F10-CHASSIS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
9
Rows
9
Columns
77
chSysPowerSupplyTable
table.1.3.6.1.4.1.6027.3.1.1.2.1
·
1 row entry
·
3 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysPowerSupplyTable'
A list of power supply resident in this chassis.
A power supply entry containing objects for a
particular power supply.
particular power supply.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| chSysPowerSupplyIndexThe unique index of the power supply. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.1.1.1 | ||||
| chSysPowerSupplyOperStatusThe status of the power supply. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.1.1.2 | ||||
| chSysPowerSupplyTypeThe type of the power supply. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.1.1.3 |
chSysFanTrayTable
table.1.3.6.1.4.1.6027.3.1.1.2.2
·
1 row entry
·
2 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysFanTrayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysFanTrayTable'
A list of fan tray resident in this chassis.
A fan entry containing objects for a
particular fan tray.
particular fan tray.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| chSysFanTrayIndexThe unique index of the fan tray. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.2.1.1 | ||||
| chSysFanTrayOperStatusThe status of the fan tray. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.2.1.2 |
chSysCardTable
table.1.3.6.1.4.1.6027.3.1.1.2.3
·
1 row entry
·
24 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysCardTable'
A list of cards resident in the chassis.
The placement of line cards and rpm cards
in the E1200 chassis are as follows :
( physical slot numbers )
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
( Dell Networking OS card number )
0 1 2 3 4 5 6 0 1 7 8 9 10 11 12 13
| | | |
------------- -------------------
| | | |
line card | | line card
| |
| + ----> RPM card
+-------> RPM card
The placement of line cards and rpm cards
in the E600 chassis are as follows :
( physical slot numbers )
1 2 3 4 5 6 7 8 9
( Dell Networking OS card number )
0 1 2 3 4 5 6 0 1
| |
-------------
| | |
line card | |
| |
| + ----> RPM card
+-------> RPM card
The placement of line cards and rpm cards
in the E300 chassis are as follows :
( physical slot numbers )
1 2 3 4 5 6 7 8
( Dell Networking OS card number )
0 1 0 1 2 3 4 5
| |
-----------
| | |
| | line card
| |
| + ----> RPM card
+-------> RPM card
A list of cards entries containing information
for line card or rpm card.
for line card or rpm card.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chSysCardSlotIndexA unique index for each slot within the chassis. This value is the physical slot number and the value is determined by the chassis slot location where the card is inserted. Valid entries are 1 to th… | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardTypeType of card in this slot. The type of cards are defined in F10SystemCardType. | FORCE10-TCF10SystemCardType Type Values:
| .1.3.6.1.4.1.6027.3.1.1.2.3.1.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardNumberThis is the card number assigned to the line cards and the RPM cards in the chassis. The line cards number are from 0 to 13 and the RPM are from 0 to 1. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardSerialNumberThe serial number of the card in this slot. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.3.1.4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardVendorIdThe vendor id that manufactured the card in this slot. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.3.1.5 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardMfgDateThe date the card is manufactured. | FORCE10-TCF10MfgDate | .1.3.6.1.4.1.6027.3.1.1.2.3.1.6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
chSysCardEcLeveldeprecated The EC Level of the card. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.7 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardUpperTempThe temperature of the card. If the temperature is too high, alarm chAlarmCardTemperatureHigh will be sent. | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardLowerTempThis temperature field is not used at the moment. | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.9 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardNumProcessorsThe number of Processors in the card. The number of processors are depended on the type of card plugged into the slot. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.10 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardNumPhyPortsThe number of physical ports in each card. The card can have one or more ports depending on the type of cards. If it is a logical card, the value set to zero. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.11 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardNumLgcPortsThe number of logical ports in each card. The card can have one or more ports depending on the type of cards. If it is a physical card, the value set to zero. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.12 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardUpTimeThe SysUpTime for this slot. This variable indicates the time since the card last reset. | SNMPv2-SMITimeTicks Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.13 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardAdminStatusThe admin status of the card. The valid status are as followed: 'up' - card present and ready. 'down' - card is not ready. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.3.1.14 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardOperStatusThe current operational state of the card. | FORCE10-TCF10CardOperStatus Type Values:
| .1.3.6.1.4.1.6027.3.1.1.2.3.1.15 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardFaultStatusThe Fault status of the card. The valid status are as followed: 'on' - the system fault light is on. 'off' - the system fault light is off. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.3.1.16 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardLogStreamReserved field. This fields should return null. | OctetString | .1.3.6.1.4.1.6027.3.1.1.2.3.1.17 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardCountryCodeThe card manufacturer's country code | OctetString Constraints: range: 2-2 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.18 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardPartNumThe card part number | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.3.1.19 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardProductRevThe card manufacturer's product revision | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.3.1.20 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardProdOrderThe F10 product order number | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.3.1.21 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardParityPhantomErrorCounters indicating Transient Phantom Parity Errors on this card. Applied to Linecards only. | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.22 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardParityRecoverableErrorCounters indicating Transient Recoverable Parity Errors on this card. Applied to Linecards only. | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.23 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysCardParityNonrecovrableErrorCounters indicating Transient Non-Recoverable Parity Errors on this card. Applied to Linecards only. | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.3.1.24 |
chSysPortTable
table.1.3.6.1.4.1.6027.3.1.1.2.4
·
1 row entry
·
7 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysPortTable'
A list of ports in a slot.
