EGNITEPHYSENSOR-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
10
querxPhySensorTable
table.1.3.6.1.4.1.3444.1.14.1.2
·
1 row entry
·
10 columns
Uses the egnite variant from
Command help
/opt/observium/mibs/egnite.
Walk querxPhySensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EGNITEPHYSENSOR-MIB' -M '/opt/observium/mibs/egnite:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EGNITEPHYSENSOR-MIB::querxPhySensorTable'
This table contains one row per physical sensor.
Information about a particular physical sensor.
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are cre…
An entry in this table describes the present reading of a
sensor, the measurement units and scale, and sensor
operational status.
Entries are cre…
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| querxPhySensorIndexA unique value, greater than zero, for each sensor. | QuerxSensorIndex Type Constraints: range: 1..2147483647 | .1.3.6.1.4.1.3444.1.14.1.2.1.1 | ||||||||||||||||||||||||||||||||||
| querxPhySensorTypeThe type of data returned by the associated querxPhySensorValue object. This object SHOULD be set by the agent during entry creation, and the value SHOULD NOT change during operation. | QuerxSensorDataType Type Values:
| .1.3.6.1.4.1.3444.1.14.1.2.1.2 | ||||||||||||||||||||||||||||||||||
| querxPhySensorScaleThe exponent to apply to values returned by the associated querxPhySensorValue object. | QuerxSensorDataScale Type Values:
| .1.3.6.1.4.1.3444.1.14.1.2.1.3 | ||||||||||||||||||||||||||||||||||
| querxPhySensorPrecisionThe number of decimal places of precision in fixed-point sensor values returned by the associated querxPhySensorValue object. This object SHOULD be set to '0' when the associated querxPhySensorType value … | QuerxSensorPrecision Type Constraints: range: -8..9 | .1.3.6.1.4.1.3444.1.14.1.2.1.4 | ||||||||||||||||||||||||||||||||||
| querxPhySensorValueThe most recent measurement obtained by the agent for this sensor. To correctly interpret the value of this object, the associated querxPhySensorType, querxPhySensorScale, and querxPhySensorPrecision obje… | QuerxSensorValue Type Constraints: range: -1000000000..1000000000 | .1.3.6.1.4.1.3444.1.14.1.2.1.5 | ||||||||||||||||||||||||||||||||||
| querxPhySensorOperStatusThe operational status of the sensor. | QuerxSensorStatus Type Values:
| .1.3.6.1.4.1.3444.1.14.1.2.1.6 | ||||||||||||||||||||||||||||||||||
| querxPhySensorUnitsDisplayA textual description of the data units that should be used in the display of querxPhySensorValue. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.3444.1.14.1.2.1.7 | ||||||||||||||||||||||||||||||||||
| querxPhySensorValueTimeStampThe value of sysUpTime at the time the status and/or value of this sensor was last obtained by the agent. | .1.3.6.1.4.1.3444.1.14.1.2.1.8 | |||||||||||||||||||||||||||||||||||
| querxPhySensorValueUpdateRateAn indication of the frequency that the agent updates the associated querxPhySensorValue object, representing in milliseconds. The value zero indicates: - the sensor value is updated on… | millisecondsSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.3444.1.14.1.2.1.9 | ||||||||||||||||||||||||||||||||||
| querxPhySensorNameThe textual name of the physical sensor. If there is no local name, or if this object is otherwise not applicable, then this object contains a zero-length string. | OctetString Constraints: range: 0-31 | .1.3.6.1.4.1.3444.1.14.1.2.1.10 |