EMAP-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
46
Rows
46
Columns
532
hwSiteActiveAlarmTable
table.1.3.6.1.4.1.2011.6.164.1.1.2.99
·
1 row entry
·
12 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteActiveAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteActiveAlarmTable'
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwActiveAlarmIndexSite active alarm table index. It is the unique ID of the site alarm. | Integer32 Constraints: range: 1-65535 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.1 | ||||||||||||
| hwActiveAlarmTextActive alarm name. It is of the character string type, and used to specify the content of a specific alarm. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.2 | ||||||||||||
| hwActiveAlarmLevelActive alarm level, which users can configure the alarm severity, is an enumeration type: If the enumeration value is 1, it indicates a critical alarm; If the enumeration value is 2, it indicates a major alarm; If the e… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.3 | ||||||||||||
| hwActiveAlarmSigDescActive alarm signal description. It is used to add and describe alarm content. Users can define the description of the alarm. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.4 | ||||||||||||
| hwActiveAlarmTimeActive alarm time. It is of the character string type, and used to specify the content of a specific alarm. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.5 | ||||||||||||
| hwSMUSiteNameSite name, which users can configure, is used to specify a site. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.6 | ||||||||||||
| hwSMUSiteAdminAddrSite administrant address, which users can assigned, is the unique ID of a site. It is used for device management by NMS, and value range is 0 to 65535. | Unsigned32 Constraints: range: 0-65535 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.7 | ||||||||||||
| hwSMUNetIdentifierNE ID. It is of the character string type. It is the unique ID of the site (an independent network element (NE)) on the network. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.8 | ||||||||||||
| hwSMUSiteDescriptionSite description. It is of the character string type. It is used to describe the site information such as the site location, which users can configure. Otherwise, the configured character can not be any other languages… | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.9 | ||||||||||||
| hwEquipIdEquipment ID. Value range: 000,000 to 000,100, in which the first three digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.10 | ||||||||||||
| hwEquipNameEquipment name. It is of the character string type, and users can set the name of the monitor. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.11 | ||||||||||||
| hwActiveAlarmRowStatusRowstatus of active alarm table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.1.2.99.1.100 |
hwSiteAlarmTable
table.1.3.6.1.4.1.2011.6.164.1.1.2.100
·
1 row entry
·
5 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteAlarmTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwAlarmIndexSite alarm table index. It is the unique ID of the site alarm. | Unsigned32 Constraints: range: 1-4294967295 | .1.3.6.1.4.1.2011.6.164.1.1.2.100.1.1 | ||||||||||||
| hwAlarmTextAlarm name. It is of the character string type, and used to specify the content of a specific alarm. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.1.2.100.1.2 | ||||||||||||
| hwAlarmLevelAlarm level, which users can configure the alarm severity, is an enumeration type: If the enumeration value is 1, it indicates a critical alarm; If the enumeration value is 2, it indicates a major alarm; If the enumerat… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.1.2.100.1.3 | ||||||||||||
| hwAlarmSigDescAlarm signal description. It is used to add and describe alarm content. Users can define the description of the alarm. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.1.2.100.1.4 | ||||||||||||
| hwAlarmRowStatusRowStatus of site alarms table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.1.2.100.1.100 |
hwMonitorTable
table.1.3.6.1.4.1.2011.6.164.1.2.2.1
·
1 row entry
·
14 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwMonitorTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwMonIndexTable index of the site monitors (hwSiteMonitorTable) is restricted by the quantity of the site monitors (hwMonsQuantity). Value range: 1 to 100. | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.1 | ||||||||||||
| hwMonEquipIdSite monitor ID. Value range: 001,001 to 001,100, in which the first three digits indicate the device type and the last three digits indicate the device SN. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.2 | ||||||||||||
| hwMonEquipNameMonitor name. It is of the character string type, and users can set the name of the monitor. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.3 | ||||||||||||
| hwMonEquipDescriptionMonitor description. It is of the character string type. Users can set the description of the monitor. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.4 | ||||||||||||
| hwMonEquipSoftwareVersionMonitor software version. It is of the character string type. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.5 | ||||||||||||
| hwMonEquipPcbVersionMonitor printed circuit board (PCB) hardware version. It is of the character string type. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.6 | ||||||||||||
| hwMonEquipManufacturerMonitor manufacture. It is of the character string type, and is an inherent attribute of the device. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.7 | ||||||||||||
| hwMonEquipManuDateMonitor production date. It is of the character string type, and is an inherent attribute of the device. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.8 | ||||||||||||
| hwMonEquipSerialNoProduction SN of the monitor. It is the electronic tag of the products. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.9 | ||||||||||||
| hwMonEquipOperTotalTimeTotal monitor runtime. The monitor counts the data in real time. Value range is 0 to 65535, The value is an integer (1), Units:hours. (h). It is used for performance measurement and evaluation of the monitor. | Unsigned32 Constraints: range: 0-65535 | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.10 | ||||||||||||
| hwSetMonEquipCtrlStateMonitor control status. It is an enumeration type: If the enumeration value is 1, it indicates the background control; If the enumeration value is 2, it indicates the automatic control. If the enumeration value is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.11 | ||||||||||||
| hwCtrlMonEquipResetWarm-reset control of the monitor. It is an enumeration type: If the enumeration value is 1, it indicates the Warm-reset control of the monitor is normal; If the enumeration value is 2, it indicates the Warm-reset contr… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.12 | ||||||||||||
| hwMonitorOperStatusState of the site monitor module. It is an enumeration type: If the enumeration value is 1, it indicates that the site monitor module is in the normal state; If the enumeration value is 2, it indicates that the monitor… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.99 | ||||||||||||
| hwMonRowStatusRowStatus of site monitor. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.2.2.1.1.100 |
hwRectConfigTable
table.1.3.6.1.4.1.2011.6.164.1.3.2.1
·
1 row entry
·
13 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwRectConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwRectConfigTable'
Rectifier config information table. Use this table to get rectifiers equipment ID, software version, manufacturer, rated current, efficency, AC input type, and to control equipment on or off. This table's index is hwRectConfigIndex, clone Rectifier config information table.
Rectifier config information table. Use this table to get rectifiers equipment ID, software version, manufacturer, rated current, efficency, AC input type, and to control equipment on or off.
This table's index is hwRe…
This table's index is hwRe…
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwRectConfigIndexIndex of the device configuration list for the rectifier modules, which value range: 1 to 256(To the actual subject). Lines of the device list are restricted by the total quantity of the rectifier modules (hwRectsTotalQ… | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.1 | ||||||||||||
| hwRectEquipIdRectifier module ID. Value range: 002'001 to 002'255. The first digits indicate the device type and last three digits indicate the device SN. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.2 | ||||||||||||
| hwRectEquipNameDevice name of the rectifier module, character string type, is used to specify the rectifier module. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.3 | ||||||||||||
| hwRectTypeSpecific type of the rectifier module. It is an enumeration type: If the enumeration value is 1, it indicates a 5A rectifier module; If the enumeration value is 2, it indicates a 15A rectifier module; If the enumerati… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.4 | ||||||||||||
| hwRectSoftwareVersionSoftware version of the rectifier module. It indicates the software version ID of the module. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.5 | ||||||||||||
| hwRectManufacturerManufacture of the rectifier module. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.6 | ||||||||||||
| hwRectManuDateManufacture date of rectifiers is of string type. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.7 | ||||||||||||
| hwRectSerialNoRectifier module SN. It indicates the electronic tag of the product. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.8 | ||||||||||||
| hwRectRatedCurrentRated voltage of the rectifier module, is an inherent attribute. Value range: 0 to 200, Units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Unsigned32 Constraints: range: 0-2000 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.9 | ||||||||||||
| hwRectEfficencyEfficiency of the rectifier module, is an inherent attribute. Value range: 0 to 100, Units: %, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.10 | ||||||||||||
| hwRectInputAcTypeInput AC type of the rectifier module. It is an enumeration value: If the value of the node is 1, it indicates single-phase AC input; If the value of the node is 2, it indicates three-phase AC input; If the value of th… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.11 | ||||||||||||
| hwCtrlRectOnOffPower-on or power-off of the rectifier module, is an enumeration value. Users can modify the enumeration value of this node, thus controlling of the power-on or power-off of the rectifier module: If the NMS notifies the… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.12 | ||||||||||||
| hwRectConfigRowStatusRowStatus of rectifier config table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.3.2.1.1.100 |
hwRectOperTable
table.1.3.6.1.4.1.2011.6.164.1.3.2.2
·
1 row entry
·
10 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwRectOperTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwRectOperTable'
Rectifier runing information table. Use this table to get rectifiers output current, output voltage, totle runing time, and current run status. This table's index is hwRectRunIndex, clone rectifier runing information table.
Rectifier runing information table. Use this table to get rectifiers output current, output voltage, totle runing time, and current run status.
This table's index is hwRectRunIndex, clone rectifier runing information t…
This table's index is hwRectRunIndex, clone rectifier runing information t…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwRectOperIndexTable index of the running rectifier modules, which value range: 1 to 256(To the actual subject). Lines of the device list are restricted by the total quantity of the rectifier modules (hwRectsTotalQuantity). | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.1 | ||||||||||||||||||||||
| hwRectOutputCurrentOutput current of the rectifier module. It is a real-time analog parameter. Value range: 0 to 300, Units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates … | Unsigned32 Constraints: range: 0-3000 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.2 | ||||||||||||||||||||||
| hwRectOutputVoltageOutput voltage of the rectifier module. It is a real-time analog parameter. Value range: 0 to 65, Units: V, the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that … | Unsigned32 Constraints: range: 0-650 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.3 | ||||||||||||||||||||||
| hwRectTotalOperTimeTotal runtime of the rectifier module. Value units: minute (m), and the value is an integer (1). | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.4 | ||||||||||||||||||||||
| hwRectDCOutputPowerDC output power. Value range: 0 to 30000, units: W, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-30000 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.5 | ||||||||||||||||||||||
| hwRectACVoltageAC input voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-6000 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.6 | ||||||||||||||||||||||
| hwRectRatedEfficiencyRated Efficiency. Value range: 0 to 100, units: %, and the value is an integer.(1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.7 | ||||||||||||||||||||||
| hwRectifierTemperatureRectifier Temperature. Value range: -300 to 300, units: degC, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -3000-3000 | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.8 | ||||||||||||||||||||||
| hwRectOperStatusState of the rectifier module. It is an enumeration type: If the enumeration value is 1, the rectifier module is in the normal state; If the enumeration value is 2, a fault occurs on the rectifier module; If the enume… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.99 | ||||||||||||||||||||||
| hwRectOperRowStatusRowStatus of rectifier runing table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.3.2.2.1.100 |
hwBattsTestResultTable
table.1.3.6.1.4.1.2011.6.164.1.4.3.100
·
1 row entry
·
12 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwBattsTestResultTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwBattsTestResultTable'
Battery test result record table. Use this table to get battery test inital time, test result, battery efficiency, battery discharge time, terminated voltage, average current, discharge AH value, test temperature and test terminated course. This table's index is hwBattsTestResultIndex, clone Battery test result record table.
Battery test result record table.
