cpqWcrmInternalSensorTable

table mandatory
.1.3.6.1.4.1.232.167.2.3.5.2 · 1 row entry · 10 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmInternalSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmInternalSensorTable'
Headline of sensor table
cpqWcrmInternalSensorEntry row .1.3.6.1.4.1.232.167.2.3.5.2.1
Entries of sensor table
Column Syntax OID
Index for the list of value entries. Its value ranges
between 1 and the value of cpqWcrmInternalNumberOfSensors.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.2.3.5.2.1.1
Type of sensor which is connected to internal sensor to sensor[internalSensorIndex]
1: no sensor connected
2: sensor failure
3: value overflow
4: sensor type 1, access sensor
5: sensor…
Enumeration
Enumerated Values:
1notAvail
2failure
3overflow
4access
5vibration
6motion
7smoke
8airFlow
9type6
10temperature
11current4to20
12humidity
13userNO
14userNC
17voltOK
18voltage
19fanOK
20leakage
.1.3.6.1.4.1.232.167.2.3.5.2.1.2
Descriptional text for each sensor (entry in the table)
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.232.167.2.3.5.2.1.3
Actual status of the sensor
Enumeration
Enumerated Values:
1notAvail
2lost
3changed
4ok
5off
6on
7warning
8tooLow
9tooHigh
.1.3.6.1.4.1.232.167.2.3.5.2.1.4
Value of sensor
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.5.2.1.5
Value for high setpoint of sensor
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.5.2.1.6
Value for low setpoint of sensor,
also used as alarm delay
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.5.2.1.7
Value for warning setpoint of sensor,
also used as fan threshold
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.5.2.1.8
Scaling factor for scaled sensor value, e. g.
-100 -> value has to be divided by 100
+100 -> value has to be multiplied by 100.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.5.2.1.9
Scaled value of sensor
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.5.2.1.10

cpqWcrmInternalOutputTable

table mandatory
.1.3.6.1.4.1.232.167.2.3.6.2 · 1 row entry · 9 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmInternalOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmInternalOutputTable'
Headline of output table
cpqWcrmInternalOutputEntry row .1.3.6.1.4.1.232.167.2.3.6.2.1
Entries of output table
Column Syntax OID
Index for the list of output entries. Its value ranges
between 1 and the value of cpqWcrmInternalNumberOfOutputs.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.2.3.6.2.1.1
Type of output which is connected to internal sensor to output[internalOutputIndex]
1: no output connected
2: output failure
3: value overflow
4: output type 6, universal relay output
5: …
Enumeration
Enumerated Values:
1notAvail
2failure
3overflow
4universalOut
5powerOut
.1.3.6.1.4.1.232.167.2.3.6.2.1.2
Descriptional text for each output (entry in the table)
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.232.167.2.3.6.2.1.3
Actual status of the output
Enumerationr/w
Enumerated Values:
1notAvail
2lost
3changed
4ok
5off
6on
7setOff
8setOn
.1.3.6.1.4.1.232.167.2.3.6.2.1.4
Value for output
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.6.2.1.5
Command for output
Enumerationr/w
Enumerated Values:
1off
2on
3lock
4unlock
5unlockDelay
.1.3.6.1.4.1.232.167.2.3.6.2.1.6
Configuration for output
1: disable remote control (e.g. keypad)
2: enable remote control
Enumerationr/w
Enumerated Values:
1disRemote
2enRemote
.1.3.6.1.4.1.232.167.2.3.6.2.1.7
Unsigned Value for delay,
after this time the output will fall into the previous state
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.3.6.2.1.8
State for output if timeout (RS422) occurs
Enumerationr/w
Enumerated Values:
1stay
2off
3on
.1.3.6.1.4.1.232.167.2.3.6.2.1.9

