.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3 · 1 row entry · 14 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk os10ChassisTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10ChassisTable'
A list of chassis in a cluster.
The chassis table contains the information of  
 each chassis in the cluster.
os10ChassisEntry row .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1
A list of chassis entries containing information
for the chassis.
Indexes
No indexes recorded
Column Syntax OID
A unique index for each chassis within
the cluster.
This value is the chassisId assigned to the chassis.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.1
The Dell EMC Networking Model number of the chassis.
DELLEMC-OS10-TC-MIBOs10ChassisDefType
Type Values:
1s6000on
2s4048on
3s4048Ton
4s3048on
5s6010on
6s4148Fon
7s4128Fon
8s4148Ton
9s4128Ton
10s4148FEon
11s4148Uon
12s4200on
13mx5108Non
14mx9116Non
15s5148Fon
16z9100on
17s4248FBon
18s4248FBLon
19s4112Fon
20s4112Ton
21z9264Fon
22z9224Fon
23s5212Fon
24s5224Fon
25s5232Fon
26s5248Fon
27s5296Fon
28z9332Fon
29n3248TEon
9999unknown
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.2
A 6-octet MAC Address assigned to this chassis.
SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.3
The chassis manufacturer's part number.
OctetString
Enumerated Values:
1unknown
2ac
3dc
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.4
The chassis manufacturer's PPID.
OctetString
Constraints:
range: 0-24
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.5
The chassis hardware revision number.
OctetString
Constraints:
range: 0-7
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.6
The chassis's service tag.
OctetString
Constraints:
range: 0-14
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.7
The chassis's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.8
Number of fan trays in the chassis.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.9
Number of power supplies in the chassis.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.10
Temperature of the chassis.
degrees CentigradeSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.11
The solution id product base
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.12
The solution id product serial number
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.13
The solution id product part number
OctetString
Constraints:
range: 0-24
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.3.1.14
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4 · 1 row entry · 10 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk os10CardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10CardTable'
A list of line cards resident in the chassis.
This table contains the information on each RPM and linecards
in the chassis.
os10CardEntry row .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1
Entry for each card in the chassis.
Indexes
No indexes recorded
Column Syntax OID
A unique index for each card in the chassis.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.1
Card's type.
DELLEMC-OS10-TC-MIBOs10SystemCardType
Type Values:
0notPresent
1s6000on
2s4048on
3s4048Ton
4s3048on
5s6010on
6s4148Fon
7s4128Fon
8s4148Ton
9s4128Ton
10s4148FEon
11s4148Uon
12s4200on
13mx5108Non
14mx9116Non
15s5148Fon
16z9100on
17s4248FBon
18s4248FBLon
19s4112Fon
20s4112Ton
21z9264Fon
22z9232Fon
23s5212Fon
24s5224Fon
25s5232Fon
26s5248Fon
27s5296Fon
28z9332Fon
29n3248TEon
9999unknown
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.2
A short description of the card.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.3
The current operational state of the card.
DELLEMC-OS10-TC-MIBOs10CardOperStatus
Type Values:
1ready
2cardMisMatch
3cardProblem
4diagMode
5cardAbsent
6offline
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.4
Temperature of the card.
degrees CentigradeSNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.5
The card's part number
OctetString
Enumerated Values:
1psu
2fanTray
.1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.6
The card's PPID.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.7
The card's manufacturer hardware revision number.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.8
The card's service tag.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.9
The card's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.1.4.1.10
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1 · 1 row entry · 8 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk os10PowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10PowerSupplyTable'
A list of power supplies resident 
in the device.
os10PowerSupplyEntry row .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1
A power supply entry provides all attributes of
that power supply.
Indexes
No indexes recorded
Column Syntax OID
The unique index of the power supply.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.1
Identify the type of device the power supply unit resides
(chassis,line card etc..)
DELLEMC-OS10-TC-MIBOs10DeviceType
Type Values:
1chassis
2stack
3rpm
4supervisor
5linecard
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.2
A unique value indentifying a specific os10PowerSupplyDeviceType.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.3
The status of the power supply.
DELLEMC-OS10-TC-MIBOs10CmnOperStatus
Type Values:
1up
2down
3testing
4unknown
5dormant
6notPresent
7lowerLayerDown
8failed
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.4
The type of the power supply.
Enumeration .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.5
The power supply's PPID.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.6
The power supply's service tag.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.7
The power supply's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.1.1.8
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2 · 1 row entry · 7 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk os10FanTrayTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10FanTrayTable'
A list of fan trays resident in the device.
os10FanTrayEntry row .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1
A fan entry containing objects for a
particular fan tray.
Indexes
No indexes recorded
Column Syntax OID
The unique index of the fan tray.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.1
Identify the type of device this fan tray unit resides
(chassis,line card etc..)
DELLEMC-OS10-TC-MIBOs10DeviceType
Type Values:
1chassis
2stack
3rpm
4supervisor
5linecard
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.2
A unique value indentifying a specific os10FanTrayDevice.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.3
The status of the fan tray.
DELLEMC-OS10-TC-MIBOs10CmnOperStatus
Type Values:
1up
2down
3testing
4unknown
5dormant
6notPresent
7lowerLayerDown
8failed
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.4
The fan tray's PPID.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.5
The fan tray's service tag.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.6
The fan tray's express service code.
OctetString .1.3.6.1.4.1.674.11000.5000.100.4.1.2.2.1.7

os10FanTable

table
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3 · 1 row entry · 7 columns
Uses the dell variant from /opt/observium/mibs/dell.
Command help
Walk os10FanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DELLEMC-OS10-CHASSIS-MIB' -M '/opt/observium/mibs/dell:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DELLEMC-OS10-CHASSIS-MIB::os10FanTable'
A list of fans installed in the chassis.
os10FanEntry row .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1
A fan entry containing objects for a
particular fan in the chassis.
Indexes
No indexes recorded
Column Syntax OID
The unique value for each fan in the device.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.1
Identify the type of device this fan resides.
(chassis,line card etc..)
DELLEMC-OS10-TC-MIBOs10DeviceType
Type Values:
1chassis
2stack
3rpm
4supervisor
5linecard
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.2
A unique value indentifying a specific os10FanDevice.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.3
Identify the type of system componet where the fan is installed.
Enumeration .1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.4
A unique value indentifying a specific os10FanEntity.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.5
A unique value indentifying a specific fan in a specific os10FanEntity.
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.674.11000.5000.100.4.1.2.3.1.6
The status of the fan.
DELLEMC-OS10-TC-MIBOs10CmnOperStatus
Type Values:
1up
2down
3testing
4unknown
5dormant
6notPresent
7lowerLayerDown
8failed