DELLEMC-OS10-CHASSIS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
46
os10ChassisTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3
·
1 row entry
·
14 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10ChassisTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10ChassisTable'
A list of chassis in a cluster. The chassis table contains the information of each chassis in the cluster.
A list of chassis entries containing information
for the chassis.
for the chassis.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique index for each chassis within
the cluster. This value is the chassisId assigned to the chassis. |
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The Dell EMC Networking Model number of the chassis.
|
DELLEMC-OS10-TC-MIBOs10ChassisDefType Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
A 6-octet MAC Address assigned to this chassis.
|
SNMPv2-TCMacAddress Type Constraints: range: 6Description: Represents an 802 MAC address represented in the `canonical' order defined by IEEE 802.1a, i.e., as if it were transmitted least significant bit first, even though 802.5 (in contrast to other 802.x protocols) requires M… |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The chassis manufacturer's part number.
|
OctetString Enumerated Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The chassis manufacturer's PPID.
|
OctetString Constraints: range: 0-24 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The chassis hardware revision number.
|
OctetString Constraints: range: 0-7 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The chassis's service tag.
|
OctetString Constraints: range: 0-14 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The chassis's express service code.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Number of fan trays in the chassis.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Number of power supplies in the chassis.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Temperature of the chassis.
|
degrees CentigradeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The solution id product base
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The solution id product serial number
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The solution id product part number
|
OctetString Constraints: range: 0-24 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14 |
os10CardTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4
·
1 row entry
·
10 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10CardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10CardTable'
A list of line cards resident in the chassis. This table contains the information on each RPM and linecards in the chassis.
Entry for each card in the chassis.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A unique index for each card in the chassis.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Card's type.
|
DELLEMC-OS10-TC-MIBOs10SystemCardType Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
A short description of the card.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The current operational state of the card.
|
DELLEMC-OS10-TC-MIBOs10CardOperStatus Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Temperature of the card.
|
degrees CentigradeSNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The card's part number
|
OctetString Enumerated Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The card's PPID.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The card's manufacturer hardware revision number.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The card's service tag.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The card's express service code.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.10 |
os10PowerSupplyTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1
·
1 row entry
·
8 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10PowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10PowerSupplyTable'
A list of power supplies resident in the device.
A power supply entry provides all attributes of
that power supply.
that power supply.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The unique index of the power supply.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.1 |
||||||||||||||||
|
Identify the type of device the power supply unit resides
(chassis,line card etc..) |
DELLEMC-OS10-TC-MIBOs10DeviceType Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.2 |
||||||||||||||||
|
A unique value indentifying a specific os10PowerSupplyDeviceType.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.3 |
||||||||||||||||
|
The status of the power supply.
|
DELLEMC-OS10-TC-MIBOs10CmnOperStatus Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4 |
||||||||||||||||
|
The type of the power supply.
|
Enumeration | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.5 |
||||||||||||||||
|
The power supply's PPID.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.6 |
||||||||||||||||
|
The power supply's service tag.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.7 |
||||||||||||||||
|
The power supply's express service code.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.8 |
os10FanTrayTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2
·
1 row entry
·
7 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10FanTrayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10FanTrayTable'
A list of fan trays resident in the device.
A fan entry containing objects for a
particular fan tray.
particular fan tray.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The unique index of the fan tray.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.1 |
||||||||||||||||
|
Identify the type of device this fan tray unit resides
(chassis,line card etc..) |
DELLEMC-OS10-TC-MIBOs10DeviceType Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.2 |
||||||||||||||||
|
A unique value indentifying a specific os10FanTrayDevice.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.3 |
||||||||||||||||
|
The status of the fan tray.
|
DELLEMC-OS10-TC-MIBOs10CmnOperStatus Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4 |
||||||||||||||||
|
The fan tray's PPID.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.5 |
||||||||||||||||
|
The fan tray's service tag.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.6 |
||||||||||||||||
|
The fan tray's express service code.
|
OctetString | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.7 |
os10FanTable
table.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3
·
1 row entry
·
7 columns
Uses the dell variant from
Command help
/opt/observium/mibs/dell.
Walk os10FanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10FanTable'
A list of fans installed in the chassis.
A fan entry containing objects for a
particular fan in the chassis.
particular fan in the chassis.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The unique value for each fan in the device.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.1 |
||||||||||||||||
|
Identify the type of device this fan resides.
(chassis,line card etc..) |
DELLEMC-OS10-TC-MIBOs10DeviceType Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.2 |
||||||||||||||||
|
A unique value indentifying a specific os10FanDevice.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.3 |
||||||||||||||||
|
Identify the type of system componet where the fan is installed.
|
Enumeration | .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.4 |
||||||||||||||||
|
A unique value indentifying a specific os10FanEntity.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.5 |
||||||||||||||||
|
A unique value indentifying a specific fan in a specific os10FanEntity.
|
SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.6 |
||||||||||||||||
|
The status of the fan.
|
DELLEMC-OS10-TC-MIBOs10CmnOperStatus Type Values:
|
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.7 |