EKINOPS-Pm1004VDC-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
74
Rows
74
Columns
313
.1.3.6.1.4.1.20044.38.2.2.1.48 · 1 row entry · 11 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmsfpWarnDdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmsfpWarnDdmTable'
List of pm1004vdcAlmsfpWarnDdm 
Article
pm1004vdcAlmsfpWarnDdmEntry row .1.3.6.1.4.1.20044.38.2.2.1.48.1
Row definition for the pm1004vdcAlmsfpWarnDdm
table
Column Syntax OID
Index definition for the pm1004vdcAlmsfpWarnDdm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.1.48.1.1
Client SFP Tx Power Low Warning
:Warning indicating that the SFP
output power of port is lower than
the threshold value written in
the SFP EEPROM <Condtype> TX_PW_LOW_WNG_1
<Probcause> transmitterFailure
(56) <Ala…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.2
Client SFP Tx Power High Warning
:Warning indicating that the SFP
output power of port is higher
than the threshold value written
in the SFP EEPROM <Condtype> TX_PWR_HIGH_WNG_1
<Probcause> transmitterFailure
(56) …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.3
Client SFP Bias Low Warning :Warning
indicating that the SFP laser bias
current of port is lower than the
threshold value written in the
SFP EEPROM <Condtype> TX_BIAS_LOW_WNG_1
<Probcause> transmitterFailure
(56) …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.4
Client SFP Bias High Warning :Warning
indicating that the SFP laser bias
current of port is higher than
the threshold value written in
the SFP EEPROM <Condtype> TX_BIAS_HIGH_WNG_1
<Probcause> transmitterFailure
(5…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.5
Client SFP Power Supply Low Warning
:Warning indicating that the SFP
power supply of port is lower than
the threshold value written in
the SFP EEPROM <Condtype> VCC_LOW_WNG_1
<Probcause> powerProblem (36) <Alarmty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.6
Client SFP Power Supply High Warning
:Warning indicating that the SFP
power supply of port is higher
than the threshold value written
in the SFP EEPROM <Condtype> VCC_HIGH_WNG_1
<Probcause> powerProblem (36) <Alar…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.7
Client SFP Temp Low Warning :Warning
indicating that the SFP temperature
of port is lower than the threshold
value written in the SFP EEPROM
<Condtype> TEMP_LOW_WNG_1 <Probcause>
temperatureUnacceptable (51) <Alarm…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.8
Client SFP Temp High Warning :Warning
indicating that the SFP temperature
of port is higher than the threshold
value written in the SFP EEPROM
<Condtype> TEMP_HIGH_WNG_1 <Probcause>
temperatureUnacceptable (51) <Al…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.9
Client SFP Rx Power Low Warning
:Warning indicating that the SFP
input power of port is lower than
the threshold value written in
the SFP EEPROM <Condtype> RX_PWR_LOW_WNG_1
<Probcause> receiveFailure (41)
<Alarmty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.16
Client SFP Rx Power High Warning
:Warning indicating that the SFP
input power of port is higher than
the threshold value written in
the SFP EEPROM <Condtype> RX_PWR_HIGH_WNG_1
<Probcause> receiveFailure (41)
<Alar…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.48.1.17
.1.3.6.1.4.1.20044.38.2.2.1.56 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmsfpCritDdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmsfpCritDdmTable'
List of pm1004vdcAlmsfpCritDdm 
Article
pm1004vdcAlmsfpCritDdmEntry row .1.3.6.1.4.1.20044.38.2.2.1.56.1
Row definition for the pm1004vdcAlmsfpCritDdm
table
Column Syntax OID
Index definition for the pm1004vdcAlmsfpCritDdm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.1.56.1.1
Client SFP Custom Tx Power Low
:Custom Alarm indicating that the
SFP output power of port is lower
than the custom threshold defined
in configuration <Help> Custom
Alarm indicating that the SFP output
power of p…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.56.1.2
Client SFP Custom Tx Power High
:Custom Alarm indicating that the
SFP output power of port is higher
than the custom threshold defined
in configuration <Help> Custom
Alarm indicating that the SFP output
power of…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.56.1.3
Client SFP Custom Rx Power Low
:Custom Alarm indicating that the
SFP input power of port is lower
than the custom threshold defined
in configuration <Help> Custom
Alarm indicating that the SFP input
power of por…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.56.1.16
Client SFP Custom Rx Power High
:Custom Alarm indicating that the
SFP input power of port is higher
than the custom threshold defined
in configuration <Help> Custom
Alarm indicating that the SFP input
power of p…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.1.56.1.17
.1.3.6.1.4.1.20044.38.2.2.2.32 · 1 row entry · 11 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmsfpAlmDdmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmsfpAlmDdmTable'
List of pm1004vdcAlmsfpAlmDdm
Article
pm1004vdcAlmsfpAlmDdmEntry row .1.3.6.1.4.1.20044.38.2.2.2.32.1
Row definition for the pm1004vdcAlmsfpAlmDdm
table
Column Syntax OID
Index definition for the pm1004vdcAlmsfpAlmDdm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.2.32.1.1
Client SFP Tx Power Low :Alarm
indicating that the SFP output
power of port is lower than the
threshold value written in the
SFP EEPROM <Condtype> TX_PWR_LOW_ALA_1
<Probcause> transmitterFailure
(56) <Alarmtype> e…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.2
Client SFP Tx Power High :Alarm
indicating that the SFP output
power of port is higher than the
threshold value written in the
SFP EEPROM <Condtype> TX_PWR_HIGH_ALA_1
<Probcause> transmitterFailure
(56) <Alarmtype…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.3
Client SFP Bias Low :Alarm indicating
that the SFP laser bias current
of port is lower than the threshold
value written in the SFP EEPROM
<Condtype> TX_BIAS_LOW_ALA_1 <Probcause>
transmitterFailure (56) <Alarmtype>…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.4
Client SFP Bias High :Alarm indicating
that the SFP laser bias current
of port is higher than the threshold
value written in the SFP EEPROM
<Condtype> TX_BIAS_HIGH_ALA_1 <Probcause>
transmitterFailure (56) <Alarmty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.5
Client SFP Power Supply Low :Alarm
indicating that the SFP power supply
of port is lower than the threshold
value written in the SFP EEPROM
<Condtype> VCC_LOW_ALA_1 <Probcause>
powerProblem (36) <Alarmtype> equipm…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.6
Client SFP Power Supply High :Alarm
indicating that the SFP power supply
of port is higher than the threshold
value written in the SFP EEPROM
<Condtype> VCC_HIGH_ALA_1 <Probcause>
powerProblem (36) <Alarmtype> equ…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.7
Client SFP Temp Low :Alarm indicating
that the SFP temperature of port
is lower than the threshold value
written in the SFP EEPROM <Condtype>
TEMP_LOW_ALA_1 <Probcause> temperatureUnacceptable
(51) <Alarmtype> equi…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.8
Client SFP Temp High :Alarm indicating
that the SFP temperature of port
is higher than the threshold value
written in the SFP EEPROM <Condtype>
TEMP_HIGH_ALA_1 <Probcause> temperatureUnacceptable
(51) <Alarmtype> e…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.9
Client SFP Rx Power Low :Alarm
indicating that the SFP input power
of port is lower than the threshold
value written in the SFP EEPROM
<Condtype> RX_PWR_LOW_ALA_1 <Probcause>
receiveFailure (41) <Alarmtype>
equipm…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.16
Client SFP Rx Power High :Alarm
indicating that the SFP input power
of port is higher than the threshold
value written in the SFP EEPROM
<Condtype> RX_PWR_HIGH_ALA_1 <Probcause>
receiveFailure (41) <Alarmtype>
equ…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.2.32.1.17
.1.3.6.1.4.1.20044.38.2.2.3.8 · 1 row entry · 14 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmsynthAlmPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmsynthAlmPortTable'
List of pm1004vdcAlmsynthAlmPort 
Article
pm1004vdcAlmsynthAlmPortEntry row .1.3.6.1.4.1.20044.38.2.2.3.8.1
Row definition for the pm1004vdcAlmsynthAlmPort
table
Column Syntax OID
Index definition for the pm1004vdcAlmsynthAlmPort
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.3.8.1.1
Client Optical Module Absent :This
OID indicates that the SFP module
is not present in the client port
(only significant on Client6-GbE
port). <Help> This alarm indicates
if the client transceiver is present
(…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.2
DDM Supported On Client SFP :This
OID indicates that the Client SFP
module supports the Digital Diagnostic
Monitoring function (only significant
on Client6-GbE port) <Help>
This status indicates if the
client …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.3
Client HW Fail :This OID indicates
a failure on client port, most
probably caused by a HW issue.
