ager board failure.
The Insight Agent has detected a failure of the Compaq Server
Manager/R board in the server.
cpqSmBoardReset
.1.3.6.1.4.1.232.4.0.2
ager board reset.
The Insight Agent has detected a reset of the Server Manager/R
board in the server.
cpqSmServerManagerAlert
.1.3.6.1.4.1.232.4.0.3
exeeded on Server Manager monitored item.
The Insight Agent has detected a monitored item on the Server
Manager board exceeding a threshold when alerting is
enabled for the monitored item.
cpqSmCommFailed
.1.3.6.1.4.1.232.4.0.4
ager asynchronous communications failure.
The Insight Agent has detected a failure in the Server Manager
board's asynchronous communication system.
cpqSmBatteryFailed
.1.3.6.1.4.1.232.4.0.5
ager battery failure.
The Insight Agent has detected a failure in the Server Manager
board's onboard battery.
cpqSmBoardTimeout
.1.3.6.1.4.1.232.4.0.6
ager board time-out.
The Insight Agent has detected a time-out of the Server
Manager board as reported by the Server Manager Board driver.
cpqSmAlertDestinationBlacklisted
.1.3.6.1.4.1.232.4.0.7
ination blacklisted.
The Server Manager board modem has blacklisted an alert
destination phone number. Once blacklisted, that alert
destination is no longer available for use as an alert
destination. Blacklisting, which only occurs in
international modems, is a requirement imposed by certain
European countries on modems, to prevent a phone number
from being dialed multiple times without getting a connection.
The number of attempts required to have blacklisting occur,
vary from country to country. Once an alert destination has
been blacklisted, the only way to remove the blacklisted phone
number is to remove power from the modem.
On external modems this is a trival task. When a blacklisting
occurs on the Server Manager board's internal modem the
task is slightly more difficult as the modem gets power
from the Server Manager board.
To remove power from the Server Manager board's internal modem,
the Server Manager board must be forced into Dormant Mode.
This is an operating mode, used to conserve battery life,
which is entered automatically if the board looses power.
To cause the board to enter Dormant Mode, the following
steps should be performed:
1) Disable alerting via CPQCAUI.NLM.
2) Disable async communication via CPQCAUI.NLM.
3) Down the server.
4) Exit to DOS (if applicable).
5) Shut power off to the computer.
6) Wait 5 minutes before restoring power.
Once the 5 minutes has expired, and power to the computer
has been restored, the modem will have flushed its
blacklist, and the board's alerting functions will work
as expected.