cpqWcrmInternalMsgTable

table mandatory
.1.3.6.1.4.1.232.167.2.3.7.2 · 1 row entry · 10 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmInternalMsgTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmInternalMsgTable'
Headline of message table
cpqWcrmInternalMsgEntry row .1.3.6.1.4.1.232.167.2.3.7.2.1
Entries of message table
Column Syntax OID
Index for the list of message entries. Its value ranges
between 1 and the value of cpqWcrmInternalNumberOfMsgs.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.2.3.7.2.1.1
Descriptional text for each message (entry in the table)
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.232.167.2.3.7.2.1.2
Actual message status
1: not available
2: configuration has changed (sensor new, changed, lost)
3: error
4: OK
5: alarm, e.g. smoke, vibration...
6: warning of analog value, value reached warning threshold
7: analog val…
Enumeration
Enumerated Values:
1notAvail
2configChanged
3error
4ok
5alarm
6warning
7tooLow
8tooHigh
9setOff
10setOn
.1.3.6.1.4.1.232.167.2.3.7.2.1.3
Setup of Alarm relay for this message/alarm
1: no switching of alarm relay
2: switching of alarm relay
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.3.7.2.1.4
Setup of Alarm beeper for this alarm
1: no audible alarm
2: audible alarm
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.3.7.2.1.5
Trap receiver 1 activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.3.7.2.1.6
Trap receiver 2 activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.3.7.2.1.7
Trap receiver 3 activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.3.7.2.1.8
Trap receiver 4 and Event Logging activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.3.7.2.1.9
Reset of this alarm
1: auto
2: manual, alarm needs confirmation, e. g. with 'C' key
Enumerationr/w
Enumerated Values:
1auto
2manual
.1.3.6.1.4.1.232.167.2.3.7.2.1.10
.1.3.6.1.4.1.232.167.2.4.5.2 · 1 row entry · 10 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmWaterCoolUnitSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmWaterCoolUnitSensorTable'
Headline of sensor table
cpqWcrmWaterCoolUnitSensorEntry row .1.3.6.1.4.1.232.167.2.4.5.2.1
Entries of sensor table
Column Syntax OID
Index for the list of value entries. Its value ranges
between 1 and the value of cpqWcrmWaterCoolUnitNumberOfSensors.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.2.4.5.2.1.1
Type of sensor which is connected to internal sensor to sensor[internalSensorIndex]
1: no sensor connected -- Type 1 is not reported by the agent in this table.
2: sensor failure -- Type 2 is not reported by the a…
Enumeration
Enumerated Values:
4tempIn
5tempOut
6heatFlow
7alarm
8warning
9rpmFan1
10rpmFan2
11rpmFan3
12fanSpeed
13tempIn1
14tempOut1
15tempIn2
16tempOut2
17tempIn3
18tempOut3
19tempWaterIn
20tempWaterOut
21waterFlow
22valve
23status
24condensateDuration
25condensateCycles
26rpmFan4
27rpmFan5
28rpmFan6
29transfSwitch
30valveActValue
31dewPointValue
32foundFans
33isolationValveInlet
34isolationValveFacility
35isolationValveInfrastructure
36controlValveFacility
37controlValveInfrastructure
38tempIn4
39tempIn5
40tempIn6
41waterPressureSupply
42waterPressureReturn
43airDiffPressure1
44airDiffPressure2
45acInput1
46acInput2
47frontDoor
48rearDoor
49leakMidLevel
50leakOverflow1
51leakOverflow2
52condensate
53dewPointValue2
54humidityValue
55humidityValue2
56pump
57tempeValue1
58tempeValue2
59dewPointAverage
60percentFan1
61percentFan2
62percentFan3
63percentFan4
64percentFan5
65percentFan6
.1.3.6.1.4.1.232.167.2.4.5.2.1.2
Descriptional text for each sensor (entry in the table)
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.232.167.2.4.5.2.1.3
Actual status of the sensor
Enumeration
Enumerated Values:
1notAvail
2lost
3changed
4ok
5off
6on
7warning
8tooLow
9tooHigh
.1.3.6.1.4.1.232.167.2.4.5.2.1.4
Value of sensor added to traps, msg index also added (waterCoolUnitMsgIndex)

If msg index = 1, 5 or 6
This value represents the actual Server Intake Temperature.

