DNOS-BOXSERVICES-PRIVATE-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
7
Rows
7
Columns
41
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6 · 1 row entry · 6 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesFansTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFansTable'
Fan Table
boxServicesFansEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1
Box Services Fan Entry
Column Syntax OID
Unique index of fan table entry
Integer32
Constraints:
range: 0-15
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.1
The type of fan
Enumeration
Enumerated Values:
1fixed
2removable
3fixedAC
4removableDC
5fixedDC
6removableAC
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.2
The status of fan. nopower(5) - This state means the fan
is present but no AC is connected.
Enumeration
Enumerated Values:
1notpresent
2operational
3failed
4powering
5nopower
6notpowering
7incompatible
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.3
The speed of fan
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.4
The duty level of fan, in percents
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.5
Unit index for an entry in the Box Services Fan Table
Unsigned32
Constraints:
range: 1-12
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.6
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7 · 1 row entry · 4 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesPowSuppliesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesPowSuppliesTable'
Power Supply
boxServicesPowSuppliesEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1
Box Services Power Supply Entry
Column Syntax OID
Unique index of Power Supply Table entry
Integer32
Constraints:
range: 0-7
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.1
The type of Power Supply
Enumeration
Enumerated Values:
1fixed
2removable
3fixedAC
4removableDC
5fixedDC
6removableAC
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.2
The status of Power Supply.
nopower(5) - This state means the Power Supply is present
but no AC is connected.
incompatible(7) - This state is possible on boards capable
of pluggable Power Sup…
Enumeration
Enumerated Values:
1notpresent
2operational
3failed
4powering
5nopower
6notpowering
7incompatible
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.3
Unit index for an entry in the Box Services Power Supply Table
Unsigned32
Constraints:
range: 1-12
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.4
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8 · 1 row entry · 5 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable'
Temperature sensor
boxServicesTempSensorsEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1
Box Services Temperature Sensor Entry
Column Syntax OID
Unit index for an entry in the Box Services Temperature Sensor Table
Unsigned32
Constraints:
range: 1-12
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.1
Unique index of temperature sensor table entry
Unsigned32
Constraints:
range: 0-15
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.2
The type of temperature sensor
Enumeration
Enumerated Values:
1fixed
2removable
3fixedAC
4removableDC
5fixedDC
6removableAC
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.3
The state of temperature sensor
BoxsTemperatureStatus
Type Values:
0low
1normal
2warning
3critical
4shutdown
5notpresent
6notoperational
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.4
The temperature value reported by sensor
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9 · 1 row entry · 5 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxsUnitPwrUsageHistoryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxsUnitPwrUsageHistoryTable'
A table providing configuration and status of Power Usage History feature
boxsUnitPwrUsageHistoryEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1
Power Usage History Table for a Unit.
Column Syntax OID
This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable.
A non-zero value indicates the unitIndex for the corresponding unit
entry in the Power Usage History Table.
Integer32
Constraints:
range: 1-12
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.1
This is a unique index for an entry in the boxsUnitPwrUsageHistoryTable.
A non-zero value indicates the sampleIndex for the corresponding sample
entry in the Power Usage History Table.
Integer32
Constraints:
range: 1-168
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.2
Time at which the Sample was collected.
OctetString
Constraints:
range: 1-32
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3
Power Consumption (mWatts) at the time of collecting the given sample.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.4
Power Consumption (mWatts) per Stack at the time of collecting the given sample.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.5
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15 · 1 row entry · 3 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesTempUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesTempUnitTable'
Temperature status table
boxServicesTempUnitEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1
Box Services Temperature Unit Entry
Column Syntax OID
Unit index for an entry in the Box Services Temperature Unit Table
Unsigned32
Constraints:
range: 1-12
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.1
The temperature state of the unit
BoxsTemperatureStatus
Type Values:
0low
1normal
2warning
3critical
4shutdown
5notpresent
6notoperational
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.2
The highest temperature currently reported by any sensor on the unit
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.3
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18 · 1 row entry · 9 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesFiberPortsOpticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFiberPortsOpticsTable'
Fiber ports optics data table
boxServicesFiberPortsOpticsEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1
Box Services Fiber ports optics Entry
Column Syntax OID
Port index for an entry in the Box Services Fiber ports optics table
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.1
The temperature measured at this fiber port in degrees Celsius.
DEGREESDNOS-TCDeciInteger32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.2
The voltage measured at this fiber port.
VoltsDNOS-TCMilliInteger32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.3
The current measured at this fiber port.
MilliampsDNOS-TCDeciInteger32 .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.4
The output power measured at this fiber port.
dBmDNOS-TCDBmHundreths .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.5
The input power measured at this fiber port.
dBmDNOS-TCDBmHundreths .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.6
The TX fault status of fiber port.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.7
The LOS status of fiber port.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.8
The fault status of fiber port.
RFC1213-MIBDisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.9
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19 · 1 row entry · 9 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk boxServicesFiberPortsOpticsInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFiberPortsOpticsInfoTable'
Fiber ports optics info data table
boxServicesFiberPortsOpticsInfoEntry row .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1
Box Services Fiber ports optics info Entry
Column Syntax OID
Port index for an entry in the Box Services Fiber ports optics info table
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.1
The Vendor Name of the fiber port.
RFC1213-MIBDisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.2
The Link Length(50um) of the fiber port.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.3
The Link Length(62.5um) of the fiber port.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.4
The Serial Number of the fiber port.
RFC1213-MIBDisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.5
The Part Number of the fiber port.
RFC1213-MIBDisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.6
The Nominal Bit Rate (Mbps) of the fiber port.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.7
The Revision of the fiber port.
RFC1213-MIBDisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.8
The Compliance of the fiber port.
RFC1213-MIBDisplayString .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.9