<Condtype> HW_FAIL_ACC_1 <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.5
Client Signal Shutdown :This OID
indicates the Client SFP transmitter
output is ON. <Help> This status
indicates if the client transceiver
is ON or OFF <Condtype> DW_LSD_1
<Probcause> other (1) <Alarmtype>
eq…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.6
Tx Client Port In Service :This
OID indicates that the local Tx
Client port is In Service (1) or
Out of Service (2) <Help> This
status indicates if the local Tx
client port is in service
<Condtype>
CLIENT_LOCAL…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.7
Rx Client Port In Service :This
OID indicates that the local Rx
Client port is In Service (1) or
Out of Service (2) <Help> This
status indicates if the local Rx
client port is in service <Condtype>
CLIENT_LOCAL…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.8
Client AIS Inserted :This OID
indicates a CAIS has been inserted
on the output client port. <Help>
This status indictaes if a Client
Alarm Indication Signal is currently
inserted on the client interface
<Condty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.9
Warning On Client SFP DDM :This
OID indicates a warning is being
received from the Client SFP DDM
(only significant on Client6-GbE
port) <Help> This alarm indicates
if a DDM Warning has been detected
on the cl…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.10
Alarm On Client SFP DDM :This
OID indicates an alarm is being
received from the Client SFP DDM
(only significant on Client6-GbE
port) <Help> This alarm indicates
if a DDM Alarm has been detected
on the client …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.11
Custom Alarm On Client SFP DDM
:This OID indicates a Custom alarm
is being received from the Client
SFP DDM <Help> This alarm indicates
if a DDM Custom Alarm has been
detected on the client transceiver
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.12
Client Access Fail :This OID indicates
a failure on the Client port <Condtype>
FAIL_ACC_1 <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.13
Client Sink (Line1 Or Line2) :This
bit indicates the Client #n is
active on receive side <Help>
This status indicates whether
the Client is extracted from Line
1 or Line 2. <Condtype> CLIENT_ACTIVE
<Probcause> o…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.16
Client Signal Fail Inserted :This
OID indicates a CSF has been inserted
in the upstream client port. <Help>
This status indicates if a Client
Signal Fail is currently inserted
on the line signal for this client
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.8.1.17
.1.3.6.1.4.1.20044.38.2.2.3.16 · 1 row entry · 3 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmaccessioAlmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmaccessioAlmTable'
List of pm1004vdcAlmaccessioAlm 
Article
pm1004vdcAlmaccessioAlmEntry row .1.3.6.1.4.1.20044.38.2.2.3.16.1
Row definition for the pm1004vdcAlmaccessioAlm
table
Column Syntax OID
Index definition for the pm1004vdcAlmaccessioAlm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.3.16.1.1
Client SFP Tx Failed :This OID
indicates that the transmitter
fails for the SFP plugged into
the client port. This alarm reports
the transmitter failure alarm generated
by the SFPs. <Help> This alarm
indicates …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.16.1.2
Client Input Loss Of Signal :This
OID indicates that no signal is
present on the client port <Help>
This alarm indicates if a signal
is detected on the client input
<Condtype> UP_LOS_1 <Probcause>
receiveFailur…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.16.1.5
.1.3.6.1.4.1.20044.38.2.2.3.72 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmmapperDeAlmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmmapperDeAlmTable'
List of pm1004vdcAlmmapperDeAlm 
Article
pm1004vdcAlmmapperDeAlmEntry row .1.3.6.1.4.1.20044.38.2.2.3.72.1
Row definition for the pm1004vdcAlmmapperDeAlm
table
Column Syntax OID
Index definition for the pm1004vdcAlmmapperDeAlm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.3.72.1.1
Client Loss Of Synchro :This OID
indicates the upstream client input
port has lost synchronization on
its decoder <Help> This alarms
indicates if the input client signal
is correctly synchronized with
the deco…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.72.1.2
Client Upstream Buffer Overload
:This OID indicates that the rate
adaptation buffer for client port
is in overload. <Help> This alarm
indicates if there is a upstream
FIFO overload for this client port
<Condtype…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.72.1.11
Client Signal Fail Detected :This
OID indicates that a CSF has been
detected on client port in the
downstream direction <Help>
This alarm indicates if a Client
Signal Fail has been detected in
the incoming line…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.72.1.12
Client Downstream Buffer Overload
:This OID indicates that the de-mapper
buffer for client port is in overload.
<Help> This alarm indicates if
there is a downstream FIFO overload
for this client port <Condtype>
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.72.1.15
.1.3.6.1.4.1.20044.38.2.2.3.112 · 1 row entry · 13 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmvideoProtocolStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmvideoProtocolStatusTable'
List of pm1004vdcAlmvideoProtocolStatus 
Article
pm1004vdcAlmvideoProtocolStatusEntry row .1.3.6.1.4.1.20044.38.2.2.3.112.1
Row definition for the pm1004vdcAlmvideoProtocolStatus
table
Column Syntax OID
Index definition for the pm1004vdcAlmvideoProtocolStatus
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.2.3.112.1.1
SDI Detected On Tx :This OID indicates
that the SDI protocol has been
detected on the transmit side
of the port (only significant
on Video2 to Video 5 ports)
<Help> This status indicates
that the SDI protocol …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.2
HD-SDI-PAL Detected On Tx :This
OID indicates that the HD-SDI-PAL
protocol has been detected on the
transmit side of the port (only
significant on Video2 to Video
5 ports) <Help> This status
indicates that the …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.3
HD-SDI-NTSC Detected On Tx :This
OID indicates that the HD-SDI-NTSC
protocol has been detected on the
transmit side of the port (only
significant on Video2 to Video
5 ports)
<Help> This status
indicates that the…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.4
DVB-ASI Detected On Tx :This OID
indicates that the DVB-ASI protocol
has been detected on the transmit
side of the port (only significant
on Video2 to Video 5 ports)
<Help>
This status indicates that the
DVB-ASI…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.5
Fast Ethernet Detected On Tx :This
OID indicates that the Fast Ethernet
protocol has been detected on the
port (only significant on Client1-RJ45
port)
<Help> This status indicates
that the Fast Ethernet protocol …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.6
Gigabit Ethernet Detected On Tx

:This OID indicates that the
Gigabit Ethernet protocol has
been detected on the port (only
significant on Client6-GbE port)

<Help> This status indicat…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.7
SDI Detected On Rx :This OID indicates
that the SDI protocol has been
detected on the receive side of
the port (only significant on Video2
to Video 5 ports)
<Help> This
status indicates that the SDI protocol
has…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.10
HD-SDI-PAL Detected On Rx :This
OID indicates that the HD-SDI-PAL
protocol has been detected on the
receive side of the port (only
significant on Video2 to Video
5 ports)
<Help> This status
indicates that the HD…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.11
HD-SDI-NTSC Detected On Rx :This
OID indicates that the HD-SDI-NTSC
protocol has been detected on the
receive side of the port (only
significant on Video2 to Video
5 ports)
<Help> This status
indicates that the …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.12
DVB-ASI Detected On Rx :This OID
indicates that the DVB-ASI protocol
has been detected on the receive
side of the port (only significant
on Video2 to Video 5 ports) <Help>
This status indicates that the
DVB-ASI…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.13
Fast Ethernet Detected On Rx :This
OID indicates that the Fast Ethernet
protocol has been detected on the
port (only significant on Client1-RJ45
port)
<Help> This status indicates
that the Fast Ethernet protocol …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.14
Gigabit Ethernet Detected On Rx

:This OID indicates that the
Gigabit Ethernet protocol has
been detected on the port (only
significant on Client6-GbE port)

<Help> This status indicat…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.2.3.112.1.15
.1.3.6.1.4.1.20044.38.2.3.1.209 · 1 row entry · 9 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineXfp1WarningsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineXfp1WarningsTable'
List of pm1004vdcAlmlineXfp1Warnings 
Article
pm1004vdcAlmlineXfp1WarningsEntry row .1.3.6.1.4.1.20044.38.2.3.1.209.1
Row definition for the pm1004vdcAlmlineXfp1Warnings
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineXfp1Warnings
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.1.209.1.1
Line Optical Tx Power Low Warning
:Warning indicating that the XFP/OTX
transmitter transmitter output
power is lower than the threshold
value written in the XFP/OTX EEPROM
<Condtype> TX_POWER_LOW_WARNING_1
<Probca…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.2
Line Optical Tx Power High Warning
:Warning indicating that the XFP/OTX
transmitter transmitter output
power is higher than the threshold
value written in the XFP EEPROM
<Condtype> TX_POWER_HIGH_WARNING_1
<Probcau…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.3
Line Transceiver Bias Low Warning
:Warning indicating that the XFP/OTX
transmitter laser bias current
is lower than the threshold value
written in the XFP/OTX EEPROM <Condtype>
TX_BIAS_LOW_WARNING_1 <Probcause>
tr…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.4
Line Transceiver Bias High Warning
:Warning indicating that the XFP/OTX
transmitter laser bias current
is higher than the threshold value
written in the XFP EEPROM <Condtype>
TX_BIAS_HIGH_WARNING_1 <Probcause>
tra…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.5
Line Transceiver Temp Low Warning
:Warning indicating that the XFP/OTX
temperature is lower than the threshold
value written in the XFP/OTX EEPROM
<Condtype> TEMP_LOW_WARNING_1 <Probcause>
temperatureUnacceptable (…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.8
Line Transceiver Temp High Warning
:Warning indicating that the XFP/OTX
temperature is higher than the
threshold value written in the
XFP EEPROM <Condtype> TEMP_HIGH_WARNING_1
<Probcause> temperatureUnacceptable
(…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.9
Line Optical Rx Power Low Warning
:Warning indicating that the XFP
received optical power is lower
than the threshold value written
in the XFP EEPROM <Condtype> RX_POWER_LOW_WARNING_1
<Probcause> receiveFailure (4…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.16
Line Optical Rx Power High Warning
:Warning indicating that the XFP
received optical power is higher
than the threshold value written
in the XFP EEPROM <Condtype> RX_POWER_HIGH_WARNING_1
<Probcause> receiveFailure …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.209.1.17
.1.3.6.1.4.1.20044.38.2.3.1.225 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineOtx1TlhWarningsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineOtx1TlhWarningsTable'
List of pm1004vdcAlmlineOtx1TlhWarnings 
Article
pm1004vdcAlmlineOtx1TlhWarningsEntry row .1.3.6.1.4.1.20044.38.2.3.1.225.1
Row definition for the pm1004vdcAlmlineOtx1TlhWarnings
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineOtx1TlhWarnings
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.1.225.1.1
Line Modulator Aging High Warning
:Warning indicating the Line OTX
