ELTEX-SMI

        The Structure of Management Information for Eltex Networks.
    
Source file
ELTEX-SMI
Last revised
Identity
eltex
Base OID
1.3.6.1.4.1.34300
Imported Objects
SNMPv2-CONF NOTIFICATION-GROUP (no object page) OBJECT-GROUP (no object page)
SNMPv2-SMI enterprises Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-IDENTITY (no object page) OBJECT-TYPE (no object page)
SNMPv2-TC DisplayString TimeStamp
Net-SNMP examples using the eltex MIB directory Show commands

These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.

Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'ELTEX-SMI' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ELTEX-SMI::eltex'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-SMI' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-SMI::eltex'
How SNMP, Net-SNMP, MIB paths, and variants work
Objects (24)
.1.3.6.1.4.1.34300
.1.3.6.1.4.1.34300.1
.1.3.6.1.4.1.34300.2
.1.3.6.1.4.1.34300.3
.1.3.6.1.4.1.34300.3.10
.1.3.6.1.4.1.34300.3.10.1
.1.3.6.1.4.1.34300.3.10.2
.1.3.6.1.4.1.34300.3.10.3
.1.3.6.1.4.1.34300.3.20
.1.3.6.1.4.1.34300.3.21
.1.3.6.1.4.1.34300.3.3
.1.3.6.1.4.1.34300.3.4
.1.3.6.1.4.1.34300.3.5
.1.3.6.1.4.1.34300.3.5.1
.1.3.6.1.4.1.34300.3.5.2
.1.3.6.1.4.1.34300.3.5.3
.1.3.6.1.4.1.34300.3.5.4
.1.3.6.1.4.1.34300.3.5.5
OctetString
.1.3.6.1.4.1.34300.3.5.6
.1.3.6.1.4.1.34300.3.5.7
.1.3.6.1.4.1.34300.3.5.8
.1.3.6.1.4.1.34300.3.5.9
.1.3.6.1.4.1.34300.3.8
.1.3.6.1.4.1.34300.3.9
Dependencies (3) 3 direct Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. SNMPv2-SMIrfc
  2. SNMPv2-CONFrfc
  3. SNMPv2-TCrfc
  4. ELTEX-SMIeltexselected
Conformance Groups (2)
.1.3.6.1.4.1.34300.3.100
.1.3.6.1.4.1.34300.3.101
Notifications / Traps (74)
NameOIDDescription
.1.3.6.1.4.1.34300.3.20.1
mcTrapLParam1 = command <upload=1, download=2, apply=3, confirm=4, save=5>;
mcTrapLParam2 = filetype <pattern=1, private=2, binary=3>
mcTrapDescr = Description of operarion:
DeviceName,
command <upload, download, apply, confirm, save>,
tftp host,
config filename,
status=Error,
cause of error
.1.3.6.1.4.1.34300.3.21.1
mcTrapLParam1 = command <upload=1, download=2, apply=3, confirm=4, save=5>;
mcTrapLParam2 = filetype <pattern=1, private=2, binary=3>
mcTrapDescr = Description of operarion:
DeviceName,
command <upload, download, apply, confirm, save>,
tftp host,
config filename,
status=Ok
.1.3.6.1.4.1.34300.3.3.1
mc-240 stream alarm trap. Severity: alert
.1.3.6.1.4.1.34300.3.3.10
mc240 sensor alarm trap (mcTrapExState = sensors bit mask, param1=temp,C, param2=Hum,%)
.1.3.6.1.4.1.34300.3.3.11
dslam link down trap (mcTrapExState = link state, param1 = ADSLport)
.1.3.6.1.4.1.34300.3.3.12
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)
.1.3.6.1.4.1.34300.3.3.13
Downstream rate for dslam ADSL port change (mcTrapExState = 2-increase 1-decrease, param1 = ADSLport)
.1.3.6.1.4.1.34300.3.3.14
Bad registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')
.1.3.6.1.4.1.34300.3.3.15
Eth Link Down, mcTrapLParam1=Link Number, Description='GePON: Eth Link N down'
.1.3.6.1.4.1.34300.3.3.16
The optical link N (mcTrapLParam1) has no active devices
.1.3.6.1.4.1.34300.3.3.17
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)
.1.3.6.1.4.1.34300.3.3.18
when voltage deviation become more 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )
.1.3.6.1.4.1.34300.3.3.19
Trap sending when connection happen, mcTrapLParam1 - means connection from (0)-CLI (1)->Webs (2)->SNMP
.1.3.6.1.4.1.34300.3.3.2
mc-240 sync alarm trap. Severity: warning
.1.3.6.1.4.1.34300.3.3.20
Trap sending when switch port link DOWN, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1
.1.3.6.1.4.1.34300.3.3.3
mc-240 ss7 link alarm trap. Severity: alert
.1.3.6.1.4.1.34300.3.3.4
mc-240 ss7 linkset alarm trap. Severity: critical
.1.3.6.1.4.1.34300.3.3.5
mc-240 file alarm trap. Severity: critical
.1.3.6.1.4.1.34300.3.3.6
mc-240 card alarm trap. Severity: critical
.1.3.6.1.4.1.34300.3.3.7