If msg index = 2:
This valu…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.5.2.1.5
Value for high setpoint of sensor
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.5.2.1.6
Value for low setpoint of sensor,
also used as alarm delay
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.5.2.1.7
Value for warning setpoint of sensor,
also used as fan threshold
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.5.2.1.8
Scaling factor for scaled sensor value to get the unscaled value, e. g.
-100 -> waterCoolUnitSensorScaledValue has to be divided by 100
+100 -> waterCoolUnitSensorScaledValue has to be multiplied by 100.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.5.2.1.9
Scaled value of sensor
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.5.2.1.10
.1.3.6.1.4.1.232.167.2.4.6.2 · 1 row entry · 9 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmWaterCoolUnitOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmWaterCoolUnitOutputTable'
Headline of output table
cpqWcrmWaterCoolUnitOutputEntry row .1.3.6.1.4.1.232.167.2.4.6.2.1
Entries of output table
Column Syntax OID
Index for the list of output entries. Its value ranges
between 1 and the value of cpqWcrmWaterCoolUnitNumberOfOutputs.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.2.4.6.2.1.1
Type of output which is connected to water cool unit to output[waterCoolUnitOutputIndex]
1: no output connected
2: output failure
3: value overflow
4: water valve setpoint
5: water valve hysteresis
6: command for man…
Enumeration
Enumerated Values:
1notAvail
2failure
3overflow
4setpoint
5hysteresis
6command
7controlMode
8fanSpeedMin
9dTmin
10dTmax
11cpWatert
12setHeatload
13setEdoFlow
14setEdoHeat
15setCondCycles
16setCondRun
17doorControl
18pidContrKP
19pidContrKI
20pidContrKD
21pidSampleTime
22installedFans
23offsetCW
24offsetHW
25valveControlMode
26isolationValveInletManual
27isolationValveFacilityManual
28isolationValveInfrastructureManual
29controlValveFacilityManual
30controlValveInfrastructureManual
31fanControlMode
32fan1Manual
33fan2Manual
34fan3Manual
35fan4Manual
36setpointAirDifPressure
37pidContrKPFan
38pidContrKIFan
39pidContrKDFan
40pidSampleTimeFan
41dewpointOffset
42maxItAirTemperature
43dewpointControlMode
.1.3.6.1.4.1.232.167.2.4.6.2.1.2
Descriptional text for each output (entry in the table)
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.232.167.2.4.6.2.1.3
Actual status of the output
Enumerationr/w
Enumerated Values:
1notAvail
2lost
3changed
4ok
5off
6on
7setOff
8setOn
.1.3.6.1.4.1.232.167.2.4.6.2.1.4
Signed value for output
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.6.2.1.5
Command for output
Enumerationr/w
Enumerated Values:
1off
2on
3lock
4unlock
5unlockDelay
.1.3.6.1.4.1.232.167.2.4.6.2.1.6
Configuration for output
1: disable remote control (e.g. keypad)
2: enable remote control
Enumerationr/w
Enumerated Values:
1disRemote
2enRemote
.1.3.6.1.4.1.232.167.2.4.6.2.1.7
Unsigned Value for delay,
after this time the output will fall into the previous state
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.167.2.4.6.2.1.8
State for output if timeout (RS422) occurs
Enumerationr/w
Enumerated Values:
1stay
2off
3on
.1.3.6.1.4.1.232.167.2.4.6.2.1.9
.1.3.6.1.4.1.232.167.2.4.7.2 · 1 row entry · 10 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmWaterCoolUnitMsgTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmWaterCoolUnitMsgTable'
Headline of message table
cpqWcrmWaterCoolUnitMsgEntry row .1.3.6.1.4.1.232.167.2.4.7.2.1
Entries of message table
Column Syntax OID
Index for the list of alarm entries. Its value ranges
between 1 and the value of cpqWcrmWaterCoolUnitNumberOfMsgs.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.2.4.7.2.1.1
Descriptional text for each message (entry in the table)
OctetStringr/w
Constraints:
range: 0-20
.1.3.6.1.4.1.232.167.2.4.7.2.1.2
Actual message status
4: OK
5: alarm
6: warning
7: analog value too low, value reached low threshold
8: analog value too high, value reached high threshold
Enumeration
Enumerated Values:
1notAvail
2configChanged
3error
4ok
5alarm
6warning
7tooLow
8tooHigh
9setOff
10setOn
.1.3.6.1.4.1.232.167.2.4.7.2.1.3
Setup of Alarm relay for this alarm
2: no switching of alarm relay
1: switching of alarm relay
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.4.7.2.1.4
Setup of Alarm beeper for this alarm
2: no audible alarm
1: audible alarm
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.4.7.2.1.5
Trap receiver 1 activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.4.7.2.1.6
Trap receiver 2 activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.4.7.2.1.7
Trap receiver 3 activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.4.7.2.1.8
Trap receiver 4 and Event Logging activated
Enumerationr/w
Enumerated Values:
1disable
2enable
.1.3.6.1.4.1.232.167.2.4.7.2.1.9
Reset of this alarm
1: auto
2: manual, alarm needs confirmation, e. g. with 'C' key
Enumerationr/w
Enumerated Values:
1auto
2manual
.1.3.6.1.4.1.232.167.2.4.7.2.1.10