TLH modulator aging is higher than
the threshold written in the EEPROM
<Condtype> LINE_MODULATOR_AGING_HIGH_WARNING_1
<Probcause> transmitterFailur…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.225.1.6
Line OTX TLH Aging High Warning
:Warning indicating the Line OTX
TLH aging is higher than the threshold
written in the EEPROM <Condtype>
LINE_AGING_HIGH_WARNING_1 <Probcause>
transmitterFailure (56) <Alarmtype>
eq…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.225.1.7
Line Freq. Deviation High Warning
:Warning indicating the Line OTX
TLH frequency deviation is higher
than the threshold written in the
EEPROM <Condtype> LINE_FREQ_DEV_HIGH_WARNING_1
<Probcause> transmitterFailure
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.225.1.13
Line Laser Temp. High Warning
:Warning indicating the Line OTX
TLH laser temperature is higher
than the threshold written in the
EEPROM <Condtype> LINE_LASER_TEMP_HIGH_WARNING_1
<Probcause> temperatureUnacceptable …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.1.225.1.15
.1.3.6.1.4.1.20044.38.2.3.2.208 · 1 row entry · 9 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineXfp1AlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineXfp1AlarmTable'
List of pm1004vdcAlmlineXfp1Alarm 
Article
pm1004vdcAlmlineXfp1AlarmEntry row .1.3.6.1.4.1.20044.38.2.3.2.208.1
Row definition for the pm1004vdcAlmlineXfp1Alarm
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineXfp1Alarm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.2.208.1.1
Line Optical Tx Power Low :Alarm
indicating that the XFP/OTX transmitter
transmitter output power is lower
than the threshold value written
in the XFP/OTX EEPROM <Condtype>
TX_POWER_LOW_ALARM_1 <Probcause>
transmi…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.2
Line Optical Tx Power High :Alarm
indicating that the XFP/OTX transmitter
transmitter output power is higher
than the threshold value written
in the XFP EEPROM <Condtype> TX_POWER_HIGH_ALARM_1
<Probcause> transmitt…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.3
Line Transceiver Bias Low :Alarm
indicating that the XFP/OTX transmitter
laser bias current is lower than
the threshold value written in
the XFP/OTX EEPROM <Condtype>
TX_BIAS_LOW_ALARM_1 <Probcause>
transmitterFai…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.4
Line Transceiver Bias High :Alarm
indicating that the XFP/OTX transmitter
laser bias current is higher than
the threshold value written in
the XFP EEPROM <Condtype> TX_BIAS_HIGH_ALARM_1
<Probcause> transmitterFailu…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.5
Line Transceiver Temp Low :Alarm
indicating that the XFP/OTX temperature
is lower than the threshold value
written in the XFP/OTX EEPROM <Condtype>
TEMP_LOW_ALARM_1 <Probcause> temperatureUnacceptable
(51) <Alarmty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.8
Line Transceiver Temp High :Alarm
indicating that the XFP/OTX temperature
is higher than the threshold value
written in the XFP EEPROM <Condtype>
TEMP_HIGH_ALARM_1 <Probcause> temperatureUnacceptable
(51) <Alarmtyp…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.9
Line Optical Rx Power Low :Alarm
indicating that the XFP received
optical power is lower than the
threshold value written in the
XFP EEPROM <Condtype> RX_POWER_LOW_ALARM_1
<Probcause> receiveFailure (41)
<Alarmty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.16
Line Optical Rx Power High :Alarm
indicating that the XFP received
optical power is higher than the
threshold value written in the
XFP EEPROM <Condtype> RX_POWER_HIGH_ALARM_1
<Probcause> receiveFailure (41)
<Alarm…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.208.1.17
.1.3.6.1.4.1.20044.38.2.3.2.210 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineXfp1CritTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineXfp1CritTable'
List of pm1004vdcAlmlineXfp1Crit 
Article
pm1004vdcAlmlineXfp1CritEntry row .1.3.6.1.4.1.20044.38.2.3.2.210.1
Row definition for the pm1004vdcAlmlineXfp1Crit
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineXfp1Crit
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.2.210.1.1
Line Custom Tx Power Low :Custom
Alarm indicating that the XFP/OTX
output power of port is lower than
the custom threshold defined in
configuration <Help> Custom Alarm
indicating that the XFP/OTX output
power of…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.210.1.2
Line Custom Tx Power High :Custom
Alarm indicating that the XFP/OTX
output power of port is higher
than the custom threshold defined
in configuration <Help> Custom
Alarm indicating that the XFP/OTX
output power …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.210.1.3
Line Custom Rx Power Low :Custom
Alarm indicating that the XFP/OTX
input power of port is lower than
the custom threshold defined in
configuration <Help> Custom Alarm
indicating that the XFP/OTX input
power of p…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.210.1.16
Line Custom Rx Power High :Custom
Alarm indicating that the XFP/OTX
input power of port is higher than
the custom threshold defined in
configuration <Help> Custom Alarm
indicating that the XFP/OTX input
power of…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.210.1.17
.1.3.6.1.4.1.20044.38.2.3.2.212 · 1 row entry · 17 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineXfp1SupplyAlarmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineXfp1SupplyAlarmTable'
List of pm1004vdcAlmlineXfp1SupplyAlarm 
Article
pm1004vdcAlmlineXfp1SupplyAlarmEntry row .1.3.6.1.4.1.20044.38.2.3.2.212.1
Row definition for the pm1004vdcAlmlineXfp1SupplyAlarm
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineXfp1SupplyAlarm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.2.212.1.1
VEE5 Power Supply Low :Alarm indicating
the XFP/OTX VEE5 power supply is
lower than the threshold written
in the EEPROM <Condtype> VEE5_LOW_ALARM_1
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Pola…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.2
VEE5 Power Supply High :Alarm
indicating the XFP/OTX VEE5 power
supply is higher than the threshold
written in the EEPROM <Condtype>
VEE5_HIGH_ALARM_1 <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.3
VCC2 Power Supply Low :Alarm indicating
the XFP/OTX VCC2 power supply is
lower than the threshold written
in the EEPROM <Condtype> VCC2_LOW_ALARM_1
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Pola…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.4
VCC2 Power Supply High :Alarm
indicating the XFP/OTX VCC2 power
supply is higher than the threshold
written in the EEPROM <Condtype>
VCC2_HIGH_ALARM_1 <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.5
VCC3 Power Supply Low :Alarm indicating
the XFP/OTX VCC3 power supply is
lower than the threshold written
in the EEPROM <Condtype> VCC3_LOW_ALARM_1
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Pola…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.6
VCC3 Power Supply High :Alarm
indicating the XFP/OTX VCC3 power
supply is higher than the threshold
written in the EEPROM <Condtype>
VCC3_HIGH_ALARM_1 <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.7
VCC5 Power Supply Low :Alarm indicating
the XFP/OTX VCC5 power supply is
lower than the threshold written
in the EEPROM <Condtype> VCC5_LOW_ALARM_1
<Probcause> powerProblem (36) <Alarmtype>
equipmentAlarm (5) <Pola…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.8
VCC5 Power Supply High :Alarm
indicating the XFP/OTX VCC5 power
supply is higher than the threshold
written in the EEPROM <Condtype>
VCC5_HIGH_ALARM_1 <Probcause> powerProblem
(36) <Alarmtype> equipmentAlarm
(5) <…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.9
VEE5 Power Supply Low Warning
:Warning indicating the XFP/OTX
VEE5 power supply is lower than
the threshold written in the EEPROM
<Condtype> VEE5_LOW_WARNING_1 <Probcause>
powerProblem (36) <Alarmtype> equipmentAla…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.10
VEE5 Power Supply High Warning
:Warning indicating the XFP/OTX
VEE5 power supply is higher than
the threshold written in the EEPROM
<Condtype> VEE5_HIGH_WARNING_1
<Probcause> powerProblem (36)
<Alarmtype> equipmen…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.11
VCC2 Power Supply Low Warning
:Warning indicating the XFP/OTX
VCC2 power supply is lower than
the threshold written in the EEPROM
<Condtype> VCC2_LOW_WARNING_1 <Probcause>
powerProblem (36) <Alarmtype> equipmentAla…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.12
VCC2 Power Supply High Warning
:Warning indicating the XFP/OTX
VCC2 power supply is higher than
the threshold written in the EEPROM
<Condtype> VCC2_HIGH_WARNING_1
<Probcause> powerProblem (36)
<Alarmtype> equipmen…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.13
VCC3 Power Supply Low Warning
:Warning indicating the XFP/OTX
VCC3 power supply is lower than
the threshold written in the EEPROM
<Condtype> VCC3_LOW_WARNING_1 <Probcause>
powerProblem (36) <Alarmtype> equipmentAla…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.14
VCC3 Power Supply High Warning
:Warning indicating the XFP/OTX
VCC3 power supply is higher than
the threshold written in the EEPROM
<Condtype> VCC3_HIGH_WARNING_1
<Probcause> powerProblem (36)
<Alarmtype> equipmen…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.15
VCC5 Power Supply Low Warning
:Warning indicating the XFP/OTX
VCC5 power supply is lower than
the threshold written in the EEPROM
<Condtype> VCC5_LOW_WARNING_1 <Probcause>
powerProblem (36) <Alarmtype> equipmentAla…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.16
VCC5 Power Supply High Warning
:Warning indicating the XFP/OTX
VCC5 power supply is higher than
the threshold written in the EEPROM
<Condtype> VCC5_HIGH_WARNING_1
<Probcause> powerProblem (36)
<Alarmtype> equipmen…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.212.1.17
.1.3.6.1.4.1.20044.38.2.3.2.224 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineOtx1TlhAlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineOtx1TlhAlarmsTable'
List of pm1004vdcAlmlineOtx1TlhAlarms 
Article
pm1004vdcAlmlineOtx1TlhAlarmsEntry row .1.3.6.1.4.1.20044.38.2.3.2.224.1
Row definition for the pm1004vdcAlmlineOtx1TlhAlarms
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineOtx1TlhAlarms
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.2.224.1.1
Line Modulator Aging High Alarm
:Alarm indicating the Line OTX
TLH modulator aging is higher
than the threshold written in
the EEPROM <Condtype> LINE_MODULATOR_AGING_HIGH_ALA_1
<Probcause> transmitterFailure
(56) …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.224.1.6
Line OTX TLH Aging High Alarm
:Alarm indicating the Line OTX
TLH aging is higher than the threshold
written in the EEPROM <Condtype>
LINE_AGING_HIGH_ALA_1 <Probcause>
transmitterFailure (56) <Alarmtype>
equipmentA…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.224.1.7
Line Freq. Deviation High Alarm
:Alarm indicating the Line OTX
TLH frequency deviation is higher
than the threshold written in the
EEPROM <Condtype> LINE_FREQ_DEV_HIGH_ALA_1
<Probcause> transmitterFailure
(56) <Al…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.224.1.13
Line Laser Temp. High Alarm :Alarm
indicating the Line OTX TLH laser
temperature is higher than the
threshold written in the EEPROM
<Condtype> LINE_LASER_TEMP_HIGH_ALA_1
<Probcause> temperatureUnacceptable
(51) <A…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.2.224.1.15
.1.3.6.1.4.1.20044.38.2.3.3.7 · 1 row entry · 11 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmsynthAlmLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmsynthAlmLineTable'
List of pm1004vdcAlmsynthAlmLine 
Article
pm1004vdcAlmsynthAlmLineEntry row .1.3.6.1.4.1.20044.38.2.3.3.7.1
Row definition for the pm1004vdcAlmsynthAlmLine
table
Column Syntax OID
Index definition for the pm1004vdcAlmsynthAlmLine
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.3.7.1.1
Line Optical Module Absent :This
OID indicates that the line optical
interface (XFP or OTX) is not plugged
in. <Help> This alarm indicates
if the line transceiver is present.
