DELL-MM-MIB-SMIv2

Imported Objects

OBJECT-GROUP, NOTIFICATION-GROUPSNMPv2-CONF
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, enterprisesSNMPv2-SMI
TEXTUAL-CONVENTION, DisplayStringSNMPv2-TC

Type Definitions (9)

Name Base Type Values/Constraints
DellMmTypeEnumerationother(1), unknown(2), mxMM(3)
DellPowerIndexRangeInteger32range: 1
DellPowerReadingOctetStringrange: 0..32
DellPSUCapableEnumerationabsent(1), none(2), basic(3)
DellPSUIndexRangeInteger32range: 1..6
DellStatusEnumerationother(1), unknown(2), ok(3), nonCritical(4), critical(5), nonRecoverable(6)
DellStringOctetStringrange: 0..1023
DellTemperatureReadingInteger32
DellTimestampOctetStringrange: 26

Objects

dell .1.3.6.1.4.1.674
server3 .1.3.6.1.4.1.674.10892
dmmOutOfBandGroup .1.3.6.1.4.1.674.10892.6
dmmInformationGroup .1.3.6.1.4.1.674.10892.6.1
dmmProductInfoGroup .1.3.6.1.4.1.674.10892.6.1.1
dmmProductName .1.3.6.1.4.1.674.10892.6.1.1.1
dmmProductType .1.3.6.1.4.1.674.10892.6.1.1.10
dmmProductChassisDataCenter .1.3.6.1.4.1.674.10892.6.1.1.11
dmmProductChassisAisle .1.3.6.1.4.1.674.10892.6.1.1.12
dmmProductChassisRack .1.3.6.1.4.1.674.10892.6.1.1.13
dmmProductChassisRackSlot .1.3.6.1.4.1.674.10892.6.1.1.14
dmmProductChassisModel .1.3.6.1.4.1.674.10892.6.1.1.15
dmmProductChassisExpressServiceCode .1.3.6.1.4.1.674.10892.6.1.1.16
dmmProductChassisSystemID .1.3.6.1.4.1.674.10892.6.1.1.17
dmmProductShortName .1.3.6.1.4.1.674.10892.6.1.1.2
dmmProductDescription .1.3.6.1.4.1.674.10892.6.1.1.3
dmmProductManufacturer .1.3.6.1.4.1.674.10892.6.1.1.4
dmmProductVersion .1.3.6.1.4.1.674.10892.6.1.1.5
dmmChassisServiceTag .1.3.6.1.4.1.674.10892.6.1.1.6
dmmProductURL .1.3.6.1.4.1.674.10892.6.1.1.7
dmmProductChassisAssetTag .1.3.6.1.4.1.674.10892.6.1.1.8
dmmProductChassisName .1.3.6.1.4.1.674.10892.6.1.1.9
dmmFirmwareGroup .1.3.6.1.4.1.674.10892.6.1.2
dmmFirmwareVersion .1.3.6.1.4.1.674.10892.6.1.2.1
dmmFirmwareVersion2 .1.3.6.1.4.1.674.10892.6.1.2.2
dmmStatusGroup .1.3.6.1.4.1.674.10892.6.2
dmmGlobalSystemStatus .1.3.6.1.4.1.674.10892.6.2.1
dmmChassisStatusGroup .1.3.6.1.4.1.674.10892.6.3
dmmStatusNowGroup .1.3.6.1.4.1.674.10892.6.3.1
dmmIOMCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.1
dmmRedCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.2
dmmPowerCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.3
dmmFanCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.4
dmmBladeCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.5
dmmTempCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.6
dmmMMCurrStatus .1.3.6.1.4.1.674.10892.6.3.1.7
dmmChassisFrontPanelAmbientTemperature .1.3.6.1.4.1.674.10892.6.3.1.8
dmmChassisPowerGroup .1.3.6.1.4.1.674.10892.6.4
dmmPowerTable .1.3.6.1.4.1.674.10892.6.4.1
dmmPowerTableEntry .1.3.6.1.4.1.674.10892.6.4.1.1
dmmPowerChassisIndex .1.3.6.1.4.1.674.10892.6.4.1.1.1
dmmPowerIdlePower .1.3.6.1.4.1.674.10892.6.4.1.1.2
dmmPowerKWhCumulative .1.3.6.1.4.1.674.10892.6.4.1.1.3
dmmPowerKWhCumulativeTime .1.3.6.1.4.1.674.10892.6.4.1.1.4
dmmPowerWattsPeakUsage .1.3.6.1.4.1.674.10892.6.4.1.1.5
dmmPowerWattsPeakTime .1.3.6.1.4.1.674.10892.6.4.1.1.6
dmmPowerWattsMinUsage .1.3.6.1.4.1.674.10892.6.4.1.1.7
dmmPowerWattsMinTime .1.3.6.1.4.1.674.10892.6.4.1.1.8
dmmPowerWattsReading .1.3.6.1.4.1.674.10892.6.4.1.1.9
dmmPSUTable .1.3.6.1.4.1.674.10892.6.4.2
dmmPSUTableEntry .1.3.6.1.4.1.674.10892.6.4.2.1
dmmPSUChassisIndex .1.3.6.1.4.1.674.10892.6.4.2.1.1
dmmPSUIndex .1.3.6.1.4.1.674.10892.6.4.2.1.2
dmmPSULocation .1.3.6.1.4.1.674.10892.6.4.2.1.3
dmmPSUState .1.3.6.1.4.1.674.10892.6.4.2.1.4
dmmPSUType .1.3.6.1.4.1.674.10892.6.4.2.1.5
dmmPSUCapacity .1.3.6.1.4.1.674.10892.6.4.2.1.6
dmmPSUVoltage .1.3.6.1.4.1.674.10892.6.4.2.1.7
dmmPSUCurrStatus .1.3.6.1.4.1.674.10892.6.4.2.1.8
dmmChassisAlert2Group .1.3.6.1.4.1.674.10892.6.5
dmmChassisAlert2Variables .1.3.6.1.4.1.674.10892.6.5.1
dmmCA2MessageID .1.3.6.1.4.1.674.10892.6.5.1.1
dmmCA2Message .1.3.6.1.4.1.674.10892.6.5.1.2
dmmCA2MessageArgs .1.3.6.1.4.1.674.10892.6.5.1.3
dmmCA2AlertStatus .1.3.6.1.4.1.674.10892.6.5.1.4
dmmCA2FQDD .1.3.6.1.4.1.674.10892.6.5.1.5
dmmGenericAlertGroup .1.3.6.1.4.1.674.10892.6.6
dmmGenericAlertVariables .1.3.6.1.4.1.674.10892.6.6.1
dmmDeviceServiceTag .1.3.6.1.4.1.674.10892.6.6.1.1
conformanceGroup .1.3.6.1.4.1.674.10892.6.7
conformanceMIBGroups .1.3.6.1.4.1.674.10892.6.7.1
conformanceMIBnotificationGroup .1.3.6.1.4.1.674.10892.6.7.2

