H3C-ENTITY-EXT-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
54
h3cEntityExtStateTable
table.1.3.6.1.4.1.2011.10.2.6.1.1.1
·
1 row entry
·
34 columns
Uses the h3c variant from
Command help
/opt/observium/mibs/h3c.
Walk h3cEntityExtStateTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'H3C-ENTITY-EXT-MIB' -M '/opt/observium/mibs/h3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'H3C-ENTITY-EXT-MIB::h3cEntityExtStateTable'
This table contains one row per physical entity, There is always at least one row for an 'overall' physical entity. The information in each row may be not include all the object in this table, because of the entity need not some of the information here.
The information about a particular physical entity.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The index of h3cEntityExtStateTable.
This index is identical to entPhysicalIndex in ENTITY-MIB |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.1 |
||||||||||||||||||||||||||||||||||
|
The administrative state for this object.
|
H3cAdminStater/w Type Values:
|
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.2 |
||||||||||||||||||||||||||||||||||
|
The operate state for this object.
|
H3cOperState Type Values:
|
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.3 |
||||||||||||||||||||||||||||||||||
|
This object is used for monitoring standby status.
Not all entities support this object. |
H3cStandbyStatus Type Values:
|
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.4 |
||||||||||||||||||||||||||||||||||
|
The alarm status for this entity. It does not include
the severity of alarms raised on child components. In this condition, there will be a alarm light on the entity, the object should have the same status with it. |
H3cAlarmStatus Type Values:
|
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.5 |
||||||||||||||||||||||||||||||||||
|
The CPU usage for this entity. Generally, the overall
CPU usage on the entity is calculated, independent of the number of CPUs on the entity. |
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.6 |
||||||||||||||||||||||||||||||||||
|
The threshold for the CPU usage. When the CPU usage exceeds
the threshold, a notification will be sent. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.7 |
||||||||||||||||||||||||||||||||||
|
The memory usage for the entity. This object indicates what
percent of memory are used. |
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.8 |
||||||||||||||||||||||||||||||||||
|
The threshold for the Memory usage, When the memory usage
exceeds the threshold, a notification will be sent. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.9 |
||||||||||||||||||||||||||||||||||
|
The size of memory for the entity.
If the amount of memory exceeds 4,294,967,295 bytes, the value remains 4,294,967,295 bytes. |
bytesSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.10 |
||||||||||||||||||||||||||||||||||
|
The uptime for the entity. The meaning of uptime is
when the entity is up, and the value of the object will add 1 seconds while the entity is running. |
secondsSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.11 |
||||||||||||||||||||||||||||||||||
|
The temperature for the entity.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.12 |
||||||||||||||||||||||||||||||||||
|
The threshold for the temperature. When the temperature
exceeds the threshold, a notification will be sent. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.13 |
||||||||||||||||||||||||||||||||||
|
The voltage for the entity.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.14 |
||||||||||||||||||||||||||||||||||
|
The low-threshold for the voltage.
When voltage is lower than low-threshold, a notification will be sent. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.15 |
||||||||||||||||||||||||||||||||||
|
The high-threshold for the voltage.
When voltage greater than high-threshold, a notification will be sent. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.16 |
||||||||||||||||||||||||||||||||||
|
The threshold for the critical Temperature. When temperature
exceeds the critical temperature, a notification will be sent. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.17 |
||||||||||||||||||||||||||||||||||
|
MAC Address of the entity.
|
SNMPv2-TCMacAddress Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.18 |
||||||||||||||||||||||||||||||||||
|
Indicate the error state of this entity object. Now it only
supports Port, general power supply, RPS power supply and board/Subcard. It may have one of these values. The following four values can be used for all kinds … |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.19 |
||||||||||||||||||||||||||||||||||
|
The maximal CPU usage for the entity in the period of time.
|
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.20 |
||||||||||||||||||||||||||||||||||
|
The threshold for the lower Temperature. When temperature runs
under the threshold, a notification will be sent. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.21 |
||||||||||||||||||||||||||||||||||
|
The threshold for the shutdown Temperature. When temperature
exceeds the threshold, a notification will be sent and the entity will be shutdown. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.22 |
||||||||||||||||||||||||||||||||||
|
The memory size of entity. This is the physical attribute of entity.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.23 |
||||||||||||||||||||||||||||||||||
|
The CPU frequency of entity. Unit of measure is MHZ.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.24 |
||||||||||||||||||||||||||||||||||
|
The first used date of the entity.
|
OctetString Constraints: range: 8-8 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.25 |
||||||||||||||||||||||||||||||||||
|
The average CPU usage for the entity in a period of time.
|
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.26 |
||||||||||||||||||||||||||||||||||
|
The average memory usage for the entity in a period of time.
|
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.27 |
||||||||||||||||||||||||||||||||||
|
The memory type of entity.
|
OctetString Constraints: range: 0-64 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.28 |
||||||||||||||||||||||||||||||||||
|
The threshold for the critical Temperature. When temperature
exceeds the critical lower temperature, a notification will be sent. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.29 |
||||||||||||||||||||||||||||||||||
|
The threshold for the shutdown Temperature. When temperature
exceeds the lower threshold, a notification will be sent and the entity will be shutdown. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.30 |
||||||||||||||||||||||||||||||||||
|
The recover threshold for the CPU usage. When the CPU usage falls down to
the threshold, a notification is sent. The h3cEntityExtCpuUsageRecoverThreshold must be less than or equal to the h3cEntityExtCpuUsageThreshold. |
Integer32r/w Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.31 |
||||||||||||||||||||||||||||||||||
|
Size of memory space for the entity.
