CTRON-FDDI-FNB-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
11
Rows
11
Columns
42

ctFDDIResourceTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.1.1 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDIResourceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDIResourceTable'
This table specifies the physical resources
associated with the FNB and general FNB operation for a 
particular module in a particular slot.
ctFDDIResourceEntry row .1.3.6.1.4.1.52.4.1.2.5.1.1.1.1
Defines a specific physical resource entry
Column Syntax OID
A specific instance of a slot as defined by chSlotID
as defined in the chassis MIB.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.1
A unique index that defines a specific physcial resource for
which this relationship exists. The value of this is as
defined by chResourceID in the chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.2
Defines the type of resource. This is the same value as
chResourceType in the chassis MIB.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.3
This object defines the number of instances of a physical
resource.

Specific resource instances are physically located from
top-to-bottom on a particular module. If there are multiple
'columns' of a res…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.1.1.1.4

ctFDDINonMuxCapTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.2.1 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDINonMuxCapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDINonMuxCapTable'
This table describes all possible capabilities/configurations
for all non-muxed FDDI configurations within the chassis.
ctFDDINonMuxCapEntry row .1.3.6.1.4.1.52.4.1.2.5.1.2.1.1
Describes a particular capability/configuration entry.
Column Syntax OID
ctFDDINMSlotmandatory
The slot within the chassis for which this
configuration information is defined.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.1
The instance of a particular configuration.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.2
This object defines a specific valid connection
configuration. It will specify the connection state of all
resource instances. If an instance of a resource is
not specified, then it is disconnected.

Ea…
RFC1213-MIBDisplayString .1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.3
This object contains a textual description of a valid
connection configuration. This is a more user-friendly
representation of the configuration than the ctFDDINMConfig
object.
RFC1213-MIBDisplayString .1.3.6.1.4.1.52.4.1.2.5.1.2.1.1.4

ctFDDINonMuxCapEnableTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.2.2 · 1 row entry · 2 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDINonMuxCapEnableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDINonMuxCapEnableTable'
This table describes the currently enabled configuration
for each module.
ctFDDINonMuxCapEnableEntry row .1.3.6.1.4.1.52.4.1.2.5.1.2.2.1
Describes a specific configuration enable entry.
Column Syntax OID
A specific slot for which this configuration enable
pertains.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.1
A specific configuration that is enabled.

Enabling a configuration is done by writing the value of
ctFDDINMConfigID for a specific configuration to this object.

This object, when read, w…
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.2.1.2

ctFDDINonMuxConnectionTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.2.3 · 1 row entry · 6 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDINonMuxConnectionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDINonMuxConnectionTable'
This table defines specific information for each defined
FDDI/FNB connection.  This maps the third sub identifier 
of ctFDDINMConfig to a particular SMT and MAC instance in
the 1512 FDDI MIB.
ctFDDINonMuxConnectionEntry row .1.3.6.1.4.1.52.4.1.2.5.1.2.3.1
Defines a specific configuration connection entry.
Column Syntax OID
A specific slot for which this connection entry is
defined.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.1
Describes a specific connection identifier. Valid
connection identifiers are defined by the third
sub-identifier in ctFDDINMConfig as identified by
ctFDDINMCapEnable.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.2
ctFDDINMSMTmandatory
A specific instance of SMT for which this entry pertains.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.3
ctFDDINMMACmandatory
A specific MAC that this connection entry pertains.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.4
ctFDDINMBytesmandatory
The bandwidth utilization in bytes per second.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.5
The bandwidth utilization in frames per second.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.3.1.6

ctFDDINonMuxInterfaceTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.2.4 · 1 row entry · 2 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDINonMuxInterfaceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDINonMuxInterfaceTable'
This table describs the number of interfaces defined by
each non multiplexing FDDI FNB module.
ctFDDINonMuxInterfaceEntry row .1.3.6.1.4.1.52.4.1.2.5.1.2.4.1
A specfic non multiplexing module interface definition.
Column Syntax OID
A specific slot for which this inteface entry is
defined.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.1
The number of interfaces defined on this particular
module.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.2.4.1.2

ctFDDIMuxCapTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.3.1 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDIMuxCapTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDIMuxCapTable'
This table describes all possible configuration/capabilities
defined for a FDDI multiplexing module.
ctFDDIMuxCapEntry row .1.3.6.1.4.1.52.4.1.2.5.1.3.1.1
Describes a specfic FDDI multiplexor capability/configuration
entry.
Column Syntax OID
ctFDDIMuxSlotmandatory
Defines the slot within the chassis for which this
multiplexed capability/configuration entry pertains.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.1
The instance of a particular configuration.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.2
This object defines a specific valid connection
configuration. It will specify the connection state of all
resource instances. If an instance of a resource is
not specified, then it is disconnected.