Notifications/Traps

NameOIDDescription
alert2CMCTestTrap.1.3.6.1.4.1.674.10892.6.5.0.10395
Test trap generated in response to a user request.
alert2SWCConfigurationFailure.1.3.6.1.4.1.674.10892.6.5.0.10529
Software configuration failure.
alert2SWCConfigurationWarning.1.3.6.1.4.1.674.10892.6.5.0.10530
Software configuration warning.
alert2PCIDeviceConfigurationInformation.1.3.6.1.4.1.674.10892.6.5.0.10611
PCI device configuration information.
alert2IOVConfigurationWarning.1.3.6.1.4.1.674.10892.6.5.0.10746
IO Virtualization configuration warning.
alert2IOVConfigurationInformation.1.3.6.1.4.1.674.10892.6.5.0.10747
IO Virtualization configuration information.
alert2FanFailure







.1.3.6.1.4.1.674.10892.6.5.0.2153
Fan failure.
alert2FanWarning







.1.3.6.1.4.1.674.10892.6.5.0.2154
Fan warning.
alert2FanInformation







.1.3.6.1.4.1.674.10892.6.5.0.2155
Fan information.
alert2TemperatureProbeFailure







.1.3.6.1.4.1.674.10892.6.5.0.2161
Temperature sensor has detected a failure value.
alert2TemperatureProbeWarning







