20
Maximum current in circuit for measurment period in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.21
Timestamp for maximum current in circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.22
Minimum current in circuit for measurment period in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.23
Timestamp for minimum current in circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.24
Sag status is set in this circuit
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.25
Sag status count in this circuit
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.26
Timestamp for sag status in this circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.27
Peak Volts status is set in this circuit
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.28
Peak Volts status count in this circuit
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.29
Timestamp for Peak Volts status in this circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.30
Power Loss status is set in this circuit
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.31
Power Loss status count in this circuit
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.32
Timestamp for Power Loss status in this circuit
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.33
Maximum apparent power in circuit since last reset in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.34
Timestamp for maximum apparent power in circuit since last reset
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.35
Minimum apparent power in circuit since last reset in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.1.1.36
Timestamp for minimum apparent power in circuit since last reset
DisplayString .1.3.6.1.4.1.3711.24.1.1.7.3.1.1.37
.1.3.6.1.4.1.3711.24.1.1.7.3.2 · 1 row entry · 22 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduTrapThreshTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduTrapThreshTable'
A table containing information about the trap threshold values for all PDUs enabled for monitoring.
pduTrapThreshEntry row .1.3.6.1.4.1.3711.24.1.1.7.3.2.1
A conceptual row containing information about the trap threshold values for one PDU.
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.2
rms UCL value in volts
Integer32r/w
Constraints:
range: -10-500
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.3
rms UWL value in volts
Integer32r/w
Constraints:
range: -10-500
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.4
rms LWL value in volts
Integer32r/w
Constraints:
range: -10-500
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.5
rms LCL value in volts
Integer32r/w
Constraints:
range: -10-500
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.6
rms UCL value in 0.1 amps
Integer32r/w
Constraints:
range: -10-5000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.7
rms UWL value in 0.1 amps
Integer32r/w
Constraints:
range: -10-5000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.8
rms LWL value in 0.1 amps
Integer32r/w
Constraints:
range: -10-5000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.9
rms LCL value in 0.1 amps
Integer32r/w
Constraints:
range: -10-5000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.10
Total energy UCL value in 0.1 kWh
Unsigned32r/w
Constraints:
range: 0-4294967290
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.11
Total energy UWL value in 0.1 kWh
Unsigned32r/w
Constraints:
range: 0-4294967290
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.12
Mean kVA UCL value in 0.1 kVA
Integer32r/w
Constraints:
range: 0-999990
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.13
Mean kVA UWL value in 0.1 kVA
Integer32r/w
Constraints:
range: 0-999990
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.14
Mean kVA LWL value in 0.1 kVA
Integer32r/w
Constraints:
range: 0-999990
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.15
Mean kVA LCL value in 0.1 kVA
Integer32r/w
Constraints:
range: 0-999990
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.16
Mean power UCL value in 0.1 kW
Integer32r/w
Constraints:
range: 0-100000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.17
Mean power UWL value in 0.1 kW
Integer32r/w
Constraints:
range: 0-100000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.18
Mean power LWL value in 0.1 kW
Integer32r/w
Constraints:
range: 0-100000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.19
Mean power LCL value in 0.1 kW
Integer32r/w
Constraints:
range: 0-100000
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.20
Power factor UTL value in 0.01
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.21
Power factor LTL value in 0.01
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.3711.24.1.1.7.3.2.1.22
.1.3.6.1.4.1.3711.24.1.1.7.3.3 · 1 row entry · 22 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduTrapEnTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduTrapEnTable'
The table which controls threshold value trap enabling for all PDUs enabled for monitoring.
pduTrapEnEntry row .1.3.6.1.4.1.3711.24.1.1.7.3.3.1
A conceptual row containing information about one PDU.
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.2
Enables Volts UCL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.3
Enables UWL Volts trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.4
Enables LWL Volts trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.5
Enables LCL Volts trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.6
Enables UCL current trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.7
Enables UWL current trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.8
Enables LWL current trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.9
Enables LCL current trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.10
Enables UCL total energy trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.11
Enables UWL total energy trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.12
Enables mean kVA UCL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.13
Enables mean kVA UWL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.14
Enables mean kVA LWL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.15
Enables mean kVA LCL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.16
Enables mean power UCL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.17
Enables mean power UWL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.18
Enables mean power LWL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.19
Enables mean power LCL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.20
Enables power factor UTL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.21
Enables power factor LTL trap.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.7.3.3.1.22
.1.3.6.1.4.1.3711.24.1.1.7.3.4 · 1 row entry · 22 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduTrapPerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduTrapPerTable'
The table which controls threshold value trap repetition for all PDUs enabled for monitoring.
pduTrapPerEntry row .1.3.6.1.4.1.3711.24.1.1.7.3.4.1
A conceptual row containing information about one PDU.
