.1.3.6.1.4.1.35265.1.139.11.1.1.1
·
1 row entry
·
2 columns
Uses the eltex variant from
Command help
/opt/observium/mibs/eltex.
Walk eltMesIssPoeGlobalConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-ISS-POE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-ISS-POE-MIB::eltMesIssPoeGlobalConfigTable'
A table of objects that control attributes of the PoE PSE group.
An entry in the eltMesIssPoeGlobalConfigTable.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| eltMesIssPoeGlobalConfigGroupIndexThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. | Integer32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.1.1.1.1 | ||||
| eltMesIssPoeInrushTestThis object controls PoE Inrush Test status. If PoE Inrush Test is ENABLED, then at the initialization of the connection, less power is supplied to prevent damaging the connected device | EltMesIssPoeInrushTestStatusr/w Type Values:
| .1.3.6.1.4.1.35265.1.139.11.1.1.1.1.2 |
eltMesIssPoeStatTable
table.1.3.6.1.4.1.35265.1.139.11.1.2.1
·
1 row entry
·
2 columns
Uses the eltex variant from
Command help
/opt/observium/mibs/eltex.
Walk eltMesIssPoeStatTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-ISS-POE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-ISS-POE-MIB::eltMesIssPoeStatTable'
The table listing Temperature information for PoE PSE group.
An entry in the eltMEsIssPoeStatTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
| eltMesIssPoeStatGroupIndexThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. | Integer32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.2.1.1.1 |
| eltMesIssPoeTemperatureThis object displays current temperature of the PoE controller. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.2.1.1.2 |
.1.3.6.1.4.1.35265.1.139.11.1.3.1
·
1 row entry
·
3 columns
Uses the eltex variant from
Command help
/opt/observium/mibs/eltex.
Walk eltMesIssPoePortConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-ISS-POE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-ISS-POE-MIB::eltMesIssPoePortConfigTable'
A table of objects that control attributes for Power Over Ethernet port.
An entry in the eltMesIssPoePortConfigTable.
| Column | Syntax | OID |
|---|---|---|
| eltMesIssPoePortConfigGroupIndexThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. | Integer32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.3.1.1.1 |
| eltMesIssPoePortConfigIfIndexThis variable uniquely identifies the PoE PSE port within group eltMesIssPoePortUtilGroupIndex to which PoE PSE entry is connected. | Integer32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.3.1.1.2 |
| eltMesIssPoePortMaxPowerLimitThis variable indicates on the user configured power level in milli watts which is available from eltMesIssPoePortConfigIfIndex. The special value of zero is used to set power level threshold according to… | Integer32r/w Constraints: range: 0-31200 | .1.3.6.1.4.1.35265.1.139.11.1.3.1.1.3 |
.1.3.6.1.4.1.35265.1.139.11.1.4.1
·
1 row entry
·
6 columns
Uses the eltex variant from
Command help
/opt/observium/mibs/eltex.
Walk eltMesIssPoePortUtilTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'ELTEX-MES-ISS-POE-MIB' -M '/opt/observium/mibs/eltex:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELTEX-MES-ISS-POE-MIB::eltMesIssPoePortUtilTable'
The table listing Current, Voltage and Power consumption information for Power Over Ethernet port.
An entry in the eltMesIssPoePortUtilTable.
| Column | Syntax | OID |
|---|---|---|
| eltMesIssPoePortUtilGroupIndexThis variable uniquely identifies the group containing the port to which a power Ethernet PSE is connected. Group means box in the stack, module in a rack and the value 1 MUST be used for non-modular devices. | Integer32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.4.1.1.1 |
| eltMesIssPoePortUtilIfIndexThis variable uniquely identifies the PoE PSE port within group eltMesIssPoePortUtilGroupIndex to which PoE PSE entry is connected. | Integer32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.4.1.1.2 |
| eltMesIssPoePortUtilOutputVoltageThis variable indicates on the output voltage level in volts. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.4.1.1.3 |
| eltMesIssPoePortUtilOutputCurrentThis variable indicates on the output current level in milliamps. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.4.1.1.4 |
| eltMesIssPoePortUtilOutputPowerThis variable indicates on the output power level in milliwatts. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.4.1.1.5 |
| eltMesIssPoePortUtilMaxPowerThis variable indicates on the max power in milliwatts that can be provided. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.35265.1.139.11.1.4.1.1.6 |