CTRON-ENVIRONMENT-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
3
Rows
3
Columns
27
.1.3.6.1.4.1.52.4.1.1.8.1.12
·
1 row entry
·
4 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk chEnvFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-ENVIRONMENT-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-ENVIRONMENT-MIB::chEnvFanTable'
A list of fans installed in this chassis.
A slot entry containing objects for a particular
module.
module.
Indexes
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
chEnvFanIDmandatory A unique value, in the range between 1 and and the value of chEnvNumFans. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.1.12.1.1 | ||||||||||||
chEnvFanStatusmandatory This object reflects the status of the chassis fan. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.1.12.1.2 | ||||||||||||
chEnvFanAdminmandatory This object is used to select the operational mode of the fan. If the value is set to 1 (auto) then fan speed is based on temperature. If the value is set to 3 (testing) then value will return to it's previous value … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.1.12.1.3 | ||||||||||||
chEnvFanSpeedmandatory The fan speed expressed as a percentage of the maximum fan speed. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.1.12.1.4 |
.1.3.6.1.4.1.52.4.1.1.8.2.1
·
1 row entry
·
13 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk boardEnvSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-ENVIRONMENT-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-ENVIRONMENT-MIB::boardEnvSlotTable'
A list of networking modules installed in this chassis.
A slot entry containing objects for a particular
module.
module.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
boardEnvSlotIDmandatory The slot number of a chassis slot in which this board isinstalled. This object is similiar to chSlotID in the Chassis MIB. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.1 | ||||||||||||||
boardEnvTempmandatory The temperature of the networking board. If this sensor is broken or not supported, then this object will be set to zero. The temperature is in degrees Fahrenheit * 10. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.2 | ||||||||||||||
boardEnvTempStatusmandatory This object reflects the status of the board temperaturereading. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.2.1.1.3 | ||||||||||||||
boardEnvTempRelStatusmandatory This object reflects the status of the board temperaturereading relative to the ambient temperature. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.2.1.1.4 | ||||||||||||||
boardEnvShutdownAdminmandatory This object enables or disables the auto shutdown dueto a temperature condition. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.2.1.1.5 | ||||||||||||||
boardEnvTempHotmandatory The temperature value above which the board temperatureis deemed to be hot. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.6 | ||||||||||||||
boardEnvTempWarmmandatory The temperature value above which the board temperatureis deemed to be warm, if it is below or equal the hot value. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.7 | ||||||||||||||
boardEnvTempCoolmandatory The temperature value below which the board temperatureis deemed to be cool, if it is above or equal the cold value. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.8 | ||||||||||||||
boardEnvTempColdmandatory The temperature value below which the board temperatureis deemed to be cold. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.9 | ||||||||||||||
boardEnvTempRelHotmandatory The temperature value above ambient at which the boardtemperature is deemed to be hot relative to ambient. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.10 | ||||||||||||||
boardEnvTempRelWarmmandatory The temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvTempRelHot. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.11 | ||||||||||||||
boardEnvTempMaxFanRelHotmandatory The temperature value above ambient at which the boardtemperature is deemed to be hot relative to ambient, with all fans in the chassis running at there maximum speed. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.12 | ||||||||||||||
boardEnvTempMaxFanRelWarmmandatory The temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvTempMaxFanRelHot, with all fans in the chassis running at th… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.2.1.1.13 |
.1.3.6.1.4.1.52.4.1.1.8.3.1
·
1 row entry
·
10 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk psEnvSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-ENVIRONMENT-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-ENVIRONMENT-MIB::psEnvSlotTable'
A list of networking modules installed in this chassis.
A slot entry containing objects for a particular
module.
module.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psEnvSlotIDmandatory The slot number of a chassis slot in which this power supplyis installed. An unique value, in the range between 1 and and the value of chNumSlots. This object is similiar to chSlotID in the Chassis MIB. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.1 | ||||||||||||||
psEnvTempmandatory The temperature of the power supply. If this sensor is broken or not supported, then this object will be set to zero. The temperature is in degrees Fahrenheit * 10. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.2 | ||||||||||||||
psEnvTempStatusmandatory This object reflects the status of the power supplytemperature reading. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.3.1.1.3 | ||||||||||||||
psEnvTempHotmandatory The temperature value above which the power supplytemperature is deemed to be hot. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.4 | ||||||||||||||
psEnvTempWarmmandatory The temperature value above which the power supply temperature is deemed to be warm, if it is below or equal the hot value. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.5 | ||||||||||||||
psEnvTempCoolmandatory The temperature value below which the power supply temperature is deemed to be cool, if it is above or equal the cold value. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.6 | ||||||||||||||
psEnvTempColdmandatory The temperature value below which the power supplytemperature is deemed to be cold. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.7 | ||||||||||||||
psEnvFanStatusmandatory This object reflects the status of the chassis fan. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.3.1.1.8 | ||||||||||||||
psEnvFanAdminmandatory This object is used to select the operational mode of the fan. If the value is set to 1 (auto) then fan speed is based on temperature. If the value is set to 3 (testing) then value will return to it's previous value … | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.52.4.1.1.8.3.1.1.9 | ||||||||||||||
psEnvFanSpeedmandatory The fan speed expressed as a percentage of the maximum fan speed. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.52.4.1.1.8.3.1.1.10 |