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.2
Sets UCL Volts trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.3
Sets UWL Volts trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.4
Sets LWL Volts trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.5
Sets LCL Volts trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.6
Sets UCL current trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.7
Sets UWL current trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.8
Sets LWL current trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.9
Sets LCL current trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.10
Sets UCL total energy trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.11
Sets UWL total energy trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.12
Sets mean kVA UCL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.13
Sets mean kVA UWL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.14
Sets mean kVA LWL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.15
Sets mean kVA LCL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.16
Sets mean power UCL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.17
Sets mean power UWL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.18
Sets mean power LWL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.19
Sets mean power LCL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.20
Sets power factor UTL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.21
Sets power factor LTL trap repeat rate in seconds
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.7.3.4.1.22
.1.3.6.1.4.1.3711.24.1.1.7.3.5 · 1 row entry · 14 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduMon3PhTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduMon3PhTable'
A table containing monitor information for all 3-phase PDUs enabled for monitoring.
pduMon3PhEntry row .1.3.6.1.4.1.3711.24.1.1.7.3.5.1
A conceptual row containing monitor information for one 3-phase PDU.
Indexes
Column Syntax OID
The PDU number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.2
Three phase topology
Enumeration
Enumerated Values:
1star
2delta
253aggregate
254none
255unknown
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.3
Line RMS Volts value in volts
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.4
Phase RMS current value in 0.1 Amps
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.5
Line RMS Volts value in volts
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.6
Phase RMS current value in 0.1 Amps
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.7
Line RMS Volts value in volts
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.8
Phase RMS current value in 0.1 Amps
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.9
Total RMS current value in 0.1 Amps
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.10
Total apparent power value in 0.1 kVA
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.11
Total true power value in 0.1 kVW
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.12
Total re-active energy value in 0.1 kVArh
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.13
Total true energy value in 0.1 kWh
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.3.5.1.14

pduGangTable

table
.1.3.6.1.4.1.3711.24.1.1.7.4.2 · 1 row entry · 8 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduGangTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduGangTable'
A table containing information about each pdu gang.
pduGangEntry row .1.3.6.1.4.1.3711.24.1.1.7.4.2.1
A conceptual row containing information about one pdu gang.
Indexes
Column Syntax OID
The pdu gang number.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.1
The gang table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.2
Shows whether the gang is enabled(1), disabled(2) or suspended(3) this may have been disabled
by the application e.g. disabled pdu's in the gang, or bad pdu outlet CRC.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
3suspended
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.3
The name of this gang.
OctetStringr/w
Constraints:
range: 0-32
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.4
The current state for this gang.
Only states 1(on) ,2(off) and 4(reboot) can be set.
Enumerationr/w
Enumerated Values:
1on
2off
3mixed
4reboot
5na
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.5
The password required to control this gang.
OctetStringr/w
Constraints:
range: 0-16
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.6
Abort gang setting task.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.7
A string representing the members of a gang.
The format is PDU:OUTLET; e.g. 1:3;4:2;5:12;3:18; up to 6 member pairs
OctetStringr/w
Constraints:
range: 0-37
.1.3.6.1.4.1.3711.24.1.1.7.4.2.1.8

expTable

table
.1.3.6.1.4.1.3711.24.1.1.8.2 · 1 row entry · 5 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk expTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::expTable'
A table containing information about each enabled Expansion Port.
expEntry row .1.3.6.1.4.1.3711.24.1.1.8.2.1
A conceptual row containing information about one Expansion Port.
Indexes
Column Syntax OID
The Expansion Port number; maps to the specific Expansion Port connector.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.3711.24.1.1.8.2.1.1
The Expansion Port table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.8.2.1.2
A string identifying the Expansion Port.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.8.2.1.3
Indicates the External Unit type.
ExternalUnitTyper/w
Type Values:
0unknown
1acu
2keypad
3pduEU
4enviroHawk2
5idm
253autoWithTraps
254auto
255inactive
.1.3.6.1.4.1.3711.24.1.1.8.2.1.4
Indicates Comms. Status for the Expansion Port.