Use this table to get battery test inital time, test result, battery efficiency, battery discharge time, terminated voltage, average current, discharge AH value, test temperature and t…
Use this table to get battery test inital time, test result, battery efficiency, battery discharge time, terminated voltage, average current, discharge AH value, test temperature and t…
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwBattsTestResultIndexTable index of the battery test results. Currently up to 10 times of the battery test results are saved by default. | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.1 | ||||||||||||||||
| hwBattsTestTypeRecord test type of the battery test. It is an enumeration value: If the NMS notifies the SNMP agent that this node is set to 1, it indicates a manual test; If the NMS notifies the SNMP agent that this node is set to … | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.2 | ||||||||||||||||
| hwBattsTestStartTimeTest start time of the record in the battery test. It is of the character string type. | OctetString Constraints: range: 0-127 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.3 | ||||||||||||||||
| hwBattsTestResultBattery test result. It is an enumeration value. If the enumeration value of the node is 1, it indicates that the battery test has no result: If the enumeration value of the node is 2, it indicates that the battery is … | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.4 | ||||||||||||||||
| hwBattsEfficiencyBattery efficiency test. Value range: 0 to 100, Units: %, and the value is an integer (1). If the value is -1, it indicates that the test value is inefficient. If the value is 255, it indicates that the test valu… | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.5 | ||||||||||||||||
| hwBattsDischargeTimeDischarge time of the battery test records. Value range: 0 to 100, units: hour (h), and the value is accurate to two decimal places (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inva… | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.6 | ||||||||||||||||
| hwBattsDischargeEndVoltageDischarge termination voltage of the battery test. Value range: 0 to 60, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-600 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.7 | ||||||||||||||||
| hwBattsDischargeAvCurrentAverage discharge current of the battery test. Value range: -1000 to 1000, units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inval… | Integer32 Constraints: range: -10000-10000 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.8 | ||||||||||||||||
| hwBattsDischargeAhValueDischarge ampere per hour the battery test. Value range: 0 to 5000, Units: Ah, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-5000 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.9 | ||||||||||||||||
| hwBattsTestTemperatureBattery temperature of the battery test termination. Value range: -50 to +100, Units: centigrade (degC), and the value is an integer (1). If the value is -1024, it indicates that no battery temperature value sensor … | Integer32 Constraints: range: -50-100 | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.10 | ||||||||||||||||
| hwBattsTestEndCourseTermination factors of the battery test. It is an enumeration value. If the enumeration value is 1, it indicates that the voltage value of the battery test reaches the set termination voltage; If the enumeration value… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.11 | ||||||||||||||||
| hwBattsTestResultRowStatusRowStatus of battery test table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.4.3.100.1.100 |
hwBattStringConfigTable
table.1.3.6.1.4.1.2011.6.164.1.4.4.1
·
1 row entry
·
10 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwBattStringConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwBattStringConfigTable'
Battery string config table. Use this table to get battery string equipment ID and equipment name, to set battery standard capacity and battery install time as well. This table's index is hwBattStringConfigIndex, clone battery string config table.
Battery string config table. Use this table to get battery string equipment ID and equipment name, to set battery standard capacity and battery install time as well. This table's index is hwBattStringConfigIndex, clone …
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwBattStringConfigIndexDevice table index of the battery string, value range: 1 to 100(To the actual subject). | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.1 | ||||||||||||
| hwBattStringEquipIdBatteries device ID, can be configured by users. Value range: 003,001 to 003,100, in which the first three digits specify the device type and the last three specify the device SN. | Unsigned32 Constraints: range: 3001-3100 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.2 | ||||||||||||
| hwBattStringEquipNameBatteries device name, of the character string type, is used to specify the batteries. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.3 | ||||||||||||
| hwSetBattsTempUpperLimitUpper threshold of the battery temperature alarm, can be configured by users. Value range: 25 to 80, Units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates t… | Integer32r/w Constraints: range: 25-80 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.4 | ||||||||||||
| hwSetBattsTempLowerLimitLower threshold of the battery temperature alarm, can be configured by users. Value range: -20 to 20, Units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates … | Integer32r/w Constraints: range: -20-20 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.5 | ||||||||||||
| hwSetBattsTempMeasureUpperLimitUpper threshold of the battery temperature measurement, can be configured by users. Value range: 0 to 100, Units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indic… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.6 | ||||||||||||
| hwSetBattsTempMeasureLowerLimitLower threshold of the battery temperature measurement, can be configured by users. Value range: -50 to 0, Units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indic… | Integer32r/w Constraints: range: -50-0 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.7 | ||||||||||||
| hwSetBattStdCapacitySet battery standard capacity, is an inherent attribute of the device. Value range: 5 to 10000, units: Ah, the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invali… | Integer32r/w Constraints: range: 5-10000 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.8 | ||||||||||||
| hwSetBattInstallTimeSet battery install time, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-128 | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.9 | ||||||||||||
| hwBattStringConfigRowStatusRowStatus of battery string config table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.4.4.1.1.100 |
hwBattStringOperTable
table.1.3.6.1.4.1.2011.6.164.1.4.4.2
·
1 row entry
·
9 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwBattStringOperTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwBattStringOperTable'
Battery string runing table. Use this table to get battery string current, persent of remain capacity, battery remain capacity, battery actual capacity, as well as battery temperature. This table's index is hwBattStringRunIndex, clone battery string runing table.
Battery string runing table. Use this table to get battery string current, persent of remain capacity, battery remain capacity, battery actual capacity, as well as battery temperature.
This table's index is hwBattStri…
This table's index is hwBattStri…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwBattStringOperIndexDevice table index of the battery string, which value range: 1 to 100(To the actual subject). | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.1 | ||||||||||||||||||||
| hwBattStringCurrentBatteries current. It is an analog parameter collected by the battery string in real time. Value range: -1000 to +1000, units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7F… | Integer32 Constraints: range: -10000-10000 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.2 | ||||||||||||||||||||
| hwBattStringRemainCapacityPercentRemaining capacity percentage of the battery string. Value range: 0 to 100, units: %, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inva… | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.3 | ||||||||||||||||||||
| hwBattStringRemainCapacityRemaining capacity of the battery string. It is an analog parameter collected by the battery string in real time. Value range: 0 to 1000, units: Ah, and the value is an integer (1). If the value is 2147483647(0x7FF… | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.4 | ||||||||||||||||||||
| hwBattStringActualCapacityBatteries actual capacity. It is an analog parameter collected by the battery string in real time. Value range: 0 to 5000, units: Ah, the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates… | Unsigned32 Constraints: range: 0-5000 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.5 | ||||||||||||||||||||
| hwBattStringTempratureBattery temperature. It is a battery parameter collected in real time. Value range: -300 to +200, unit: centigrade (degC), and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), … | Integer32 Constraints: range: -3000-2000 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.6 | ||||||||||||||||||||
| hwBattStringMidpointVoltageBatteries midpoint voltage. It is an analog parameter collected by the battery string in real time. Value range: -90 to +90, unit: V, and the value is accurate to one decimal place (.1). | Integer32 Constraints: range: -900-900 | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.7 | ||||||||||||||||||||
| hwBattStringOperStatusState of the site battery string module. It is an enumeration type: If the enumeration value is 1, it indicates that the site battery string is in the normal state; If the enumeration value is 2, it indicates that the… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.99 | ||||||||||||||||||||
| hwBattStringOperRowStatusRowStatus of battery string runing table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.4.4.2.1.100 |
hwAcInputTable
table.1.3.6.1.4.1.2011.6.164.1.5.2.1
·
1 row entry
·
12 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcInputTable'
AC input table. Use this table to get AC distribution unit ID, AC distribution unit name, A phase or AB line voltage, B phase or BC line voltage, C phase or CA line voltage, AC input breaker status, as well as AC output breakers quantity, which defines hwAcOutputBreakerTable row number. This table's index is hwAcInputIndex, clone AC input table.
AC input table. Use this table to get AC distribution unit ID, AC distribution unit name, A phase or AB line voltage, B phase or BC line voltage, C phase or CA line voltage, AC input breaker status,
as well as AC outpu…
as well as AC outpu…
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwAcInputIndexACU device table index, which value range: 1 to 100. Lines of the device list are restricted by the total quantity of ACUs (hwAcsInputQuantity). | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.1 | ||||||||||||||||||
| hwAcEquipIdACU device ID, which users can configure. Value range: 004,001 to 004,100, in which The first digits indicate the device type and the last three digits indicate the device SN. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.2 | ||||||||||||||||||
| hwAcEquipNameACU device name, of the character string type, is used to specify the alternating current unit (ACU). Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.3 | ||||||||||||||||||
| hwApOrAblVoltageACU A-phase or AB-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-6000 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.4 | ||||||||||||||||||
| hwBpOrBclVoltageACU B-phase or BC-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-6000 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.5 | ||||||||||||||||||
| hwCpOrCalVoltageACU C-phase or CA-line voltage. Value range: 0 to 600, units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-6000 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.6 | ||||||||||||||||||
| hwAphaseCurrentACU A-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 20000, units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it i… | Integer32 Constraints: range: 0-200000 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.7 | ||||||||||||||||||
| hwBphaseCurrentACU B-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 20000, units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it in… | Integer32 Constraints: range: 0-200000 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.8 | ||||||||||||||||||
| hwCphaseCurrentACU C-phase current. It is an analog parameter collected by the ACU in real time. Value range: 0 to 20000, units: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it i… | Integer32 Constraints: range: 0-200000 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.9 | ||||||||||||||||||
| hwAcInputBreakersQuantityQuantity of the AC air circuit breakers. As the ACU lower-level subset, the node indicates the quantity of the output air circuit breakers contained by each ACU lower-level subset. Value range: 0 to 100. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.10 | ||||||||||||||||||
| hwAcInputOperStatusState of the site AC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC distribution uint is in the normal state; If the enumeration value is 2, it indicates tha… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.99 | ||||||||||||||||||
| hwAcRowStatusRowStatus of ACU. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.5.2.1.1.100 |
hwAcInputBreakerTable
table.1.3.6.1.4.1.2011.6.164.1.5.2.2
·
1 row entry
·
5 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcInputBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcInputBreakerTable'
Ac input breaker table. Use this table to get AC input breaker equipment ID, AC input breaker equipment name, and AC input breaker status. This table's index is hwAcInputBreakerIndex, which qualificated by hwAcInputBreakersQuantity in hwAcInputTable, clone Ac input breaker table.
Ac input breaker table. Use this table to get AC input breaker equipment ID, AC input breaker equipment name, and AC input breaker status. This table's index is hwAcInputBreakerIndex, which qualificated by hwAcInputBrea…
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwAcInputBreakerIndexDevice table index of the AC air circuit breaker. Value range: 1 to 100. An input air circuit breaker device can be uniquely identified through the ACU table index and device index of the AC air circuit breaker. | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.5.2.2.1.1 | ||||||||||||
| hwAcInputBreakerEquipIdAC input air circuit breaker ID. Value range: 005,001 to 005,100. The first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 5001-5100 | .1.3.6.1.4.1.2011.6.164.1.5.2.2.1.2 | ||||||||||||
| hwAcInputBreakerEquipNameAC input air circuit breaker name, of the character string type, can configured by users. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.5.2.2.1.3 | ||||||||||||
| hwAcInputBreakerOperStatusOperation state of the site AC input breaker. It is an enumeration type: If the enumeration value is 1, it indicates that the site AC input breaker is in the normal state; If the enumeration value is 2, it indicates t… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.5.2.2.1.99 | ||||||||||||
| hwAcInputBreakerRowStatusRowStatus of AC input breaker. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.5.2.2.1.100 |
hwDcOutputTable
table.1.3.6.1.4.1.2011.6.164.1.6.2.1
·
1 row entry
·
10 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwDcOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwDcOutputTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwDcOutputIndexDevice table index of the DC units, which value range: 1 to 100. Lines of the device list are restricted by the total quantity of DC units (hwDcsQuantity). | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.1 | ||||||||||||||
| hwDcOutputEquipIdDC unit device ID, which value range: 006,001 to 006,100. The first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 6001-6100 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.2 | ||||||||||||||
| hwDcOutputEquipNameDC unit device name, of the character string type, can be configued by users. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.3 | ||||||||||||||
| hwDcOutputVoltageDC output voltage. It is an analog parameter collected by the DC power in real time. Value range: 0 to 100, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it … | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.4 | ||||||||||||||
| hwDcOutputCurrentDC output current. It is an analog parameter collected by the DC power in real time. Value range: -30000 to 30000, units: A, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF… | Integer32 Constraints: range: -300000-300000 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.5 | ||||||||||||||
| hwDcOutputPowerDC output power. It is an analog parameter collected by the DC power in real time. Value range: 0 to 3000000, units: W, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the… | Unsigned32 Constraints: range: 0-3000000 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.6 | ||||||||||||||
| hwLoadsQuantityQuantity of the DC load output branches, which value range: 0 to 100. As the DC unit lower-level subset, the node indicates the quantity of the DC load output branches contained by each DC unit lower-level subset. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.7 | ||||||||||||||
| hwLoadUsageThe load usage of rated rectifier capacity. Value range: 0 to 100, units: %, and the value is an integer (1). | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.8 | ||||||||||||||
| hwDcOutputOperStatusState of the site DC distribution uint. It is an enumeration type: If the enumeration value is 1, it indicates that the site DC distribution uint is in the normal state; If the enumeration value is 2, it indicates tha… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.99 | ||||||||||||||
| hwDcOutputRowStatusRowStatus of Dc output equipments. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.6.2.1.1.100 |
hwLoadBranchTable
table.1.3.6.1.4.1.2011.6.164.1.6.2.2
·
1 row entry
·
11 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwLoadBranchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwLoadBranchTable'
Loads output table. Use this table to get load branch equipment ID, load branch equipment name, load branch current, and load branch power. This table's index is hwLoadBranchIndex, which qualificated by hwloadsQuantity in hwDcOutputTable, clone loads output table.
