EKINOPS-Pmops2d-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
15
Rows
15
Columns
43
.1.3.6.1.4.1.20044.71.2.2.2.24
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dAlmclientComAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dAlmclientComAlarmTable'
List of pmops2dAlmclientComAlarm Article
Row definition for the pmops2dAlmclientComAlarm
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| pmops2dAlmclientComAlarmIndexIndex definition for the pmops2dAlmclientComAlarm table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.2.2.2.24.1.1 | ||||
| pmops2dAlmClientComSwitchFailPortnSwitch Fail :This OID indicates the OPS A switch component in in fail condition <Help> This alarm indicates if the OPS switch is in fail condition <Condtype> CLIENT_COM_SWITCH_FAIL <Probcause> equipmentMalfunctio… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.2.2.24.1.9 |
.1.3.6.1.4.1.20044.71.2.2.3.8
·
1 row entry
·
3 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dAlmsynthClientAlmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dAlmsynthClientAlmTable'
List of pmops2dAlmsynthClientAlm Article
Row definition for the pmops2dAlmsynthClientAlm
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| pmops2dAlmsynthClientAlmIndexIndex definition for the pmops2dAlmsynthClientAlm table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.2.2.3.8.1.1 | ||||
| pmops2dAlmClientHwFailAccPortnHW_Fail_Acc :This OID indicates a client hardware failure on the OPS <Help> This alarm indicates if a client HW fail access Alarm has been detected on the OPS <Condtype> CLIENT_HW_FAIL_ACC <Probcause> equipmentM… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.2.3.8.1.5 | ||||
| pmops2dAlmClientFailAccPortnClient_Acc_Fail :This OID indicates a client failure on the OPS <Help> This alarm indicates if a client fail access Alarm has been detected on the OPS <Condtype> CLIENT_FAIL_ACC <Probcause> equipmentMalfunction … | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.2.3.8.1.13 |
.1.3.6.1.4.1.20044.71.2.3.1.48
·
1 row entry
·
5 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dAlmlineMeasWngTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dAlmlineMeasWngTable'
List of pmops2dAlmlineMeasWng Article
Row definition for the pmops2dAlmlineMeasWng
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| pmops2dAlmlineMeasWngIndexIndex definition for the pmops2dAlmlineMeasWng table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.2.3.1.48.1.1 | ||||
| pmops2dAlmLineTxPwrLowWngPortnTx Low Warning :This OID indicates that Transmit power or the OPS is lower than the warning threshold of the OPS <Help> This warning indicates if the receive power on the transmit side of the OPS is too low <Con… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.1.48.1.2 | ||||
| pmops2dAlmLineTxPwrHighWngPortnTx High Warning : This OID indicates that Transmit power or the OPS is higher than the warning threshold of the OPS <Help> This warning indicates if the receive power on the transmit side of the OPS is too high … | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.1.48.1.3 | ||||
| pmops2dAlmLineRxPwrLowWngPortnRx Low Warning :This OID indicates that Receive power or the OPS is lower than the warning threshold of the OPS <Help> This warning indicates if the receive power on the receive side of the OPS is too low <Condt… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.1.48.1.4 | ||||
| pmops2dAlmLineRxPwrHighWngPortnRx High Warning : This OID indicates that Receive power or the OPS is higher than the warning threshold of the OPS <Help> This warning indicates if the receive power on the receive side of the OPS is too high <C… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.1.48.1.5 |
pmops2dAlmlineAlarmTable
table.1.3.6.1.4.1.20044.71.2.3.2.32
·
1 row entry
·
5 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dAlmlineAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dAlmlineAlarmTable'
List of pmops2dAlmlineAlarm Article
Row definition for the pmops2dAlmlineAlarm
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| pmops2dAlmlineAlarmIndexIndex definition for the pmops2dAlmlineAlarm table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.2.3.2.32.1.1 | ||||
| pmops2dAlmLosRxPortnRX Loss Of Signal :This OID indicates that a LOS is detected on the Receive 1 of the OPS <Help> This alarm indicates if an optical signal is detected on the RX of the OPS <Condtype> LOS_RX <Probcause> receiveFa… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.32.1.2 | ||||
| pmops2dAlmLosTxPortnTX Loss Of Signal :This OID indicates that a LOS is detected on the Transmit of the OPS <Help> This alarm indicates if an optical signal is detected on the TX of the OPS <Condtype> LOS_TX <Probcause> transmitFail… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.32.1.4 | ||||
| pmops2dAlmSwitchPositionOnePortnRX1 Selected :This OID indicates the OPS selects the RX 1 input <Help> This status indicates if the RX 1 input is selected on the OPS <Condtype> SWITCH_POSITION_ONE <Probcause> other (1) <Alarmtype> other (1) <P… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.32.1.6 | ||||