.1.3.6.1.4.1.674.10892.6.5.0.2162
Temperature sensor has detected a warning value.
alert2TemperatureProbeNormal







.1.3.6.1.4.1.674.10892.6.5.0.2163
Temperature sensor value is within range.
alert2VoltageProbeFailure







.1.3.6.1.4.1.674.10892.6.5.0.2169
Voltage sensor has detected a failure value.
alert2VoltageProbeWarning







.1.3.6.1.4.1.674.10892.6.5.0.2170
Voltage sensor has detected a warning value.
alert2VoltageProbeNormal







.1.3.6.1.4.1.674.10892.6.5.0.2171
Voltage sensor reading is within range.
alert2AmperageProbeFailure







.1.3.6.1.4.1.674.10892.6.5.0.2177
Current sensor has detected a failure value.
alert2AmperageProbeWarning







.1.3.6.1.4.1.674.10892.6.5.0.2178
Current sensor has detected a warning value.
alert2AmperageProbeNormal







.1.3.6.1.4.1.674.10892.6.5.0.2179
Current sensor reading is within range.
alert2PowerSupplyFailure







.1.3.6.1.4.1.674.10892.6.5.0.2185
Power supply has detected a failure.
alert2PowerSupplyWarning







.1.3.6.1.4.1.674.10892.6.5.0.2186
Power supply has detected a warning.
alert2PowerSupplyNormal







.1.3.6.1.4.1.674.10892.6.5.0.2187
Power supply has returned to normal.
alert2BatteryFailure







.1.3.6.1.4.1.674.10892.6.5.0.2225
Battery has failed or battery is absent.
alert2BatteryWarning







.1.3.6.1.4.1.674.10892.6.5.0.2226
Battery is low.
alert2BatteryNormal







.1.3.6.1.4.1.674.10892.6.5.0.2227
ate has returned to normal;
or battery presence had been detected.
alert2LinkStatusFailure







.1.3.6.1.4.1.674.10892.6.5.0.2249
Link status failure or critical event.
alert2LinkStatusWarning







.1.3.6.1.4.1.674.10892.6.5.0.2250
Link status warning.
alert2LinkStatusInformation







.1.3.6.1.4.1.674.10892.6.5.0.2251
Link status information.
alert2PowerUsageFailure







.1.3.6.1.4.1.674.10892.6.5.0.2273
Power usage failure.
alert2PowerUsageWarning







.1.3.6.1.4.1.674.10892.6.5.0.2274
Power usage warning.
alert2PowerUsageInformation







.1.3.6.1.4.1.674.10892.6.5.0.2275
Power usage information.
alert2HardwareConfigurationFailure







.1.3.6.1.4.1.674.10892.6.5.0.2329
Hardware configuration failure or critical event.
alert2HardwareConfigurationWarning







.1.3.6.1.4.1.674.10892.6.5.0.2330
Hardware configuration warning.
alert2HardwareConfigurationInformation







.1.3.6.1.4.1.674.10892.6.5.0.2331
Hardware configuration information.
alert2SoftwareConfigurationFailure







.1.3.6.1.4.1.674.10892.6.5.0.2337
Software configuration failure.
alert2SoftwareConfigurationWarning







.1.3.6.1.4.1.674.10892.6.5.0.2338
Software configuration warning.
alert2SoftwareConfigurationInformation







.1.3.6.1.4.1.674.10892.6.5.0.2339
Software configuration information.
alert2SystemEventLogFailure







.1.3.6.1.4.1.674.10892.6.5.0.2377
System Event Log failure or critical event.
alert2SystemEventLogWarning







.1.3.6.1.4.1.674.10892.6.5.0.2378
System Event Log warning.
alert2SystemEventLogInformation







.1.3.6.1.4.1.674.10892.6.5.0.2379
System Event Log information.
alert2SecurityFailure







.1.3.6.1.4.1.674.10892.6.5.0.2385
Security failure or critical event.
alert2SecurityWarning