Enumeration
Enumerated Values:
1commsGood
2commsFailed
3commsBadData
.1.3.6.1.4.1.3711.24.1.1.8.2.1.5

clampTable

table
.1.3.6.1.4.1.3711.24.1.1.9.1 · 1 row entry · 7 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk clampTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::clampTable'
A table containing information about each detected CL-amp unit.
clampEntry row .1.3.6.1.4.1.3711.24.1.1.9.1.1
A conceptual row containing information about one CL-amp unit.
Indexes
Column Syntax OID
The CL-Amp number; maps to the specific CL-Amp Port.
Integer32
Constraints:
range: 1-24
.1.3.6.1.4.1.3711.24.1.1.9.1.1.1
The CL-Amp table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.9.1.1.2
Stores the value of the CL-amp unit B Value configuration. This may have been set
by the management station or read from the CL-amp unit depending on recent history.
Value is x 1000.
Unsigned32r/w
Constraints:
range: 20000-150000
.1.3.6.1.4.1.3711.24.1.1.9.1.1.3
Stores the value of the CL-amp unit Volts configuration. This may have been set
by the management station or read from the CL-amp unit depending on recent history.
Value is in Volts.
Unsigned32r/w
Constraints:
range: 90-250
.1.3.6.1.4.1.3711.24.1.1.9.1.1.4
Stores the value of the CL-amp unit Power Factor configuration. This may have been set
by the management station or read from the CL-amp unit depending on recent history.
Value is x100.
Unsigned32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.3711.24.1.1.9.1.1.5
Stores the value of the CL-amp unit Frequency configuration. This may have been set
by the management station or read from the CL-amp unit depending on recent history.
Value is Hz x10.
Unsigned32r/w
Constraints:
range: 450-650
.1.3.6.1.4.1.3711.24.1.1.9.1.1.6
When written to, sends the configuration values stored in this table for writing to the CL-amp unit.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.9.1.1.15

idmTable

table
.1.3.6.1.4.1.3711.24.1.1.10.1 · 1 row entry · 4 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk idmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::idmTable'
A table containing information about IDMs
idmEntry row .1.3.6.1.4.1.3711.24.1.1.10.1.1
A conceptual row containing information about one IDM.
Indexes
Column Syntax OID
The IDM number; maps to the specific IDM Port.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.3711.24.1.1.10.1.1.1
The IDM table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.10.1.1.2
Version information returned by the IDM.
DisplayString .1.3.6.1.4.1.3711.24.1.1.10.1.1.3
Indicates status of the IDM.
Enumeration
Enumerated Values:
1enabled
2disabled
255unknown
.1.3.6.1.4.1.3711.24.1.1.10.1.1.4
.1.3.6.1.4.1.3711.24.1.1.11.1.1 · 1 row entry · 26 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pduP2BrCctMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pduP2BrCctMonitorTable'
A table giving branch circuit monitoring information for all PDUs.
pduP2BrCctMonitorEntry row .1.3.6.1.4.1.3711.24.1.1.11.1.1.1
A conceptual row containing information about branch circuit monitoring.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.1
The PDU Branch Circuit Number.
Unsigned32
Constraints:
range: 1-9
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.2
The branch circuit monitor table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.3
The PDU Branch Circuit ID.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.11.1.1.1.4
The PDU Branch Circuit Phases.
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.11.1.1.1.5
The PDU Branch Circuit Current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.6
The PDU Branch Circuit Peak Current. The value precision is hundredths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.7
The PDU Branch Circuit Peak Current Timestamp.
UnsignedTimeTicks .1.3.6.1.4.1.3711.24.1.1.11.1.1.1.8
The PDU Branch Circuit Breaker Status.
BranchCircuitStatusType
Type Values:
1closeOn
2openOff
255invalidFeature
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.9
The PDU Branch Circuit Breaker Config.
BranchCircuitConfigTyper/w
Type Values:
1closeOn
2openOff
255invalidFeature
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.10
The PDU Branch Circuit Breaker Trip State.
BranchCircuitStatusType
Type Values:
1closeOn
2openOff
255invalidFeature
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.11
The PDU Branch Circuit Breaker Continuous Load Rating Amps.The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
Unsigned32r/w
Constraints:
range: 1-100000
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.12
The PDU Branch Circuit Breaker Trip Rating Amps. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
Unsigned32r/w
Constraints:
range: 1-100000
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.13
A string representing the outlets of a branch circuit.