| pmops2dAlmSwitchPositionTwoPortnRX2 Selected :This OID indicates the OPS selects the RX 2 input <Help> This status indicates if the RX2 input is selected on the OPS <Condtype> SWITCH_POSITION_TWO <Probcause> other (1) <Alarmtype> other (1) <Po… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.32.1.7 |
.1.3.6.1.4.1.20044.71.2.3.2.40
·
1 row entry
·
5 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dAlmlineMeasAlaTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dAlmlineMeasAlaTable'
List of pmops2dAlmlineMeasAla Article
Row definition for the pmops2dAlmlineMeasAla
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| pmops2dAlmlineMeasAlaIndexIndex definition for the pmops2dAlmlineMeasAla table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.2.3.2.40.1.1 | ||||
| pmops2dAlmLineTxPwrLowAlaPortnTx Low Alarm :This OID indicates that Transmit power or the OPS is lower than the alarm threshold of the OPS <Help> This alarm indicates if the receive power on the transmit side of the OPS is too low <Condtype>… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.40.1.2 | ||||
| pmops2dAlmLineTxPwrHighAlaPortnTx High Alarm : This OID indicates that Transmit power or the OPS is higher than the alarm threshold of the OPS <Help> This alarm indicates if the receive power on the transmit side of the OPS is too high <Condt… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.40.1.3 | ||||
| pmops2dAlmLineRxPwrLowAlaPortnRx Low Alarm :This OID indicates that Receive power or the OPS is lower than the alarm threshold of the OPS <Help> This alarm indicates if the receive power on the receive side of the OPS is too low <Condtype> L… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.40.1.4 | ||||
| pmops2dAlmLineRxPwrHighAlaPortnRx High Alarm : This OID indicates that Receive power of the OPS is higher than the alarm threshold of the OPS <Help> This alarm indicates if the receive power on the receive side of the OPS is too high <Condtyp… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.2.40.1.5 |
.1.3.6.1.4.1.20044.71.2.3.3.16
·
1 row entry
·
5 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dAlmsynthLineAlmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dAlmsynthLineAlmTable'
List of pmops2dAlmsynthLineAlm Article
Row definition for the pmops2dAlmsynthLineAlm
table
table
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| pmops2dAlmsynthLineAlmIndexIndex definition for the pmops2dAlmsynthLineAlm table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.2.3.3.16.1.1 | ||||
| pmops2dAlmLineHwFailAccPortnHW_Fail_Acc :This OID indicates a line hardware failure on the OPS <Help> This alarm indicates if a line HW fail access Alarm has been detected on the OPS <Condtype> LINE_HW_FAIL_ACC <Probcause> equipmentMalfunct… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.3.16.1.5 | ||||
| pmops2dAlmLineMeasWngPortnMeasure Warning :This OID indicates a line warning is present coming out of OPS diagnostic monitoring <Help> This alarm indicates if a line diagnostic monitoring Warning has been detected on the OPS <Condtype> … | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.3.16.1.10 | ||||
| pmops2dAlmLineMeasAlmPortnMeasure Alarm :This OID indicates an line alarm is present coming out of OPS diagnostic monitoring <Help> This alarm indicates if a line diagnostic monitoring Alarm has been detected on the OPS <Condtype> LINE_M… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.3.16.1.11 | ||||
| pmops2dAlmLineFailAccPortnLine_Acc_Fail :This OID indicates a line failure on the OPS <Help> This alarm indicates if a line fail access Alarm has been detected on the OPS <Condtype> LINE_FAIL_ACC <Probcause> equipmentMalfunction (16) <Al… | EKINOPS-MIBEkiOnOff Type Values:
| .1.3.6.1.4.1.20044.71.2.3.3.16.1.13 |
pmops2dMesrtxPowerTable
table.1.3.6.1.4.1.20044.71.3.3.16
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dMesrtxPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dMesrtxPowerTable'
List of pmops2dMesrtxPower Article
Row definition for the pmops2dMesrtxPower
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dMesrtxPowerIndexIndex definition for the pmops2dMesrtxPower table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.3.3.16.1.1 |
| pmops2dMesrtxPowerPortnTX Power :This OID gives the transmit power value of the signal , read on the coupler output (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the Transmit optical power on the TX of the OPS | Integer32 Constraints: range: 0-65535 | .1.3.6.1.4.1.20044.71.3.3.16.1.2 |
pmops2dMesrrxPowerTable
table.1.3.6.1.4.1.20044.71.3.3.24
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dMesrrxPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dMesrrxPowerTable'
List of pmops2dMesrrxPower Article
Row definition for the pmops2dMesrrxPower
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dMesrrxPowerIndexIndex definition for the pmops2dMesrrxPower table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.3.3.24.1.1 |