Loads output table. Use this table to get load branch equipment ID, load branch equipment name, load branch current, and load branch power. This table's index is hwLoadBranchIndex, which qualificated by hwloadsQuantity …
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwLoadBranchIndexDevice table index of the DC load output branch, which value range: 1 to 100. A DC load output branch can be uniquely identified through the DC unit table index and device index of the DC load output branch. | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.1 | ||||||||||||
| hwLoadBranchEquipIdDevice ID of the DC load output branch. Value range: 007,001 to 007,100. The first digits indicate the device type and the last three digits indicate the SN of the device. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.2 | ||||||||||||
| hwLoadBranchEquipNameDevice name of the DC load output branch, of the character string type, can be configured by users. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.3 | ||||||||||||
| hwLoadBranchCurrentDC load output branch current. It is an analog parameter collected by the load branch in real time. Value range: 0 to 10000, units: A, and the value is accurate to one decimal space (.1). If the value is 2147483647… | Integer32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.4 | ||||||||||||
| hwLoadBranchPowerDC load branch power. It is an analog parameter collected by the DC power in real time. Value range: 0 to 600000, units: W, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that… | Unsigned32 Constraints: range: 0-600000 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.5 | ||||||||||||
| hwLoadBranchConsumeDC load branch power consumption, Value range: 0 to 4294967295, units: KWh, and the value is accurate to one decimal space (.1). | Unsigned32 Constraints: range: 0-4294967295 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.6 | ||||||||||||
| hwLoadBranchConsumptionDC load branch power consumption,Value range: 0 to 4294967295, resolution:1 KWh. | Unsigned32 Constraints: range: 0-4294967295 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.8 | ||||||||||||
| hwLoadBranchConsumptionLow32bLow 32 bits of DC load branch power consumption,Value range: 0 to 4294967295, resolution:10Wh | Unsigned32 Constraints: range: 0-4294967295 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.9 | ||||||||||||
| hwLoadBranchConsumptionHigh32bHigh 32 bits of DC load branch power consumption,Value range: 0 to 4294967295, resolution:10Wh | Unsigned32 Constraints: range: 0-4294967295 | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.10 | ||||||||||||
| hwLoadBranchOperStatusState of the site load output branch. It is an enumeration type: If the enumeration value is 1, it indicates that the site load output branch is in the normal state; If the enumeration value is 2, it indicates that th… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.99 | ||||||||||||
| hwLoadBranchRowStatusRowStatus of loads output branch. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.6.2.2.1.100 |
hwLvdBranchTable
table.1.3.6.1.4.1.2011.6.164.1.7.2.1
·
1 row entry
·
12 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwLvdBranchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwLvdBranchTable'
Power-off unit table. Use this table to get Lvd unit equipment ID and power-off unit equipment name, set power-off enable and power-off voltage, as well as control power-off unit disconnected. This table's index is hwLvdBranchIndex, which qualificated by hwLvdsQuantity, clone power-off unit table.
Power-off unit table. Use this table to get Lvd unit equipment ID and power-off unit equipment name, set power-off enable and power-off voltage, as well as control power-off unit disconnected. This table's index is hwLv…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwLvdBranchIndexDevice table index of a power-off unit. Value range: 1 to 100. Lines of the device list are restricted by the total quantity of the power-off units (hwLvdsTotalQuantity). | Integer32 Constraints: range: 1-100 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.1 | ||||||||||||||||||||||||
| hwLvdUnitEquipIdDevice ID of a power-off unit. Value range: 8001 to 8100. The first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 8001-8100 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.2 | ||||||||||||||||||||||||
| hwLvdUnitEquipNameDevice name of a power-off unit, of the character string type, is used to specify the low-voltage power-off unit. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.3 | ||||||||||||||||||||||||
| hwSetLvdEnableControl power-off unit enabling. It is an enumeration value, and users actively set it. If the enumeration value is 1, it means to enable the power-off unit; If the enumeration value is 2, it means to disable the powe… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.4 | ||||||||||||||||||||||||
| hwSetLvdVoltageLow-voltage power-off voltage of a power-off unit can be configured by users. Its value range: 35 to 56, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it ind… | Integer32r/w Constraints: range: 350-560 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.5 | ||||||||||||||||||||||||
| hwCtrlLvdControl of the power-off unit. It is an enumeration value, users control it manually. If the NMS notifies the SNMP agent that the node is set to 1, it means to power off the power-off unit; If the NMS notifies the SNM… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.6 | ||||||||||||||||||||||||
| hwSetLvdModeSelect the control mode of the power-off unit. It is an enumeration value, users can configure it manually. If the NMS notifies the SNMP agent that the node is set to 1, it means to select the voltage power off mode; … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.7 | ||||||||||||||||||||||||
| hwSetLvdReconnectedVoltageLow-voltage power-off recover of a power-off unit can be configured by users. Its value range: 37.0 to 58.0, unit: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it … | Integer32r/w Constraints: range: 370-580 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.8 | ||||||||||||||||||||||||
| hwSetLvdDisconnectedTimeLow-voltage power-off disconnected time, It can be configured by users, value range defines between 5 to 1000, unit: minutes(min) ?? and its value is an integer (1). Here, if battery manual test is standard mode, If … | Integer32r/w Constraints: range: 5-1000 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.9 | ||||||||||||||||||||||||
| hwSetLvdDisconnectedCapacityPower-off unit control the power off, when Remaining capacity percentage of the battery strings is below the calue. Value range: 0 to 100, unit: %, and the value is accurate to one decimal space (.1). If the value i… | Integer32r/w Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.10 | ||||||||||||||||||||||||
| hwLvdBranchOperStatusState of the site LVD uint. It is an enumeration type: If the enumeration value is 1, the site LVD uint is in the normal state; If the enumeration value is 2, the power-off uint disconnect for low voltage; If the enu… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.99 | ||||||||||||||||||||||||
| hwLvdBranchRowStatusRowStatus of lvd table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.7.2.1.1.100 |
hwEnvTempSensorTable
table.1.3.6.1.4.1.2011.6.164.1.8.2.1
·
1 row entry
·
12 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwEnvTempSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwEnvTempSensorTable'
Site environment temperature table. Use this table to get environment temperature equipment ID, environment temperature equipment name, and environment temperature, set environment temperature upper limit, environment temperature lower limit, and environment temperature alarm enable. This table's index is hwEnvTempSensorIndex, which qualificated by hwEnvTempSensorsQuantity, clone site environment temperature table.
Site environment temperature table.
Use this table to get environment temperature equipment ID, environment temperature equipment name, and environment temperature, set environment temperature upper limit, environment …
Use this table to get environment temperature equipment ID, environment temperature equipment name, and environment temperature, set environment temperature upper limit, environment …
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwEnvTempSensorIndexTable index of the environment temperature sensors. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.1 | ||||||||||||
| hwEnvTempEquipIdEnvironment temperature sensor ID. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.2 | ||||||||||||
| hwEnvTempEquipNameEnvironment temperature sensor name, of the character string type, is used to specify an environment temperature sensor. Users can configure it. Otherwise, the configured character can not be any other languages excep… | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.3 | ||||||||||||
| hwEnvTemperatureEnvironment temperature. It is an environment parameter collected in real time. Value range: -50 to +100, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647, it indicates that the… | Integer32 Constraints: range: -50-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.4 | ||||||||||||
| hwSetEnvTempUpperLimitUpper threshold of the environment temperature alarm, can be configured by users. units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inva… | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.5 | ||||||||||||
| hwSetEnvTempLowerLimitLower threshold of the environment temperature alarm, can be configured by users. units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inv… | SNMPv2-SMIInteger32r/w Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.6 | ||||||||||||
| hwSetEnvTempMeasureUpperLimitUpper threshold of the environment temperature measurement, can be configured by users. Value range: 0 to 100, unit: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it in… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.7 | ||||||||||||
| hwSetEnvTempMeasureLowerLimitLower threshold of the environment temperature measurement, can be configured by users. Value range: -50 to 0, unit: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it in… | Integer32r/w Constraints: range: -50-0 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.8 | ||||||||||||
| hwSetEnvTempAlarmEnableEnvironment temperature alarm. It is an enumeration type: If the enumeration value is 1, enable the alarm of the environment temperature; If the enumeration value is 2, disable the alarm of the environment temperature. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.9 | ||||||||||||
| hwSetEnvTempUltraHighTempThresholdThreshold of the environment ultra high temperature measurement, can be configured by users. unit: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | SNMPv2-SMIUnsigned32r/w Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.10 | ||||||||||||
| hwEnvTempSensorOperStatusState of the site environment temperature sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site environment temperature sensor is in the normal state; If the enumeration value is… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.99 | ||||||||||||
| hwEnvTempSensorRowStatusRowStatus of Environment temperature table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.8.2.1.1.100 |
hwEnvHumiSensorTable
table.1.3.6.1.4.1.2011.6.164.1.8.2.2
·
1 row entry
·
11 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwEnvHumiSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwEnvHumiSensorTable'
Environment humidity table. Use this table to get environment humidity equipment ID , environment humidity equipment name, and environment humidity, set environment humidity upper limit, environment humidity lower limit, and environment humidity alarm enable. This table's index is hwEnvHumiSensorIndex, which qualificated by hwEnvHumiSensorIndex, clone site environment humidity table.
Environment humidity table. Use this table to get environment humidity equipment ID , environment humidity equipment name, and environment humidity, set environment humidity upper limit, environment humidity lower limit…
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwEnvHumiSensorIndexTable index of the environment humility sensors. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.1 | ||||||||||||
| hwEnvHumiEquipIdEnvironment humility sensor ID | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.2 | ||||||||||||
| hwEnvHumiEquipNameEnvironment humility sensor name, of the character string type, is used to specify an environment humility sensor. Users can configure it.Otherwise, the configured character can not be any other languages except Englis… | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.3 | ||||||||||||
| hwEnvHumidityEnvironment humility. It is an environment parameter collected in real time. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the humidity… | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.4 | ||||||||||||
| hwSetEnvHumidityUpperLimitUpper threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.5 | ||||||||||||
| hwSetEnvHumidityLowerLimitLower threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.6 | ||||||||||||
| hwSetEnvHumidityMeasureUpperLimitUpper threshold of the environment humility measurement, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.7 | ||||||||||||
| hwSetEnvHumidityMeasureLowerLimitLower threshold of the environment humility measurement, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the v… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.8 | ||||||||||||
| hwSetEnvHumiAlarmEnableEnvironment humility alarm. It is an enumeration type: If the enumeration value is 1, enable the alarm of the environment humility; If the enumeration value is 2, disable the alarm of the environment humility. The env… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.9 | ||||||||||||
| hwEnvHumiSensorOperStatusState of the site environment humidity sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site environment humidity sensor is in the normal state; If the enumeration value is 2, it… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.99 | ||||||||||||
| hwEnvHumiSensorRowStatusRowStatus of Environment humidity table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.8.2.2.1.100 |
hwSpareDigitalTable
table.1.3.6.1.4.1.2011.6.164.1.8.2.3
·
1 row entry
·
7 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSpareDigitalTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSpareDigitalTable'
Spare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to set Spare digital alarm enable. This table's index is hwSpareDigitalIndex, which qualificated by hwSpareDigitalsTotalQuantity, clone switch input table.