.1.3.6.1.4.1.674.10892.6.5.0.2386
Security warning.
alert2SecurityInformation







.1.3.6.1.4.1.674.10892.6.5.0.2387
Security information.
alert2CableFailure







.1.3.6.1.4.1.674.10892.6.5.0.2393
Cable failure.
alert2PowerSupplyAbsent







.1.3.6.1.4.1.674.10892.6.5.0.2465
Power supply is absent.
alert2RedundancyLost







.1.3.6.1.4.1.674.10892.6.5.0.2473
Redundancy is lost.
alert2RedundancyDegraded







.1.3.6.1.4.1.674.10892.6.5.0.2474
Redundancy is degraded.
alert2RedundancyInformation







.1.3.6.1.4.1.674.10892.6.5.0.2475
Redundancy information.
alert2CMCFailure







.1.3.6.1.4.1.674.10892.6.5.0.2545
Chassis Management Module detected an error.
alert2CMCWarning







.1.3.6.1.4.1.674.10892.6.5.0.2546
Chassis Management Module detected a warning.
alert2IOVirtualizationFailure







.1.3.6.1.4.1.674.10892.6.5.0.2553
IO Virtualization failure or critical event.
alert2IOVirtualizationWarning







.1.3.6.1.4.1.674.10892.6.5.0.2554
IO Virtualization warning.
alert2IOVirtualizationInformation







.1.3.6.1.4.1.674.10892.6.5.0.2555
IO Virtualization information.
alert2StorageManagementFailure







.1.3.6.1.4.1.674.10892.6.5.0.4177
nagement has detected a device independent error condition.
There is no global status change associated with this trap.
alert2StorageManagementWarning







.1.3.6.1.4.1.674.10892.6.5.0.4178
nagement has detected a device independent warning
condition. There is no global status change associated with this
trap.
alert2StorageManagementInformation







.1.3.6.1.4.1.674.10892.6.5.0.4179
nagement information.
There is no global status change associated with this trap.
alert2StorageFanFailure







.1.3.6.1.4.1.674.10892.6.5.0.4201
Storage Fan failure.
alert2StorageFanWarning







.1.3.6.1.4.1.674.10892.6.5.0.4202
Storage Fan warning.
alert2StorageFanInformation







.1.3.6.1.4.1.674.10892.6.5.0.4203
Storage Fan information.
alert2StorageTemperatureProbeFailure







.1.3.6.1.4.1.674.10892.6.5.0.4209
Storage Temperature probe failure.
alert2StorageTemperatureProbeWarning







.1.3.6.1.4.1.674.10892.6.5.0.4210
Storage Temperature probe warning.
alert2StorageTemperatureProbeInformation







.1.3.6.1.4.1.674.10892.6.5.0.4211
Storage Temperature probe information.
alert2StoragePowerSupplyFailure







.1.3.6.1.4.1.674.10892.6.5.0.4233
Storage Power supply failure.
alert2StoragePowerSupplyWarning







.1.3.6.1.4.1.674.10892.6.5.0.4234
Storage Power supply warning.
alert2StoragePowerSupplyInformation







.1.3.6.1.4.1.674.10892.6.5.0.4235
Storage Power supply information.
alert2StorageBatteryFailure







.1.3.6.1.4.1.674.10892.6.5.0.4273
Storage Battery failure.
alert2StorageBatteryWarning







.1.3.6.1.4.1.674.10892.6.5.0.4274
Storage Battery warning.
alert2StorageBatteryInformation







.1.3.6.1.4.1.674.10892.6.5.0.4275
Storage Battery information.
alert2StorageControllerFailure







.1.3.6.1.4.1.674.10892.6.5.0.4329
Storage Controller failure.
alert2StorageControllerWarning







.1.3.6.1.4.1.674.10892.6.5.0.4330
Storage Controller warning.
alert2StorageControllerInformation







.1.3.6.1.4.1.674.10892.6.5.0.4331
Storage Controller information.
alert2StorageEnclosureFailure







