EES-POWER-MIB
Download MIB
Monitored by Observium
Vertiv Tech Co. Ltd. Power MIB, revision E.
Observium actively monitors this MIB
Visit Observium
Observium uses this MIB in discovery or polling workflows on applicable devices.
Device identity
Sensors
Status
- Source file
EES-POWER-MIB- Last revised
- Identity
powerMIB- Base OID
1.3.6.1.4.1.6302.2.1- Objects
- 119 scalars · 126 columns
- Tables
- 13 tables
Net-SNMP examples using the vertiv MIB directory
These commands use the standard Observium installation path and load the selected MIB variant before the RFC and Net-SNMP directories.
Translate the module identity
/usr/bin/snmptranslate -Pud -Ir -On -m 'EES-POWER-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EES-POWER-MIB::powerMIB'
Walk the MIB subtree
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'EES-POWER-MIB' -M '/opt/observium/mibs/vertiv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EES-POWER-MIB::powerMIB'
Imported Objects
| SNMPv2-SMI | Counter32 enterprises Integer32 MODULE-IDENTITY (no object page) NOTIFICATION-TYPE (no object page) OBJECT-TYPE (no object page) |
| SNMPv2-TC | DateAndTime DisplayString TEXTUAL-CONVENTION (no object page) |
Showing 297 of 297 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link directly to their definitions on this MIB page. Hover or focus a linked name or badge for more details.
.1.3.6.1.4.1.6302 | ||
.1.3.6.1.4.1.6302.2 | ||
| powerMIB | .1.3.6.1.4.1.6302.2.1 | |
.1.3.6.1.4.1.6302.2.1.1 | ||
| identManufacturer | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.1.1 |
| identModel | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.1.2 |
| identControllerFirmwareVersionOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.1.3 |
identNamer/w | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.1.4 |
| identSNMPCfgVer | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.1.5 |
| identControllerSerialNumberOBS ✓ | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.1.6 |
.1.3.6.1.4.1.6302.2.1.2 | ||
| systemStatusOBS ✓ | Status | .1.3.6.1.4.1.6302.2.1.2.1 |
.1.3.6.1.4.1.6302.2.1.2.10 | ||
| psSMACNumber | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.10.1 |
| psSMBATNumber | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.10.2 |
| psSMIONumber | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.10.3 |
.1.3.6.1.4.1.6302.2.1.2.11 | ||
| numberOfInstalledRectifiers | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.1 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.10 | |
| psACEnergyOfRectifiers | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.11 |
| psDCEnergyOfRectifiers | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.12 |
| numberOfRectifiersCommunicating | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.2 |
| rectifiersUsedCapacityOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.3 |
| psRectifierTable | .1.3.6.1.4.1.6302.2.1.2.11.4 | |
| psRectifierEntry | .1.3.6.1.4.1.6302.2.1.2.11.4.1 | |
| psRectifierIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.11.4.1.1 |
| psRectifierProductNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.11.4.1.2 |
| psRectifierHWVersion | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.11.4.1.3 |
| psRectifierSWVersion | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.11.4.1.4 |
| psRectifierSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.11.4.1.5 |
| psRectifierCurrentOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.4.1.6 |
| psRectifierIdent | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.11.4.1.7 |
| psRectifierFailOBS ✓ | StatusChange | .1.3.6.1.4.1.6302.2.1.2.11.4.1.8 |
| psRectifierTemperatureOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.4.1.9 |
| psPowerOfRectifiers | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.5 |
| psOverOutputVoltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.7 |
| psVeryOverOutputVoltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.11.8 |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.11.9 | |
.1.3.6.1.4.1.6302.2.1.2.12 | ||
| psTotalLoadCurrentOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.12.1 |
| psDistributionLoadTable | .1.3.6.1.4.1.6302.2.1.2.12.2 | |
| psDistributionLoadEntry | .1.3.6.1.4.1.6302.2.1.2.12.2.1 | |
| psDistributionLoadIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.12.2.1.1 |
| psDistributionLoadCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.12.2.1.2 |
| psDistributionLoadName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.12.2.1.3 |
| psDistributionGeneralTable | .1.3.6.1.4.1.6302.2.1.2.12.3 | |
| psDistributionGeneralEntry | .1.3.6.1.4.1.6302.2.1.2.12.3.1 | |
| psDistributionGeneralIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.12.3.1.1 |
| psDistributionGeneralCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.12.3.1.2 |
| psDistributionGeneralName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.12.3.1.3 |
.1.3.6.1.4.1.6302.2.1.2.13 | ||
| numberOfInstalledConverters | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.13.1 |
| numberOfConvertersCommunicating | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.13.2 |
| convertersUsedCapacity | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.13.3 |
| psConverterVoltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.13.4 |
| psTotalConverterCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.13.5 |
| psConverterTable | .1.3.6.1.4.1.6302.2.1.2.13.6 | |
| psConverterEntry | .1.3.6.1.4.1.6302.2.1.2.13.6.1 | |
| psConverterIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.13.6.1.1 |
| psConverterProductNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.13.6.1.2 |
| psConverterHWVersion | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.13.6.1.3 |
| psConverterSWVersion | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.13.6.1.4 |
| psConverterSerialNumber | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.13.6.1.5 |
| psConverterCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.13.6.1.6 |
| psConverterIdent | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.13.6.1.7 |
| psConverterFail | StatusChange | .1.3.6.1.4.1.6302.2.1.2.13.6.1.8 |
.1.3.6.1.4.1.6302.2.1.2.14 | ||
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.14.1 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.14.2 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.14.3 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.14.4 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.14.5 | |
| psEquipmentSignalTable | .1.3.6.1.4.1.6302.2.1.2.15 | |
| equipmentSignalTableEntry | .1.3.6.1.4.1.6302.2.1.2.15.1 | |
| psEquipmentSignalTableEntryIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.15.1.1 |
| psEquipmentSignalValue | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.15.1.2 |
| ambientTemperature | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.16 |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.17 | |
.1.3.6.1.4.1.6302.2.1.2.18 | ||
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.1 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.2 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.3 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.4 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.5 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.6 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.7 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.18.8 | |
.1.3.6.1.4.1.6302.2.1.2.19 | ||
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.19.1 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.19.2 | |
| systemVoltageOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.2 |
.1.3.6.1.4.1.6302.2.1.2.20 | ||
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.20.1 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.20.2 | |
.1.3.6.1.4.1.6302.2.1.2.21 | ||
| numberOfInstalledSMDUH | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.1 |
| psSMDUHCurrentTable | .1.3.6.1.4.1.6302.2.1.2.21.10 | |
| psSMDUHCurrentEntry | .1.3.6.1.4.1.6302.2.1.2.21.10.1 | |
| psSMDUHCurrentIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.1 |
| psSMDUHCurrent9 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.10 |
| psSMDUHCurrent10 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.11 |
| psSMDUHCurrent11 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.12 |
| psSMDUHCurrent12 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.13 |
| psSMDUHCurrent13 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.14 |
| psSMDUHCurrent14 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.15 |
| psSMDUHCurrent15 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.16 |
| psSMDUHCurrent16 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.17 |
| psSMDUHCurrent17 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.18 |
| psSMDUHCurrent18 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.19 |
| psSMDUHCurrent1 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.2 |
| psSMDUHCurrent19 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.20 |
| psSMDUHCurrent20 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.21 |
| psSMDUHCurrent2 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.3 |
| psSMDUHCurrent3 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.4 |
| psSMDUHCurrent4 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.5 |
| psSMDUHCurrent5 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.6 |
| psSMDUHCurrent6 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.7 |
| psSMDUHCurrent7 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.8 |
| psSMDUHCurrent8 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.10.1.9 |
| psSMDUH1Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.2 |
| psSMDUH2Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.3 |
| psSMDUH3Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.4 |
| psSMDUH4Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.5 |
| psSMDUH5Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.6 |
| psSMDUH6Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.7 |
| psSMDUH7Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.8 |
| psSMDUH8Voltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.21.9 |
.1.3.6.1.4.1.6302.2.1.2.22 | ||
| psSMDUHPowerTable | .1.3.6.1.4.1.6302.2.1.2.22.1 | |
| psSMDUHPowerEntry | .1.3.6.1.4.1.6302.2.1.2.22.1.1 | |
| psSMDUHPowerIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.1 |
| psSMDUHPower9 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.10 |
| psSMDUHPower10 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.11 |
| psSMDUHPower11 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.12 |
| psSMDUHPower12 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.13 |
| psSMDUHPower13 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.14 |
| psSMDUHPower14 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.15 |
| psSMDUHPower15 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.16 |
| psSMDUHPower16 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.17 |
| psSMDUHPower17 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.18 |
| psSMDUHPower18 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.19 |
