GUD-CCDCDWC-MIB
Monitored by ObserviumGuntermann & Drunck Systementwicklung MIB
Observium actively monitors this MIB
Visit Observium
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors
Status
- Source file
GUD-CCDCDWC-MIB- Last revised
- Identity
gudCCDCDWCMIB- Base OID
1.3.6.1.4.1.32828.3.257.16.1.3.1- Objects
- 0 scalars · 30 columns
- Tables
- 4 tables
Net-SNMP examples using the gdsys MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'GUD-CCDCDWC-MIB' -M '/opt/observium/mibs/gdsys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'GUD-CCDCDWC-MIB::gudCCDCDWCMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'GUD-CCDCDWC-MIB' -M '/opt/observium/mibs/gdsys:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'GUD-CCDCDWC-MIB::gudCCDCDWCMIB'
Imported Objects
| GUD-CCDC-MIB | gudCCDCDWC |
| SNMPv2-CONF | MODULE-COMPLIANCE (no object page) OBJECT-GROUP (no object page) |
| SNMPv2-SMI | Integer32 MODULE-IDENTITY (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page) |
| SNMPv2-TC | DisplayString TEXTUAL-CONVENTION (no object page) |
Objects
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000
· 11 columns
Table of monitored devices.
dynamicUserModuleEntry
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1
Index
dynamicUserModuleIndex
| Column | Syntax | OID |
|---|---|---|
| dynamicUserModuleIndex | Integer32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.1 |
| id | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.2 |
| cl | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.3 |
| nameOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.4 |
| deviceStatusOBS ✓ | DeviceStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.5 |
| mainPowerOBS ✓ | PowerStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.6 |
| redundantPowerOBS ✓ | PowerStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.7 |
| temperature1OBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.8 |
| consoleUSBConnectionOBS ✓ | KeyboardMouseStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.9 |
| networkInterface0OBS ✓ | NetworkInterfaceStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.10 |
| networkInterface1OBS ✓ | NetworkInterfaceStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1000.1.11 |
Fan status table.
fanTableEntry
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1001.1
| Column | Syntax | OID |
|---|---|---|
| fanIndex | Integer32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1001.1.1 |
| fanName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1001.1.2 |
| fanSpeed | Integer32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1001.1.3 |
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1002
· 3 columns
Video channel status table.
videoChannelEntry
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1002.1
| Column | Syntax | OID |
|---|---|---|
| videoChannelIndex | Integer32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1002.1.1 |
| displayConnection | ConnectionStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1002.1.2 |
| displayType | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1002.1.3 |
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003
· 13 columns
Link status table.
linkChannelEntry
.1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1
| Column | Syntax | OID |
|---|---|---|
| linkChannelIndex | Integer32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.1 |
| conid | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.2 |
| concl | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.3 |
| conname | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.4 |
| linkChannelStatus | DeviceStatus | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.5 |
| activeTransmissionPort | Integer32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.6 |
| sfpTxPower1 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.7 |
| sfpTxPower2 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.8 |
| sfpRxPower1 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.9 |
| sfpRxPower2 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.10 |
| sfpType1 | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.11 |
| sfpType2 | SNMPv2-TCDisplayString | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.12 |
| freeze | Boolean | .1.3.6.1.4.1.32828.3.257.16.1.3.2.3.1003.1.13 |
Type Definitions (6)
| Type | Syntax | Constraints |
|---|---|---|
| Boolean | Enumeration | 2 values |
| ConnectionStatus | Enumeration | 2 values |
| DeviceStatus | Enumeration | 3 values |
| KeyboardMouseStatus | Enumeration | 4 values |
| NetworkInterfaceStatus | Enumeration | 2 values |
| PowerStatus | Enumeration | 2 values |
Conformance Groups (1)
statusGroup .1.3.6.1.4.1.32828.3.257.16.1.3.3.2.3
Members (26)
Compliance Statements (1)
gudCCDCDWCMIBCompliance .1.3.6.1.4.1.32828.3.257.16.1.3.3.1.1
Dependencies (5) 4 direct · 1 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- GUD-SMI-MIBgdsys
- SNMPv2-CONFrfc
- SNMPv2-TCrfc
- GUD-CCDC-MIBgdsys
- GUD-CCDCDWC-MIBgdsysselected