The format is comma separated list of outlets; e.g. 8,9,10,11,12
DisplayStringr/w .1.3.6.1.4.1.3711.24.1.1.11.1.1.1.14
Circuit Current UCL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
Integer32r/w
Constraints:
range: -1000-100000
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.15
Circuit Current UWL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
Integer32r/w
Constraints:
range: -1000-100000
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.16
Circuit Current LWL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
Integer32r/w
Constraints:
range: -1000-100000
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.17
Circuit Current LCL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
Integer32r/w
Constraints:
range: -1000-100000
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.18
Trap enable flag for pduP2BrCktCircuitCurrentUCL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.19
Trap enable flag for pduP2BrCktCircuitCurrentUWL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.20
Trap enable flag for pduP2BrCktCircuitCurrentLWL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.21
Trap enable flag for pduP2BrCktCircuitCurrentLCL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.22
Trap repetition period for pduP2BrCktCircuitCurrentUCL.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.23
Trap repetition period for pduP2BrCktCircuitCurrentUWL.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.24
Trap repetition period for pduP2BrCktCircuitCurrentLWL.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.25
Trap repetition period for pduP2BrCktCircuitCurrentLCL.
Unsigned32r/w
Constraints:
range: 0-65535
.1.3.6.1.4.1.3711.24.1.1.11.1.1.1.26

pdu2Table

table
.1.3.6.1.4.1.3711.24.2.1.1.1.1 · 1 row entry · 4 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2Table'
A table giving data for all PDUs.
pdu2Entry row .1.3.6.1.4.1.3711.24.2.1.1.1.1.1
A conceptual row containing information about all PDUs.
Indexes
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.1.1.1
The PDU table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.1.1.2
The PDU wiring topology description.
WiringTopologyType
Type Values:
1disabled
2singlePhase
3twoPhase
4threePhaseStar
5threePhaseDelta
6deltaWithNeutral
254none
255unknown
.1.3.6.1.4.1.3711.24.2.1.1.1.1.1.3
The PDU phase topology description.
DisplayStringr/w .1.3.6.1.4.1.3711.24.2.1.1.1.1.1.4
.1.3.6.1.4.1.3711.24.2.1.1.1.2 · 1 row entry · 6 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2CustDataTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2CustDataTable'
A table giving customer entered metadata for all PDUs
pdu2CustDataEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.2.1
A conceptual row containing information about customer metadata.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.2.1.1
The customer metadata table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.2.1.2
Overall reference string
CktRefNamer/w
Type Constraints:
range: 0..31
.1.3.6.1.4.1.3711.24.2.1.1.1.2.1.3
Circuit-A reference string
CktRefNamer/w
Type Constraints:
range: 0..31
.1.3.6.1.4.1.3711.24.2.1.1.1.2.1.4
Circuit-B reference string
CktRefNamer/w
Type Constraints:
range: 0..31
.1.3.6.1.4.1.3711.24.2.1.1.1.2.1.5
Circuit-C reference string
CktRefNamer/w
Type Constraints:
range: 0..31
.1.3.6.1.4.1.3711.24.2.1.1.1.2.1.6
.1.3.6.1.4.1.3711.24.2.1.1.1.3 · 1 row entry · 9 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2InputAggregateTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2InputAggregateTable'
A table giving input aggregation information for all PDUs.
pdu2InputAggregateEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.3.1
A conceptual row containing information about input aggregation.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.1
The input aggregate table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.2
The PDU Aggregate kWh. The value precision is hundredths e.g. a value of 101 is 1.01 kWh.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.3
The PDU Aggregate kVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.4
The PDU Aggregate kW. The value precision is hundredths e.g. a value of 101 is 1.01 kW.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.5
The PDU Aggregate PF. The value precision is thousandths e.g. a value of 1001 is 1.001 PF.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.6
The PDU Aggregate Current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.7
The PDU Aggregate Neutral Current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.8
The PDU Aggregate Earth Current. The value precision is thousandths e.g. a value of 101 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.3.1.9
.1.3.6.1.4.1.3711.24.2.1.1.1.4 · 1 row entry · 15 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2PhaseMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2PhaseMonitorTable'
A table giving phase monitoring information data for all PDUs
pdu2PhaseMonitorEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.4.1
A conceptual row containing information about phase monitoring.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.1
The PDU phase Number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.2
The phase monitor table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.3
The PDU Line ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.4.1.4
The PDU Phase To Neutral Voltage. The value precision is tenths e.g. a value of 101 is 10.1 V.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.5
The PDU Phase Current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.6
The PDU Phase kVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.7
The PDU Phase Peak KVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.8
The PDU Phase Peak KVA Timestamp.
