FDRY-POE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
24
snAgentPoePortTable
table.1.3.6.1.4.1.1991.1.1.2.14.2.2
·
1 row entry
·
16 columns
Uses the brocade variant from
Command help
/opt/observium/mibs/brocade.
Walk snAgentPoePortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FDRY-POE-MIB' -M '/opt/observium/mibs/brocade:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FDRY-POE-MIB::snAgentPoePortTable'
A table of POE port information.
A row in the POE port table.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The port number in ifIndex value.
|
IF-MIBInterfaceIndex Type Constraints: range: 1..2147483647Description: A unique value, greater than zero, for each interface or interface sub-layer in the managed system. It is recommended that values are assigned contiguously starting from 1. The value for each interface sub-layer must … |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.1 |
||||||||||||
|
Control inline power on/off to a port. If a port does not
have inline power capability, reading this object returns 'other(1)'. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.2 |
||||||||||||
|
Adjust the inline power wattage. Valid value between 1000
to 15400(IEEE802_3AF)/30000(IEEE802_3AT)/120000(IEEE802_3BT). Each unit is milliwatts. This object can only be set after snSwIfInLinePowerControl has been set to… |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.3 |
||||||||||||
|
Adjust the inline power class. Valid value between 0 to 3(IEEE802_3AF)/4(IEEE802_3AT).
This object can only be set after snSwIfInLinePowerControl has been set to 'enable(3)' or 'enableLegacyDevice(4)'. If a port does no… |
SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.4 |
||||||||||||
|
Inline power allocation priority for the power device
0- Not a POE port, 1- Critical, 2- High, 3- Low, 4- Medium, 5- other. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.5 |
||||||||||||
|
Inline power consumed by the port. Each unit is milliwatts.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.6 |
||||||||||||
|
Inline Power device type 802.3af, 802.3at, 802.3bt or Legacy device.
|
SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.7 |
||||||||||||
|
This is a PD signature which the decive learns in the process of
PD-classification. PD detection and PD-classification are two steps of powering PD. And if PD is powered without user power Spec, then PoE port power li… |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.8 |
||||||||||||
|
This is second PD class signature of dual signature PD which the device learns in the process of
PD-classification. PD detection and PD-classification are two steps of powering PD. And if PD is powered without user po… |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.9 |
||||||||||||
|
Maximum power requested by PD through LLDP in milliwatts.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.10 |
||||||||||||
|
snAgentPoePortlldpReqPwrAdeprecated
Maximum power requested by PD through LLDP in milliwatts. In case of Dual Signature PD we have 2 channel
snAgentPoePortlldpReqPwrA is power in milliwatts for channel A. This is deprecated as the required information is … |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.11 |
||||||||||||
|
snAgentPoePortlldpReqPwrBdeprecated
Maximum power requested by PD through LLDP in milliwatts. In case of Dual Signature PD we have 2 channel
snAgentPoePortlldpReqPwrB is power in milliwatts for channel B. This is deprecated as the required information is … |
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.12 |
||||||||||||
|
Capability of port, 0-others, 1-2pair, 2-4pair.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.13 |
||||||||||||
|
Maximum power supported by 2pair port in milliwatts.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.14 |
||||||||||||
|
Maximum power supported by 4pair port in milliwatts.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.15 |
||||||||||||
|
Poe port overdrive mode.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1991.1.1.2.14.2.2.1.16 |
snAgentPoeModuleTable
table.1.3.6.1.4.1.1991.1.1.2.14.3.1
·
1 row entry
·
3 columns
Uses the brocade variant from
Command help
/opt/observium/mibs/brocade.
Walk snAgentPoeModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FDRY-POE-MIB' -M '/opt/observium/mibs/brocade:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FDRY-POE-MIB::snAgentPoeModuleTable'
A table of POE Module configuration.
A row in the POE Module table.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
This objects talks about POE module number.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1991.1.1.2.14.3.1.1.1 |
||||
|
This objects talks about module power budget in watts.
|
SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1991.1.1.2.14.3.1.1.2 |
||||
|
This object talks about the POE module type which is capable to support Power Device (PD) type
ieee802.3af or ieee802.3at(also called POE plus)type. Module which support ieee802.3at can also support ieee802.3af but rev… |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1991.1.1.2.14.3.1.1.3 |
snAgentPoeUnitTable
table.1.3.6.1.4.1.1991.1.1.2.14.4.1
·
1 row entry
·
5 columns
Uses the brocade variant from
Command help
/opt/observium/mibs/brocade.
Walk snAgentPoeUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FDRY-POE-MIB' -M '/opt/observium/mibs/brocade:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FDRY-POE-MIB::snAgentPoeUnitTable'
A table of POE informaion for each unit. Only the unit that has POE capability appears in a table row
A row in the POE Unit table.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
The Index to POE unit Table.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1991.1.1.2.14.4.1.1.1 |
||||||
|
This object shows the total inline power capacity available on that unit (device), measured in mWatts.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1991.1.1.2.14.4.1.1.2 |
||||||
|
This object shows the inline power capacity currently available on that unit (device) which is unallocated, measured in mWatts.
In case of Static allocation total free power and in case of Dynamic allocation total uncon… |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1991.1.1.2.14.4.1.1.3 |
||||||
|
This object shows number of times the inline power allocations requests honored on that unit (device).
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.1991.1.1.2.14.4.1.1.4 |
||||||
|
This object shows the power allocation type, based on which the total free capacity is displayed. Static(1) or Dynamic(2) power allocation.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.1991.1.1.2.14.4.1.1.5 |