G3-AVAYA-TRAP
- Source file
G3-AVAYA-TRAP- Last revised
- Not declared
Imported Objects
Objects (0)
Dependencies (8) 3 direct · 5 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- RFC1155-SMIrfc
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- RFC-1212rfc
- RFC1213-MIBrfc
- G3-AVAYA-MIBavaya
- RFC-1215rfc
- G3-AVAYA-TRAPavayaselected
Notifications / Traps (25)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.6889.1.8.1.0.0 |
A Cleared Alarm Notification has been issued by
the switch indicating that all alarms have been cleared. |
|
.1.3.6.1.4.1.6889.1.8.1.0.1 |
This trap is defined for future use.
|
|
.1.3.6.1.4.1.6889.1.8.1.0.10 |
A NAK was received in an attempt to forward the
alarm to INADS. |
|
.1.3.6.1.4.1.6889.1.8.1.0.101 |
The connection status of the PBX/ECS has changed
to OTHER. This status indicates that the connect is in an unknown state. |
|
.1.3.6.1.4.1.6889.1.8.1.0.102 |
The connection status of the PBX/ECS has changed
to OFF. This status indicates that user set the connection state to off so that the Proxy Agent will not start up a connection with the PBX/ECS. |
|
.1.3.6.1.4.1.6889.1.8.1.0.103 |
The connection status of the PBX/ECS has changed
to DOWN. This status indicates that the Proxy Agent attempted to establish a connection with the PBX/ECS and failed. |
|
.1.3.6.1.4.1.6889.1.8.1.0.104 |
The connection status of the PBX/ECS has changed
to INIT. This status indicates that the Proxy Agent is in the process of attempting to connect to the PBX/ECS. |
|
.1.3.6.1.4.1.6889.1.8.1.0.105 |
The connection status of the PBX/ECS has changed
to UP. This status indicates that the Proxy Agent has a connection established with the PBX/ECS. |
|
.1.3.6.1.4.1.6889.1.8.1.0.106 |
The connection status of the PBX/ECS has changed
to IDLE. This status indicates that a connection with the PBX/ECS is currently inactive due to the dynamic timeout having been reached without any activity. The connection will stay in the IDLE state until an SNMP request or alarm is received. This connection status only applies if the connection type is 'dynamic'. |
|
.1.3.6.1.4.1.6889.1.8.1.0.11 |
A response other than an ACK or NAK was received
in an attempt to forward the alarm to INADS. |
|
.1.3.6.1.4.1.6889.1.8.1.0.110 |
The connection to a PBX/ECS could not be established
due to the maximum allowed number of simultaneous connections already being active. |
|
.1.3.6.1.4.1.6889.1.8.1.0.12 |
An alarm has been resolved on the switch.
The fields in this trap type has the same differences, for g3alarmsPort, g3alarmsMaintName, and g3alarmsOnBrd, as described above for the alarmMajor trap type. |
|
|
G3-AVAYA-MIBg3clientExternalName G3-AVAYA-MIBg3alarmsProductID G3-AVAYA-MIBg3alarmsAlarmNumber G3-AVAYA-MIBg3alarmsPort G3-AVAYA-MIBg3alarmsAlarmType G3-AVAYA-MIBg3alarmsCategory G3-AVAYA-MIBg3alarmsSrcIPAddr G3-AVAYA-MIBg3alarmsSrcMACAddr G3-AVAYA-MIBg3alarmsDestIPAddr G3-AVAYA-MIBg3alarmsDestPort G3-AVAYA-MIBg3alarmsProtocol G3-AVAYA-MIBg3alarmsCount G3-AVAYA-MIBg3alarmsViolationType G3-AVAYA-MIBg3alarmsCode G3-AVAYA-MIBg3alarmsData G3-AVAYA-MIBg3alarmsICMPType G3-AVAYA-MIBg3alarmsEventID G3-AVAYA-MIBg3alarmsStatus
|
.1.3.6.1.4.1.6889.1.8.1.0.13 |
An alarm associated with security related events
has been issued by the server. |
|
G3-AVAYA-MIBg3clientExternalName G3-AVAYA-MIBg3alarmsProductID G3-AVAYA-MIBg3alarmsAlarmNumber G3-AVAYA-MIBg3alarmsPort G3-AVAYA-MIBg3alarmsMaintName G3-AVAYA-MIBg3alarmsOnBrd G3-AVAYA-MIBg3alarmsAlarmType G3-AVAYA-MIBg3extdevAltName G3-AVAYA-MIBg3extdevDescription G3-AVAYA-MIBg3extdevID G3-AVAYA-MIBg3extdevBuilding G3-AVAYA-MIBg3extdevAddress G3-AVAYA-MIBg3alarmsIPAddress G3-AVAYA-MIBg3alarmsCategory G3-AVAYA-MIBg3alarmsErrorCodes
|
.1.3.6.1.4.1.6889.1.8.1.0.14 |
An external device Warning alarm has been issued
by the switch. The variables describe the location and nature of the alarm. This trap type only applies to voice server alarms. |
|
