DeltaBMS-MIB

Monitored by Observium
Observium actively monitors this MIB
Observium uses this MIB in discovery or polling workflows on applicable devices.
Sensors Status
Explore Observium network monitoring
Source file
DeltaBMS-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises IpAddress TimeTicks
RFC1213-MIB DisplayString
Objects (53)
13 directly used by Observium
.1.3.6.1.4.1.2254
.1.3.6.1.4.1.2254.2
.1.3.6.1.4.1.2254.2.511
.1.3.6.1.4.1.2254.2.511.1
Integer32.1.3.6.1.4.1.2254.2.511.1.1
.1.3.6.1.4.1.2254.2.511.1.2
.1.3.6.1.4.1.2254.2.511.1.2.1
Integer32.1.3.6.1.4.1.2254.2.511.1.2.1.1
Integer32.1.3.6.1.4.1.2254.2.511.1.2.1.2
.1.3.6.1.4.1.2254.2.511.1.3
.1.3.6.1.4.1.2254.2.511.1.3.1
Integer32.1.3.6.1.4.1.2254.2.511.1.3.1.1
Integer32.1.3.6.1.4.1.2254.2.511.1.3.1.2
Integer32.1.3.6.1.4.1.2254.2.511.1.3.1.3
dbmsStringDCVoltageOBS ✓mandatory
0.1 VInteger32.1.3.6.1.4.1.2254.2.511.1.3.1.4
dbmsStringCurrentOBS ✓mandatory
0.1 AInteger32.1.3.6.1.4.1.2254.2.511.1.3.1.5
.1.3.6.1.4.1.2254.2.511.1.4
.1.3.6.1.4.1.2254.2.511.1.4.1
Integer32.1.3.6.1.4.1.2254.2.511.1.4.1.1
Integer32.1.3.6.1.4.1.2254.2.511.1.4.1.2
Integer32.1.3.6.1.4.1.2254.2.511.1.4.1.3
Integer32.1.3.6.1.4.1.2254.2.511.1.4.1.4
dbmsModuleSOHOBS ✓mandatory
0.1 %Integer32.1.3.6.1.4.1.2254.2.511.1.4.1.5
dbmsCellTablemandatory
.1.3.6.1.4.1.2254.2.511.1.5
dbmsCellEntrymandatory
.1.3.6.1.4.1.2254.2.511.1.5.1
Integer32.1.3.6.1.4.1.2254.2.511.1.5.1.1
Integer32.1.3.6.1.4.1.2254.2.511.1.5.1.2
Integer32.1.3.6.1.4.1.2254.2.511.1.5.1.3
Integer32.1.3.6.1.4.1.2254.2.511.1.5.1.4
dbmsCellDCVoltageOBS ✓mandatory
1 mVInteger32.1.3.6.1.4.1.2254.2.511.1.5.1.5
dbmsCellTemperatureOBS ✓mandatory
0.1 degrees CentigradeInteger32.1.3.6.1.4.1.2254.2.511.1.5.1.6
.1.3.6.1.4.1.2254.2.511.2
0.1 VInteger32.1.3.6.1.4.1.2254.2.511.2.1
Integer32.1.3.6.1.4.1.2254.2.511.2.2
0.1 VInteger32.1.3.6.1.4.1.2254.2.511.2.3
0.1 VInteger32.1.3.6.1.4.1.2254.2.511.2.4
dbmsCapacitymandatory
Integer32.1.3.6.1.4.1.2254.2.511.2.5
0.1 VInteger32.1.3.6.1.4.1.2254.2.511.2.6
0.1 VInteger32.1.3.6.1.4.1.2254.2.511.2.7
0.1 AInteger32.1.3.6.1.4.1.2254.2.511.2.8
.1.3.6.1.4.1.2254.2.511.20
.1.3.6.1.4.1.2254.2.511.3
dbmsAlarmDisconnectOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.1
dbmsAlarmOverVoltOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.2
dbmsAlarmUnderVoltOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.3
dbmsAlarmOverTempOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.4
dbmsAlarmUnderTempOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.5
dbmsAlarmOverCurrOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.6
dbmsAlarmBatUnbalanceOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.7
dbmsAlarmHWOBS ✓mandatory
Enumeration.1.3.6.1.4.1.2254.2.511.3.8
.1.3.6.1.4.1.2254.2.511.4
RFC1213-MIBDisplayString.1.3.6.1.4.1.2254.2.511.4.1
dbmsTimeTicksmandatory
RFC1155-SMITimeTicks.1.3.6.1.4.1.2254.2.511.4.2
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. SNMPv2-SMIrfc
  5. SNMPv2-TCrfc
  6. IANAifType-MIBrfc
  7. RFC1213-MIBrfc
  8. DeltaBMS-MIBdeltaselected
Notifications / Traps (16)
NameOIDDescription
.1.3.6.1.4.1.2254.2.511.20.0.1
WARNING: Li-ion Battery Communication Abnormal.
.1.3.6.1.4.1.2254.2.511.20.0.10
INFORMATION: Recover from Li-ion Battery Under Temperature Warning.
.1.3.6.1.4.1.2254.2.511.20.0.11
WARNING: Li-ion Battery Over Current Warning.
.1.3.6.1.4.1.2254.2.511.20.0.12
INFORMATION: Recover from Li-ion Battery Over Current Warning.
.1.3.6.1.4.1.2254.2.511.20.0.13
WARNING: Li-ion Battery Unbalance Warning.
.1.3.6.1.4.1.2254.2.511.20.0.14
INFORMATION: Recover from Li-ion Battery Unbalance Warning.
.1.3.6.1.4.1.2254.2.511.20.0.15
WARNING: Li-ion Battery Hardware Abnormal.
.1.3.6.1.4.1.2254.2.511.20.0.16
INFORMATION: Li-ion Battery Hardware Normal.
.1.3.6.1.4.1.2254.2.511.20.0.2
INFORMATION: Li-ion Battery Communication Normal.
.1.3.6.1.4.1.2254.2.511.20.0.3
WARNING: Li-ion Battery Over Volt Warning
.1.3.6.1.4.1.2254.2.511.20.0.4
INFORMATION: Recover from Li-ion Battery Over Volt Warning.
.1.3.6.1.4.1.2254.2.511.20.0.5
WARNING: Li-ion Battery Under Volt Warning.
.1.3.6.1.4.1.2254.2.511.20.0.6
INFORMATION: Recover from Li-ion Battery Under Volt Warning.
.1.3.6.1.4.1.2254.2.511.20.0.7
WARNING: Li-ion Battery Over Temperature Warning.
.1.3.6.1.4.1.2254.2.511.20.0.8
INFORMATION: Recover from Li-ion Battery Over Temperature Warning.
.1.3.6.1.4.1.2254.2.511.20.0.9
WARNING: Li-ion Battery Under Temperature Warning