<Condtype> XFP_ABSENT <Probcause>
in…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.2
Line Optical Module Ready :This
OID indicates that the optical
interface (XFP or OTX) is not
operational. <Help> This status
indicates if the line transceiver
has been correctly initialized
<Condtype> XFP_INIT_N…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.3
Line Port HW Failure :This OID
indicates a failure on line port,
most probably caused by a HW issue
<Condtype> LINE_HW_FAIL <Probcause>
equipmentMalfunction (16) <Alarmtype>
synthesisAlarm (12) <Polarity>
(2)
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.5
Line Optical Module Laser Shutdown
:This OID indicates the line optical
output power is on <Help> This
status indicates if the line transceiver
laser is ON or OFF <Condtype> XFP_TX_OFF
<Probcause> other (1) <Alar…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.6
Line Port In Service :This OID
indicates that the Line port is
In Service (1) of Out or Service
(2) <Help> This status indicates
if the line port is in service
<Condtype> LINE_LOCAL_OOS <Probcause>
informational…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.7
Warning On Line Optical Module
DDM :This OID indicates a warning
is present coming out of Line optical
interface DDM <Help> This alarm
indicates if a DDM Warning has
been detected on the line transceiver
<Condty…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.10
Alarm On Line Optical Module DDM
:This OID indicates an alarm is
present coming out of Line optical
interface DDM <Help> This alarm
indicates if a DDM Alarm has been
detected on the line transceiver
<Condtype> L…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.11
Custom Alarm On Line XFP/OTX DDM
:This OID indicates a Custom alarm
is present coming out of Line optical
interface DDM <Help> This
alarm indicates if a DDM Custom
Alarm has been detected on the
line transcei…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.12
Line Port Failure :This OID indicates
a failure on the line port <Condtype>
LINE_FAIL <Probcause> equipmentMalfunction
(16) <Alarmtype> synthesisAlarm
(12) <Polarity> (2)
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.13
Line Active :This bit indicates
the line #n is active on receive
side <Help> This status indicates
whether the line is active or standby.
<Condtype> LINE_ACTIVE <Probcause>
informationalStatus(1000) <Alarmtype>
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.7.1.17
.1.3.6.1.4.1.20044.38.2.3.3.128 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmdfrmAlmTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmdfrmAlmTable'
List of pm1004vdcAlmdfrmAlm Article
pm1004vdcAlmdfrmAlmEntry row .1.3.6.1.4.1.20044.38.2.3.3.128.1
Row definition for the pm1004vdcAlmdfrmAlm
table
Column Syntax OID
Index definition for the pm1004vdcAlmdfrmAlm
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.3.128.1.1
Loss Of Synchronisation :This
OID indicates the upstream line
input port is in Loss of Synchronization.
<Help> This alarms indicates
if the input signal is correctly
synchronized <Condtype> DW_LOSSOFSYNC_1
<Prob…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.128.1.5
.1.3.6.1.4.1.20044.38.2.3.3.133 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineSyncAlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineSyncAlarmsTable'
List of pm1004vdcAlmlineSyncAlarms 
Article
pm1004vdcAlmlineSyncAlarmsEntry row .1.3.6.1.4.1.20044.38.2.3.3.133.1
Row definition for the pm1004vdcAlmlineSyncAlarms
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineSyncAlarms
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.3.133.1.1
Downstream Clock Lock Error :This
OID indicates that the deserializer
input 10 Gb/s clock recovery is
not locked. <Condtype> DW_LOCKERR
<Probcause> receiveFailure (41)
<Alarmtype> equipmentAlarm (5)
<Polarity> (2)
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.133.1.13
Upstream Clock Lock Error :This
OID indicates that the serializer
output 10 Gb/s clock multiplier
unit is not locked. <Condtype>
UP_LOCKERR <Probcause> receiveFailure
(41) <Alarmtype> equipmentAlarm
(5) <Polarity>…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.133.1.14
Line Input Loss Of Signal :This
OID indicates a loss of signal
on the 10 Gb/s input. <Help>
This alarm indicates if an optical
signal is detected on the line
transceiver input <Condtype> DW_LOS
<Probcause> recei…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.133.1.17
.1.3.6.1.4.1.20044.38.2.3.3.211 · 1 row entry · 10 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcAlmlineXfp1AlarmsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcAlmlineXfp1AlarmsTable'
List of pm1004vdcAlmlineXfp1Alarms 
Article
pm1004vdcAlmlineXfp1AlarmsEntry row .1.3.6.1.4.1.20044.38.2.3.3.211.1
Row definition for the pm1004vdcAlmlineXfp1Alarms
table
Column Syntax OID
Index definition for the pm1004vdcAlmlineXfp1Alarms
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.2.3.3.211.1.1
Line Optical Module Not Ready
:This OID indicates that the module
is unable to determine correct
data. <Help> This alarm indicates
if the line transceiver is ready
<Condtype> MOD_NR_1 <Probcause>
receiveFailure …
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.3
Line Optical Rx CDR Unlocked :This
OID indicates that a loss of lock
on the receiving side CDR has been
detected <Help> This alarm indicates
if the Rx CDR is locked in the
line transceiver <Condtype> RX_CDR_NOT_L…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.4
Line Optical Rx Not Ready :This
OID indicates that a condition
has arisen leading to invalid
data on the receiving side. <Help>
This alarm indicates if the Rx
part of the line transceiver is
ready <Condtype> RX_…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.6
Line Optical Tx CDR Unlocked :This
OID indicates a loss of lock on
the transmitting side CDR has been
detected. <Help> This alarm indicates
if the Tx CDR is locked in the
line transceiver <Condtype> TX_CDR_NOT_LO…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.7
Line Optical Tx Failure :This
OID indicates a fault condition
on the laser detected by the safety
syste <Help> This alarm indicates
if the laser of the line transceiver
is in fail condition <Condtype>
TX_FAULT_1…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.8
Line Optical Tx Not Ready :This
OID indicates a condition has arisen
leading to invalid data on the
transmitting side <Help> This
alarm indicates if the Tx part
of the line transceiver is ready
<Condtype> TX_NR_…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.9
Line Optical Tx Wavelength Unlocked
:This OID indicates that the wavelength
error is exceeding the manufacturer
tolerance <Help> This alarm indicates
if the wavelenght of the line transceiver
is locked <Condtype>…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.15
Line Optical Tx Temp Regul Failed
:This OID indicates a failure on
the TEC module <Help> This alarm
indicates if the TEC of the line
transceiver is in fail condition
<Condtype> TEC_FAULT_1 <Probcause>
transmitte…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.16
Line Rx Photodiode Power Failed
:This OID indicates a failure on
the APD power supply <Help> This
alarm indicates if the APD power
supply is in fail condition <Condtype>
APD_SUPPLY_FAULT_1 <Probcause>
receiverFa…
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.2.3.3.211.1.17
.1.3.6.1.4.1.20044.38.3.2.16 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrtempMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrtempMeasTable'
List of pm1004vdcMesrtempMeas
Article
pm1004vdcMesrtempMeasEntry row .1.3.6.1.4.1.20044.38.3.2.16.1
Row definition for the pm1004vdcMesrtempMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrtempMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.2.16.1.1
Client SFP Temperature :This OID
gives the temperature value of
the SFP plugged in port, read
from the DDM (Digital Diagnostic
Monitoring) (Temperature = AV/256)
(Unit = C) <Help> This measure
gives the temperat…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.2.16.1.2
.1.3.6.1.4.1.20044.38.3.2.24 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrvoltMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrvoltMeasTable'
List of pm1004vdcMesrvoltMeas
Article
pm1004vdcMesrvoltMeasEntry row .1.3.6.1.4.1.20044.38.3.2.24.1
Row definition for the pm1004vdcMesrvoltMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrvoltMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.2.24.1.1
Client SFP Power Supply :This
OID gives the 3V3 voltage value
of the SFP plugged into port, read
from the DDM (Digital Diagnostic
Monitoring) (Voltage = AV/10000)
(Unit = V) <Help> This measure
gives the 3V3 vol…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.2.24.1.2
.1.3.6.1.4.1.20044.38.3.2.32 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrbiasMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrbiasMeasTable'
List of pm1004vdcMesrbiasMeas
Article
pm1004vdcMesrbiasMeasEntry row .1.3.6.1.4.1.20044.38.3.2.32.1
Row definition for the pm1004vdcMesrbiasMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrbiasMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.2.32.1.1
Client SFP Laser Bias :This OID
gives the bias value of the SFP
plugged into port, read from the
DDM (Digital Diagnostic Monitoring)
(Bias = AV/500) (Unit = mA) <Help>
This measure gives the bias of
the client …
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.2.32.1.2
.1.3.6.1.4.1.20044.38.3.2.40 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrtxpwrMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrtxpwrMeasTable'
List of pm1004vdcMesrtxpwrMeas 
Article
pm1004vdcMesrtxpwrMeasEntry row .1.3.6.1.4.1.20044.38.3.2.40.1
Row definition for the pm1004vdcMesrtxpwrMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrtxpwrMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.2.40.1.1
Client SFP Tx Power :This OID
gives the transmit power value
of the SFP plugged into port, read
from the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV)-40)
(Unit = dBm) <Help> This measure
gives the Tx …
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.2.40.1.2
