F10-Z-SERIES-CHASSIS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
8
Rows
8
Columns
51
chSysProcessorTable
table.1.3.6.1.4.1.6027.3.25.1.2.1
·
1 row entry
·
4 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysProcessorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysProcessorTable'
A list of Processors resident in the chassis. The card table contains the Processor information of each Processor in the chassis.
A list of Processor's entries containing information
for Processors in the system.
for Processors in the system.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chSysProcessorIndexA unique index for each Processor within the chassis. The valid entries are 1 to the value of number of processors. In Z9500, Index 1 - Control Processor Index 2 - Routing Processor Index 3 - LineCar… | Integer32 Constraints: range: 1-5 | .1.3.6.1.4.1.6027.3.25.1.2.1.1.1 | ||||||||||||
| chSysProcessorTypeThe type of module running on the Processor. | FORCE10-TCF10ProcessorModuleType Type Values:
| .1.3.6.1.4.1.6027.3.25.1.2.1.1.2 | ||||||||||||
| chSysProcessorUpTimeThe SysUpTime for this Processor. | SNMPv2-SMITimeTicks Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.25.1.2.1.1.3 | ||||||||||||
| chSysProcessorMemSizeThe size of the RAM in MB. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.1.1.4 |
chSysSwModuleTable
table.1.3.6.1.4.1.6027.3.25.1.2.2
·
1 row entry
·
8 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysSwModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysSwModuleTable'
A list of software version information in a processor.
A software module entry containing version
number information for a particular processor.
number information for a particular processor.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| chSysSwModuleRuntimeImgVersionCurrent FTOS image version running in the system. The version string will be in following format major_ver.minor_ver(maintenance_ver.patch_ver) | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.6027.3.25.1.2.2.1.1 | ||||||
| chSysSwModuleRuntimeImgDateThe release date of this software module. | OctetString Constraints: range: 0-10 | .1.3.6.1.4.1.6027.3.25.1.2.2.1.2 | ||||||
| chSysSwModuleBootFlashImgVersionThis provides the Grub image version that is currently running in the processor. | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.6027.3.25.1.2.2.1.3 | ||||||
| chSysSwModuleBootSelectorImgVersionThis provides the BIOS image version that is currently running in the processor. | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.6027.3.25.1.2.2.1.4 | ||||||
| chSysSwModuleNextRebootImageThe image selection, when the chassis is rebooted. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - will be booted via network. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.2.1.5 | ||||||
| chSysSwModuleCurrentBootImageThe current image is booted from. partitionA - Image stored in bootflash partition A: partitionB - Image stored in bootflash partition B: networkBoot - Booted via network. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.2.1.6 | ||||||
| chSysSwModuleInPartitionAImgVersThis provides the FTOS system image version that is stored in partition A: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or General… | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.6027.3.25.1.2.2.1.7 | ||||||
| chSysSwModuleInPartitionBImgVersThis provides the FTOS system image version that is stored in partition B: and The version string has Major and Minor release numbers. It also denotes if the release is Maintenance, Technical, Patch, Beta, or Generally… | OctetString Constraints: range: 0-16 | .1.3.6.1.4.1.6027.3.25.1.2.2.1.8 |
chSysCpuUtilTable
table.1.3.6.1.4.1.6027.3.25.1.2.3
·
1 row entry
·
5 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysCpuUtilTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysCpuUtilTable'
A table listing the processor and memory utilization of of each CPU in the system.
Processor and Memory Utilization entry for a
particular CPU.
particular CPU.