| psSMDUHPower1 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.2 |
| psSMDUHPower19 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.20 |
| psSMDUHPower20 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.21 |
| psSMDUHPower2 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.3 |
| psSMDUHPower3 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.4 |
| psSMDUHPower4 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.5 |
| psSMDUHPower5 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.6 |
| psSMDUHPower6 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.7 |
| psSMDUHPower7 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.8 |
| psSMDUHPower8 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.22.1.1.9 |
.1.3.6.1.4.1.6302.2.1.2.23 | ||
| psSMDUHEnergyTable | .1.3.6.1.4.1.6302.2.1.2.23.1 | |
| psSMDUHEnergyEntry | .1.3.6.1.4.1.6302.2.1.2.23.1.1 | |
| psSMDUHEnergyIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.1 |
| psSMDUHTotalEnergy9 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.10 |
| psSMDUHTotalEnergy10 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.11 |
| psSMDUHTotalEnergy11 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.12 |
| psSMDUHTotalEnergy12 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.13 |
| psSMDUHTotalEnergy13 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.14 |
| psSMDUHTotalEnergy14 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.15 |
| psSMDUHTotalEnergy15 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.16 |
| psSMDUHTotalEnergy16 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.17 |
| psSMDUHTotalEnergy17 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.18 |
| psSMDUHTotalEnergy18 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.19 |
| psSMDUHTotalEnergy1 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.2 |
| psSMDUHTotalEnergy19 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.20 |
| psSMDUHTotalEnergy20 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.21 |
| psSMDUHTotalEnergy2 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.3 |
| psSMDUHTotalEnergy3 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.4 |
| psSMDUHTotalEnergy4 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.5 |
| psSMDUHTotalEnergy5 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.6 |
| psSMDUHTotalEnergy6 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.7 |
| psSMDUHTotalEnergy7 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.8 |
| psSMDUHTotalEnergy8 | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.23.1.1.9 |
.1.3.6.1.4.1.6302.2.1.2.24 | ||
| psSMDUTable | .1.3.6.1.4.1.6302.2.1.2.24.1 | |
| psSMDUEntry | .1.3.6.1.4.1.6302.2.1.2.24.1.1 | |
| psSMDUIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.1 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.10 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.11 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.12 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.13 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.14 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.15 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.16 | |
| psSMDULoad1Power | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.2 |
| psSMDULoad2Power | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.3 |
| psSMDULoad3Power | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.4 |
| psSMDULoad4Power | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.5 |
| psSMDULoad5Power | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.6 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.7 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.8 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.24.1.1.9 | |
.1.3.6.1.4.1.6302.2.1.2.25 | ||
| numberOfInstalledSolar | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.1 |
| numberOfSolarCommunicating | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.2 |
| solarsUsedCapacity | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.3 |
| psSolarTotalCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.4 |
| psSolarTotalPower | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.5 |
| psSolarTotalInputCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.6 |
| psSolarTotalInputPower | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.25.7 |
psSolarModer/w | Enumeration | .1.3.6.1.4.1.6302.2.1.2.25.8 |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.25.9 | |
.1.3.6.1.4.1.6302.2.1.2.26 | ||
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.1 | |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.10 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.11 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.12 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.13 | |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.14 | |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.15 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.2 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.3 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.4 | |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.5 | |
| Integer32 | .1.3.6.1.4.1.6302.2.1.2.26.6 | |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.26.7 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.8 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.26.9 | |
.1.3.6.1.4.1.6302.2.1.2.27 | ||
| psCabinetTable | .1.3.6.1.4.1.6302.2.1.2.27.1 | |
| psCabinetEntry | .1.3.6.1.4.1.6302.2.1.2.27.1.1 | |
| psCabinetIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.27.1.1.1 |
| psCabinetTotalCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.27.1.1.2 |
| psCabinetTotalPower | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.27.1.1.3 |
| psCabinetTotalEnergy | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.27.1.1.4 |
| psCabinetAlarmStatus | Enumeration | .1.3.6.1.4.1.6302.2.1.2.27.1.1.5 |
| systemCurrentOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.3 |
| systemUsedCapacityOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.4 |
.1.3.6.1.4.1.6302.2.1.2.5 | ||
| psBatteryVoltage | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.1 |
.1.3.6.1.4.1.6302.2.1.2.5.10 | ||
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.10.1 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.10.2 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.11 | |
| temperatureCompensation | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.12 |
| batt1RemainingCapacity | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.13 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.14 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.15 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.16 | |
| Integer32 | .1.3.6.1.4.1.6302.2.1.2.5.17 | |
| Enumeration | .1.3.6.1.4.1.6302.2.1.2.5.18 | |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.19 | |
| psTotalBatteryCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.2 |
| psBatteryAccumDischargeNarada | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.20 |
| psBatterySOHNarada | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.21 |
| psBatterySOHIncell | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.22 |
| psBatterySOHVision | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.23 |
| psBatterySOHNokia | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.24 |
| psLowestBatteryCapacity | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.3 |
| psBatteryNominalCapacity | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.4 |
| psBatteryTable | .1.3.6.1.4.1.6302.2.1.2.5.5 | |
| psBatteryEntry | .1.3.6.1.4.1.6302.2.1.2.5.5.1 | |
| psBatteryIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.5.5.1.1 |
| psBatteryCurrent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.5.1.2 |
| psBatteryName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.5.5.1.3 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.5.1.4 | |
| psBatteryCapacity | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.5.1.5 |
| psBatteryCapacityPercent | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.5.1.6 |
| numberOfBatteryStrings | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.6 |
| temperatureOfBattery | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.7 |
| SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.8 | |
.1.3.6.1.4.1.6302.2.1.2.5.9 | ||
floatVoltager/w | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.9.1 |
boostVoltager/w | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.5.9.2 |
.1.3.6.1.4.1.6302.2.1.2.6 | ||
| psInputLineAVoltageOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.1 |
| psInputLineBVoltageOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.2 |
| psInputLineCVoltageOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.3 |
| psInputPhaseACurrentOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.4 |
| psInputPhaseBCurrentOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.5 |
| psInputPhaseCCurrentOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.6 |
| psInputPowerCP | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.7 |
| psInputPowerDG | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.6.8 |
.1.3.6.1.4.1.6302.2.1.2.7 | ||
| psTemperature1OBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.7.1 |
| psTemperature2OBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.7.2 |
| psTemperatureTable | .1.3.6.1.4.1.6302.2.1.2.7.3 | |
| psTemperatureEntry | .1.3.6.1.4.1.6302.2.1.2.7.3.1 | |
| psTemperatureIndex | Integer32 | .1.3.6.1.4.1.6302.2.1.2.7.3.1.1 |
| psTemperatureMeasurementOBS ✓ | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.2.7.3.1.2 |
| psTemperatureName | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.2.7.3.1.3 |
| psTemperatureType | Enumeration | .1.3.6.1.4.1.6302.2.1.2.7.3.1.4 |
| psTemperatureAlarmStatus | Enumeration | .1.3.6.1.4.1.6302.2.1.2.7.3.1.5 |
| psStatusCommunication | Enumeration | .1.3.6.1.4.1.6302.2.1.2.8 |
| psStatusBatteryMode | Enumeration | .1.3.6.1.4.1.6302.2.1.2.9 |
| alarmLastTrapNo | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6302.2.1.3 |
| alarmActiveAlarmTable | .1.3.6.1.4.1.6302.2.1.4 | |
| activeAlarmEntry | .1.3.6.1.4.1.6302.2.1.4.1 | |
| alarmIndex | SNMPv2-SMICounter32 | .1.3.6.1.4.1.6302.2.1.4.1.1 |
| alarmTime | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.6302.2.1.4.1.2 |
| alarmStatusChange | StatusChange | .1.3.6.1.4.1.6302.2.1.4.1.3 |
| alarmSeverity | Status | .1.3.6.1.4.1.6302.2.1.4.1.4 |
| alarmDescription | SNMPv2-TCDisplayString | .1.3.6.1.4.1.6302.2.1.4.1.5 |
| alarmType | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.6302.2.1.4.1.6 |
.1.3.6.1.4.1.6302.2.1.5 |
Notifications / Traps (3)
| Notification | Variable bindings | OID |
|---|---|---|
| alarmTrap | .1.3.6.1.4.1.6302.2.1.5.1 | |
| alarmActiveTrap | .1.3.6.1.4.1.6302.2.1.5.2 | |
| alarmCeaseTrap | .1.3.6.1.4.1.6302.2.1.5.3 |
Type Definitions (2)
| Type | Syntax | Constraints |
|---|---|---|
| Status | Enumeration | 10 values |
| StatusChange | Enumeration | 2 values |
Dependencies (2) 2 direct Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- EES-POWER-MIBvertivselected