.1.3.6.1.4.1.20044.38.3.2.48 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrrxpwrMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrrxpwrMeasTable'
List of pm1004vdcMesrrxpwrMeas 
Article
pm1004vdcMesrrxpwrMeasEntry row .1.3.6.1.4.1.20044.38.3.2.48.1
Row definition for the pm1004vdcMesrrxpwrMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrrxpwrMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.2.48.1.1
Client SFP Rx Power :This OID
gives the receive power value
of the SFP plugged into port,
read in the DDM (Digital Diagnostic
Monitoring) (Power = 10*log(AV)-40)
(Unit = dBm) <Help> This measure
gives the Rx opt…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.2.48.1.2
.1.3.6.1.4.1.20044.38.3.3.208 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1LxModTempMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1LxModTempMeasTable'
List of pm1004vdcMesrxfp1LxModTempMeas 
Article
pm1004vdcMesrxfp1LxModTempMeasEntry row .1.3.6.1.4.1.20044.38.3.3.208.1
Row definition for the pm1004vdcMesrxfp1LxModTempMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1LxModTempMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.208.1.1
Line Optical Module Temperature
:This OID gives the temperature
of the XFP or OTX plugged in line#n,
read from the DDM (Digital Diagnostic
Monitoring) (Temperature = AV/256)
(Unit = C) <Help> This measure
gives …
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.208.1.2
.1.3.6.1.4.1.20044.38.3.3.209 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1ReservedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1ReservedTable'
List of pm1004vdcMesrxfp1Reserved 
Article
pm1004vdcMesrxfp1ReservedEntry row .1.3.6.1.4.1.20044.38.3.3.209.1
Row definition for the pm1004vdcMesrxfp1Reserved
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1Reserved
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.209.1.1
Not Used :Reserved
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.209.1.2
.1.3.6.1.4.1.20044.38.3.3.210 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1LoBiasCurrentMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1LoBiasCurrentMeasTable'
List of pm1004vdcMesrxfp1LoBiasCurrentMeas 
Article
pm1004vdcMesrxfp1LoBiasCurrentMeasEntry row .1.3.6.1.4.1.20044.38.3.3.210.1
Row definition for the pm1004vdcMesrxfp1LoBiasCurrentMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1LoBiasCurrentMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.210.1.1
Line Optical Module Laser Bias
:This OID gives the bias value
of the XFP or OTX plugged in line
#n, read from the DDM (Digital
Diagnostic Monitoring) (Bias =
AV/500) (Unit = mA) <Help> This
measure gives the bia…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.210.1.2
.1.3.6.1.4.1.20044.38.3.3.211 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1LoTxPowerMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1LoTxPowerMeasTable'
List of pm1004vdcMesrxfp1LoTxPowerMeas 
Article
pm1004vdcMesrxfp1LoTxPowerMeasEntry row .1.3.6.1.4.1.20044.38.3.3.211.1
Row definition for the pm1004vdcMesrxfp1LoTxPowerMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1LoTxPowerMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.211.1.1
Line Optical Module Tx Power :This
OID gives the transmit power value
of the XFP or OTX plugged in line
#n, read from the DDM (Digital
Diagnostic Monitoring) (Power
= 10*log(AV)-40) (Unit = dBm)
<Help> This me…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.211.1.2
.1.3.6.1.4.1.20044.38.3.3.212 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1LiRxPowerMeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1LiRxPowerMeasTable'
List of pm1004vdcMesrxfp1LiRxPowerMeas 
Article
pm1004vdcMesrxfp1LiRxPowerMeasEntry row .1.3.6.1.4.1.20044.38.3.3.212.1
Row definition for the pm1004vdcMesrxfp1LiRxPowerMeas
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1LiRxPowerMeas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.212.1.1
Line Optical Module Rx Power :This
OID gives the receive power value
of the XFP or OTX plugged in line
#n, read from the DDM (Digital
Diagnostic Monitoring) (Power
= 10*log(AV)-40) (Unit = dBm)
<Help> This meas…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.212.1.2
.1.3.6.1.4.1.20044.38.3.3.213 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1LxAux1MeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1LxAux1MeasTable'
List of pm1004vdcMesrxfp1LxAux1Meas 
Article
pm1004vdcMesrxfp1LxAux1MeasEntry row .1.3.6.1.4.1.20044.38.3.3.213.1
Row definition for the pm1004vdcMesrxfp1LxAux1Meas
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1LxAux1Meas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.213.1.1
Not Used :This OID gives the receive
power value read in the DDM (Digital
Diagnostic Monitoring) of the XFP
or OTX plugged in line #n (Unit
= ?)
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.213.1.2
.1.3.6.1.4.1.20044.38.3.3.214 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrxfp1LxAux2MeasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrxfp1LxAux2MeasTable'
List of pm1004vdcMesrxfp1LxAux2Meas 
Article
pm1004vdcMesrxfp1LxAux2MeasEntry row .1.3.6.1.4.1.20044.38.3.3.214.1
Row definition for the pm1004vdcMesrxfp1LxAux2Meas
table
Column Syntax OID
Index definition for the pm1004vdcMesrxfp1LxAux2Meas
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.214.1.1
Not Used :This OID gives the receive
power value read in the DDM (Digital
Diagnostic Monitoring) of the XFP
or OTX plugged in line #n (Unit
= ?)
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.214.1.2
.1.3.6.1.4.1.20044.38.3.3.224 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrotx1AgingTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrotx1AgingTable'
List of pm1004vdcMesrotx1Aging 
Article
pm1004vdcMesrotx1AgingEntry row .1.3.6.1.4.1.20044.38.3.3.224.1
Row definition for the pm1004vdcMesrotx1Aging
table
Column Syntax OID
Index definition for the pm1004vdcMesrotx1Aging
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.224.1.1
Line OTX TLH Aging :This OID gives
the aging of the Line OTX TLH,
read from the DDM (Digital Diagnostic
Monitoring) (Aging = AV) (Unit
= %) <Help> This measure gives
the aging of the Line OTX TLH
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.224.1.2
.1.3.6.1.4.1.20044.38.3.3.225 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrotx1LaserTemperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrotx1LaserTemperatureTable'
List of pm1004vdcMesrotx1LaserTemperature 
Article
pm1004vdcMesrotx1LaserTemperatureEntry row .1.3.6.1.4.1.20044.38.3.3.225.1
Row definition for the pm1004vdcMesrotx1LaserTemperature
table
Column Syntax OID
Index definition for the pm1004vdcMesrotx1LaserTemperature
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.225.1.1
Line OTX TLH Laser Temperature
:This OID gives the laser temperature
of the Line OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Temperature = AV/256) (Unit =
C) <Help> This measure gives
the laser t…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.225.1.2
.1.3.6.1.4.1.20044.38.3.3.226 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrotx1FreqDeviationTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrotx1FreqDeviationTable'
List of pm1004vdcMesrotx1FreqDeviation 
Article
pm1004vdcMesrotx1FreqDeviationEntry row .1.3.6.1.4.1.20044.38.3.3.226.1
Row definition for the pm1004vdcMesrotx1FreqDeviation
table
Column Syntax OID
Index definition for the pm1004vdcMesrotx1FreqDeviation
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.226.1.1
Line OTX TLH Frequency Deviation
:This OID gives the frequency deviation
of the Line OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Deviation = (AV-32768)*100) (Unit
= MHz) <Help> This measure gives…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.226.1.2
.1.3.6.1.4.1.20044.38.3.3.227 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMesrotx1LaserWvlengthTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMesrotx1LaserWvlengthTable'
List of pm1004vdcMesrotx1LaserWvlength 
Article
pm1004vdcMesrotx1LaserWvlengthEntry row .1.3.6.1.4.1.20044.38.3.3.227.1
Row definition for the pm1004vdcMesrotx1LaserWvlength
table
Column Syntax OID
Index definition for the pm1004vdcMesrotx1LaserWvlength
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.3.3.227.1.1
Line Optical Module Wavelength
:This OID gives the laser wavelength
of the Line OTX TLH, read from
the DDM (Digital Diagnostic Monitoring)
(Wavelength=299792458/((193,100+(AV-32768
)*12,5)*10 3)) (Unit = nm) <Help…
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.20044.38.3.3.227.1.2
.1.3.6.1.4.1.20044.38.4.3.152 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCntdfrmB1ErrCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCntdfrmB1ErrCntTable'
List of pm1004vdcCntdfrmB1ErrCnt 
Article
pm1004vdcCntdfrmB1ErrCntEntry row .1.3.6.1.4.1.20044.38.4.3.152.1
Row definition for the pm1004vdcCntdfrmB1ErrCnt
table
Column Syntax OID
Index definition for the pm1004vdcCntdfrmB1ErrCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.4.3.152.1.1
Line Input SM-BIP8 Errors :This
counter is incremented each time
a B1 error is detected on the Deframer
input stream. <Help> This counter
gives the number of B1 errors on
the line port
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.20044.38.4.3.152.1.2
Line Counter Error :This OID when
set indicates the B1 error counter
value is invalid on Port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.4.3.152.1.3
Line Counter Overload :This OID
when set indicates a B1 error counter
overload on Port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.4.3.152.1.4
.1.3.6.1.4.1.20044.38.4.3.153 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCntdfrmTimCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCntdfrmTimCntTable'
List of pm1004vdcCntdfrmTimCnt 
Article
pm1004vdcCntdfrmTimCntEntry row .1.3.6.1.4.1.20044.38.4.3.153.1
Row definition for the pm1004vdcCntdfrmTimCnt
table
Column Syntax OID
Index definition for the pm1004vdcCntdfrmTimCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.4.3.153.1.1
Line Timer Counter :This is the
timing counter dedicated to the
downstream deframer counters. It
is incremented every 125 us.
