CTRON-ENVIRONMENT-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
3
Rows
3
Columns
27

chEnvFanTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.8.1.12 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk chEnvFanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-ENVIRONMENT-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-ENVIRONMENT-MIB::chEnvFanTable'
A list of fans installed in this chassis.
chEnvFanEntry row .1.3.6.1.4.1.52.4.1.1.8.1.12.1
A slot entry containing objects for a particular
module.
Indexes
Column Syntax OID
chEnvFanIDmandatory
A unique value, in the range between 1 and and the
value of chEnvNumFans.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.1.12.1.1
This object reflects the status of the chassis fan.
Enumeration
Enumerated Values:
1unknown
2normal
3testing
4slow
5inoperative
6off
.1.3.6.1.4.1.52.4.1.1.8.1.12.1.2
chEnvFanAdminmandatory
This object is used to select the operational mode of the
fan. If the value is set to 1 (auto) then fan speed is
based on temperature. If the value is set to 3 (testing)
then value will return to it's previous value …
Enumerationr/w
Enumerated Values:
1autoMode
2fullSpeed
3testingMode
.1.3.6.1.4.1.52.4.1.1.8.1.12.1.3
chEnvFanSpeedmandatory
The fan speed expressed as a percentage of the maximum
fan speed.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.1.12.1.4

boardEnvSlotTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.8.2.1 · 1 row entry · 13 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk boardEnvSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-ENVIRONMENT-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-ENVIRONMENT-MIB::boardEnvSlotTable'
A list of networking modules installed in this chassis.
boardEnvSlotEntry row .1.3.6.1.4.1.52.4.1.1.8.2.1.1
A slot entry containing objects for a particular
module.
Indexes
Column Syntax OID
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.1
boardEnvTempmandatory
The temperature of the networking board. If this sensor is
broken or not supported, then this object will be set to
zero. The temperature is in degrees Fahrenheit * 10.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.2
This object reflects the status of the board temperature
reading.
Enumeration
Enumerated Values:
1unknown
2cold
3cool
4normal
5warm
6hot
7inoperative
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.3
This object reflects the status of the board temperature
reading relative to the ambient temperature.
Enumeration
Enumerated Values:
1unknown
2normal
3warm
4hot
5inoperative
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.4
This object enables or disables the auto shutdown due
to a temperature condition.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.5
The temperature value above which the board temperature
is deemed to be hot.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.6
The temperature value above which the board temperature
is deemed to be warm, if it is below or equal the hot
value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.7
The temperature value below which the board temperature
is deemed to be cool, if it is above or equal the cold
value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.8
The temperature value below which the board temperature
is deemed to be cold.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.9
The temperature value above ambient at which the board
temperature is deemed to be hot relative to ambient.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.10
The temperature value above ambient at which the board
temperature is deemed to be warm relative to ambient, if
it is below the relative hot value of boardEnvTempRelHot.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.11
The temperature value above ambient at which the board
temperature is deemed to be hot relative to ambient, with
all fans in the chassis running at there maximum speed.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.12
The temperature value above ambient at which the board
temperature is deemed to be warm relative to ambient, if
it is below the relative hot value of boardEnvTempMaxFanRelHot,
with all fans in the chassis running at th…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.2.1.1.13

psEnvSlotTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.8.3.1 · 1 row entry · 10 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk psEnvSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-ENVIRONMENT-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-ENVIRONMENT-MIB::psEnvSlotTable'
A list of networking modules installed in this chassis.
psEnvSlotEntry row .1.3.6.1.4.1.52.4.1.1.8.3.1.1
A slot entry containing objects for a particular
module.
Indexes
Column Syntax OID
psEnvSlotIDmandatory
The slot number of a chassis slot in which this power supply
is installed. An unique value, in the range between 1 and
and the value of chNumSlots. This object is similiar to
chSlotID in the Chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.1
psEnvTempmandatory
The temperature of the power supply. If this sensor is
broken or not supported, then this object will be set to
zero. The temperature is in degrees Fahrenheit * 10.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.2
This object reflects the status of the power supply
temperature reading.
Enumeration
Enumerated Values:
1unknown
2cold
3cool
4normal
5warm
6hot
7inoperative
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.3
psEnvTempHotmandatory
The temperature value above which the power supply
temperature is deemed to be hot.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.4
psEnvTempWarmmandatory
The temperature value above which the power supply
temperature is deemed to be warm, if it is below or
equal the hot value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.5
psEnvTempCoolmandatory
The temperature value below which the power supply
temperature is deemed to be cool, if it is above or
equal the cold value.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.6
psEnvTempColdmandatory
The temperature value below which the power supply
temperature is deemed to be cold.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.7
This object reflects the status of the chassis fan.
Enumeration
Enumerated Values:
1unknown
2normal
3testing
4slow
5inoperative
6off
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.8
psEnvFanAdminmandatory
This object is used to select the operational mode of the
fan. If the value is set to 1 (auto) then fan speed is
based on temperature. If the value is set to 3 (testing)
then value will return to it's previous value …
Enumerationr/w
Enumerated Values:
1autoMode
2fullSpeed
3testingMode
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.9
psEnvFanSpeedmandatory
The fan speed expressed as a percentage of the maximum
fan speed.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.8.3.1.1.10