.1.3.6.1.4.1.674.10892.6.5.0.4337
Storage Enclosure failure.
alert2StorageEnclosureWarning







.1.3.6.1.4.1.674.10892.6.5.0.4338
Storage Enclosure warning.
alert2StorageEnclosureInformation







.1.3.6.1.4.1.674.10892.6.5.0.4339
Storage Enclosure information.
alert2StoragePhysicalDiskFailure







.1.3.6.1.4.1.674.10892.6.5.0.4345
Storage Physical disk failure.
alert2StoragePhysicalDiskWarning







.1.3.6.1.4.1.674.10892.6.5.0.4346
Storage Physical disk warning.
alert2StoragePhysicalDiskInformation







.1.3.6.1.4.1.674.10892.6.5.0.4347
Storage Physical disk information.
alert2StorageVirtualDiskFailure







.1.3.6.1.4.1.674.10892.6.5.0.4353
Storage Virtual disk failure.
alert2StorageVirtualDiskWarning







.1.3.6.1.4.1.674.10892.6.5.0.4354
Storage Virtual disk warning.
alert2StorageVirtualDiskInformation





.1.3.6.1.4.1.674.10892.6.5.0.4355
Storage Virtual disk information.
alert2StorageSecurityFailure





.1.3.6.1.4.1.674.10892.6.5.0.4433
Storage Security failure or critical event.
alert2StorageSecurityWarning





.1.3.6.1.4.1.674.10892.6.5.0.4434
Storage Security warning.
alert2StorageSecurityInformation





.1.3.6.1.4.1.674.10892.6.5.0.4435
Storage Security information.
alert2SoftwareChangeUpdateWarning

.1.3.6.1.4.1.674.10892.6.5.0.6314
Software change update warning.
alert2PowerSupplyAuditFailure.1.3.6.1.4.1.674.10892.6.5.0.8329
Power Supply audit failure or critical event.
alert2PowerSupplyAuditWarning.1.3.6.1.4.1.674.10892.6.5.0.8330
Power Supply audit warning.
alert2SoftwareChangeAuditFailure.1.3.6.1.4.1.674.10892.6.5.0.8361
Software change audit failure or critical event.
alert2PowerUsageAuditFailure.1.3.6.1.4.1.674.10892.6.5.0.8417
Power usage audit failure or critical event.
alert2PowerUsageAuditWarning.1.3.6.1.4.1.674.10892.6.5.0.8418
Power usage audit warning.
alert2PowerUsageAuditInformation.1.3.6.1.4.1.674.10892.6.5.0.8419
Power usage audit information.
alert2LicenseFailure.1.3.6.1.4.1.674.10892.6.5.0.8513
License failure.
alert2LicenseWarning.1.3.6.1.4.1.674.10892.6.5.0.8514
License warning.
alert2LicenseInformation.1.3.6.1.4.1.674.10892.6.5.0.8515
License information.
alert2PCIDeviceAuditWarning.1.3.6.1.4.1.674.10892.6.5.0.8562
PCI device audit warning.
alert2CMCAuditFailure.1.3.6.1.4.1.674.10892.6.5.0.8689
Chassis Management Module audit failure or critical event.
alert2CMCAuditWarning.1.3.6.1.4.1.674.10892.6.5.0.8690
Chassis Management Module audit warning.
alert2CMCAuditInformation.1.3.6.1.4.1.674.10892.6.5.0.8691
Chassis Management Module audit information.
alert2IOVirtualizationAuditWarning.1.3.6.1.4.1.674.10892.6.5.0.8698
IO Virtualization audit warning.
alertGenericCritical.1.3.6.1.4.1.674.10892.6.6.0.100
MM generic critical system alert.
alertGenericWarning.1.3.6.1.4.1.674.10892.6.6.0.200
MM generic warning system alert.
alertGenericNormal.1.3.6.1.4.1.674.10892.6.6.0.300
MM generic normal system alert.
alertGenericInformational.1.3.6.1.4.1.674.10892.6.6.0.400
MM generic information system alert.
alertGenericTestTrapEvent.1.3.6.1.4.1.674.10892.6.6.0.500
MM Generated a test trap event in response to a user request.