This node is used to replace h3cEntityExtMemSize. |
bytesHCNUM-TCCounterBasedGauge64 | .1.3.6.1.4.1.2011.10.2.6.1.1.1.1.32 |
||||||||||||||||||||||||||||||||||
|
The CPU usage in last one minute for this entity.
Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity. |
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.33 |
||||||||||||||||||||||||||||||||||
|
The CPU usage in last five minutes for this entity.
Generally, the overall CPU usage on the entity is calculated, independent of the number of CPUs on the entity. |
Integer32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.1.1.1.34 |
h3cEntityExtManuTable
table.1.3.6.1.4.1.2011.10.2.6.1.2.1
·
1 row entry
·
5 columns
Uses the h3c variant from
Command help
/opt/observium/mibs/h3c.
Walk h3cEntityExtManuTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'H3C-ENTITY-EXT-MIB' -M '/opt/observium/mibs/h3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'H3C-ENTITY-EXT-MIB::h3cEntityExtManuTable'
The table about device manufacture information.
The device manufacture information about a particular physical
entity.
entity.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The index of h3cEntityExtManuTable.
This index is identical to entPhysicalIndex in ENTITY-MIB. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.2.1.1.1 |
|
Manufacture serial number.
The manufacture serial number of the entity such as chassis, module, and so on. It is got from the device when manufacturing. For low level box-device, the manufacture serial number is the de… |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.2011.10.2.6.1.2.1.1.2 |
|
Device version information.
The device version information of the entity such as chassis, module, and so on. It consists of software version information and hardware version information. |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.2011.10.2.6.1.2.1.1.3 |
|
Device BOM code.
The device BOM code of the entity such as chassis, module, and so on. It is the component code of ERP system, which can be disassembled from device-number. |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.2011.10.2.6.1.2.1.1.4 |
|
MAC address count.
The count of MAC addresses of the entity, such as chassis, module, or port, and so on. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2011.10.2.6.1.2.1.1.5 |
h3cEntityExtPowerTable
table.1.3.6.1.4.1.2011.10.2.6.1.3.1
·
1 row entry
·
5 columns
Uses the h3c variant from
Command help
/opt/observium/mibs/h3c.
Walk h3cEntityExtPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'H3C-ENTITY-EXT-MIB' -M '/opt/observium/mibs/h3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'H3C-ENTITY-EXT-MIB::h3cEntityExtPowerTable'
This table describes the power information of all the physical entity on the device, such as the fans, the subcards, the boards, etc.
The entity power information about a particular physical entity.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
The index of h3cEntityExtPowerTable.
This index is identical to entPhysicalIndex in ENTITY-MIB. |
Integer32 Constraints: range: 1-2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.3.1.1.1 |
|
The nominal power of the entity expressed in milliWatts.
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2011.10.2.6.1.3.1.1.2 |
|
The measured usage power of the entity expressed in milliWatts.
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2011.10.2.6.1.3.1.1.3 |
|
The average power consumed by the entity expressed in milliWatts.
Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is return… |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.3.1.1.4 |
|
The peak power consumed by the entity expressed in milliWatts.
Writing a value of zero to this object resets its value to zero. Writing any other value to this object has no effect on its value and an error is returned. |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.3.1.1.5 |
h3cProcessTable
table.1.3.6.1.4.1.2011.10.2.6.1.4.1
·
1 row entry
·
3 columns
Uses the h3c variant from
Command help
/opt/observium/mibs/h3c.
Walk h3cProcessTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'H3C-ENTITY-EXT-MIB' -M '/opt/observium/mibs/h3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'H3C-ENTITY-EXT-MIB::h3cProcessTable'
The Table describes the information about a particular process, namely a task.
The information about a particular process, namely a task.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
This object indicates the identifier of process, namely task ID
in system. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.2011.10.2.6.1.4.1.1.1 |
|
This object indicates the process name.
|
OctetString Constraints: range: 1-32 |
.1.3.6.1.4.1.2011.10.2.6.1.4.1.1.2 |
|
This object provides a general idea of how busy a process caused
the processor to be over a 5 minute period. The ratio is calculated by the overall CPU usage caused by the process. |
Unsigned32 Constraints: range: 0-100 |
.1.3.6.1.4.1.2011.10.2.6.1.4.1.1.3 |
h3cEntityExtVoltageTable
table.1.3.6.1.4.1.2011.10.2.6.1.5.1
·
1 row entry
·
7 columns
Uses the h3c variant from
Command help
/opt/observium/mibs/h3c.
Walk h3cEntityExtVoltageTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'H3C-ENTITY-EXT-MIB' -M '/opt/observium/mibs/h3c:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'H3C-ENTITY-EXT-MIB::h3cEntityExtVoltageTable'
The table describes the voltage information of the voltage sensor entities on the device.
The voltage information of the voltage sensor entity.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The current voltage in millivolts of the voltage
sensor entity. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.1 |
||||||||||
|
The nominal voltage in millivolts of the voltage
sensor entity. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.2 |
||||||||||
|
The voltage state of the voltage sensor entity.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.3 |
||||||||||
|
The low threshold for the voltage sensor entity.
When the voltage is lower than the threshold, a notification will be sent. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.4 |
||||||||||
|
The fatal low voltage threshold for the voltage sensor entity.
When the voltage is lower than the threshold, a notification will be sent. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.5 |
||||||||||
|
The high threshold for the voltage sensor entity.
When the voltage is higher than the threshold, a notification will be sent. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.6 |
||||||||||
|
The fatal high threshold for the voltage sensor entity.
When the voltage is higher than the threshold, a notification will be sent. |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.2011.10.2.6.1.5.1.1.7 |