UnsignedTimeTicks .1.3.6.1.4.1.3711.24.2.1.1.1.4.1.9
The PDU Phase hkW. The value precision is hundredths e.g. a value of 101 is 1.01 kW.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.10
The PDU Phase PF. The value precision is thousandths e.g. a value of 1001 is 1.001 PF.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.11
The PDU Phase hkWh. The value precision is hundredths e.g. a value of 101 is 1.01 kWh.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.12
The PDU Phase kVAr. The value precision is hundredths e.g. a value of 101 is 1.01 kVAr.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.13
The PDU Phase Crest Factor. The value precision is thousandths of percent e.g. a value of 999 is 99.9%.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.14
The PDU Phase THD (Total Harmonic Distortion). The value precision is thousandths of percent e.g. a value of 999 is 99.9%.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.4.1.15
.1.3.6.1.4.1.3711.24.2.1.1.1.5 · 1 row entry · 12 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2CircuitMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2CircuitMonitorTable'
A table giving circuit monitoring information for all PDUs.
pdu2CircuitMonitorEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.5.1
A conceptual row containing information about circuit monitoring.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.1
The PDU Circuit Number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.2
The circuit monitor table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.3
The PDU Line ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.5.1.4
The PDU Circuit To Neutral Voltage. The value precision is tenths e.g. a value of 101 is 10.1 V.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.5
The PDU Circuit Current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.6
The PDU Circuit kVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.7
The PDU Circuit Peak KVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.8
The PDU Circuit Peak hKVA Timestamp.
UnsignedTimeTicks .1.3.6.1.4.1.3711.24.2.1.1.1.5.1.9
The PDU Circuit hkW. The value precision is hundredths e.g. a value of 101 is 1.01 kW.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.10
The PDU Circuit PF. The value precision is thousandths e.g. a value of 1001 is 1.001 PF.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.11
The PDU Circuit kVAr. The value precision is hundredths e.g. a value of 101 is 1.01 kVAr.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.5.1.12
.1.3.6.1.4.1.3711.24.2.1.1.1.6 · 1 row entry · 13 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2BranchCircuitMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2BranchCircuitMonitorTable'
A table giving branch circuit monitoring information for all PDUs.
pdu2BranchCircuitMonitorEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.6.1
A conceptual row containing information about branch circuit monitoring.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.1
The PDU Branch Circuit Number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.2
The branch circuit monitor table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.3
The PDU Branch Circuit ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.6.1.4
The PDU Branch Circuit Phases.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.6.1.5
The PDU Branch Circuit Current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.6
The PDU Branch Circuit Peak Current. The value precision is hundredths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.7
The PDU Branch Circuit Peak Current Timestamp.
UnsignedTimeTicks .1.3.6.1.4.1.3711.24.2.1.1.1.6.1.8
The PDU Branch Circuit Breaker Status.
BranchCircuitStatusType
Type Values:
1closeOn
2openOff
255invalidFeature
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.9
The PDU Branch Circuit Breaker Config.
BranchCircuitConfigTyper/w
Type Values:
1closeOn
2openOff
255invalidFeature
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.10
The PDU Branch Circuit Breaker Trip State.
BranchCircuitStatusType
Type Values:
1closeOn
2openOff
255invalidFeature
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.11
The PDU Branch Circuit Breaker Continuous Load Rating Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.12
The PDU Branch Circuit Breaker Trip Rating Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.6.1.13
.1.3.6.1.4.1.3711.24.2.1.1.1.7 · 1 row entry · 14 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2OutletMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2OutletMonitorTable'
A table giving outlet monitoring information for all PDUs.
pdu2OutletMonitorEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.7.1
A conceptual row containing information about outlet monitoring.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.1
The PDU outlet number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.2
The outlet monitor table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.3
The PDU outlet ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.7.1.4
The PDU outlet voltage. The value precision is tenths e.g. a value of 101 is 1.01 V.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.5
The PDU outlet current. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.6
The PDU outlet kVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.7
The PDU outlet peak kVA. The value precision is hundredths e.g. a value of 101 is 1.01 kVA.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.8
The PDU outlet peak kVA timestamp.
