DNOS-BOXSERVICES-PRIVATE-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
7
Rows
7
Columns
41
boxServicesFansTable
table.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6
·
1 row entry
·
6 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxServicesFansTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFansTable'
Fan Table
Box Services Fan Entry
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesFansIndexUnique index of fan table entry | Integer32 Constraints: range: 0-15 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.1 | ||||||||||||||
| boxServicesFanItemTypeThe type of fan | Enumeration Enumerated Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.2 | ||||||||||||||
| boxServicesFanItemStateThe status of fan. nopower(5) - This state means the fan is present but no AC is connected. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.3 | ||||||||||||||
| boxServicesFanSpeedThe speed of fan | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.4 | ||||||||||||||
| boxServicesFanDutyLevelThe duty level of fan, in percents | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.5 | ||||||||||||||
| boxServicesFanUnitIndexUnit index for an entry in the Box Services Fan Table | Unsigned32 Constraints: range: 1-12 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.6.1.6 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7
·
1 row entry
·
4 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxServicesPowSuppliesTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesPowSuppliesTable'
Power Supply
Box Services Power Supply Entry
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesPowSupplyIndexUnique index of Power Supply Table entry | Integer32 Constraints: range: 0-7 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.1 | ||||||||||||||
| boxServicesPowSupplyItemTypeThe type of Power Supply | Enumeration Enumerated Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.2 | ||||||||||||||
| boxServicesPowSupplyItemStateThe status of Power Supply. nopower(5) - This state means the Power Supply is present but no AC is connected. incompatible(7) - This state is possible on boards capable of pluggable Power Sup… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.3 | ||||||||||||||
| boxServicesPowerSuppUnitIndexUnit index for an entry in the Box Services Power Supply Table | Unsigned32 Constraints: range: 1-12 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.7.1.4 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8
·
1 row entry
·
5 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxServicesTempSensorsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesTempSensorsTable'
Temperature sensor
Box Services Temperature Sensor Entry
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesUnitIndexUnit index for an entry in the Box Services Temperature Sensor Table | Unsigned32 Constraints: range: 1-12 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.1 | ||||||||||||||
| boxServicesTempSensorIndexUnique index of temperature sensor table entry | Unsigned32 Constraints: range: 0-15 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.2 | ||||||||||||||
| boxServicesTempSensorTypeThe type of temperature sensor | Enumeration Enumerated Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.3 | ||||||||||||||
boxServicesTempSensorStateobsolete The state of temperature sensor | BoxsTemperatureStatus Type Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.4 | ||||||||||||||
| boxServicesTempSensorTemperatureThe temperature value reported by sensor | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9
·
1 row entry
·
5 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxsUnitPwrUsageHistoryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxsUnitPwrUsageHistoryTable'
A table providing configuration and status of Power Usage History feature
Power Usage History Table for a Unit.
| Column | Syntax | OID |
|---|---|---|
| boxsPwrUsageHistoryUnitIndexThis is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the unitIndex for the corresponding unit entry in the Power Usage History Table. | Integer32 Constraints: range: 1-12 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.1 |
| boxsPwrUsageHistoryUnitSampleIndexThis is a unique index for an entry in the boxsUnitPwrUsageHistoryTable. A non-zero value indicates the sampleIndex for the corresponding sample entry in the Power Usage History Table. | Integer32 Constraints: range: 1-168 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.2 |
| boxsPwrUsageHistoryUnitSampleTimeTime at which the Sample was collected. | OctetString Constraints: range: 1-32 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.3 |
| boxsPwrUsageHistoryUnitPowerConsumptionPower Consumption (mWatts) at the time of collecting the given sample. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.4 |
| boxsPwrUsageHistoryStackPowerConsumptionPower Consumption (mWatts) per Stack at the time of collecting the given sample. | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.9.1.5 |
boxServicesTempUnitTable
table.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15
·
1 row entry
·
3 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxServicesTempUnitTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesTempUnitTable'
Temperature status table
Box Services Temperature Unit Entry
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| boxServicesTempUnitIndexUnit index for an entry in the Box Services Temperature Unit Table | Unsigned32 Constraints: range: 1-12 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.1 | ||||||||||||||
| boxServicesTempUnitStateThe temperature state of the unit | BoxsTemperatureStatus Type Values:
| .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.2 | ||||||||||||||
| boxServicesTempUnitTemperatureThe highest temperature currently reported by any sensor on the unit | SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.15.1.3 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18
·
1 row entry
·
9 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxServicesFiberPortsOpticsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFiberPortsOpticsTable'
Fiber ports optics data table
Box Services Fiber ports optics Entry
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
| boxServicesFiberPortIndexPort index for an entry in the Box Services Fiber ports optics table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.1 | ||||
| boxServicesFiberPortOpticsTemperatureThe temperature measured at this fiber port in degrees Celsius. | DEGREESDNOS-TCDeciInteger32 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.2 | ||||
| boxServicesFiberPortOpticsVoltageThe voltage measured at this fiber port. | VoltsDNOS-TCMilliInteger32 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.3 | ||||
| boxServicesFiberPortOpticsCurrentThe current measured at this fiber port. | MilliampsDNOS-TCDeciInteger32 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.4 | ||||
| boxServicesFiberPortOpticsPowerOutThe output power measured at this fiber port. | dBmDNOS-TCDBmHundreths | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.5 | ||||
| boxServicesFiberPortOpticsPowerInThe input power measured at this fiber port. | dBmDNOS-TCDBmHundreths | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.6 | ||||
| boxServicesFiberPortOpticsTxFaultThe TX fault status of fiber port. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.7 | ||||
| boxServicesFiberPortOpticsLosThe LOS status of fiber port. | SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.8 | ||||
| boxServicesFiberPortOpticsFaultStatusThe fault status of fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.18.1.9 |
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19
·
1 row entry
·
9 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk boxServicesFiberPortsOpticsInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DNOS-BOXSERVICES-PRIVATE-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DNOS-BOXSERVICES-PRIVATE-MIB::boxServicesFiberPortsOpticsInfoTable'
Fiber ports optics info data table
Box Services Fiber ports optics info Entry
| Column | Syntax | OID |
|---|---|---|
| boxServicesFiberPortsOpticsInfoPortIndexPort index for an entry in the Box Services Fiber ports optics info table | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.1 |
| boxServicesFiberPortsOpticsInfoVendorNameThe Vendor Name of the fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.2 |
| boxServicesFiberPortsOpticsInfoLinkLength50umThe Link Length(50um) of the fiber port. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.3 |
| boxServicesFiberPortsOpticsInfoLinkLength62dot5umThe Link Length(62.5um) of the fiber port. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.4 |
| boxServicesFiberPortsOpticsInfoSerialNumberThe Serial Number of the fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.5 |
| boxServicesFiberPortsOpticsInfoPartNumberThe Part Number of the fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.6 |
| boxServicesFiberPortsOpticsInfoNominalBitRateThe Nominal Bit Rate (Mbps) of the fiber port. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.7 |
| boxServicesFiberPortsOpticsInfoRevisionThe Revision of the fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.8 |
| boxServicesFiberPortsOpticsInfoComplianceThe Compliance of the fiber port. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.19.1.9 |