Indexes
| Column | Syntax | OID |
|---|---|---|
| chSysCpuUtil5SecCPU utilization in percentage for last 5 seconds. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.25.1.2.3.1.1 |
| chSysCpuUtil1MinCPU utilization in percentage for last 1 minute. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.25.1.2.3.1.2 |
| chSysCpuUtil5MinCPU utilization in percentage for last 5 minutes. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.25.1.2.3.1.3 |
| chSysCpuUtilMemUsageTotal Memory usage in percentage. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.25.1.2.3.1.4 |
| chSysCpuUtilFlashUsageTotal Flash usage in percentage. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.25.1.2.3.1.5 |
chSysLineCardTable
table.1.3.6.1.4.1.6027.3.25.1.2.4
·
1 row entry
·
7 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysLineCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysLineCardTable'
A list of line cards resident in the chassis. This table contains the information on each linecard in the chassis.
Entry for each line card in the chassis.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chSysLineCardIndexA unique index for each line card in the chassis. | Integer32 Constraints: range: 1-3 | .1.3.6.1.4.1.6027.3.25.1.2.4.1.1 | ||||||||||||
| chSysLineCardTypeLine card's type. In Z9500, there is 36 40G port line card and 48 40G port line card. z9500LC36 - 36 (40G) port LC z9500LC48 - 48 (40G) port LC. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.4.1.2 | ||||||||||||
| chSysLineCardDescriptionA short description of the line card. | OctetString Constraints: range: 0-40 | .1.3.6.1.4.1.6027.3.25.1.2.4.1.3 | ||||||||||||
| chSysLineCardStatusThe current operational state of the line card. | FORCE10-TCF10CardOperStatus Type Values:
| .1.3.6.1.4.1.6027.3.25.1.2.4.1.4 | ||||||||||||
| chSysLineCardTempTemperature of the Line card. | degrees CentigradeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.4.1.5 | ||||||||||||
| chSysLineCardNum10GigEtherPortsThe number of 10G Ethernet/802.3 interfaces in the line card. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.4.1.6 | ||||||||||||
| chSysLineCardNum40GigEtherPortsThe number of 40G Ethernet/802.3 interfaces in the line card. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.4.1.7 |
chSysPortTable
table.1.3.6.1.4.1.6027.3.25.1.2.5
·
1 row entry
·
8 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysPortTable'
A list of ports in the Z-series chassis.
A port entry containing objects for a
particular port.
particular port.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chSysPortIndexA unique index for each port within the Line Card. Line card 0 will have index from 1 to 144 Line card 1 will have index from 1 to 192 Line card 2 will have index from 1 to 192. | Integer32 Constraints: range: 1-192 | .1.3.6.1.4.1.6027.3.25.1.2.5.1.1 | ||||||||||||||
| chSysPortTypeThe type of port in the unit. | FORCE10-TCF10SSeriesPortType Type Values:
| .1.3.6.1.4.1.6027.3.25.1.2.5.1.2 | ||||||||||||||
| chSysPortAdminStatusThe admin status of the port. The port admin status is Up if the user has configured it to be up otherwise, the admin status is Down. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.5.1.3 | ||||||||||||||
| chSysPortOperStatusThe operational status provides further condition of the port. If the chSysPortAdminStatus is 'up', the valid state is 'ready' - the card is present and ready and the chSysPortAdminStatus status is 'up… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.5.1.4 | ||||||||||||||
| chSysPortIfIndexThe index of ifIndex in the Interface Mib. This index can link to the ifEntry to get this interface/port information | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.5.1.5 | ||||||||||||||
| chSysPortXfpRxPowerThe power signal strength (dB) received for 1G/10G/40G Ethernet/802.3 interface. | dBFORCE10-TCF10HundredthdB | .1.3.6.1.4.1.6027.3.25.1.2.5.1.6 | ||||||||||||||
| chSysPortXfpRxTempThe temperature value received for the optics. | degrees CentigradeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.5.1.7 | ||||||||||||||
| chSysPortXfpTxPowerThe power signal strength (dB) Transmitted for 1G/10G/40G Ethernet/802.3 interface. | dBFORCE10-TCF10HundredthdB | .1.3.6.1.4.1.6027.3.25.1.2.5.1.8 |
chSysPowerSupplyTable
table.1.3.6.1.4.1.6027.3.25.1.2.6
·
1 row entry
·
8 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysPowerSupplyTable'
A list of power supply resident in the Z-series chassis.