SNMPv2-SMICounter32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.20044.38.4.3.153.1.2
Line Counter Error :This OID when
set indicates the deframer timer
counter value is invalid on Port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.4.3.153.1.3
Line Counter Overload :This OID
when set indicates a deframer timer
counter overload on Port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.4.3.153.1.4
.1.3.6.1.4.1.20044.38.6.2.16 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlaccessLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlaccessLoopTable'
List of pm1004vdcCtrlaccessLoop 
Article
pm1004vdcCtrlaccessLoopEntry row .1.3.6.1.4.1.20044.38.6.2.16.1
Row definition for the pm1004vdcCtrlaccessLoop
table
Column Syntax OID
Index definition for the pm1004vdcCtrlaccessLoop
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.16.1.1
Client Facility Loopback :This
OID operates a Client Facility
Loopback, looping client input
signal on the client output port.
The loop is located on the client
transceiver <Help> This maintenance
parameter opera…
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.2.16.1.2
.1.3.6.1.4.1.20044.38.6.2.18 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlportOosModeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlportOosModeTable'
List of pm1004vdcCtrlportOosMode 
Article
pm1004vdcCtrlportOosModeEntry row .1.3.6.1.4.1.20044.38.6.2.18.1
Row definition for the pm1004vdcCtrlportOosMode
table
Column Syntax OID
Index definition for the pm1004vdcCtrlportOosMode
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.18.1.1
Client Out Of Service :This OID
sets the Service state of the client
port (In Service, Tx Out of Service,
Rx Out of Service or Port (Rx and
Tx) Out of Service) <Help> This
controls defines the service state
of t…
Pm1004vdcClientOosModer/w
Type Values:
0clientportis
1clienttxoos
2clientrxoos
3clientportoos
Description:
Mode for OOS on client ports
.1.3.6.1.4.1.20044.38.6.2.18.1.2
.1.3.6.1.4.1.20044.38.6.2.20 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlsfpOffCtrlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlsfpOffCtrlTable'
List of pm1004vdcCtrlsfpOffCtrl 
Article
pm1004vdcCtrlsfpOffCtrlEntry row .1.3.6.1.4.1.20044.38.6.2.20.1
Row definition for the pm1004vdcCtrlsfpOffCtrl
table
Column Syntax OID
Index definition for the pm1004vdcCtrlsfpOffCtrl
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.20.1.1
Signal OFF :This OID switches
off the SFP. <Help> This control
defines the laser state of the
client transceiver
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.2.20.1.2
.1.3.6.1.4.1.20044.38.6.2.21 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlcsfUpInsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlcsfUpInsTable'
List of pm1004vdcCtrlcsfUpIns
Article
pm1004vdcCtrlcsfUpInsEntry row .1.3.6.1.4.1.20044.38.6.2.21.1
Row definition for the pm1004vdcCtrlcsfUpIns
table
Column Syntax OID
Index definition for the pm1004vdcCtrlcsfUpIns
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.21.1.1
Client Signal Fail Insertion :This
OID, when set, inserts a client
signal fail in the upstream client
Port. <Help> This control inserts
a Client Signal Fail for the client
port
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.2.21.1.2
.1.3.6.1.4.1.20044.38.6.2.22 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlcaisDwInsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlcaisDwInsTable'
List of pm1004vdcCtrlcaisDwIns 
Article
pm1004vdcCtrlcaisDwInsEntry row .1.3.6.1.4.1.20044.38.6.2.22.1
Row definition for the pm1004vdcCtrlcaisDwIns
table
Column Syntax OID
Index definition for the pm1004vdcCtrlcaisDwIns
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.22.1.1
Client AIS Insertion :This OID,
when set, inserts a client AIS
on the downstream client Port.
<Help> This control inserts a
Client AIS for the client port
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.2.22.1.2
.1.3.6.1.4.1.20044.38.6.2.26 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlclientAccessTermLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlclientAccessTermLoopTable'
List of pm1004vdcCtrlclientAccessTermLoop 
Article
pm1004vdcCtrlclientAccessTermLoopEntry row .1.3.6.1.4.1.20044.38.6.2.26.1
Row definition for the pm1004vdcCtrlclientAccessTermLoop
table
Column Syntax OID
Index definition for the pm1004vdcCtrlclientAccessTermLoop
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.26.1.1
Client Terminal Loopback :This
OID operates a Client Terminal
Loopback, looping client input
signal on the client output port.
The loop is located on the line
transceiver <Help> This maintenance
parameter operate…
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.2.26.1.2
.1.3.6.1.4.1.20044.38.6.2.43 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlrxVideoProtocolTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlrxVideoProtocolTable'
List of pm1004vdcCtrlrxVideoProtocol 
Article
pm1004vdcCtrlrxVideoProtocolEntry row .1.3.6.1.4.1.20044.38.6.2.43.1
Row definition for the pm1004vdcCtrlrxVideoProtocol
table
Column Syntax OID
Index definition for the pm1004vdcCtrlrxVideoProtocol
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.43.1.1
Force DVB ASI On RX Side
:This
OID selects the DVB ASI protocol
on the client port and disable
the auto-sensing feature
<Help>
This control selects the DVB ASI
protocol on the client port and
disable the auto-sen…
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.2.43.1.2
.1.3.6.1.4.1.20044.38.6.2.128 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrladddropClientRxProtectTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrladddropClientRxProtectTable'
List of pm1004vdcCtrladddropClientRxProtect 
Article
pm1004vdcCtrladddropClientRxProtectEntry row .1.3.6.1.4.1.20044.38.6.2.128.1
Row definition for the pm1004vdcCtrladddropClientRxProtect
table
Column Syntax OID
Index definition for the pm1004vdcCtrladddropClientRxProtect
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.128.1.1
Client Switch Mode :This bit selects
the manual (1) or automatic (0)
switch method <Help> This control
defines the protection switch mode
on the client interface
Pm1004vdcProtectionTimeSlotr/w
Type Values:
0auto
257manualX2Line2
513manualX1Line1
Description:
protection for control
.1.3.6.1.4.1.20044.38.6.2.128.1.2
.1.3.6.1.4.1.20044.38.6.2.136 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrladddropTsClientModeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrladddropTsClientModeTable'
List of pm1004vdcCtrladddropTsClientMode 
Article
pm1004vdcCtrladddropTsClientModeEntry row .1.3.6.1.4.1.20044.38.6.2.136.1
Row definition for the pm1004vdcCtrladddropTsClientMode
table
Column Syntax OID
Index definition for the pm1004vdcCtrladddropTsClientMode
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.2.136.1.1
Client Mode :This OID selects
the mode on the client <Help>
This control defines the mode
(Add/Drop or Split&Select) of the
Client
Pm1004vdcModeTimeSlotr/w
Type Values:
256singleSplitSelect
Description:
different mode for time slot
.1.3.6.1.4.1.20044.38.6.2.136.1.2
.1.3.6.1.4.1.20044.38.6.3.74 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrllineOosModeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrllineOosModeTable'
List of pm1004vdcCtrllineOosMode 
Article
pm1004vdcCtrllineOosModeEntry row .1.3.6.1.4.1.20044.38.6.3.74.1
Row definition for the pm1004vdcCtrllineOosMode
table
Column Syntax OID
Index definition for the pm1004vdcCtrllineOosMode
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.3.74.1.1
Line Out Of Service (!Laser OFF!)