A port entry containing objects for a
particular slot.
particular slot.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chSysPortSlotIndexA unique index for each slot within the chassis. This value is determined by the chassis slot number where the card is inserted. Valid entries are 1 to the value of chNumSlots | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.4.1.1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysPortIndexA unique index for each slot within the card. This value is determined by the variable chSysSlotNumPorts. This value can also be determined by the chSysCardType. Valid entries are 1 to the value of number of ports avail… | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.4.1.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysPortTypeThe type of port in the card. | FORCE10-TCF10SystemPortType Type Values:
| .1.3.6.1.4.1.6027.3.1.1.2.4.1.3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysPortAdminStatusThe admin status of the card. The port admin status is Up if the user has configured it to be up otherwise, the admin status is Down. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.4.1.4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysPortOperStatusThe operational status provides further condition of the card. If the chSysPortAdminStatus is 'up', the valid state is 'ready' - the card is present and ready and the chSysPortAdminStatus status is 'up'.… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.4.1.5 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysPortIfIndexThe index of ifIndex in the Interface Mib. This index can link to the ifEntry to get this interface/port information | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.4.1.6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| chSysXfpRecvPowerThe power signal strength (dB) received for interface on 10G linecard. | dBFORCE10-TCF10HundredthdB | .1.3.6.1.4.1.6027.3.1.1.2.4.1.7 |
chSysProcessorTable
table.1.3.6.1.4.1.6027.3.1.1.2.6
·
1 row entry
·
7 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysProcessorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysProcessorTable'
A list of Processors resident in this slot.
A list of Processor entries.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chSysProcessorSlotIndexA unique index for each slot within the chassis. This value is determined by the chassis slot number where the card is inserted. Valid entries are 1 to the value of chNumSlots | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.6.1.1 | ||||||||||||
| chSysProcessorIndexA unique index for each Processor within the card. This value is determined by the variable chSysSlotNumProcessors. the valid entries are 1 to the value of number of processors | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.6.1.2 | ||||||||||||
| chSysProcessorModuleThe type of module running on the Processor. | FORCE10-TCF10ProcessorModuleType Type Values:
| .1.3.6.1.4.1.6027.3.1.1.2.6.1.3 | ||||||||||||
| chSysProcessorUpTimeThe SysUpTime for this Processor. | SNMPv2-SMITimeTicks Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.6027.3.1.1.2.6.1.4 | ||||||||||||
| chSysProcessorNvramSizeTotal Non-volatile RAM in Kbytes. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.6.1.5 | ||||||||||||
| chSysProcessorMemSizeThe size of the RAM in Mb. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.6.1.6 | ||||||||||||
| chSysProcessorLogStreamReserved field. Currently, this field should return NULL. | OctetString | .1.3.6.1.4.1.6027.3.1.1.2.6.1.7 |
chSysSwModuleTable
table.1.3.6.1.4.1.6027.3.1.1.2.7
·
1 row entry
·
12 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysSwModuleTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysSwModuleTable'
A list of software version information in a processor.
A software module entry containing version
number information for a particular processor.
number information for a particular processor.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| chSysSwSlotIndexA unique index for each slot within the chassis. This value is determined by the chassis slot number where the card is inserted. Valid entries are 1 to the value of chNumSlots | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.7.1.1 | ||||
| chSysSwProcessorIndexA unique index for each CPU within the card. This value is determined by the variable chSysSlotNumCPUs. This value can also be determined by the chSysSlotType. Valid entries are 1 to the value of number of cpu | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.7.1.2 | ||||
| chSysSwRuntimeImgVersionThis variable indicates the software module version that is currently running on the processor. The software release version is in the format as follow: <major version>.<minor version>.<minor version>...... '1.1' indica… | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.7.1.3 | ||||
| chSysSwRuntimeImgDateThe release date of this software module. | FORCE10-TCF10SwDate | .1.3.6.1.4.1.6027.3.1.1.2.7.1.4 | ||||
| chSysSwCurrentBootImgVersionThe software release version is in the format as follow: <major version>.<minor version>.<minor version>...... '1.1' indicate major version of 1 and minor release of 1. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.7.1.5 | ||||
| chSysSwCurrentBootImgDateThe release date of this software module If the CPU is reset, the software module running date (chSysSwModuleRunningDate) will change to this current date. | SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … | .1.3.6.1.4.1.6027.3.1.1.2.7.1.6 | ||||
| chSysSwCurrentBootImgStatusThe status of current boot image. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.7.1.7 | ||||
| chSysSwBackupBootImgVersionThe software release version is in the format as follow: <major version>.<minor version>.<minor version>...... '1.1' indicate major version of 1 and minor release of 1. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.7.1.8 | ||||
| chSysSwBackupBootImgDateThe backup boot image released date. | SNMPv2-TCDateAndTime Type Constraints: range: 8range: 11Description: A date-time specification. field octets contents range ----- ------ -------- ----- 1 1-2 year* 0..65536 2 3 month … | .1.3.6.1.4.1.6027.3.1.1.2.7.1.9 | ||||
| chSysSwBackupBootImgStatusThe status of the backup boot image. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.7.1.10 | ||||
| chSysSwNextRebootImageThe boot flash image selection. When the chassis is rebooted, this is the boot image to use. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.7.1.11 | ||||
| chSysSwCurrentBootImageThe current boot image. This is the boot image described by the chSysSwCurrentBootImgVersion, chSysSwCurrentBootImgDate, and chSysSwCurrentBootImgStatus objects. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.7.1.12 |
chSysSfmTable
table.1.3.6.1.4.1.6027.3.1.1.2.8
·
1 row entry
·
12 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chSysSfmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chSysSfmTable'
A list of Swicth Fabric Module in a slot.