Spare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to set Spare digital alarm enable. This table's index is hwSpareD…
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwSpareDigitalIndexSpare digital table index, which value range: 1 to 256. Lines of the device list are restricted by the quantity of Spare digitals (hwSpareDigitalsTotalQuantity). | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.1 | ||||||||||||
| hwSpareDigitalEquipIdSpare digital device ID. Value range: 011'001 to 011'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 11001-11255 | .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.2 | ||||||||||||
| hwSpareDigitalEquipNameSpare digital name, of the character string type, is used to specify Spare digitals. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-8 | .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.3 | ||||||||||||
| hwSpareDigitalAlarmTensionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a low-tension alarm; If the value of the node is 2, it indicates a high-tension alarm. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.4 | ||||||||||||
| hwSpareDigitalAlarmEnableSpare digital alarm enabling. It is an enumeration type: If the enumeration value is 1, it means to enable the alarm; If the enumeration value is 2, it means to disable the alarm. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.5 | ||||||||||||
| hwSpareDigitalOperStatusState of the site Spare digital. It is an enumeration type: If the enumeration value is 1, it indicates that the Spare digital operation state is normal; If the enumeration value is 2, it indicates that a alarm occurs… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.99 | ||||||||||||
| hwSpareDigitalRowStatusRowStatus of of the site Spare digital. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.8.2.3.1.100 |
.1.3.6.1.4.1.2011.6.164.1.8.2.4
·
1 row entry
·
7 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSpareDigitalOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSpareDigitalOutputTable'
Spare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to set Spare digital alarm enable. This table's index is hwSpareDigitalIndex, which qualificated by hwSpareDigitalsTotalQuantity, clone switch input table.
Spare digital table. Use this table to get Spare digital equipment ID , Spare digital equipment name, and current Spare digital alarm tension, ae well as to set Spare digital alarm enable. This table's index is hwSpareD…
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwSpareDigitalOutputIndexSpare digital table index, which value range: 1 to 256. Lines of the device list are restricted by the quantity of Spare digitals (hwSpareDigitalsTotalQuantity). | Integer32 Constraints: range: 1-256 | .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.1 | ||||||||||||
| hwSpareDigitalOutputEquipIdSpare digital device ID. Value range: 012'001 to 012'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 12001-12255 | .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.2 | ||||||||||||
| hwSpareDigitalOutputEquipNameSpare digital name, of the character string type, is used to specify Spare digitals. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.3 | ||||||||||||
| hwSetSpareDigitalOutputAlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a low-tension alarm; If the value of the node is 2, it indicates a high-tension alarm. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.4 | ||||||||||||
| hwSetSpareDigitalOutputEnableSpare digital alarm enabling. It is an enumeration type: If the enumeration value is 1, it means to enable the alarm; If the enumeration value is 2, it means to disable the alarm. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.5 | ||||||||||||
| hwSpareDigitalOutputOperStatusState of the site Spare digital. It is an enumeration type: If the enumeration value is 1, it indicates that the Spare digital operation state is normal; If the enumeration value is 2, it indicates that a alarm occurs… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.99 | ||||||||||||
| hwSpareDigitalOutputRowStatusRowStatus of Spare digital device table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.8.2.4.1.100 |
hwTemp1Table
table.1.3.6.1.4.1.2011.6.164.1.8.2.5
·
1 row entry
·
7 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwTemp1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwTemp1Table'
Temp1 Table.
Temp1 Table.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwTemp1IndexTable index of the temp1 sensors. Value range: 1 to 256. Lines of the device list are restricted by the quantity of temp1 sensors (hwEnvHumiSensorsTotalQuantity). | Integer32 Constraints: range: 3394-3394 | .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.1 | ||||||||||||||
| hwTemp1EquipIdTemp1 sensor ID, can be configured by users. Value range: 026'000 to 026'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 26000-26255 | .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.2 | ||||||||||||||
| hwTemp1EquipNameTemp1 sensor name, of the character string type, is used to specify an temp1 sensor. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.3 | ||||||||||||||
| hwTemp1ValueTemp1. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value is -1024, it indicates that the temperature sensor is n… | Integer32 Constraints: range: -40-80 | .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.4 | ||||||||||||||
| hwTemp1HighLimitUpper threshold of the temp1 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | Integer32r/w Constraints: range: 25-80 | .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.5 | ||||||||||||||
| hwTemp1LowLimitLower threshold of the temp1 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is … | Integer32r/w Constraints: range: -20-20 | .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.6 | ||||||||||||||
| hwTemp1OperStatusState of the site temp1 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp1 sensor is in the normal state; If the enumeration value is 2, it indicates that the temp1 sens… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.5.1.99 |
hwTemp2Table
table.1.3.6.1.4.1.2011.6.164.1.8.2.6
·
1 row entry
·
7 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwTemp2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwTemp2Table'
Temp2 Table.
Temp2 Table.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwTemp2IndexTable index of the temp2 sensors. Value range: 1 to 256. Lines of the device list are restricted by the quantity of temp2 sensors (hwEnvHumiSensorsTotalQuantity). | Integer32 Constraints: range: 3394-3394 | .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.1 | ||||||||||||||
| hwTemp2EquipIdTemp2 sensor ID, can be configured by users. Value range: 027'000 to 027'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 27000-27255 | .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.2 | ||||||||||||||
| hwTemp2EquipNameTemp2 sensor name, of the character string type, is used to specify an temp2 sensor. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.3 | ||||||||||||||
| hwTemp2ValueTemp2. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value is -1024, it indicates that the temperature sensor is n… | Integer32 Constraints: range: -40-80 | .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.4 | ||||||||||||||
| hwTemp2HighLimitUpper threshold of the temp2 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | Integer32r/w Constraints: range: 25-80 | .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.5 | ||||||||||||||
| hwTemp2LowLimitLower threshold of the temp2 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: -20-20 | .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.6 | ||||||||||||||
| hwTemp2OperStatusState of the site temp2 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp2 sensor is in the normal state; If the enumeration value is 2, it indicates that the temp2 sens… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.6.1.99 |
hwSmokeSensorTable
table.1.3.6.1.4.1.2011.6.164.1.8.2.13
·
1 row entry
·
4 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSmokeSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSmokeSensorTable'
/
/
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| hwSmokeSensorIndexThe tem_hum equip Index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.13.1.1 | ||||
| hwSmokeSensorEquipId/ | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.13.1.2 | ||||
| hwSmokeEquipName/ | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.13.1.3 | ||||
| hwSmokeSensorStatusThe smoke sensor status | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.13.1.4 |
hwWaterSensorTable
table.1.3.6.1.4.1.2011.6.164.1.8.2.14
·
1 row entry
·
4 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwWaterSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwWaterSensorTable'
/
/
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| hwWaterSensorIndexThe tem_hum equip Index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.14.1.1 | ||||
| hwWaterSensorEquipId/ | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.14.1.2 | ||||
| hwWaterEquipName/ | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.14.1.3 | ||||
| hwWaterSensorStatusThe smoke sensor status | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.14.1.4 |
hwDoorSensorTable
table.1.3.6.1.4.1.2011.6.164.1.8.2.15
·
1 row entry
·
4 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwDoorSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwDoorSensorTable'
/
/
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| hwDoorSensorIndexThe tem_hum equip Index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.15.1.1 | ||||
| hwDoorSensorEquipId/ | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.8.2.15.1.2 | ||||
| hwDoorEquipName/ | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.8.2.15.1.3 | ||||
| hwDoorSensorStatusThe smoke sensor status | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.8.2.15.1.4 |
hwInverterTable
table.1.3.6.1.4.1.2011.6.164.1.9.2.1
·
1 row entry
·
26 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwInverterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwInverterTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwInverterIndexInverter table index,which value range:1 to 256.Lines of the device list are restricted by the quantity of Inverter. | Unsigned32 Constraints: range: 1-256 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.1 | ||||||||||||
| hwInverterEquipIdInverter device ID. Value range: 018'001 to 018'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 18001-18255 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.2 | ||||||||||||
| hwInverterEquipNameInverter name, of the character string type, is used to specify Inverters. Users can configure it.Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.3 | ||||||||||||
| hwInverterAcOutputVoltInverter AC Output voltage, Value range: 0.0 to 10000.0. Unit: V. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.4 | ||||||||||||
| hwInverterAcOutputCurrInverter AC Output current, Value range: 0.0 to 10000.0. Unit: A. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.5 | ||||||||||||
| hwInverterAcOutputFreqInverter AC Output frequency, Value range: 0 to 10000. Unit: Hz. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.6 | ||||||||||||
| hwInverterAcOutputActivePowerInverter AC Output power, Value range: 0 to 10000000. Unit: W. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.7 | ||||||||||||
| hwInverterAcOutputVAInverter AC Output power, Value range: 0.0 to 100000.0. Unit: VA. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.8 | ||||||||||||
| hwInverterAcInputVoltInverter AC Input voltage, Value range: 0.0 to 10000.0. Unit: V. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.9 | ||||||||||||
| hwInverterAcInputCurrInverter AC Input current, Value range: 0.0 to 10000.0. Unit: A. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.10 | ||||||||||||
| hwInverterAcInputFreqInverter AC Input frequency, Value range: 0 to 10000. Unit: Hz. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.11 | ||||||||||||
| hwInverterAcInputActivePowerInverter AC Input power, Value range: 0 to 10000000. Unit: W. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.12 | ||||||||||||
| hwInverterAcInputVAInverter AC Input power, Value range: 0.0 to 10000.0. Unit: VA. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.13 | ||||||||||||
| hwInverterDcInputVoltInverter DC Input voltage, Value range: 0.0 to 10000.0. Unit: V. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.14 | ||||||||||||
| hwInverterDcInputCurrInverter DC Input current, Value range: 0 to 10000. Unit: A. and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.15 | ||||||||||||
| hwInverterDcInputPowerInverter DC Input power, Value range: 0 to 10000000. Unit: W. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.16 | ||||||||||||
| hwInverterRevisionInverter software version number. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.17 | ||||||||||||
| hwInverterPhaseNumInverter Number of the phase module, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.18 | ||||||||||||
| hwInverterAcGroupNumInverter Number of AC group, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.19 | ||||||||||||
| hwInverterDcGroupNumInverter Number of DC group, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.20 | ||||||||||||
| hwInverterMajorAlarmNumInverter Number of Major alarm, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.21 | ||||||||||||
| hwInverterMinorAlarmNumInverter Number of Minor alarm, Value range: 0 to 10000. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.22 | ||||||||||||
| hwInverterT2SSerialNumInverter T2S serial number, Value range: 0 to 4294967295. If the value is 4294967295(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-4294967295 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.23 | ||||||||||||
| hwInverterModuleTempInverter module Temperature, Value range: -300 to 10000. Unit: degC. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -300-10000 | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.24 | ||||||||||||
| hwInverterOperStatusState of the Inverter. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the normal state; If the enumeration value is 2, it indicates that the Inverter is in the alarm stat… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.99 | ||||||||||||
| hwInverterRowStatusRowStatus of Inverter table. | RowStatus Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.9.2.1.1.100 |
hwFanTable
table.1.3.6.1.4.1.2011.6.164.1.10.2.1
·
1 row entry
·
14 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwFanTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwFanIndexFan table index,which value range: 1 to 256. Lines of the device list are restricted by the quantity of Fan. | Unsigned32 Constraints: range: 1-256 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.1 | ||||||||||||
| hwFanEquipIdFan device ID. Value range: 020'001 to 020'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 20001-20255 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.2 | ||||||||||||
| hwFanEquipNameFan name, of the character string type, is used to specify Fans. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.3 | ||||||||||||
| hwFanCtrlModeState of the Fan ctrl mode. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in autoControl state; If the enumeration value is 2, it indicates that the fan is in manualControl stat… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.4 | ||||||||||||
