EdgeSwitch-BOXSERVICES-PRIVATE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
4
Rows
4
Columns
18
.1.3.6.1.4.1.4413.1.1.43.1.6 · 1 row entry · 6 columns
Uses the ubiquiti variant from /opt/observium/mibs/ubiquiti.
Command help
Walk boxServicesFansTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB::boxServicesFansTable'
Fan
boxServicesFansEntry row .1.3.6.1.4.1.4413.1.1.43.1.6.1
Box Services Fan Entry
Column Syntax OID
Unique index of fan table entry
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.4413.1.1.43.1.6.1.1
The type of fan
Enumeration
Enumerated Values:
1fixed
2removable
3fixedAC
4removableDC
5fixedDC
6removableAC
.1.3.6.1.4.1.4413.1.1.43.1.6.1.2
The status of fan. nopower(4) - This state means the fan is present but no AC is connected.
Enumeration
Enumerated Values:
1notpresent
2operational
3failed
4powering
5nopower
6notpowering
7incompatible
.1.3.6.1.4.1.4413.1.1.43.1.6.1.3
The speed of fan
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4413.1.1.43.1.6.1.4
The duty level of fan, in percents
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4413.1.1.43.1.6.1.5
Unit index for an entry in the Box Services Fan Table
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.1.1.43.1.6.1.6
.1.3.6.1.4.1.4413.1.1.43.1.7 · 1 row entry · 4 columns
Uses the ubiquiti variant from /opt/observium/mibs/ubiquiti.
Command help
Walk boxServicesPowSuppliesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB::boxServicesPowSuppliesTable'
Power supply
boxServicesPowSuppliesEntry row .1.3.6.1.4.1.4413.1.1.43.1.7.1
Box Services Power Supply Entry
Column Syntax OID
Unique index of power supply table entry
Integer32
Constraints:
range: 0-2147483647
.1.3.6.1.4.1.4413.1.1.43.1.7.1.1
The type of power supply
Enumeration
Enumerated Values:
1fixed
2removable
3fixedAC
4removableDC
5fixedDC
6removableAC
.1.3.6.1.4.1.4413.1.1.43.1.7.1.2
The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
incompatible(7) - This state is possible on boards capable of pluggable Power supplies
Enumeration
Enumerated Values:
1notpresent
2operational
3failed
4powering
5nopower
6notpowering
7incompatible
.1.3.6.1.4.1.4413.1.1.43.1.7.1.3
Unit index for an entry in the Box Services Power Supply Table
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.1.1.43.1.7.1.4
.1.3.6.1.4.1.4413.1.1.43.1.8 · 1 row entry · 5 columns
Uses the ubiquiti variant from /opt/observium/mibs/ubiquiti.
Command help
Walk boxServicesTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable'
Temperature sensor
boxServicesTempSensorsEntry row .1.3.6.1.4.1.4413.1.1.43.1.8.1
Box Services Temperature Sensor Entry
Column Syntax OID
Unit index for an entry in the Box Services Temperature Sensor Table
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.1.1.43.1.8.1.1
Unique index of temperature sensor table entry
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.1.1.43.1.8.1.2
The type of temperature sensor
Enumeration
Enumerated Values:
1fixed
2removable
3fixedAC
4removableDC
5fixedDC
6removableAC
.1.3.6.1.4.1.4413.1.1.43.1.8.1.3
The state of temperature sensor
BoxsTemperatureStatus
Type Values:
0low
1normal
2warning
3critical
4shutdown
5notpresent
6notoperational
.1.3.6.1.4.1.4413.1.1.43.1.8.1.4
The temperature value reported by sensor
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4413.1.1.43.1.8.1.5
.1.3.6.1.4.1.4413.1.1.43.1.15 · 1 row entry · 3 columns
Uses the ubiquiti variant from /opt/observium/mibs/ubiquiti.
Command help
Walk boxServicesTempUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/ubiquiti:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EdgeSwitch-BOXSERVICES-PRIVATE-MIB::boxServicesTempUnitTable'
Temperature status table
boxServicesTempUnitEntry row .1.3.6.1.4.1.4413.1.1.43.1.15.1
Box Services Temperature Unit Entry
Column Syntax OID
Unit index for an entry in the Box Services Temperature Unit Table
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.4413.1.1.43.1.15.1.1
The temperature state of the unit
BoxsTemperatureStatus
Type Values:
0low
1normal
2warning
3critical
4shutdown
5notpresent
6notoperational
.1.3.6.1.4.1.4413.1.1.43.1.15.1.2
The highest temperature currently reported by any sensor on the unit
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.4413.1.1.43.1.15.1.3