A SFM entry containing objects for a
particular slot.
particular slot.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| chSysSfmIndexA unique index for each SFM within the chassis. The number of SFM slots can be determined with chNumSfmSlots. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.8.1.1 | ||||||||
| chSysSfmSerialNumberThe serial number of the SFM. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.8.1.2 | ||||||||
| chSysSfmVendorIdThe vendor id that manufactured the SFM. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.8.1.3 | ||||||||
| chSysSfmMfgDateThe date the SFM is manufactured. | FORCE10-TCF10MfgDate | .1.3.6.1.4.1.6027.3.1.1.2.8.1.4 | ||||||||
chSysSfmEcLeveldeprecated The EC Level of the SFM. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.2.8.1.5 | ||||||||
| chSysSfmAdminStatusThe admin status of each SFM. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.8.1.6 | ||||||||
| chSysSfmOperStatusThe Operational status provides further condition of Switch Fabric Module card. If the chSysSfmAdminStatus is 'up', the valid state is 'active' - the card is present and ready and the chSysSfmAdminStatus … | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.8.1.7 | ||||||||
| chSysSfmErrorStatusThe Operational status provides further condition of Switch Fabric Module card. If the chSysSfmAdminStatus is 'up', the valid state is 'ok' - the card is present and ready and the chSysSfmAdminStatus sta… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.6027.3.1.1.2.8.1.8 | ||||||||
| chSysSfmCountryCodeThe SFM manufacturer's country code | OctetString Constraints: range: 2-2 | .1.3.6.1.4.1.6027.3.1.1.2.8.1.9 | ||||||||
| chSysSfmPartNumThe SFM manufacturer's part number | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.8.1.10 | ||||||||
| chSysSfmProductRevThe SFM manufacturer's product revision | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.8.1.11 | ||||||||
| chSysSfmProdOrderThe SFM product order number. | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.6027.3.1.1.2.8.1.12 |
chRpmUtilTable
table.1.3.6.1.4.1.6027.3.1.1.3.7
·
1 row entry
·
6 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chRpmUtilTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chRpmUtilTable'
A table listing the cpu and memory utilization in master RPM.
A row in each processor cpu and mmory utilization
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| chRpmCpuIndexA unique index for each Processor within the RPM. This value is determined by the variable chSysSlotNumProcessors. the valid entries are 1 to the value of number of processors | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.6027.3.1.1.3.7.1.1 | ||||||||||||
| chRpmCpuTypeThe type of module running on the Processor. | FORCE10-TCF10ProcessorModuleType Type Values:
| .1.3.6.1.4.1.6027.3.1.1.3.7.1.2 | ||||||||||||
| chRpmCpuUtil5SecCPU utilization in percentage for last 5 seconds. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.3.7.1.3 | ||||||||||||
| chRpmCpuUtil1MinCPU utilization in percentage for last 1 minute. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.3.7.1.4 | ||||||||||||
| chRpmCpuUtil5MinCPU utilization in percentage for last 5 minutes. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.3.7.1.5 | ||||||||||||
| chRpmMemUsageUtilTotal RPM's memory usage in percentage. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.3.7.1.6 |
chLineCardUtilTable
table.1.3.6.1.4.1.6027.3.1.1.5.1
·
1 row entry
·
4 columns
Uses the force10 variant from
Command help
/opt/observium/mibs/force10.
Walk chLineCardUtilTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'F10-CHASSIS-MIB' -M '/opt/observium/mibs/force10:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'F10-CHASSIS-MIB::chLineCardUtilTable'
A table listing the cpu and memory utilization in line cards.
A row in each line card cpu and memory utilization
Indexes
| Column | Syntax | OID |
|---|---|---|
| chLineCardCpuUtil5SecCPU utilization in percentage for last 5 seconds. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.5.1.1.1 |
| chLineCardCpuUtil1MinCPU utilization in percentage for last 1 minute. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.5.1.1.2 |
| chLineCardCpuUtil5MinCPU utilization in percentage for last 5 minutes. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.5.1.1.3 |
| chLineCardMemUsageUtilMemory usage in percentage. | percentUnsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.6027.3.1.1.5.1.1.4 |