cpqWcrmTimerTable

table mandatory
.1.3.6.1.4.1.232.167.3.1.8.2 · 1 row entry · 7 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmTimerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmTimerTable'
Headline of status-table
cpqWcrmTimerEntry row .1.3.6.1.4.1.232.167.3.1.8.2.1
Entries of timer-table
Column Syntax OID
Index for the list of timer entries. Its value ranges
between 1 and the value of cpqWcrmTimerNumber.
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.3.1.8.2.1.1
Actual status of the timer
Enumeration
Enumerated Values:
1switchedOff
2switchedOn
3noTime
.1.3.6.1.4.1.232.167.3.1.8.2.1.2
Selection of day of week for timer to switch
Enumerationr/w
Enumerated Values:
1sun
2mon
3tue
4wed
5thu
6fri
7sat
8sat-sun
9mon-fri
10mon-sun
.1.3.6.1.4.1.232.167.3.1.8.2.1.3
cpqWcrmTimeOnmandatory
Time to switch on current function,
Format: HH:MM
OctetStringr/w
Constraints:
range: 0-5
.1.3.6.1.4.1.232.167.3.1.8.2.1.4
Time to switch off current function,
Format: HH:MM
OctetStringr/w
Constraints:
range: 0-5
.1.3.6.1.4.1.232.167.3.1.8.2.1.5
Control via RTC
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.232.167.3.1.8.2.1.6
Function which is controlled via timer
1-4: sending Traps to this Trap receiver will be disabled
5 - 8: scheduled alarm off
Enumerationr/w
Enumerated Values:
1disTrapRec1
2disTrapRec2
3disTrapRec3
4disTrapRec4
5schedule1
6schedule2
7schedule3
8schedule4
.1.3.6.1.4.1.232.167.3.1.8.2.1.7

cpqWcrmTrapTableTable

table mandatory
.1.3.6.1.4.1.232.167.4.7.2 · 1 row entry · 4 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqWcrmTrapTableTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQWCRM-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQWCRM-MIB::cpqWcrmTrapTableTable'
A list of trap-receiver entries
cpqWcrmTrapTableEntry row .1.3.6.1.4.1.232.167.4.7.2.1
Entries of trapTable
Indexes
Column Syntax OID
trapIndexmandatory
Index for the trap-receiver-table. Its value ranges between
1 and the value of traptableNumber
Integer32
Constraints:
range: 1-65535
.1.3.6.1.4.1.232.167.4.7.2.1.1
trapStatusmandatory
Enable or disable trap receiver
Enumerationr/w
Enumerated Values:
1disabled
2enabled
.1.3.6.1.4.1.232.167.4.7.2.1.2
trapIPaddressmandatory
IP-address of trap-receiver
OctetStringr/w
Constraints:
range: 0-15
.1.3.6.1.4.1.232.167.4.7.2.1.3
IP-address of trap-receiver
OctetStringr/w
Constraints:
range: 0-64