mxl DSL DP system alarm trap
.1.3.6.1.4.1.34300.3.3.8
mxl DSL DP system alarm trap
.1.3.6.1.4.1.34300.3.3.9
mc240 UPS alarm trap
.1.3.6.1.4.1.34300.3.4.1
mc-240 stream ok trap. Severity: alert
.1.3.6.1.4.1.34300.3.4.10
mc240 sensor alarm trap (normal state)
.1.3.6.1.4.1.34300.3.4.11
dslam link up trap (mcTrapExState = link state == 0, param1 = ADSLport)
.1.3.6.1.4.1.34300.3.4.12
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)
.1.3.6.1.4.1.34300.3.4.13
Downstream rate for dslam ADSL port change (mcTrapExState = 0-reate not change, param1 = ADSLport)
.1.3.6.1.4.1.34300.3.4.14
Normal registration ONU Event (mcTrapLParam1=Optical Interface Number, mcTrapDescr='description with MAC addr ONU')
.1.3.6.1.4.1.34300.3.4.15
Eth Link Up, mcTrapLParam1=Link Number, Description='GePON: Eth Link N up'
.1.3.6.1.4.1.34300.3.4.16
The optical link N (mcTrapLParam1) has M (mcTrapLParam2) active devices
.1.3.6.1.4.1.34300.3.4.17
overheat (mcTrapExState = 1 -> DSP, = 2 -> PWR, param1 = val of temp * 10)
.1.3.6.1.4.1.34300.3.4.18
when voltage deviation become less 10% (param1 = number of voltage nominal mean 12, -12, 3.3, 2.5, 1.8, 1.25, 1.5, 1 correspondly, param2 - whole number part temperature value, param3 - decimal part temperature value )
.1.3.6.1.4.1.34300.3.4.19
Trap sending when connection closed, mcTrapLParam1 - means disconnection from (0)-CLI (1)->Webs (2)->SNMP
.1.3.6.1.4.1.34300.3.4.2
mc-240 sync ok trap. Severity: warning
.1.3.6.1.4.1.34300.3.4.20
Trap sending when switch port link UP, mcTrapLParam1 - means port num:
for mxa: 0 - p0; 1 - p1; 2 - p2; 3 - cpu; 4 - dsl0; 5 - sfp; 6 - dsl1;
for asl: 0 - lan; 3 - cpu; 4 - dsl0; 5 - dsl1; 6 - s0; 7 - s1
.1.3.6.1.4.1.34300.3.4.3
mc-240 ss7 link ok trap. Severity: alert
.1.3.6.1.4.1.34300.3.4.4
mc-240 ss7 linkset ok trap. Severity: critical
.1.3.6.1.4.1.34300.3.4.5
mc-240 file ok trap. Severity: critical
.1.3.6.1.4.1.34300.3.4.6
mc-240 card trap. Severity: critical
.1.3.6.1.4.1.34300.3.4.7
mxl DSL DP system alarm trap (normal state)
.1.3.6.1.4.1.34300.3.4.8
mxl DSL DP system alarm trap (normal state)
.1.3.6.1.4.1.34300.3.4.9
mc240 UPS alarm trap (normal state)
.1.3.6.1.4.1.34300.3.8.1
MP operation error.
.1.3.6.1.4.1.34300.3.8.10
Battery cell voltage spread is out of range.
.1.3.6.1.4.1.34300.3.8.11
AC voltage is out of range.
.1.3.6.1.4.1.34300.3.8.12
Battery is close to total discharge.
.1.3.6.1.4.1.34300.3.8.13
Load current is out of range.
.1.3.6.1.4.1.34300.3.8.14
Battery charge current is too high.
.1.3.6.1.4.1.34300.3.8.15
Power supply from battery.
.1.3.6.1.4.1.34300.3.8.16
Battery is disconnected from MPs' output.
.1.3.6.1.4.1.34300.3.8.2
Incorrect input parameters.
.1.3.6.1.4.1.34300.3.8.3
UEP configuration error.
.1.3.6.1.4.1.34300.3.8.4
Temperature measurement error.
.1.3.6.1.4.1.34300.3.8.5
ACV measurement error.
.1.3.6.1.4.1.34300.3.8.6
Battery current measurement error.
.1.3.6.1.4.1.34300.3.8.7
Battery voltage measurement error.
.1.3.6.1.4.1.34300.3.8.8
Can't change (increase or decrease) battery voltage.
.1.3.6.1.4.1.34300.3.8.9
Release device is off (battery disconnected).
.1.3.6.1.4.1.34300.3.9.1
MP operation OK.
.1.3.6.1.4.1.34300.3.9.10
Battery cell voltage spread is in range.
.1.3.6.1.4.1.34300.3.9.11
AC voltage is in range.
.1.3.6.1.4.1.34300.3.9.12
Battery charge status is OK.
.1.3.6.1.4.1.34300.3.9.13
Load current is in range.
.1.3.6.1.4.1.34300.3.9.14
Battery charge current is in range.
.1.3.6.1.4.1.34300.3.9.15
Power supply from MPs.
.1.3.6.1.4.1.34300.3.9.16
Battery is connected to MPs' output.
.1.3.6.1.4.1.34300.3.9.2
Input parameters OK.
.1.3.6.1.4.1.34300.3.9.3
UEP configuration OK.
.1.3.6.1.4.1.34300.3.9.4
Temperature measurement OK.
.1.3.6.1.4.1.34300.3.9.5
ACV measurement OK.
.1.3.6.1.4.1.34300.3.9.6
Battery current measurement OK.
.1.3.6.1.4.1.34300.3.9.7
Battery voltage measurement OK.
.1.3.6.1.4.1.34300.3.9.8
Battery voltage changing OK.
.1.3.6.1.4.1.34300.3.9.9
Release device is on.