G3-AVAYA-MIBg3clientExternalName G3-AVAYA-MIBg3alarmsProductID G3-AVAYA-MIBg3alarmsAlarmNumber G3-AVAYA-MIBg3alarmsPort G3-AVAYA-MIBg3alarmsMaintName G3-AVAYA-MIBg3alarmsOnBrd G3-AVAYA-MIBg3alarmsAlarmType G3-AVAYA-MIBg3extdevAltName G3-AVAYA-MIBg3extdevDescription G3-AVAYA-MIBg3extdevID G3-AVAYA-MIBg3extdevBuilding G3-AVAYA-MIBg3extdevAddress G3-AVAYA-MIBg3alarmsIPAddress G3-AVAYA-MIBg3alarmsCategory G3-AVAYA-MIBg3alarmsErrorCodes
|
.1.3.6.1.4.1.6889.1.8.1.0.15 |
An external device alarm has been resolved
by the switch. The variables describe the location and nature of the alarm. This trap type only applies to voice server alarms. |
.1.3.6.1.4.1.6889.1.8.1.0.150 |
The user has issued a stop proxy-agent command to
bring down the Proxy Agent. |
|
.1.3.6.1.4.1.6889.1.8.1.0.151 |
The user has issued a start proxy-agent command to
bring up the Proxy Agent. |
|
.1.3.6.1.4.1.6889.1.8.1.0.2 |
A Major alarm has been issued by the switch. The
MIB variables provide attributes of the alarm. The information contained in the g3alarmsPort, g3alarmsMaintName, g3alarmsOnBrd trap variables differ depending on the kind of alarm. If the alarm is a voice server alarm these fields contain, respectively, an equipment location, maintenance object name, and flag indicating whether or not the alarm was on-board. For server platform alarms and messaging alarms these fields contain, respectively, an alarm description including the source of the alarm, a string indicating the resource from which the alarm was generated, and an event ID associated with that resource. More details on the contents of these fields can be found in the appropriate product maintenance documentation. |
|
.1.3.6.1.4.1.6889.1.8.1.0.3 |
A Minor alarm has been issued by the switch.
The fields in this trap type has the same differences, for g3alarmsPort, g3alarmsMaintName, and g3alarmsOnBrd, as described above for the alarmMajor trap type. |
|
.1.3.6.1.4.1.6889.1.8.1.0.4 |
A Warning alarm has been issued by the switch.
The fields in this trap type has the same differences, for g3alarmsPort, g3alarmsMaintName, and g3alarmsOnBrd, as described above for the alarmMajor trap type. |
|
|
G3-AVAYA-MIBg3clientExternalName G3-AVAYA-MIBg3alarmsProductID G3-AVAYA-MIBg3alarmsAlarmNumber G3-AVAYA-MIBg3alarmsPort G3-AVAYA-MIBg3alarmsMaintName G3-AVAYA-MIBg3alarmsOnBrd G3-AVAYA-MIBg3alarmsAlarmType G3-AVAYA-MIBg3extdevAltName G3-AVAYA-MIBg3extdevDescription G3-AVAYA-MIBg3extdevID G3-AVAYA-MIBg3extdevBuilding G3-AVAYA-MIBg3extdevAddress G3-AVAYA-MIBg3alarmsIPAddress G3-AVAYA-MIBg3alarmsCategory G3-AVAYA-MIBg3alarmsErrorCodes
|
.1.3.6.1.4.1.6889.1.8.1.0.5 |
An external device Major alarm has been issued
by the switch. The variables describe the location and nature of the alarm. This trap type only applies to voice server alarms. |
|
G3-AVAYA-MIBg3clientExternalName G3-AVAYA-MIBg3alarmsProductID G3-AVAYA-MIBg3alarmsAlarmNumber G3-AVAYA-MIBg3alarmsPort G3-AVAYA-MIBg3alarmsMaintName G3-AVAYA-MIBg3alarmsOnBrd G3-AVAYA-MIBg3alarmsAlarmType G3-AVAYA-MIBg3extdevAltName G3-AVAYA-MIBg3extdevDescription G3-AVAYA-MIBg3extdevID G3-AVAYA-MIBg3extdevBuilding G3-AVAYA-MIBg3extdevAddress G3-AVAYA-MIBg3alarmsIPAddress G3-AVAYA-MIBg3alarmsCategory G3-AVAYA-MIBg3alarmsErrorCodes
|
.1.3.6.1.4.1.6889.1.8.1.0.6 |
An external device Minor alarm has been issued
by the switch. The variables describe the location and nature of the alarm. This trap type only applies to voice server alarms. |
.1.3.6.1.4.1.6889.1.8.1.0.7 |
INADS has dispatched the alarm.
|
|
.1.3.6.1.4.1.6889.1.8.1.0.8 |
INADS has closed the alarm.
|
|
|
G3-AVAYA-MIBg3clientExternalName G3-AVAYA-MIBg3alarmsProductID G3-AVAYA-MIBg3alarmsAlarmNumber G3-AVAYA-MIBg3restartDateTime G3-AVAYA-MIBg3restartLevel G3-AVAYA-MIBg3restartCarrier G3-AVAYA-MIBg3restartCraftDemand G3-AVAYA-MIBg3restartEscalated G3-AVAYA-MIBg3restartInterchange G3-AVAYA-MIBg3restartUnavailable G3-AVAYA-MIBg3restartCause G3-AVAYA-MIBg3vintageSpeArelease G3-AVAYA-MIBg3vintageSpeBrelease G3-AVAYA-MIBg3vintageSpeAupID G3-AVAYA-MIBg3vintageSpeBupID
|
.1.3.6.1.4.1.6889.1.8.1.0.9 |
A system restart has occurred on the switch.
The variables describe the location and nature of the restart. |