| hwFan1StatusState of the Fan1 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2, it indicates that the fan is in fault state; If the enume… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.5 | ||||||||||||
| hwFan2StatusState of the Fan2 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2, it indicates that the fan is in fault state; If the enume… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.6 | ||||||||||||
| hwFan3StatusState of the Fan3 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2, it indicates that the fan is in fault state; If the enume… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.7 | ||||||||||||
| hwFan4StatusState of the Fan4 status. It is an enumeration type: If the enumeration value is 1, it indicates that the fan is in normal state; If the enumeration value is 2, it indicates that the fan is in fault state; If the enume… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.8 | ||||||||||||
| hwFan1SpeedFan1 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.9 | ||||||||||||
| hwFan2SpeedFan2 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.10 | ||||||||||||
| hwFan3SpeedFan3 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.11 | ||||||||||||
| hwFan4SpeedFan4 speed, Value range: 0 to 10000. Unit: rpm. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.12 | ||||||||||||
| hwFanOperStatusState of the fan. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the normal state; If the enumeration value is 2, it indicates that the Inverter is in the fault state; … | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.99 | ||||||||||||
| hwFanRowStatusRowStatus fo fan table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.10.2.1.1.100 |
hwDcAirConditionTable
table.1.3.6.1.4.1.2011.6.164.1.10.2.2
·
1 row entry
·
20 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwDcAirConditionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwDcAirConditionTable'
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwDcAirIndexDc aircondition table index | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.1 | ||||||||||||
| hwDcAirEquipIdDc aircondition device ID. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.2 | ||||||||||||
| hwDcAirEquipNameDc aircondition name, of the character string type, is used to specify Fans. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.3 | ||||||||||||
| hwDcAirCtrlModeState of the Dc aircondition ctrl mode. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in autoControl state; If the enumeration value is 2, it indicates that the Dc a… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.4 | ||||||||||||
| hwDcAirCtrlOnOffState of the Dc aircondition control on or off. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in on state; If the enumeration value is 2, it indicates that the Dc ai… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.5 | ||||||||||||
| hwDcAirRunStatusState of the Dc aircondition run status. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in standby state; If the enumeration value is 2, it indicates that the Dc airc… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.6 | ||||||||||||
| hwDcAirCompressorRunStatusState of the Dc air compressor run status. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in standby state; If the enumeration value is 2, it indicates that the Dc ai… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.7 | ||||||||||||
| hwDcAirInnrFanSpeedDc aircondition innr speed, Value range: 0 to 60000. Unit: rpm, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-60000 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.8 | ||||||||||||
| hwDcAirOuterFanSpeedDc aircondition outer speed, Value range: 0.0 to 60000.0. Unit: rpm, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-60000 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.9 | ||||||||||||
| hwDcAirCompressorRunTimeDc aircondition compressor run time, Value range: 0 to 175200. Unit: h, the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-175200 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.10 | ||||||||||||
| hwDcAirRunTimeDc aircondition run time, Value range: 0 to 175200. Unit: H, the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: 0-175200 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.11 | ||||||||||||
| hwDcAirEnterChannelTempDc aircondition enter channel temperature, Value range:-500.0 to 1000.0. Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -500-1000 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.13 | ||||||||||||
| hwDcAirPowerOnTempPointDc aircondition power on temperature point, Value range:-200 to 800. Unit: degC. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32r/w Constraints: range: -200-800 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.14 | ||||||||||||
| hwDcAirPowerOffTempPointDc aircondition power off temperature point, Value range:-200 to 800 Unit: degC. the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32r/w Constraints: range: -200-800 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.15 | ||||||||||||
| hwAcOffEnergySavingState of the Dc air energy saving status. It is an enumeration type: If the enumeration value is 1, it indicates that the Dc aircondition is in disable state; If the enumeration value is 2, it indicates that the Dc air… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.17 | ||||||||||||
| hwDcAirPowerOnAcOffPointDc aircondition power on ac fail temperature point, Value range:-200 to 800. Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32r/w Constraints: range: -200-800 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.18 | ||||||||||||
| hwDcAirPowerOffAcOffPointDc aircondition compressor start temperature point, Value range:-200 to 800. Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32r/w Constraints: range: -200-800 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.19 | ||||||||||||
| hwDcAirEquipAddressDC Air Device address And the value is an integer (1). | Unsigned32 Constraints: range: 0-255 | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.21 | ||||||||||||
| hwDcAirOperStatusState of the dc aircondition. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the standby state; If the enumeration value is 2, it indicates that the Inverter is in the ru… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.99 | ||||||||||||
| hwDcAirRowStatusRowStatus fo dc aircondition table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.10.2.2.1.100 |
hwSiteAcAmmeterTable
table.1.3.6.1.4.1.2011.6.164.1.11.2.1
·
1 row entry
·
37 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteAcAmmeterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteAcAmmeterTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwAcAmmeterIndexAc Ammeter table index,which value range:4096 to 20479. Lines of the device list are restricted by the quantity of AcAmmeter | Unsigned32 Constraints: range: 4096-20479 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.1 | ||||||||||||
| hwAcAmmeterEquipIdAc Ammeter device ID. Value range: 022'001 to 022'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 22001-22255 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.2 | ||||||||||||
| hwAcAmmeterEquipNameAc Ammeter name, of the character string type, is used to specify Fans. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.3 | ||||||||||||
| hwAcAmmeterFrequencyAc Ammeter frequency, Value range: 0.00 to 1000.00. Unit: Hz. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.4 | ||||||||||||
| hwAcAmmeterPhaseL1VoltageAc Ammeter phase a voltage, Value range: 0.00 to 2000.00. Unit: V. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-200000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.5 | ||||||||||||
| hwAcAmmeterPhaseL2VoltageAc Ammeter phase b voltage, Value range: 0.00 to 2000.0. Unit: V. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-200000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.6 | ||||||||||||
| hwAcAmmeterPhaseL3VoltageAc Ammeter phase c voltage, Value range: 0.00 to 2000.0. Unit: V. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-200000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.7 | ||||||||||||
| hwAcAmmeterSetChannelNumAc Ammeter set channel number, Value range: 1 to 4. Unit: NA. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32r/w Constraints: range: 1-4 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.8 | ||||||||||||
| hwAcAmmeterClearAc Ammeter clear communication failure . It is an enumeration type: If the enumeration value is 1, it indicates that the ac ammeter clear communication failure alarm; | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.9 | ||||||||||||
| hwAcAmmeterTypeAc Ammeter type, Value range: 0 to 65535. And the value is an integer(1). | Unsigned32 Constraints: range: 0-65535 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.10 | ||||||||||||
| hwAcAmmeterVersionAc Ammeter version, of the character string type, is used to specify Ac Ammeter. Users can not configure it. | OctetString Constraints: range: 0-56 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.11 | ||||||||||||
| hwAcAmmeterPhaseL1CurrentCH1Ac Ammeter phase a current of channel 1, Value range: 0.00 to 1000.0. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.12 | ||||||||||||
| hwAcAmmeterPhaseL2CurrentCH1Ac Ammeter phase b current of channel 1, Value range: 0.00 to 1000.0. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.13 | ||||||||||||
| hwAcAmmeterPhaseL3CurrentCH1Ac Ammeter phase c current of channel 1, Value range: 0.00 to 1000.0. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.14 | ||||||||||||
| hwAcAmmeterTotalActivePowerCH1Ac Ammeter phase c current of channel 1, Value range: -1000000.00 to 1000000.00. Unit: kW. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is i… | Integer32 Constraints: range: -100000000-100000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.15 | ||||||||||||
| hwAcAmmeterTotalPowerFactorCH1Ac Ammeter total power factor of channel 1, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.16 | ||||||||||||
| hwAcAmmeterTotalActiveEngryAccCH1Ac Ammeter total active engry acc of channel 1, Value range: 0.00 to 1000000000.00. Unit: kWh. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | Unsigned32 Constraints: range: 0-10000000000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.17 | ||||||||||||
| hwAcAmmeterPhaseL1CurrentCH2Ac Ammeter phase a current of channel 2, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.18 | ||||||||||||
| hwAcAmmeterPhaseL2CurrentCH2Ac Ammeter phase b current of channel 2, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.19 | ||||||||||||
| hwAcAmmeterPhaseL3CurrentCH2Ac Ammeter phase c current of channel 2, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.20 | ||||||||||||
| hwAcAmmeterTotalActivePowerCH2Ac Ammeter phase c current of channel 2, Value range: -1000000.00 to 1000000.00. Unit: kW. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is i… | Integer32 Constraints: range: -100000000-100000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.21 | ||||||||||||
| hwAcAmmeterTotalPowerFactorCH2Ac Ammeter total power factor of channel 2, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.22 | ||||||||||||
| hwAcAmmeterTotalActiveEngryAccCH2Ac Ammeter total active engry acc of channel 2, Value range: 0.00 to 1000000000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is… | Unsigned32 Constraints: range: 0-100000000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.23 | ||||||||||||
| hwAcAmmeterPhaseL1CurrentCH3Ac Ammeter phase a current of channel 3, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.24 | ||||||||||||
| hwAcAmmeterPhaseL2CurrentCH3Ac Ammeter phase b current of channel 3, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.25 | ||||||||||||
| hwAcAmmeterPhaseL3CurrentCH3Ac Ammeter phase c current of channel 3, Value range: 0.00 to 1000.00. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.26 | ||||||||||||
| hwAcAmmeterTotalActivePowerCH3Ac Ammeter phase c current of channel 3, Value range: -1000000.00 to 1000000.00. Unit: kW. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is i… | Integer32 Constraints: range: -100000000-100000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.27 | ||||||||||||
| hwAcAmmeterTotalPowerFactorCH3Ac Ammeter total power factor of channel 3, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.28 | ||||||||||||
| hwAcAmmeterTotalActiveEngryAccCH3Ac Ammeter total active engry acc of channel 3, Value range: 0.00 to 1000000000.00. Unit: kWh. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | Unsigned32 Constraints: range: 0-100000000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.29 | ||||||||||||
| hwAcAmmeterPhaseL1CurrentCH4Ac Ammeter phase a current of channel 4, Value range: 0 to 1000. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.30 | ||||||||||||
| hwAcAmmeterPhaseL2CurrentCH4Ac Ammeter phase b current of channel 4, Value range: 0 to 1000. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.31 | ||||||||||||
| hwAcAmmeterPhaseL3CurrentCH4Ac Ammeter phase c current of channel 4, Value range: 0 to 1000. Unit: A. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.32 | ||||||||||||
| hwAcAmmeterTotalActivePowerCH4Ac Ammeter phase c current of channel 4, Value range: -1000000 to 1000000. Unit: kW. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -100000000-100000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.33 | ||||||||||||
| hwAcAmmeterTotalPowerFactorCH4Ac Ammeter total power factor of channel 4, Value range: -10.00 to 10.00. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.34 | ||||||||||||
| hwAcAmmeterTotalActiveEngryAccCH4Ac Ammeter total active engry acc of channel 4, Value range: 0 to 1000000000. Unit: kWh. and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inv… | Unsigned32 Constraints: range: 0-100000000000 | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.35 | ||||||||||||
| hwAcAmmeterOperStatusState of the Ac Ammeter. It is an enumeration type: If the enumeration value is 1, it indicates that the Ac Ammeter is in the normal state; If the enumeration value is 2, it indicates that the Ac Ammeter is in the faul… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.99 | ||||||||||||
| hwAcAmmeterRowStatusRowStatus fo Ac Ammeter table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.11.2.1.1.100 |
hwDGTable
table.1.3.6.1.4.1.2011.6.164.1.12.2.1
·
1 row entry
·
23 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwDGTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwDGTable'
/
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwDGIndexDG table index,which value range:1 to 256. Lines of the device list are restricted by the quantity of DG. | Integer32 Constraints: range: 0-256 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.1 | ||||||||||||
| hwDGEquipIdDG device ID. Value range: 023'001 to 023'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 23001-23255 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.2 | ||||||||||||
| hwDGEquipNameDevice name of the DG module, character string type, is used to specify the DG module. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.3 | ||||||||||||
| hwDGTypeSpecific type of the DG module. It is an enumeration type: If the enumeration value is 1, it indicates a intelligent DG module; If the enumeration value is 2, it indicates a non_intelligent module; If the enumeration … | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.4 | ||||||||||||