:This OID sets the line port Out
Of Service <Help> This control
defines the service state of the
line port
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.3.74.1.2
.1.3.6.1.4.1.20044.38.6.3.198 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrldccEnableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrldccEnableTable'
List of pm1004vdcCtrldccEnable 
Article
pm1004vdcCtrldccEnableEntry row .1.3.6.1.4.1.20044.38.6.3.198.1
Row definition for the pm1004vdcCtrldccEnable
table
Column Syntax OID
Index definition for the pm1004vdcCtrldccEnable
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.3.198.1.1
DCC Mode : This OID enables the
DCC mode on the PM <Help> This
control enables the DCC mode on
the PM
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.3.198.1.2
.1.3.6.1.4.1.20044.38.6.3.208 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlxfpOnoffTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlxfpOnoffTable'
List of pm1004vdcCtrlxfpOnoff
Article
pm1004vdcCtrlxfpOnoffEntry row .1.3.6.1.4.1.20044.38.6.3.208.1
Row definition for the pm1004vdcCtrlxfpOnoff
table
Column Syntax OID
Index definition for the pm1004vdcCtrlxfpOnoff
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.3.208.1.1
XFP/OTX Optical Laser OFF :This
OID switches off the XFP or the
OTX <Help> This control defines
the laser state of the line transceiver
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.3.208.1.2
.1.3.6.1.4.1.20044.38.6.3.209 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlxfpLineLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlxfpLineLoopTable'
List of pm1004vdcCtrlxfpLineLoop 
Article
pm1004vdcCtrlxfpLineLoopEntry row .1.3.6.1.4.1.20044.38.6.3.209.1
Row definition for the pm1004vdcCtrlxfpLineLoop
table
Column Syntax OID
Index definition for the pm1004vdcCtrlxfpLineLoop
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.3.209.1.1
Line Facility Loopback :This OID
operates a Line Facility Loopback,
looping line input signal on the
line output port. The loop is located
on the line transceiver. If the
Line signal carries DCC, the management
ne…
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.3.209.1.2
.1.3.6.1.4.1.20044.38.6.3.210 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCtrlxfpXfiLoopTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCtrlxfpXfiLoopTable'
List of pm1004vdcCtrlxfpXfiLoop 
Article
pm1004vdcCtrlxfpXfiLoopEntry row .1.3.6.1.4.1.20044.38.6.3.210.1
Row definition for the pm1004vdcCtrlxfpXfiLoop
table
Column Syntax OID
Index definition for the pm1004vdcCtrlxfpXfiLoop
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.6.3.210.1.1
Line Terminal Loopback :This OID
operates a Line Terminal Loopback,
looping line input signal on the
line output port. The loop is located
on all client transceivers <Help>
This maintenance parameter operates
a L…
EKINOPS-MIBEkiStater/w
Type Values:
1disabled
2enabled
.1.3.6.1.4.1.20044.38.6.3.210.1.2
.1.3.6.1.4.1.20044.38.7.1.1 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcRinvSfpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcRinvSfpTable'
List of the SFPs on the selected module
pm1004vdcRinvSfpEntry row .1.3.6.1.4.1.20044.38.7.1.1.1
Row definition for the SFP table
Column Syntax OID
Index for SFP table
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.20044.38.7.1.1.1.1
Inventory for the SFP: This OID contains the inventory for the SFP
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.20044.38.7.1.1.1.2
.1.3.6.1.4.1.20044.38.7.1.2 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcRinvLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcRinvLineTable'
List of the XFPs on the selected module
pm1004vdcRinvLineEntry row .1.3.6.1.4.1.20044.38.7.1.2.1
Row definition for the XFP table
Column Syntax OID
Index for XFP table
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.20044.38.7.1.2.1.1
Inventory for the XFP: This OID contains the inventory for the XFP
SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.20044.38.7.1.2.1.2
.1.3.6.1.4.1.20044.38.9.1.1 · 1 row entry · 8 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgClientcaiscsfTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgClientcaiscsfTable'
List of  Article
pm1004vdcCfgClientcaiscsfEntry row .1.3.6.1.4.1.20044.38.9.1.1.1
Row definition for the accessCAisCsf
table
Column Syntax OID
Index definition for the clientcaiscsf
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.1.1.1.1
CAIS mode on Client Port :This
register enables/disables port
laser shutdown on CAIS insertion
condition
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.3
CSF contributors on Client Port
:This register configures the contributors
to upstream CSF insertion on the
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.9
CSF contributors on Client Port
:This register configures the contributors
to upstream CSF insertion on the
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.10
CAIS contributors on Client Port
:This register configures the contributors
to downstream CAIS insertion on
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.17
CAIS contributors on Client Port
:This register configures the contributors
to downstream CAIS insertion on
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.18
CAIS contributors on Client Port
:This register configures the contributors
to downstream CAIS insertion on
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.19
CAIS contributors on Client Port
:This register configures the contributors
to downstream CAIS insertion on
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.1.1.1.20
.1.3.6.1.4.1.20044.38.9.2.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgClientStartupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgClientStartupTable'
List of  Article
pm1004vdcCfgClientStartupEntry row .1.3.6.1.4.1.20044.38.9.2.1.1
Row definition for the startup
table
Column Syntax OID
Index definition for the clientStartup
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.2.1.1.1
Default Settings on Client Port
:This register configures the
default initialisation settings
on the port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.2.1.1.3
Default Protocol on Client Port
:This register configures the default
initialisation protocol on the
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.2.1.1.4
Default Add&Drop mode on Client
Port :This register configures
the default Add&Drop mode on the
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.2.1.1.5
.1.3.6.1.4.1.20044.38.9.2.3 · 1 row entry · 3 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgXfpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgXfpTable'
List of  Article
pm1004vdcCfgXfpEntry row .1.3.6.1.4.1.20044.38.9.2.3.1
Row definition for the startup
table
Column Syntax OID
Index definition for the xfp table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.2.3.1.1
Default settings on XFP Port :This
register configures the default
initialisation settings on XFP
port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.2.3.1.3
:
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.2.3.1.4
.1.3.6.1.4.1.20044.38.9.3.1 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgLabelclientTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgLabelclientTable'
List of  Article
pm1004vdcCfgLabelclientEntry row .1.3.6.1.4.1.20044.38.9.3.1.1
Row definition for the labels
table
Column Syntax OID
Index definition for the labelclient
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.3.1.1.1
Default settings on the label
of the Ports :These registers
configures the default initialisation
settings of the labels of the ports.
SNMPv2-TCDisplayStringr/w
Constraints:
range: 1-16
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.20044.38.9.3.1.1.3
.1.3.6.1.4.1.20044.38.9.3.2 · 1 row entry · 2 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgLabellineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgLabellineTable'
List of  Article
pm1004vdcCfgLabellineEntry row .1.3.6.1.4.1.20044.38.9.3.2.1
Row definition for the labels
table
Column Syntax OID
Index definition for the labelline
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.3.2.1.1
Default settings on the label
of the lines :These registers
configures the default initialisation
settings of the labels of the lines.
SNMPv2-TCDisplayStringr/w
Constraints:
range: 1-16
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.20044.38.9.3.2.1.3
.1.3.6.1.4.1.20044.38.9.4.1 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgClientStartupThreshTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgClientStartupThreshTable'
List of  Article
pm1004vdcCfgClientStartupThreshEntry row .1.3.6.1.4.1.20044.38.9.4.1.1
Row definition for the startupthresholds
table
Column Syntax OID
Index definition for the clientStartupThresh
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.4.1.1.1
Default Setting on Tx Power high
threshold :This register configures
the default initialisation of the
high threshold of the Transmit
power on the port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.1.1.15
Default Setting on Tx Power low
threshold :This register configures
the default initialisation of the
low threshold of the Transmit power
on the port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.1.1.16
Default Setting on Rx Power high
threshold :This register configures
the default initialisation of the
high threshold of the received
power on the port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.1.1.19
Default Setting on Rx Power low
threshold :This register configures
the default initialisation of the
low threshold of the received power
on the port.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.1.1.20
.1.3.6.1.4.1.20044.38.9.4.2 · 1 row entry · 5 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgLineStartupThreshTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgLineStartupThreshTable'
List of  Article
pm1004vdcCfgLineStartupThreshEntry row .1.3.6.1.4.1.20044.38.9.4.2.1
Row definition for the startupthresholds
table
Column Syntax OID
Index definition for the lineStartupThresh
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.4.2.1.1
Default Setting on Tx Power high
threshold :This register configures
the default initialisation of the
high threshold of the Transmit
power on the line.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.2.1.15
Default Setting on Tx Power low
threshold :This register configures
the default initialisation of the
low threshold of the Transmit power
on the line.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.2.1.16
Default Setting on Rx Power high
threshold :This register configures
the default initialisation of the
high threshold of the received
power on the line.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.2.1.19
Default Setting on Rx Power low
threshold :This register configures
the default initialisation of the
low threshold of the received power
on the line.
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.4.2.1.20
.1.3.6.1.4.1.20044.38.9.5.1 · 1 row entry · 11 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgOtxtlhTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgOtxtlhTable'
List of  Article
pm1004vdcCfgOtxtlhEntry row .1.3.6.1.4.1.20044.38.9.5.1.1
Row definition for the startuptlh
table
Column Syntax OID
Index definition for the otxtlh
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.5.1.1.1
:
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.3
Default Line OTX TLH FM amplitude
:This register configures the start-up
width of the frequency modulation
of the Line OTX TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.4
Default Line OTX TLH FM frequency
:This register configures the start-up
frequency of the frequency modulation
of the Line OTX TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.5
Defaut Line OTX TLH output Power
:This register configures the start-up
output power of the Line OTX TLH
(Unit = dBm)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.6
Default Line OTX TLH Channel :This
register configures the start-up
laser channel of the Line OTX TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.7
Default Line OTX TLH Grid :This
register configures the start-up
laser grid of the Line OTX TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.8
Default Line OTX TLH lowest Freq
:This register configures the start-up
lowest frequency supported on the
Line OTX TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.9
:
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.10
Default Line OTX TLH APD mode
:This register configures the
start-up APD mode of the Line
OTX TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.11
Default Line OTX TLH APD atten.