UnsignedTimeTicks .1.3.6.1.4.1.3711.24.2.1.1.1.7.1.9
The PDU outlet hkW. The value precision is hundredths e.g. a value of 101 is 1.01 kW.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.10
The PDU outlet PF. The value precision is thousandths e.g. a value of 1001 is 1.001 PF.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.11
The PDU outlet kWh. The value precision is hundredths e.g. a value of 101 is 1.01 kWh.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.7.1.12
The PDU outlet circuit ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.7.1.13
The PDU outlet phase ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.7.1.14
.1.3.6.1.4.1.3711.24.2.1.1.1.8 · 1 row entry · 7 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2OutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2OutletControlTable'
A table giving outlet control information for all PDUs.
pdu2OutletControlEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.8.1
A conceptual row containing information about outlet control.
Column Syntax OID
The PDU index number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.8.1.1
The PDU outlet number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.8.1.2
The outlet control table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.8.1.3
The PDU controlled outlet ID.
DisplayString .1.3.6.1.4.1.3711.24.2.1.1.1.8.1.4
The PDU controlled outlet state.
ControlledOutletStatusType
Type Values:
1on
2off
3lastKnownState
4timeDelayOn
.1.3.6.1.4.1.3711.24.2.1.1.1.8.1.5
The PDU controlled outlet power up state.
ControlledOutletStatusType
Type Values:
1on
2off
3lastKnownState
4timeDelayOn
.1.3.6.1.4.1.3711.24.2.1.1.1.8.1.6
The PDU controlled outlet power up time delay.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.8.1.7
.1.3.6.1.4.1.3711.24.2.1.1.1.9 · 1 row entry · 7 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2BranchCircuitThreshTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2BranchCircuitThreshTable'
A table listing the alarm threshold information for each branch circuit.
pdu2BranchCircuitThreshEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.9.1
A conceptual row containing alarm threshold information about one branch circuit.
Column Syntax OID
The number of the PDU on which the branch circuit resides.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.1
The branch circuit number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.2
The table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.3
Branch Circuit Current UCL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.4
Branch Circuit Current UWL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.5
Branch Circuit Current LWL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.6
Branch Circuit Current LCL. The value precision is thousandths e.g. a value of 1001 is 1.001 Amps.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.9.1.7
.1.3.6.1.4.1.3711.24.2.1.1.1.10 · 1 row entry · 7 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2BranchCircuitTrapEnTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2BranchCircuitTrapEnTable'
A table listing the trap enabling information for each branch circuit.
pdu2BranchCircuitTrapEnEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.10.1
A conceptual row containing trap enabling information about one branch circuit.
Column Syntax OID
The number of the PDU on which the branch circuit resides.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.1
The branch circuit number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.2
The table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.3
Trap enable flag for pdu2BrCktBranchCircuitCurrentUCL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.4
Trap enable flag for pdu2BrCktBranchCircuitCurrentUWL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.5
Trap enable flag for pdu2BrCktBranchCircuitCurrentLWL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.6
Trap enable flag for pdu2BrCktBranchCircuitCurrentLCL.
SNMPv2-TCTruthValuer/w
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.3711.24.2.1.1.1.10.1.7
.1.3.6.1.4.1.3711.24.2.1.1.1.11 · 1 row entry · 7 columns
Uses the panduit variant from /opt/observium/mibs/panduit.
Command help
Walk pdu2BranchCircuitTrapPerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'HAWK-I2-MIB' -M '/opt/observium/mibs/panduit:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HAWK-I2-MIB::pdu2BranchCircuitTrapPerTable'
A table listing the trap repetition periods for each branch circuit on the PDUs.
pdu2BranchCircuitTrapPerEntry row .1.3.6.1.4.1.3711.24.2.1.1.1.11.1
A conceptual row containing trap repetition periods for one branch circuit.
Column Syntax OID
The number of the PDU on which the branch circuit resides.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.1
The outlet number.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.2
The table row status.
SNMPv2-TCRowStatus
Type Values:
1active
2notInService
3notReady
4createAndGo
5createAndWait
6destroy
Description:
The RowStatus textual convention is used to manage the
creation and deletion of conceptual rows, and is used as the
value of the SYNTAX clause for the status column of a
conceptual row (as described in Section 7.7.1 of …
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.3
Trap repetition period for pdu2BrCktBranchCircuitCurrentUCL.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.4
Trap repetition period for pdu2BrCktBranchCircuitCurrentUWL.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.5
Trap repetition period for pdu2BrCktBranchCircuitCurrentLWL.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.6
Trap repetition period for pdu2BrCktBranchCircuitCurrentLCL.
SNMPv2-SMIUnsigned32r/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.3711.24.2.1.1.1.11.1.7