| hwDGAphaseVoltageA-phase voltage. Value range: 0 to 500, units: V, and the value is accurate to one decimal place (.1). | Unsigned32 Constraints: range: 0-5000 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.5 | ||||||||||||
| hwDGBphaseVoltageB-phase voltage. Value range: 0 to 500, units: V, and the value is accurate to one decimal place (.1). | Unsigned32 Constraints: range: 0-5000 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.6 | ||||||||||||
| hwDGCphaseVoltageC-phase voltage. Value range: 0 to 500, units: V, and the value is accurate to one decimal place (.1). | Unsigned32 Constraints: range: 0-5000 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.7 | ||||||||||||
| hwDGAphaseCurrentA-phase current. Value range: 0 to 100, units: A, and the value is an integer (1). | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.8 | ||||||||||||
| hwDGBphaseCurrentB-phase current. Value range: 0 to 100, units: A, and the value is an integer (1). | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.9 | ||||||||||||
| hwDGCphaseCurrentC-phase current. Value range: 0 to 100, units: A, and the value is an integer (1). | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.10 | ||||||||||||
| hwDGOutputPowerDG output power. Value range: 0 to 100, units: kw, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.11 | ||||||||||||
| hwDGFrequencyThe frequency of DG. Value range: 5 to 120, units: Hz, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 50-1200 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.12 | ||||||||||||
| hwDGBatteryVoltageThe voltage of DG battery. Value range: 0 to 24, units: V, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-240 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.13 | ||||||||||||
| hwDGTotalRuntimeThe total running time of DG, Value range: 0 to 876000, units: h, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-8760000 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.14 | ||||||||||||
| hwDGAphasePowerFactorA phase power factor of DG, Value range: -1 to 1, units: , and the value is two decimal space (.01). | Integer32 Constraints: range: -100-100 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.15 | ||||||||||||
| hwDGBphasePowerFactorB phase power factor of DG, Value range: -1 to 1, units: , and the value is two decimal space (.01). | Integer32 Constraints: range: -100-100 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.16 | ||||||||||||
| hwDGCphasePowerFactorC phase power factor of DG, Value range: -1 to 1, units: , and the value is two decimal space (.01). | Integer32 Constraints: range: -100-100 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.17 | ||||||||||||
| hwDGLoadRateThe load rate of DG, Value range: 0 to 100, units: %, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.18 | ||||||||||||
| hwDGOnOffControlPower-on or power-off of the DG module, is an enumeration value. Users can modify the enumeration value of this node, thus controlling of the power-on or power-off of the DG module: If the NMS notifies the SNMP agent th… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.19 | ||||||||||||
| hwDGFaultResetDG fault reset. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.20 | ||||||||||||
| hwDGMaintenanceConfirmDG maintenance confirm. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.21 | ||||||||||||
| hwDGOperStatusState of the DG. It is an enumeration type: If the enumeration value is 1, it indicates that the DG is in the normal state; If the enumeration value is 2, it indicates that the DG is in the fault state; If the enumer… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.99 | ||||||||||||
| hwDGRowStatusRowStatus fo DG. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.12.2.1.1.100 |
hwSSUTable
table.1.3.6.1.4.1.2011.6.164.1.13.2.1
·
1 row entry
·
9 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSSUTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSSUTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwSSUIndexSSU table index,which value range:1 to 256. Lines of the device list are restricted by the quantity of SSU. | Integer32 Constraints: range: 0-256 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.1 | ||||||||||||
| hwSSUEquipIdSSU device ID. Value range: 024'001 to 024'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 24001-24255 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.2 | ||||||||||||
| hwSSUEquipNameDevice name of the SSU module, character string type, is used to specify the SSU module. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.3 | ||||||||||||
| hwSSURunningStateThe running status of the SSU module. It is an enumeration type: If the enumeration value is 1, it indicates that the SSU module is power on ; If the enumeration value is 2, it indicates that the SSU module is power of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.4 | ||||||||||||
| hwSSUInputVoltageThe input voltage of SSU, Value range: 0 to 200, units: V, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-2000 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.5 | ||||||||||||
| hwSSUOutputVoltageThe output voltage of SSU, Value range: 0 to 200, units: V, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-2000 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.6 | ||||||||||||
| hwSSUOutputCurrentThe output current of SSU, Value range: 0 to 1000, units: A, and the value is one decimal space (.1). | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.7 | ||||||||||||
| hwSSUAddressThe address of SSU, Value range: 0 to 100, units: , and the value is an integer (1). | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.8 | ||||||||||||
| hwSSURowStatusRowStatus fo SSU. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.13.2.1.1.100 |
.1.3.6.1.4.1.2011.6.164.1.14.2.1
·
1 row entry
·
19 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteBatteryCabinetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteBatteryCabinetTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwBatteryCabinetIndexBattery Cabinet table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of Battery Cabinet | Unsigned32 Constraints: range: 4096-20479 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.1 | ||||||||||||
| hwBatteryCabinetEquipIdBattery Cabinet device ID. Value range: 025'001 to 025'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 25000-25255 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.2 | ||||||||||||
| hwBatteryCabinetEquipNameBattery Cabinet name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.3 | ||||||||||||
| hwBatteryCabinetIndoorVentTempIndoor vent temperature. It is an environment parameter collected in real time. Value range: -40 to +100, units: centigrade, and the value is an integer (1). If the value is -99999, it indicates that the temperatur… | Integer32 Constraints: range: -40-100 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.4 | ||||||||||||
| hwBatteryCabinetBattTempBattery temperature. It is an environment parameter collected in real time. Value range: -40 to +100, units: centigrade, and the value is an integer (1). If the value is -99999, it indicates that the temperature sen… | Integer32 Constraints: range: -40-100 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.5 | ||||||||||||
| hwBatteryCabinetFan1SpeedFan 1 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.6 | ||||||||||||
| hwBatteryCabinetFan2SpeedFan 2 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.7 | ||||||||||||
| hwBatteryCabinetFan3SpeedFan 3 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.8 | ||||||||||||
| hwBatteryCabinetFan4SpeedFan 4 speed, Value range: 0.0 to 10000.0. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.9 | ||||||||||||
| hwBatteryCabinetAirConditionerStatusState of the airconditioner. It is an enumeration type: If the enumeration value is 1, it indicates that the airconditioner is in the standby state; If the enumeration value is 2, it indicates that the airconditioner i… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.10 | ||||||||||||
| hwBatteryCabinetCompressorStatusState of the compressor. It is an enumeration type: If the enumeration value is 1, it indicates that the compressor is in the standby state; If the enumeration value is 2, it indicates that the compressor is in the run… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.11 | ||||||||||||
| hwBatteryCabinetInternalFanSpeedInternal Fan speed, Value range: 0 to 10000. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the fan is not configured. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.12 | ||||||||||||
| hwBatteryCabinetExternalFanSpeedExternal Fan speed, Value range: 0 to 10000. Unit: rpm, the value is an integer (1). If the value is -1, it indicates that the temperature sensor is not configured. | Integer32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.13 | ||||||||||||
| hwBatteryCabinetAirConditionerRuntimeTotal runtime of the air conditioner. Value units: hour (h), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.14 | ||||||||||||
| hwBatteryCabinetCompressorRuntimeTotal runtime of the compressor. Value units: hour (h), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.15 | ||||||||||||
| hwBatteryCabinetAirConWorkTempBattery cabinet aircondition power on temperature point, Value range:-20 to 80 Unit: degC. and the value is an integer (1). | Integer32r/w Constraints: range: -20-80 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.16 | ||||||||||||
| hwBatteryCabinetAirConStopTempBattery cabinet aircondition power off temperature point, Value range:-20 to 80 Unit: degC. and the value is an integer(1). | Integer32r/w Constraints: range: -20-80 | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.17 | ||||||||||||
| hwBatteryCabinetOperStatusState of the Battery Cabinet. It is an enumeration type: If the enumeration value is 1, it indicates that the Inverter is in the normal state; If the enumeration value is 2, it indicates that the Inverter is in the fau… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.99 | ||||||||||||
| hwBatteryCabinetRowStatusRowStatus fo Battery Cabinet table. | RowStatusr/w Type Values:
Description: Description. | .1.3.6.1.4.1.2011.6.164.1.14.2.1.1.100 |
hwEsduTable
table.1.3.6.1.4.1.2011.6.164.1.15.2
·
1 row entry
·
38 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwEsduTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwEsduTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwEsduIndexESDU equip index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of Battery Cabinet | Unsigned32 Constraints: range: 3428-3443 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.1 | ||||||||||||||
| hwEsduEquipIdEsdu device ID. Value range: 028,001 to 028,255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 28001-28255 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.2 | ||||||||||||||
| hwEsduEquipName/ | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.3 | ||||||||||||||
| hwEsduSetDigitalInput1AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.4 | ||||||||||||||
| hwEsduDigitalInput1OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.5 | ||||||||||||||
| hwEsduSetDigitalInput2AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.6 | ||||||||||||||
| hwEsduDigitalInput2OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.7 | ||||||||||||||
| hwEsduSetDigitalInput3AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.8 | ||||||||||||||
| hwEsduDigitalInput3OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.9 | ||||||||||||||
| hwEsduSetDigitalInput4AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.10 | ||||||||||||||
| hwEsduDigitalInput4OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.11 | ||||||||||||||
| hwEsduSetDigitalInput5AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.12 | ||||||||||||||
| hwEsduDigitalInput5OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.13 | ||||||||||||||
| hwEsduSetDigitalInput6AlarmConditionSpare digital alarm state. It is an enumeration value.If the value of the node is 1, it indicates a high-tension alarm;If the value of the node is 2, it indicates a low-tension alarm;If the value of the node is 255, it … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.14 | ||||||||||||||
| hwEsduDigitalInput6OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.15 | ||||||||||||||
| hwEsduSetDigitalInput7AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.16 | ||||||||||||||
| hwEsduDigitalInput7OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.17 | ||||||||||||||
| hwEsduSetDigitalInput8AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.18 | ||||||||||||||
| hwEsduDigitalInput8OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.19 | ||||||||||||||
| hwEsduSetDigitalInput9AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.20 | ||||||||||||||
| hwEsduDigitalInput9OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.21 | ||||||||||||||
| hwEsduSetDigitalInput10AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.22 | ||||||||||||||
| hwEsduDigitalInput10OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.23 | ||||||||||||||
| hwEsduSetDigitalInput11AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.24 | ||||||||||||||
| hwEsduDigitalInput11OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.25 | ||||||||||||||
| hwEsduSetDigitalInput12AlarmConditionSpare digital alarm state. It is an enumeration value. If the value of the node is 1, it indicates a high-tension alarm; If the value of the node is 2, it indicates a low-tension alarm; If the value of the node is 255, … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.26 | ||||||||||||||
| hwEsduDigitalInput12OperStatusIt indicates the digital input operation status. It is an enumeration value. If the value of the node is 1, it indicates that the diesel of state is normal; If the value of the node is 2, it indicates that the diesel of… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.27 | ||||||||||||||
| hwEsduBtempValueTemp1. It is an environment parameter collected in real time. Value range: -40 to +80, Unit: degC and the value is an integer (1). If the value is -1024, it indicates that the temperature sensor is not configured. | Integer32 Constraints: range: -40-80 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.28 | ||||||||||||||
| hwEsduBtempOperStatusState of the site temp1 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp1 sensor is in the normal state; If the enumeration value is 2, it indicates that the temp1 sens… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.31 | ||||||||||||||
| hwEsduTemp1ValueTemp1. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value is -1024, it indicates that the temperature sensor is n… | Integer32 Constraints: range: -40-80 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.32 | ||||||||||||||
| hwEsduTemp1HighLimitUpper threshold of the temp1 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | Integer32r/w Constraints: range: 25-80 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.33 | ||||||||||||||
| hwEsduTemp1LowLimitLower threshold of the temp1 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: -20-20 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.34 | ||||||||||||||
| hwEsduTemp1OperStatusState of the site temp1 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp1 sensor is in the normal state; If the enumeration value is 2, it indicates that the temp1 sens… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.35 | ||||||||||||||
