G6-POE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
20
configTable
table.1.3.6.1.4.1.3181.10.6.1.33.3
·
1 row entry
·
4 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk configTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-POE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-POE-MIB::configTable'
Power over Ethernet function permits the powering of connected units which do not use their own local power supply.
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-24 |
.1.3.6.1.4.1.3181.10.6.1.33.3.1.1 |
||||||||||||||||
|
Used to enable or disable PoE function.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.33.3.1.2 |
||||||||||||||||
|
Ports without priority may be switched off under a power contention situation.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.33.3.1.3 |
||||||||||||||||
|
Allow between 15-30W power consumption.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.33.3.1.4 |
statusTable
table.1.3.6.1.4.1.3181.10.6.1.33.101
·
1 row entry
·
9 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk statusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-POE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-POE-MIB::statusTable'
This table list the current PoE port conditions.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-31 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.1 |
||||||||||||||||||||
|
PoE status and conditions.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.33.101.1.2 |
||||||||||||||||||||
|
Determined and negotiated PoE class.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.3181.10.6.1.33.101.1.3 |
||||||||||||||||||||
|
Current delivered to the attached device. (units: mA)
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.4 |
||||||||||||||||||||
|
Voltage deliverd to the attached device. (units: mV)
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.5 |
||||||||||||||||||||
|
Calculated power delivered to the attached device. (units: mW)
|
Integer32 Constraints: range: 0-65535 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.6 |
||||||||||||||||||||
|
Incremented whenever a PoE request was denied regardless of reason.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.7 |
||||||||||||||||||||
|
Incremented whenever an over_current condition was detected.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.8 |
||||||||||||||||||||
|
Incremented whenever a short circuit was detected.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.101.1.9 |
energySuppliedTable
table.1.3.6.1.4.1.3181.10.6.1.33.102
·
1 row entry
·
7 columns
Uses the microsens variant from
Command help
/opt/observium/mibs/microsens.
Walk energySuppliedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'G6-POE-MIB' -M '/opt/observium/mibs/microsens:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G6-POE-MIB::energySuppliedTable'
This table list the power provided via PoE ports. The values are automatically updated in the given interval.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
Automatically generated
|
Integer32 Constraints: range: 0-31 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.1 |
|
Energy supplied in the past 5 seconds. Value in joule.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.2 |
|
Energy supplied in the past 15 seconds. Value in joule.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.3 |
|
Energy supplied in the past 60 seconds. Value in joule.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.4 |
|
Energy supplied in the past 15 minutes. Value in joule.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.5 |
|
Energy supplied in the past hour. Value in joule.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.6 |
|
Energy supplied in the past day. Value in joule.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.3181.10.6.1.33.102.1.7 |