DELLEMC-OS10-CHASSIS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
46
os10ChassisTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3
·
1 row entry
·
14 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10ChassisTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10ChassisTable'
A list of chassis in a cluster. The chassis table contains the information of each chassis in the cluster.
A list of chassis entries containing information
for the chassis.
for the chassis.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| os10ChassisIndexA unique index for each chassis within the cluster. This value is the chassisId assigned to the chassis. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisTypeThe Dell EMC Networking Model number of the chassis. | DELLEMC-OS10-TC-MIBOs10ChassisDefType Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisMacAddrA 6-octet MAC Address assigned to this chassis. | SNMPv2-TCMacAddress Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisPartNumThe chassis manufacturer's part number. | OctetString Enumerated Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisPPIDThe chassis manufacturer's PPID. | OctetString Constraints: range: 0-24 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisHwRevThe chassis hardware revision number. | OctetString Constraints: range: 0-7 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisServiceTagThe chassis's service tag. | OctetString Constraints: range: 0-14 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisExpServiceCodeThe chassis's express service code. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisNumFanTraysNumber of fan trays in the chassis. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisNumPowerSuppliesNumber of power supplies in the chassis. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisTempTemperature of the chassis. | degrees CentigradeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisProductBaseThe solution id product base | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisProductSNThe solution id product serial number | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10ChassisProductPNThe solution id product part number | OctetString Constraints: range: 0-24 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14 |
os10CardTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4
·
1 row entry
·
10 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10CardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10CardTable'
A list of line cards resident in the chassis. This table contains the information on each RPM and linecards in the chassis.
Entry for each card in the chassis.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| os10CardIndexA unique index for each card in the chassis. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardTypeCard's type. | DELLEMC-OS10-TC-MIBOs10SystemCardType Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardDescriptionA short description of the card. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.3 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardStatusThe current operational state of the card. | DELLEMC-OS10-TC-MIBOs10CardOperStatus Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardTempTemperature of the card. | degrees CentigradeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardPartNumThe card's part number | OctetString Enumerated Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.6 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardPPIDThe card's PPID. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.7 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardHwRevThe card's manufacturer hardware revision number. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.8 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardServiceTagThe card's service tag. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.9 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| os10CardExpServiceCodeThe card's express service code. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.10 |
os10PowerSupplyTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1
·
1 row entry
·
8 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10PowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10PowerSupplyTable'
A list of power supplies resident in the device.
A power supply entry provides all attributes of
that power supply.
that power supply.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| os10PowerSupplyIndexThe unique index of the power supply. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.1 | ||||||||||||||||
| os10PowerSupplyDeviceIdentify the type of device the power supply unit resides (chassis,line card etc..) | DELLEMC-OS10-TC-MIBOs10DeviceType Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.2 | ||||||||||||||||
| os10PowerSupplyDeviceIndexA unique value indentifying a specific os10PowerSupplyDeviceType. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.3 | ||||||||||||||||
| os10PowerSupplyOperStatusThe status of the power supply. | DELLEMC-OS10-TC-MIBOs10CmnOperStatus Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4 | ||||||||||||||||
| os10PowerSupplyTypeThe type of the power supply. | Enumeration | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.5 | ||||||||||||||||
| os10PowerSupplyPPIDThe power supply's PPID. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.6 | ||||||||||||||||
| os10PowerSupplyServiceTagThe power supply's service tag. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.7 | ||||||||||||||||
| os10PowerSupplyExpServiceCodeThe power supply's express service code. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.8 |
os10FanTrayTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2
·
1 row entry
·
7 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10FanTrayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10FanTrayTable'
A list of fan trays resident in the device.
A fan entry containing objects for a
particular fan tray.
particular fan tray.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| os10FanTrayIndexThe unique index of the fan tray. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.1 | ||||||||||||||||
| os10FanTrayDeviceIdentify the type of device this fan tray unit resides (chassis,line card etc..) | DELLEMC-OS10-TC-MIBOs10DeviceType Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.2 | ||||||||||||||||
| os10FanTrayDeviceIndexA unique value indentifying a specific os10FanTrayDevice. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.3 | ||||||||||||||||
| os10FanTrayOperStatusThe status of the fan tray. | DELLEMC-OS10-TC-MIBOs10CmnOperStatus Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4 | ||||||||||||||||
| os10FanTrayPPIDThe fan tray's PPID. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.5 | ||||||||||||||||
| os10FanTrayServiceTagThe fan tray's service tag. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.6 | ||||||||||||||||
| os10FanTrayExpServiceCodeThe fan tray's express service code. | OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.7 |
os10FanTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3
·
1 row entry
·
7 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10FanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10FanTable'
A list of fans installed in the chassis.
A fan entry containing objects for a
particular fan in the chassis.
particular fan in the chassis.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| os10FanIndexThe unique value for each fan in the device. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.1 | ||||||||||||||||
| os10FanDeviceIdentify the type of device this fan resides. (chassis,line card etc..) | DELLEMC-OS10-TC-MIBOs10DeviceType Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.2 | ||||||||||||||||
| os10FanDeviceIndexA unique value indentifying a specific os10FanDevice. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.3 | ||||||||||||||||
| os10FanEntityIdentify the type of system componet where the fan is installed. | Enumeration | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.4 | ||||||||||||||||
| os10FanEntitySlotA unique value indentifying a specific os10FanEntity. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.5 | ||||||||||||||||
| os10FanIdA unique value indentifying a specific fan in a specific os10FanEntity. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.6 | ||||||||||||||||
| os10FanOperStatusThe status of the fan. | DELLEMC-OS10-TC-MIBOs10CmnOperStatus Type Values:
| .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7 |