| hwEsduTemp2ValueTemp2. It is an environment parameter collected in real time. Value range: -40 to +80, units: centigrade (degC), and the value is an integer (1). If the value is -1024, it indicates that the temperature sensor is n… | Integer32 Constraints: range: -40-80 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.36 | ||||||||||||||
| hwEsduTemp2HighLimitUpper threshold of the temp2 alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value … | Integer32r/w Constraints: range: 25-80 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.37 | ||||||||||||||
| hwEsduTemp2LowLimitLower threshold of the temp2 alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: -20-20 | .1.3.6.1.4.1.2011.6.164.1.15.2.1.38 | ||||||||||||||
| hwEsduTemp2OperStatusState of the site temp2 sensor. It is an enumeration type: If the enumeration value is 1, it indicates that the site temp2 sensor is in the normal state; If the enumeration value is 2, it indicates that the temp2 sens… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.39 | ||||||||||||||
| hwEsduDoorSensorConnectDoor Sensor Connected; It is an enumeration value, and can be configured. If the enumeration value is 1, it indicates Door Sensor is disable; If the enumeration value is 2, it indicates Door Sensor is enalble; If the e… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.15.2.1.40 |
hwAcbGroupSampTable
table.1.3.6.1.4.1.2011.6.164.1.17.1
·
1 row entry
·
13 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcbGroupSampTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcbGroupSampTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwAcbGroupIndexThe battery group equip Index. | Unsigned32 Constraints: range: 0-256 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.1 | ||||||||||||||||
| hwAcbGroupEquipIdThe battery group equip ID no. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.2 | ||||||||||||||||
| hwAcbGroupEquipNameThe battery group equip name. | OctetString | .1.3.6.1.4.1.2011.6.164.1.17.1.1.3 | ||||||||||||||||
| hwAcbGroupBatRunningStateState of the Battery group unit running state. It is an enumeration type: If the enumeration value is 1, it indicates the Battery is first on line, If the enumeration value is 2, it indicates that Battery power off, If … | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.17.1.1.4 | ||||||||||||||||
| hwAcbGroupBatVoltThe battery volt; Value range: 0 to 100, units: V. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.5 | ||||||||||||||||
| hwAcbGroupBatCurrThe battery current; Value range: -4000 to 4000, units: A. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -40000-40000 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.6 | ||||||||||||||||
| hwAcbGroupTotalCapacityThe battery total capacity; Value range: 0 to 10000, units: Ah. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.7 | ||||||||||||||||
| hwAcbGroupTotalRemainCapacityThe battery total remain capacity; Value range:0 to 100, units: %. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.8 | ||||||||||||||||
| hwAcbGroupTemperatureThe battery temperature; Value range:-50 to 100, units: degC. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Integer32 Constraints: range: -500-1000 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.9 | ||||||||||||||||
| hwAcbGroupBackupTimeThe battery backup time; Value range: 0 to 256, units: h. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-2560 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.11 | ||||||||||||||||
| hwAcbGroupEsmuCommNumThe esmu communicate number, Value range: 0 to 100. If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.12 | ||||||||||||||||
| hwAcbGroupBatSohThe battery soh: 0 to 100, units: %. and the value is accurate to one decimal place (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.13 | ||||||||||||||||
| hwAcbGroupTotalDischargeDepthThe battery total discharge depth, units: %. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 10-1000 | .1.3.6.1.4.1.2011.6.164.1.17.1.1.22 |
hwAcbGroupSetTable
table.1.3.6.1.4.1.2011.6.164.1.17.2
·
1 row entry
·
10 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcbGroupSetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcbGroupSetTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwAcbGroupCellNumBattery cell number. Value range: 1 to 32, If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 1-32 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.5 |
| hwAcbGroupSetTotalCapacityThe battery total capacity, units: wh. and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-10000 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.6 |
| hwAcbGroupEqualVoltBattery equalcharge voltage, can be configued by users. Value range: 42 to 58, units: v, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is inval… | Unsigned32r/w Constraints: range: 420-580 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.11 |
| hwAcbGroupFloatVoltBattery floatcharge voltage, can be configued by users. Value range: 42 to 58, units: v, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invali… | Unsigned32r/w Constraints: range: 420-580 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.12 |
| hwAcbGroupChargeCurrLimitThrBattery charge limited threhold , can be configued by users. Value range: 0.05 to 2, units: C10, and the value is accurate to two decimal space (.01). If the setting value is beyond the current support range, it will fa… | Unsigned32r/w Constraints: range: 5-200 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.13 |
| hwAcbGroupOverCurThrBattery over charge current limited threhold , can be configued by users. Value range: 0.15 to 1.2, units: C10, and the value is accurate to two decimal space (.01). If the value is 2147483647(0x7FFFFFFF), it indicates … | Unsigned32r/w Constraints: range: 15-120 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.14 |
| hwAcbGroupHighTempThrUpper threshold of the environment temperature alarm, can be configured by users. Value range: 35 to 70, units: centigrade (??C), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates tha… | Unsigned32r/w Constraints: range: 35-70 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.21 |
| hwAcbGroupLowTempThrLower threshold of the environment temperature alarm, can be configured by users. Value range: -50 to 0, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates th… | Integer32r/w Constraints: range: -50-0 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.22 |
| hwAcbGroupDodToAcidBatteryThe lithium battery discharge depth for Acid Battery running; ,units: %. | Unsigned32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.26 |
| hwAcbGroupDefaultChargeCurrLimitThrBattery default charge limited threhold , can be configued by users. Value range: 0.05 to 2, units: C10, and the value is accurate to two decimal space (.01). If the setting value is beyond the current support rang… | Unsigned32r/w Constraints: range: 5-200 | .1.3.6.1.4.1.2011.6.164.1.17.2.1.27 |
hwAcbBaseTable
table.1.3.6.1.4.1.2011.6.164.1.18.1
·
1 row entry
·
5 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcbBaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcbBaseTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwAcbIndexThe battery equip Index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.18.1.1.1 |
| hwAcbEquipIdThe battery equip ID no. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.18.1.1.2 |
| hwAcbEquipNameThe battery equip name. | OctetStringr/w | .1.3.6.1.4.1.2011.6.164.1.18.1.1.3 |
| hwAcbEquipAddrThe battery communica address. | Unsigned32 Constraints: range: 0-255 | .1.3.6.1.4.1.2011.6.164.1.18.1.1.4 |
| hwAcbSoftVarThe Battery software version. | OctetString | .1.3.6.1.4.1.2011.6.164.1.18.1.1.5 |
hwAcbSampTable
table.1.3.6.1.4.1.2011.6.164.1.18.2
·
1 row entry
·
49 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcbSampTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcbSampTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| hwAcbBatVoltvoltage of the battery. It indicates the real-time statistics of the battery on the site. Value range: 0 to 60, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it in… | Unsigned32 Constraints: range: 0-600 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.1 | ||||||||||||||||
| hwAcbBatCurrCurrent of the battery. It indicates the real-time statistics of the battery on the site. Value range: -200 to 200, unit: A, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Integer32 Constraints: range: -2000-2000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.2 | ||||||||||||||||
| hwAcbRunningStatusBattery charging state, indicates the charging and discharging information about the battery group. It is an enumeration type. If the enumeration value is 1, it indicates a battery in the Offline state. If the enumerat… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.18.2.1.3 | ||||||||||||||||
| hwAcbBatSohSoh of the battery. It indicates the real-time statistics of the battery on the site. Value range: 0 to 100, unit: %, and the value is accurate to two decimal place (1). If the value is 2147483647(0x7FFFFFFF), it indica… | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.4 | ||||||||||||||||
| hwAcbBatCapacityCapacity of the battery. Value range: 0 to 10000, unit: Ah, and the value is accurate to two decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-100000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.5 | ||||||||||||||||
| hwAcbBatCell1VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.6 | ||||||||||||||||
| hwAcbBatCell2VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.7 | ||||||||||||||||
| hwAcbBatCell3VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.8 | ||||||||||||||||
| hwAcbBatCell4VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.9 | ||||||||||||||||
| hwAcbBatCell5VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.10 | ||||||||||||||||
| hwAcbBatCell6VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.11 | ||||||||||||||||
| hwAcbBatCell7VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.12 | ||||||||||||||||
| hwAcbBatCell8VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.13 | ||||||||||||||||
| hwAcbBatCell9VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.14 | ||||||||||||||||
| hwAcbBatCell10VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.15 | ||||||||||||||||
| hwAcbBatCell11VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.16 | ||||||||||||||||
| hwAcbBatCell12VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.17 | ||||||||||||||||
| hwAcbBatCell13VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.18 | ||||||||||||||||
| hwAcbBatCell14VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.19 | ||||||||||||||||
| hwAcbBatCell15VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.20 | ||||||||||||||||
| hwAcbBatCell16VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.21 | ||||||||||||||||
| hwAcbBatCell1TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.22 | ||||||||||||||||
| hwAcbBatCell2TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.23 | ||||||||||||||||
| hwAcbBatCell3TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.24 | ||||||||||||||||
| hwAcbBatCell4TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.25 | ||||||||||||||||
| hwAcbBatCell5TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.26 | ||||||||||||||||
| hwAcbBatCell6TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.27 | ||||||||||||||||
| hwAcbBatCell7TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.28 | ||||||||||||||||
| hwAcbBatCell8TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.29 | ||||||||||||||||
| hwAcbBatCell9TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.30 | ||||||||||||||||
| hwAcbBatCell10TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.31 | ||||||||||||||||
| hwAcbBatCell11TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.32 | ||||||||||||||||
| hwAcbBatCell12TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.33 | ||||||||||||||||
| hwAcbBatCell13TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.34 | ||||||||||||||||
| hwAcbBatCell14TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.35 | ||||||||||||||||
| hwAcbBatCell15TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.36 | ||||||||||||||||
| hwAcbBatCell16TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.37 | ||||||||||||||||
| hwAcbBatCell17TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.38 | ||||||||||||||||
| hwAcbBatCell18TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.39 | ||||||||||||||||
| hwAcbBatCell19TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.40 | ||||||||||||||||
| hwAcbBatCell20TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.41 | ||||||||||||||||
| hwAcbBatCell21TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.42 | ||||||||||||||||
| hwAcbBatCell22TempTemperature of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: -100 to 100, units: centigrade(degC), and the value is accurate to one decimal place (.1). If the value is … | Integer32 Constraints: range: -1000-1000 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.43 | ||||||||||||||||
| hwAcbBatCell17VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.44 | ||||||||||||||||
| hwAcbBatCell18VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.45 | ||||||||||||||||
| hwAcbBatCell19VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.46 | ||||||||||||||||
| hwAcbBatCell20VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.47 | ||||||||||||||||
| hwAcbBatCell21VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.48 | ||||||||||||||||
| hwAcbBatCell22VoltVoltage of the battery cell. It indicates the real-time statistics of the battery on the site. Value range: 0 to 5, unit: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), i… | Unsigned32 Constraints: range: 0-50 | .1.3.6.1.4.1.2011.6.164.1.18.2.1.49 |
hwAcbSetTable
table.1.3.6.1.4.1.2011.6.164.1.18.3
·
1 row entry
·
2 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAcbSetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAcbSetTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| hwAcbGyroEnableGyro Function Enable, Restricted use in special areas. If the value of the device is within the range, but the setting fails, the function is not supported. It is an enumeration value: If the enumeration value is 1, i… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.18.3.1.5 | ||||||||
| hwAcbGyroSensitivityLevelGyro Level of Sensitivity. Restricted use in special areas. If the value of the device is within the range, but the setting fails, the function is not supported. It is an enumeration value: If the enumeration value is 1… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.18.3.1.6 |
hwSiteIboxTable
table.1.3.6.1.4.1.2011.6.164.1.20.1
·
1 row entry
·
4 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteIboxTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteIboxTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwIboxIndexibox table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of ibox | Unsigned32 Constraints: range: 560-575 | .1.3.6.1.4.1.2011.6.164.1.20.1.1.1 |
| hwIboxEquipIdibox device ID. Value range: 029'001 to 029'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 29001-29255 | .1.3.6.1.4.1.2011.6.164.1.20.1.1.2 |
| hwIboxEquipNameIbox name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.20.1.1.3 |