Eac…
RFC1213-MIBDisplayString .1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.3
This object contains a textual description of a valid
connection configuration. This is a more user-friendly
representation of the configuration than the ctFDDIMuxConfig
object.
RFC1213-MIBDisplayString .1.3.6.1.4.1.52.4.1.2.5.1.3.1.1.4

ctFDDIMuxCapEnableTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.3.2 · 1 row entry · 3 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDIMuxCapEnableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDIMuxCapEnableTable'
This table describes the currently enabled configuration
for each module.
ctFDDIMuxCapEnableEntry row .1.3.6.1.4.1.52.4.1.2.5.1.3.2.1
Describes a specific configuration enable entry.
Column Syntax OID
A specific slot for which this configuration enable
pertains.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.1
A specific instance of the configuration that is
enabled.

Setting this object with a specific value of ctFDDIMuxConfigID
enabled that configuration. A request of the value of this
object will return the …
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.2
Depicts the number of changes to the master port to multiplexor
output mapping.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.52.4.1.2.5.1.3.2.1.3

ctFDDIMuxOutTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.3.3 · 1 row entry · 6 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDIMuxOutTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDIMuxOutTable'
Describes the multiplexor outputs for each of the
FNB multiplexor modules.  This maps the multiplexor output
to a specific instance of MAC and SMT in the FDDI MIB.
ctFDDIMuxOutEntry row .1.3.6.1.4.1.52.4.1.2.5.1.3.3.1
Describes a particular multiplexor output.
Column Syntax OID
The given slot for which this multiplexor output information
pertains.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.1
The specific instance of the multiplexor output. Instances
of this object are used by the values of ctFDDIMuxConfig.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.2
The MAC instance of this multiplexor output. If this
this object has a value greater than 0, then this
value is the same as fddimibMACIndex. If this object has the
value of 0, the given mux-out does not have a MAC.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.3
Identifies the instance of SMT as defined within the
FDDI MIB.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.4
The bandwidth utilization in bytes per second.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.5
The bandwidth utilization in frames per second.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.3.3.1.6

ctFDDIMuxMasterPortTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.3.4 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDIMuxMasterPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDIMuxMasterPortTable'
A list of entries that define master ports as they are
defined for the given multiplexed FDDI connection.
ctFDDIMuxMasterPortEntry row .1.3.6.1.4.1.52.4.1.2.5.1.3.4.1
A specific FDDI-FNB multiplexed master port definition.
Column Syntax OID
A specific instance of a slot as defined by chSlotID.
Integer32
Constraints:
range: 1-255
.1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.1
A unique identifier for this specific master port.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.2
Provides the masterport to multiplexor output mapping.
This is as defined by ctFDDIMuxOutMacAssignment.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.3
Defines a specific port within the FDDI MIBs fddimibPORTTable.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.52.4.1.2.5.1.3.4.1.4

ctFDDISerialConfigTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.4.2 · 1 row entry · 3 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDISerialConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDISerialConfigTable'
This table describes the adminstrative control over each
of the FNB serial control modules.
ctFDDISerialConfigEntry row .1.3.6.1.4.1.52.4.1.2.5.1.4.2.1
Describes the controls over a single FNB serial control
entry.
Column Syntax OID
Defines the slot that this FNB serial control module is in.
This is an instance of chSlotID as defined in the chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.1
Describes the adminstrative desired state for this FNB
serial control module.

insertFNB1(1) - The serial controlled module should be
inserted into FNB-1 and bypass FNB-2.

Enumerationr/w
Enumerated Values:
1insertFNB1
2insertFNB2
3insertFNB1FNB2
4bypass
5hwControlFNB1
6hwControlFNB2
7hwControl
.1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.2
Describes the operational status of this FDDI serial
controlled module.

insertFNB1(1) - The serial controlled module is
inserted into FNB-1 and bypassed from FNB-2.

Enumeration
Enumerated Values:
1insertFNB1
2insertFNB2
3insertFNB1FNB2
4bypass
.1.3.6.1.4.1.52.4.1.2.5.1.4.2.1.3

ctFDDIModuleFPIMTable

table mandatory
.1.3.6.1.4.1.52.4.1.2.5.1.4.3 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk ctFDDIModuleFPIMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-FDDI-FNB-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-FDDI-FNB-MIB::ctFDDIModuleFPIMTable'
This table describes the FPIMs that are on the front panel of
each FDDI serial control module, if that module supports FPIMs.
ctFDDIModuleFPIMEntry row .1.3.6.1.4.1.52.4.1.2.5.1.4.3.1
Describes a single FDDI FPIM on a module.
Column Syntax OID
Defines the slot in which this module exists. This
is an instance of chSlotID as found in the chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.1
ctFddiFPIMmandatory
Defines the instance of the port for which this definition
is made. Ports are physically located from top-to-bottom on a
particular module. If there are multiple 'columns' of ports
from the top to the bottom, then the…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.2
Describes the link status of the given FPIM.

A value of link(1) states that a link is present.

A value of noLink(2) states that no link is present.

A value of notSupported(3)…
Enumeration
Enumerated Values:
1link
2noLink
3notSupported
.1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.4
Describes the type of FPIM as found in ctron-oids.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.2.5.1.4.3.1.5