A power supply entry containing objects for a
particular power supply.
particular power supply.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| chSysPowerSupplyIndexThe unique index of the power supply. | Integer32 Constraints: range: 1-4 | .1.3.6.1.4.1.6027.3.25.1.2.6.1.1 | ||||||
| chSysPowerSupplyOperStatusThe status of the power supply. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.6.1.2 | ||||||
| chSysPowerSupplyTypeThe type of the power supply. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.6.1.3 | ||||||
| chSysPowerSupplyPiecePartIDThe power supply's piece part id. | OctetString Constraints: range: 0-24 | .1.3.6.1.4.1.6027.3.25.1.2.6.1.4 | ||||||
| chSysPowerSupplyPPIDRevisionThe power supply's PPID revision. | OctetString Constraints: range: 0-3 | .1.3.6.1.4.1.6027.3.25.1.2.6.1.5 | ||||||
| chSysPowerSupplyServiceTagThe power supply's service tag. | OctetString Constraints: range: 0-7 | .1.3.6.1.4.1.6027.3.25.1.2.6.1.6 | ||||||
| chSysPowerSupplyExpressServiceCodeThe power supply's express service code. | OctetString Constraints: range: 0-14 | .1.3.6.1.4.1.6027.3.25.1.2.6.1.7 | ||||||
| chSysPowerSupplyUsagePower usage of this Power Supply in Watts. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.6.1.8 |
chSysFanTrayTable
table.1.3.6.1.4.1.6027.3.25.1.2.7
·
1 row entry
·
6 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysFanTrayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysFanTrayTable'
A list of fan tray resident in the Z-series chassis.
A fan entry containing objects for a
particular fan tray.
particular fan tray.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
| chSysFanTrayIndexThe unique index of the fan tray. | Integer32 Constraints: range: 1-5 | .1.3.6.1.4.1.6027.3.25.1.2.7.1.1 | ||||||
| chSysFanTrayOperStatusThe status of the fan tray. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.25.1.2.7.1.2 | ||||||
| chSysFanTrayPiecePartIDThe fan tray's piece part id. | OctetString Constraints: range: 0-24 | .1.3.6.1.4.1.6027.3.25.1.2.7.1.3 | ||||||
| chSysFanTrayPPIDRevisionThe fan tray's PPID revision. | OctetString Constraints: range: 0-3 | .1.3.6.1.4.1.6027.3.25.1.2.7.1.4 | ||||||
| chSysFanTrayServiceTagThe fan tray's service tag. | OctetString Constraints: range: 0-7 | .1.3.6.1.4.1.6027.3.25.1.2.7.1.5 | ||||||
| chSysFanTrayExpressServiceCodeThe fan tray's express service code. | OctetString Constraints: range: 0-14 | .1.3.6.1.4.1.6027.3.25.1.2.7.1.6 |
chSysSwCoresTable
table.1.3.6.1.4.1.6027.3.25.1.2.8
·
1 row entry
·
5 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysSwCoresTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-Z-SERIES-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-Z-SERIES-CHASSIS-MIB::chSysSwCoresTable'
A table containing information about the software cores that have been generated as a result of system failures.
A row in the software core table representing
information about a core that has been generated.
information about a core that has been generated.
| Column | Syntax | OID |
|---|---|---|
| chSysCoresInstanceThe instance of the core for the process which which generated the core since the same process may have generated multiple cores. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.25.1.2.8.1.1 |
| chSysCoresFileNameThe name of the core file including the core. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.25.1.2.8.1.2 |
| chSysCoresTimeCreatedThe time at which the core file was created. | FORCE10-TCF10SwDate | .1.3.6.1.4.1.6027.3.25.1.2.8.1.3 |
| chSysCoresProcessorNameThe processor which generated the core. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.25.1.2.8.1.4 |
| chSysCoresProcessThe name of the process which generated the core. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.25.1.2.8.1.5 |