| pmops2dMesrrxPowerPortnRX Power :This OID gives the receive power value of the signal , read on the switch input (Power=(AV-32768)*0.005) (Unit = dBm) <Help> This measure gives the Receive optical power on the RX of the OPS | Integer32 Constraints: range: 0-65535 | .1.3.6.1.4.1.20044.71.3.3.24.1.2 |
pmops2dRinvSfpTable
table.1.3.6.1.4.1.20044.71.7.1.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dRinvSfpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dRinvSfpTable'
List of the clients on the selected module
Row definition for the client table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dRinvSfpIndexIndex for Sfp table | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.20044.71.7.1.1.1.1 |
| pmops2dRinvSfpInventory for the Clients: This OID contains the inventory for the clients | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.20044.71.7.1.1.1.2 |
pmops2dRinvLineTable
table.1.3.6.1.4.1.20044.71.7.1.2
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dRinvLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dRinvLineTable'
List of the lines on the selected module
Row definition for the line table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dRinvLineIndexIndex for line table | Integer32 Constraints: range: 1-16 | .1.3.6.1.4.1.20044.71.7.1.2.1.1 |
| pmops2dRinvLineInventory for the lines: This OID contains the inventory for the lines | SNMPv2-TCDisplayString Type Constraints: range: 0..255Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.20044.71.7.1.2.1.2 |
.1.3.6.1.4.1.20044.71.9.1.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dCfgClientcaiscsfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dCfgClientcaiscsfTable'
List of Article
Row definition for the accessCAisCsf
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dCfgClientcaiscsfIndexIndex definition for the clientcaiscsf table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.9.1.1.1.1 |
| pmops2dCfgReservedPortn: | Unsigned32r/w Constraints: range: 0-65536 | .1.3.6.1.4.1.20044.71.9.1.1.1.3 |
.1.3.6.1.4.1.20044.71.9.2.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dCfgClientStartupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dCfgClientStartupTable'
List of Article
Row definition for the startUp
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dCfgClientStartupIndexIndex definition for the clientStartup table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.9.2.1.1.1 |
| pmops2dCfgClientSwitchModePortnDefault setting on OPS switch :This register configures the default switch mode | Unsigned32r/w Constraints: range: 0-65536 | .1.3.6.1.4.1.20044.71.9.2.1.1.3 |
.1.3.6.1.4.1.20044.71.9.2.2
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dCfgLineStartupThreshTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dCfgLineStartupThreshTable'
List of Article
Row definition for the startUp
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dCfgLineStartupThreshIndexIndex definition for the lineStartupThresh table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.9.2.2.1.1 |
| pmops2dCfgLineRxPwrSettingPortnDefault setting on OPS Rx Pwr :This register configures the default RX1 Loss threshold on the OPS B (Unit = dBm) | Unsigned32r/w Constraints: range: 0-65536 | .1.3.6.1.4.1.20044.71.9.2.2.1.4 |
.1.3.6.1.4.1.20044.71.9.4.1
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dCfgLabelclientTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dCfgLabelclientTable'
List of Article
Row definition for the labels
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dCfgLabelclientIndexIndex definition for the labelclient table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.9.4.1.1.1 |
| pmops2dCfgLabelclientPortnDefault settings on the label of the clients :These registers configures the default initialisation settings of the labels of the ports. | SNMPv2-TCDisplayStringr/w Constraints: range: 1-16Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.20044.71.9.4.1.1.3 |
pmops2dCfgLabellineTable
table.1.3.6.1.4.1.20044.71.9.4.2
·
1 row entry
·
2 columns
Uses the ekinops variant from
Command help
/opt/observium/mibs/ekinops.
Walk pmops2dCfgLabellineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pmops2d-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmops2d-MIB::pmops2dCfgLabellineTable'
List of Article
Row definition for the labels
table
table
Indexes
| Column | Syntax | OID |
|---|---|---|
| pmops2dCfgLabellineIndexIndex definition for the labelline table | Integer32 Constraints: range: 0-128 | .1.3.6.1.4.1.20044.71.9.4.2.1.1 |
| pmops2dCfgLabellinePortnDefault settings on the label of the lines :These registers configures the default initialisation settings of the labels of the lines. | SNMPv2-TCDisplayStringr/w Constraints: range: 1-16Description: Represents textual information taken from the NVT ASCII character set, as defined in pages 4, 10-11 of RFC 854. To summarize RFC 854, the NVT ASCII repertoire specifies: - the use of c… | .1.3.6.1.4.1.20044.71.9.4.2.1.3 |