| hwIbatEquipNumNumber of Batteries. Value range: 0 to 96, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32r/w Constraints: range: 0-96 | .1.3.6.1.4.1.2011.6.164.1.20.1.1.4 |
hwSiteIbatTable
table.1.3.6.1.4.1.2011.6.164.1.21.1
·
1 row entry
·
6 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteIbatTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteIbatTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwIbatIndexibox table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of ibox | Unsigned32 Constraints: range: 24576-26112 | .1.3.6.1.4.1.2011.6.164.1.21.1.1.1 |
| hwIbatEquipIdibat device ID. Value range: 030'001 to 031'537, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 30001-31537 | .1.3.6.1.4.1.2011.6.164.1.21.1.1.2 |
| hwIbatEquipNameIbat name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.21.1.1.3 |
| hwIbatTemperatureIbat temperature. It is a ibat parameter collected in real time. Value range: -50 to +125, unit: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that ibox tem… | Integer32 Constraints: range: -50-125 | .1.3.6.1.4.1.2011.6.164.1.21.1.1.4 |
| hwIbatVoltageIbat Voltage of the ibat. It is an inherent attribute. Value range: 0 to 100, Units: V, and the value is accurate to one decimal place (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is in… | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.21.1.1.5 |
| hwIbatResistanceIbatResistance Value range: 0 to 1000000, units: (mohm), and the value is accurate to two decimal place (.01). | Unsigned32 Constraints: range: 0-100000000 | .1.3.6.1.4.1.2011.6.164.1.21.1.1.6 |
hwSiteCommExBoardTable
table.1.3.6.1.4.1.2011.6.164.1.22.1
·
1 row entry
·
3 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteCommExBoardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteCommExBoardTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwCommExBoardIndexCommunication Expansion Board table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of Communication Expansion Board | Unsigned32 Constraints: range: 1297-1301 | .1.3.6.1.4.1.2011.6.164.1.22.1.1.1 |
| hwCommExBoardEquipIdCommunication Expansion Board device ID. Value range: 032,256 to 033,249, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 32266-33049 | .1.3.6.1.4.1.2011.6.164.1.22.1.1.2 |
| hwCommExBoardEquipNameCommunication Expansion Board name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.22.1.1.3 |
hwSiteDGCommExBoardTable
table.1.3.6.1.4.1.2011.6.164.1.23.1
·
1 row entry
·
3 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteDGCommExBoardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteDGCommExBoardTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwDGCommExBoardIndexDG Communication Expansion Board table index,which value is according to the actual subject. Lines of the device list are restricted by the quantity of DG Communication Expansion Board | Unsigned32 Constraints: range: 2185-2185 | .1.3.6.1.4.1.2011.6.164.1.23.1.1.1 |
| hwDGCommExBoardEquipIdDG Communication Expansion Board device ID. Value range: 034'001, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 34001-34001 | .1.3.6.1.4.1.2011.6.164.1.23.1.1.2 |
| hwDGCommExBoardEquipNameDG Communication Expansion Board name, of the character string type, is used to specify battery cabinet. Users can configure it. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.23.1.1.3 |
hwElockEquipTable
table.1.3.6.1.4.1.2011.6.164.1.27.1
·
1 row entry
·
3 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwElockEquipTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwElockEquipTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwElockEquipIndexThe elock equip Index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.27.1.1.1 |
| hwElockEquipIdThe elock equip ID no. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.27.1.1.2 |
| hwElockEquipNameThe elock equip name. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.27.1.1.3 |
hwTemHumEquipTable
table.1.3.6.1.4.1.2011.6.164.1.28.1
·
1 row entry
·
10 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwTemHumEquipTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwTemHumEquipTable'
/
/
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwTemHumEquipIndexThe tem_hum equip Index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.1 |
| hwTemHumEquipIdThe tem_hum equip ID no. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.2 |
| hwTemHumEquipNameThe tem_hum equip name. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.3 |
| hwTemHumEquipAmbientTempthe environment temperature. units: centigrade (degC), and the value is an integer (1). | Integer32 Constraints: range: -20-80 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.4 |
| hwTemHumEquipAmbientHumidityenvironment temperature , units: %RH, and the value is an integer (1). | Unsigned32 Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.5 |
| hwSetHumTempUpperLimitUpper threshold of the environment temperature alarm, can be configured by users. Value range: 25 to 80, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicate… | Integer32r/w Constraints: range: 25-80 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.6 |
| hwSetHumTempLowerLimitLower threshold of the environment temperature alarm, can be configured by users. Value range: -20 to 20, units: centigrade (degC), and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indica… | Integer32r/w Constraints: range: -20-20 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.7 |
| hwSetHumidityUpperLimitUpper threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.8 |
| hwSetHumidityLowerLimitLower threshold of the environment humility alarm, can be configured by users. Value range: 0 to 100, units: %RH, and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value… | Integer32r/w Constraints: range: 0-100 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.9 |
| hwTemHumEquipAddressDevice address And the value is an integer (1). | Unsigned32 Constraints: range: 0-255 | .1.3.6.1.4.1.2011.6.164.1.28.1.1.10 |
hwHeaterDeviceTable
table.1.3.6.1.4.1.2011.6.164.1.29.1
·
1 row entry
·
5 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwHeaterDeviceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwHeaterDeviceTable'
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwHeaterDeviceIndexheater device table index. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.29.1.1.1 |
| hwHeaterDeviceEquipIdheater device equipid. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.29.1.1.2 |
| hwHeaterDeviceEquipNameheater device equipname. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.2011.6.164.1.29.1.1.3 |
| hwHeaterStartTemperatureheater start temperature; Value range:-10 to 15.Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. note: hwHeaterStartTemperature's set value … | Integer32r/w Constraints: range: -10-15 | .1.3.6.1.4.1.2011.6.164.1.29.1.1.4 |
| hwHeaterStopTemperatureheater stop temperature; Value range: 5 to 20.Unit: degC. and the value is an integer (1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. note: hwHeaterStartTemperature's set value mus… | Integer32r/w Constraints: range: 5-20 | .1.3.6.1.4.1.2011.6.164.1.29.1.1.5 |
hwSiteDMUSampTable
table.1.3.6.1.4.1.2011.6.164.1.31.1
·
1 row entry
·
6 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteDMUSampTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteDMUSampTable'
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwDMUIndexDMU table index, which value range:1 to 256. Lines of the device list are restricted by the quantity of DMU. | Unsigned32 Constraints: range: 0-256 | .1.3.6.1.4.1.2011.6.164.1.31.1.1.1 |
| hwDMUEquipIdDMU device ID. Value range: 033'001 to 033'255, in which the first digits indicate the device type and the last three digits indicate the device SN. | Unsigned32 Constraints: range: 33001-33255 | .1.3.6.1.4.1.2011.6.164.1.31.1.1.2 |
| hwDMUEquipNameDevice name of the DMU module, character string type, is used to specify the DMU module. Otherwise, the configured character can not be any other languages except English. | OctetString Constraints: range: 0-56 | .1.3.6.1.4.1.2011.6.164.1.31.1.1.3 |
| hwDMUDCOutputVoltageDC output voltage: 0 to 100, units: V, and the value is one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-1000 | .1.3.6.1.4.1.2011.6.164.1.31.1.1.4 |
| hwDMULoadCurrentLoad current: 0 to 30000, units: A, and the value is one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-300000 | .1.3.6.1.4.1.2011.6.164.1.31.1.1.5 |
| hwDMUTotalLoadConsumptionTotal load consumption: 0 to 4294967295, units: kWh, and the value is one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicates that the value is invalid. | Unsigned32 Constraints: range: 0-4294967295 | .1.3.6.1.4.1.2011.6.164.1.31.1.1.6 |
hwSiteDMUSetTable
table.1.3.6.1.4.1.2011.6.164.1.31.2
·
1 row entry
·
12 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteDMUSetTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteDMUSetTable'
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| hwSiteDMULoad1LvdEnload1 lvd enable :It is an enumeration type: If the enumeration value is 1, it means to disable the lvd control; If the enumeration value is 2, it means to enable the lvd control | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.31.2.1.1 | ||||
| hwSiteDMULoad1LvdModeload1 lvd mode :It is an enumeration type: If the enumeration value is 1, it means the voltage mode; If the enumeration value is 2, it means the time mode | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.31.2.1.2 | ||||
| hwSiteDMULoad1LvdVoltageLow-voltage power-off voltage of the DMU unit can be configured by users. Its value range: 36 to 56, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicat… | Unsigned32r/w Constraints: range: 360-560 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.3 | ||||
| hwSiteDMULoad1LvdReconVoltageLow-voltage power-off recover of the DMU unit can be configured by users. Its value range: 37.0 to 58.0, unit: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indic… | Unsigned32r/w Constraints: range: 370-580 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.4 | ||||
| hwSiteDMULoad1LvdTimeLow-voltage power-off disconnected time, It can be configured by users, and its value is an integer (1). Here, if lvd mode is time mode, value range defines between 0 to 6000, unit: minutes(min). If the value is 2147… | Integer32r/w Constraints: range: 0-6000 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.5 | ||||
| hwSiteDMULoad1LvdCapacityPower-off unit control the power off, when Remaining capacity percentage of the battery strings is below the calue. Value range: 0 to 99, unit: %, and the value is accurate to one decimal place (.1). If the value is… | Integer32r/w Constraints: range: 0-99 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.6 | ||||
| hwSiteDMULoad2LvdEnload1 lvd enable :It is an enumeration type: If the enumeration value is 1, it means to disable the lvd control; If the enumeration value is 2, it means to enable the lvd control | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.31.2.1.7 | ||||
| hwSiteDMULoad2LvdModeload1 lvd mode :It is an enumeration type: If the enumeration value is 1, it means the voltage mode; If the enumeration value is 2, it means the time mode | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.1.31.2.1.8 | ||||
| hwSiteDMULoad2LvdVoltageLow-voltage power-off voltage of the DMU unit can be configured by users. Its value range: 36 to 56, units: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indicat… | Unsigned32r/w Constraints: range: 360-560 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.9 | ||||
| hwSiteDMULoad2LvdReconVoltageLow-voltage power-off recover of the DMU unit can be configured by users. Its value range: 37.0 to 58.0, unit: V, and the value is accurate to one decimal space (.1). If the value is 2147483647(0x7FFFFFFF), it indic… | Unsigned32r/w Constraints: range: 370-580 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.10 | ||||
| hwSiteDMULoad2LvdTimeLow-voltage power-off disconnected time, It can be configured by users, and its value is an integer (1). Here, if lvd mode is time mode, value range defines between 0 to 6000, unit: minutes(min). If the value is 2147… | Integer32r/w Constraints: range: 0-6000 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.11 | ||||
| hwSiteDMULoad2LvdCapacityPower-off unit control the power off, when Remaining capacity percentage of the battery strings is below the calue. Value range: 0 to 99, unit: %, and the value is accurate to one decimal place (.1). If the value is … | Integer32r/w Constraints: range: 0-99 | .1.3.6.1.4.1.2011.6.164.1.31.2.1.12 |
hwAtsSampTable
table.1.3.6.1.4.1.2011.6.164.1.33.1
·
1 row entry
·
3 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwAtsSampTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwAtsSampTable'
Indexes
| Column | Syntax | OID |
|---|---|---|
| hwAtsIndexTable index of the running ATS modules | Unsigned32 Constraints: range: 0-256 | .1.3.6.1.4.1.2011.6.164.1.33.1.1.1 |
| hwAtsEquipIdATS module ID. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.2011.6.164.1.33.1.1.2 |
| hwAtsEquipNameDevice name of the ATS module | OctetString Constraints: range: 0-56 | .1.3.6.1.4.1.2011.6.164.1.33.1.1.3 |
hwSiteCameraTable
table.1.3.6.1.4.1.2011.6.164.3.1
·
1 row entry
·
14 columns
Uses the huawei variant from
Command help
/opt/observium/mibs/huawei.
Walk hwSiteCameraTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EMAP-MIB' -M '/opt/observium/mibs/huawei:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EMAP-MIB::hwSiteCameraTable'
/
/
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| hwSiteCameraIpthe camera ip adress. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.1 | ||||||||
| hwSiteCameraPortcamera connect port number. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.3.1.1.2 | ||||||||
| hwSiteCameraPhotSetAlarmTypeYou can set the alarm type to obtain the historical picture of the camera-related alarm shooting. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.2011.6.164.3.1.1.5 | ||||||||
| hwSiteCameraAssociatedAlarmPicture1Associated alarm picture 1. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.6 | ||||||||
| hwSiteCameraAssociatedAlarmPicture2Associated alarm picture 2. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.7 | ||||||||
| hwSiteCameraAssociatedAlarmPicture3Associated alarm picture 3. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.8 | ||||||||
| hwSiteCameraAssociatedAlarmPicture4Associated alarm picture 4. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.9 | ||||||||
| hwSiteCameraAssociatedAlarmPicture5Associated alarm picture 5. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.10 | ||||||||
| hwSiteCameraAssociatedAlarmPicture6Associated alarm picture 6. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.11 | ||||||||
| hwSiteCameraAssociatedAlarmPicture7Associated alarm picture 7. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.12 | ||||||||
| hwSiteCameraAssociatedAlarmPicture8Associated alarm picture 8. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.13 | ||||||||
| hwSiteCameraAssociatedAlarmPicture9Associated alarm picture 9. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.14 | ||||||||
| hwSiteCameraAssociatedAlarmPicture10Associated alarm picture 10. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.15 | ||||||||
| hwSiteCameraAdditionalAssociatedAlarmPicturesAdditional associated alarm pictures. | OctetString | .1.3.6.1.4.1.2011.6.164.3.1.1.16 |