GUDEADS-PDU818X-MIB
Monitored by Observium
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Counters
Sensors
Explore Observium network monitoring
- Source file
GUDEADS-PDU818X-MIB- Last revised
- Identity
gudeads- Base OID
1.3.6.1.4.1.28507
Imported Objects
| SNMPv2-CONF | NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | enterprises Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) Unsigned32 |
Net-SNMP examples using the gude MIB directory Show commands
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'GUDEADS-PDU818X-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'GUDEADS-PDU818X-MIB::gudeads'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUDEADS-PDU818X-MIB' -M '/opt/observium/mibs/gude:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUDEADS-PDU818X-MIB::gudeads'
Objects (34)
6 directly used by Observium
Showing 34 of 34 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
| gudeads | .1.3.6.1.4.1.28507 | |
.1.3.6.1.4.1.28507.35 | ||
.1.3.6.1.4.1.28507.35.0 | ||
.1.3.6.1.4.1.28507.35.1 | ||
.1.3.6.1.4.1.28507.35.1.1 | ||
.1.3.6.1.4.1.28507.35.1.1.1 | ||
| Integer32 | .1.3.6.1.4.1.28507.35.1.1.1.1 | |
| pdu818XTrapIPTable | .1.3.6.1.4.1.28507.35.1.1.1.2 | |
| pdu818XTrapIPEntry | .1.3.6.1.4.1.28507.35.1.1.1.2.1 | |
| pdu818XTrapIPIndex | Integer32 | .1.3.6.1.4.1.28507.35.1.1.1.2.1.1 |
| OctetString | .1.3.6.1.4.1.28507.35.1.1.1.2.1.2 | |
.1.3.6.1.4.1.28507.35.1.2 | ||
.1.3.6.1.4.1.28507.35.1.3 | ||
.1.3.6.1.4.1.28507.35.1.4 | ||
.1.3.6.1.4.1.28507.35.1.5 | ||
.1.3.6.1.4.1.28507.35.1.5.1 | ||
| pdu818XActivePowerChan | Unsigned32 | .1.3.6.1.4.1.28507.35.1.5.1.1 |
| pdu818XPowerTable | .1.3.6.1.4.1.28507.35.1.5.1.2 | |
| pdu818XPowerEntry | .1.3.6.1.4.1.28507.35.1.5.1.2.1 | |
| pdu818XPowerIndex | Integer32 | .1.3.6.1.4.1.28507.35.1.5.1.2.1.1 |
| pdu818XChanStatus | Integer32 | .1.3.6.1.4.1.28507.35.1.5.1.2.1.2 |
| pdu818XEnergyActiveOBS ✓ | WhSNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.28507.35.1.5.1.2.1.3 |
| pdu818XPowerActiveOBS ✓ | WSNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.28507.35.1.5.1.2.1.4 |
| pdu818XCurrentOBS ✓ | mASNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.28507.35.1.5.1.2.1.5 |
| pdu818XVoltageOBS ✓ | VSNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.28507.35.1.5.1.2.1.6 |
.1.3.6.1.4.1.28507.35.1.6 | ||
| pdu818XSensorTable | .1.3.6.1.4.1.28507.35.1.6.1 | |
| pdu818XSensorEntry | .1.3.6.1.4.1.28507.35.1.6.1.1 | |
| pdu818XSensorIndex | Integer32 | .1.3.6.1.4.1.28507.35.1.6.1.1.1 |
| pdu818XTempSensorOBS ✓ | 10th of degree CelsiusSNMPv2-SMIInteger32 | .1.3.6.1.4.1.28507.35.1.6.1.1.2 |
| pdu818XHygroSensorOBS ✓ | 10th of percentage humiditySNMPv2-SMIInteger32 | .1.3.6.1.4.1.28507.35.1.6.1.1.3 |
.1.3.6.1.4.1.28507.35.2 | ||
.1.3.6.1.4.1.28507.35.2.1 | ||
.1.3.6.1.4.1.28507.35.2.2 |
Dependencies (2) 2 direct Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-CONFrfc
- GUDEADS-PDU818X-MIBgudeselected
Conformance Groups (2)
|
pdu818XTrapCtrl pdu818XTrapAddr pdu818XTempSensor pdu818XHygroSensor pdu818XActivePowerChan pdu818XChanStatus pdu818XEnergyActive pdu818XPowerActive pdu818XCurrent pdu818XVoltage
Basic objects.
|
.1.3.6.1.4.1.28507.35.2.1.1
|
|
.1.3.6.1.4.1.28507.35.2.1.2
|
Notifications / Traps (6)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.28507.35.0.1 |
Event is triggered when a data
for a Power Channel is incoming |
|
.1.3.6.1.4.1.28507.35.0.2 |
Event is triggered when a data
for a Power Channel is incoming |
|
.1.3.6.1.4.1.28507.35.0.3 |
Event is triggered when a data
for a Power Channel is incoming |
|
.1.3.6.1.4.1.28507.35.0.4 |
Event is triggered when a data
for a Power Channel is incoming |
|
.1.3.6.1.4.1.28507.35.0.6 |
temperature limits exceeded
|
|
.1.3.6.1.4.1.28507.35.0.7 |
hygro limits exceeded
|