:This register configures the start-up
APD attenuation on the Line OTX
TLH
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.5.1.1.12
.1.3.6.1.4.1.20044.38.9.6.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgSlotslineaddtx1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgSlotslineaddtx1Table'
List of  Article
pm1004vdcCfgSlotslineaddtx1Entry row .1.3.6.1.4.1.20044.38.9.6.1.1
Row definition for the startupslotslineaddtx1
table
Column Syntax OID
Index definition for the slotslineaddtx1
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.6.1.1.1
Port Defaut Add Slot allocation
(MSB) on Line1 :This register configures
the start-up slots allocation on
the port (MSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.6.1.1.3
Port Defaut Add Slot allocation
(LSB) on Line1 :This register configures
the start-up slots allocation on
the port (LSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.6.1.1.4
Port Defaut Protocol on Line1
:This register configures the
start-up protocol on the port
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.6.1.1.5
.1.3.6.1.4.1.20044.38.9.7.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgSlotslineaddtx2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgSlotslineaddtx2Table'
List of  Article
pm1004vdcCfgSlotslineaddtx2Entry row .1.3.6.1.4.1.20044.38.9.7.1.1
Row definition for the startupslotslineaddtx2
table
Column Syntax OID
Index definition for the slotslineaddtx2
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.7.1.1.1
Port Defaut Add Slot allocation
(MSB) on Line2 :This register configures
the start-up slots allocation on
the port (MSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.7.1.1.3
Port Defaut Add Slot allocation
(LSB) on Line2 :This register configures
the start-up slots allocation on
the port (LSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.7.1.1.4
Port Defaut Protocol on Line2
:This register configures the
start-up protocol on the port
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.7.1.1.5
.1.3.6.1.4.1.20044.38.9.8.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgSlotslinepassthroughtx1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgSlotslinepassthroughtx1Table'
List of  Article
pm1004vdcCfgSlotslinepassthroughtx1Entry row .1.3.6.1.4.1.20044.38.9.8.1.1
Row definition for the startupslotslinepassthroughtx1
table
Column Syntax OID
Index definition for the slotslinepassthroughtx1
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.8.1.1.1
Port Defaut PassThrough Slot
allocation (MSB) on Line1 :This
register configures the start-up
slots allocation on the port (MSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.8.1.1.3
Port Defaut PassThrough Slot allocation
(LSB) on Line1 :This register configures
the start-up slots allocation on
the port (LSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.8.1.1.4
Port Defaut PassThrough Protocol
on Line1 :This register configures
the start-up protocol on the port
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.8.1.1.5
.1.3.6.1.4.1.20044.38.9.9.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgSlotslinepassthroughtx2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgSlotslinepassthroughtx2Table'
List of  Article
pm1004vdcCfgSlotslinepassthroughtx2Entry row .1.3.6.1.4.1.20044.38.9.9.1.1
Row definition for the startupslotslinepassthroughtx2
table
Column Syntax OID
Index definition for the slotslinepassthroughtx2
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.9.1.1.1
Port Defaut PassThrough Slot
allocation (MSB) on Line2 :This
register configures the start-up
slots allocation on the port (MSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.9.1.1.3
Port Defaut PassThrough Slot allocation
(LSB) on Line2 :This register configures
the start-up slots allocation on
the port (LSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.9.1.1.4
Port Defaut PassThrough Protocol
on Line2 :This register configures
the start-up protocol on the port
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.9.1.1.5
.1.3.6.1.4.1.20044.38.9.10.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgSlotslinedroprx1Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgSlotslinedroprx1Table'
List of  Article
pm1004vdcCfgSlotslinedroprx1Entry row .1.3.6.1.4.1.20044.38.9.10.1.1
Row definition for the startupslotslinedroprx1
table
Column Syntax OID
Index definition for the slotslinedroprx1
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.10.1.1.1
Port Defaut Drop Slot allocation
(MSB) on Line1 :This register configures
the start-up slots allocation on
the port (MSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.10.1.1.3
Port Defaut Drop Slot allocation
(LSB) on Line1 :This register configures
the start-up slots allocation on
the port (LSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.10.1.1.4
Port Defaut Protocol on Line1
:This register configures the
start-up protocol on the port
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.10.1.1.5
.1.3.6.1.4.1.20044.38.9.11.1 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgSlotslinedroprx2Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgSlotslinedroprx2Table'
List of  Article
pm1004vdcCfgSlotslinedroprx2Entry row .1.3.6.1.4.1.20044.38.9.11.1.1
Row definition for the startupslotslineaddrx2
table
Column Syntax OID
Index definition for the slotslinedroprx2
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.11.1.1.1
Port Defaut Drop Slot allocation
(MSB) on Line2 :This register configures
the start-up slots allocation on
the port (MSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.11.1.1.3
Port Defaut Drop Slot allocation
(LSB) on Line2 :This register configures
the start-up slots allocation on
the port (LSB)
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.11.1.1.4
Port Defaut Protocol on Line2
:This register configures the
start-up protocol on the port
Unsigned32r/w
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.11.1.1.5
.1.3.6.1.4.1.20044.38.9.13.1 · 1 row entry · 6 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcCfgOtxtlhcapabilitiesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcCfgOtxtlhcapabilitiesTable'
List of  Article
pm1004vdcCfgOtxtlhcapabilitiesEntry row .1.3.6.1.4.1.20044.38.9.13.1.1
Row definition for the startuptablefive
table
Column Syntax OID
Index definition for the otxtlhcapabilities
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.9.13.1.1.1
Component parameters :This OID
defines the component parameters
Unsigned32
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.13.1.1.3
Miscellaneous default settings
:This OID defines the miscellaneous
parameters
Unsigned32
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.13.1.1.4
Number of the first channel of
the component :This OID defines
the first channel number of the
PM
Unsigned32
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.13.1.1.5
Number of the last channel of
the component :This OID defines
the last channel number of the
PM
Unsigned32
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.13.1.1.6
Grid value of the component :This
OID defines the grid of the PM
Unsigned32
Constraints:
range: 0-65536
.1.3.6.1.4.1.20044.38.9.13.1.1.7
.1.3.6.1.4.1.20044.38.11.2.4.16 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupRmonByteCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupRmonByteCntTable'
List of pm1004vdcMonupRmonByteCnt 
Article
pm1004vdcMonupRmonByteCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.16.1
Row definition for the pm1004vdcMonupRmonByteCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupRmonByteCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.16.1.1
Client Input Bytes :This counter
is increased each time a data byte
is received on the client port
<Help> This counter gives the
number of bytes received on the
client port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.16.1.2
Bytes Counter Error :This OID
when set indicates the Bytes counter
value is invalid on clinet port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.16.1.3
Bytes Counter Overload :This OID
when set indicates a Bytes counter
overload on client port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.16.1.4
.1.3.6.1.4.1.20044.38.11.2.4.24 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupRmonCrcErrorCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupRmonCrcErrorCntTable'
List of pm1004vdcMonupRmonCrcErrorCnt 
Article
pm1004vdcMonupRmonCrcErrorCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.24.1
Row definition for the pm1004vdcMonupRmonCrcErrorCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupRmonCrcErrorCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.24.1.1
Client Input CRC Errors :This
counter is increased each time
a CRC error is detected on the
client port <Help> This counter
gives the number of CRC Errors
received on the client port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.24.1.2
CRC Errors Counter Error :This
OID when set indicates the CRC
Errors counter value is invalid
on clinet port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.24.1.3
CRC Errors Counter Overload :This
OID when set indicates a CRC Errors
counter overload on client port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.24.1.4
.1.3.6.1.4.1.20044.38.11.2.4.32 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupRmonPacketsCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupRmonPacketsCntTable'
List of pm1004vdcMonupRmonPacketsCnt 
Article
pm1004vdcMonupRmonPacketsCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.32.1
Row definition for the pm1004vdcMonupRmonPacketsCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupRmonPacketsCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.32.1.1
Client Input Packets :This counter
is increased each time a packet
is received on the client port
<Help> This counter gives the
number of packets received on the
client port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.32.1.2
Packets Counter Error :This OID
when set indicates the Packets
counter value is invalid on clinet
port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.32.1.3
Packets Counter Overload :This
OID when set indicates a Packets
counter overload on client port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.32.1.4
.1.3.6.1.4.1.20044.38.11.2.4.40 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupRmonBroadcastCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupRmonBroadcastCntTable'
List of pm1004vdcMonupRmonBroadcastCnt 
Article
pm1004vdcMonupRmonBroadcastCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.40.1
Row definition for the pm1004vdcMonupRmonBroadcastCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupRmonBroadcastCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.40.1.1
Client Input Broadcast Packets
:This counter is increased each
time a broadcast packet is received
on the client port <Help> This
counter gives the number of Broadcast
packets received on the client
port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.40.1.2
Broadcast Counter Error :This
OID when set indicates the Broadcast
counter value is invalid on clinet
port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.40.1.3
Broadcast Counter Overload :This
OID when set indicates a Broadcast
counter overload on client port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.40.1.4
.1.3.6.1.4.1.20044.38.11.2.4.48 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupRmonMulticastCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupRmonMulticastCntTable'
List of pm1004vdcMonupRmonMulticastCnt 
Article
pm1004vdcMonupRmonMulticastCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.48.1
Row definition for the pm1004vdcMonupRmonMulticastCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupRmonMulticastCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.48.1.1
Client Input Multicast Packets
:This counter is increased each
time a Multicast packet is received
on the client port <Help> This
counter gives the number of Multicast
packets received on the client
port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.48.1.2
Multicast Counter Error :This
OID when set indicates the Multicast
counter value is invalid on clinet
port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.48.1.3
Multicast Counter Overload :This
OID when set indicates a Multicast
counter overload on client port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.48.1.4
.1.3.6.1.4.1.20044.38.11.2.4.208 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupLineRmonByteCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupLineRmonByteCntTable'
List of pm1004vdcMonupLineRmonByteCnt 
Article
pm1004vdcMonupLineRmonByteCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.208.1
Row definition for the pm1004vdcMonupLineRmonByteCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupLineRmonByteCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.208.1.1
Line Input Bytes :This counter
is increased each time a data byte
is received on the Line port <Help>
This counter gives the number
of bytes received on the Line
port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.208.1.2
Bytes Counter Error :This OID
when set indicates the Bytes counter
value is invalid on line port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.208.1.3
Bytes Counter Overload :This OID
when set indicates a Bytes counter
overload on line port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.208.1.4
.1.3.6.1.4.1.20044.38.11.2.4.209 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupLineRmonCrcErrorCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupLineRmonCrcErrorCntTable'
List of pm1004vdcMonupLineRmonCrcErrorCnt 
Article
pm1004vdcMonupLineRmonCrcErrorCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.209.1
Row definition for the pm1004vdcMonupLineRmonCrcErrorCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupLineRmonCrcErrorCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.209.1.1
Line Input CRC Errors :This counter
is increased each time a CRC error
is detected on the Line port <Help>
This counter gives the number
of CRC Errors received on the
Line port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.209.1.2
CRC Errors Counter Error :This
OID when set indicates the CRC
Errors counter value is invalid
on line port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.209.1.3
CRC Errors Counter Overload :This
OID when set indicates a CRC Errors
counter overload on line port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.209.1.4
.1.3.6.1.4.1.20044.38.11.2.4.210 · 1 row entry · 4 columns
Uses the ekinops variant from /opt/observium/mibs/ekinops.
Command help
Walk pm1004vdcMonupLineRmonPacketsCntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EKINOPS-Pm1004VDC-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm1004VDC-MIB::pm1004vdcMonupLineRmonPacketsCntTable'
List of pm1004vdcMonupLineRmonPacketsCnt 
Article
pm1004vdcMonupLineRmonPacketsCntEntry row .1.3.6.1.4.1.20044.38.11.2.4.210.1
Row definition for the pm1004vdcMonupLineRmonPacketsCnt
table
Column Syntax OID
Index definition for the pm1004vdcMonupLineRmonPacketsCnt
table
Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.20044.38.11.2.4.210.1.1
Line Input Packets :This counter
is increased each time a packet
is received on the Line port <Help>
This counter gives the number
of packets received on the Line
port
SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.20044.38.11.2.4.210.1.2
Packets Counter Error :This OID
when set indicates the Packets
counter value is invalid on client
port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.210.1.3
Packets Counter Overload :This
OID when set indicates a Packets
counter overload on line port
EKINOPS-MIBEkiOnOff
Type Values:
1off
2on
.1.3.6.1.4.1.20044.38.11.2.4.210.1.4