d is removed.
The hood status has been detected as removed. The
system`s hood is not in a properly installed state. This
situation may result in improper cooling of the system due
to air flow changes caused by the missing hood.
cpqSiMonitorConditionOK
.1.3.6.1.4.1.232.0.2002
rting features have returned to within their normal
operating range for the monitor indicated by cpqSiMonitorIndex.
The monitor`s condition has been set to OK.
User Action: None.
cpqSiMonitorConditionDegraded
.1.3.6.1.4.1.232.0.2003
porting feature has exceeded normal limits for
the monitor indicated by the cpqSiMonitorIndex. The monitor`s
condition is degraded due to the internal temperature exceeding
normal operating limits. The monitor is still useable, but
action should be taken to return the condition to OK.
User Action: Physically check for obstructions to air flow around
the monitor. Check the thermostat in the room that the system
occupies. Allow the monitor to cool by turning off the monitor
for 5 minutes then turn the monitor back on. After the monitor
cools, another alarm indicating an improving condition, such as
Monitor OK, will be issued.
cpqSiMonitorConditionFailed
.1.3.6.1.4.1.232.0.2004
porting feature has exceeded normal limits in the
monitor indicated by the cpqSiMonitorIndex. The monitor`s
condition has been set to failed due to an operational feature
exceeding normal operating limits. The monitor will not be
useable and should be replaced.
User Action: Make a note of the monitor model number and serial
number. Replace the monitor.
Refer to the appropriate Maintenance and Service Guide for
detailed information on a component replacement.
cpqSiCorrMemErrStatusDegraded
.1.3.6.1.4.1.232.0.2005
e memory error count has exceeded the threshold for the
memory module indicated by the `cpqSiMemErrorIndex` variable.
The appropriate cpqSiMemModuleECCStatus has been set to degraded.
User Action: For Desktops, the System Administrator should run
the F10 Diagnostics on this system and select RAM LONG TEST. If
it is determined that a module needs replacing, schedule
maintenance for the system and replace the failed memory module.
Refer to the appropriate Maintenance and Service Guide for detailed
information on a component replacement.
cpqSiCorrMemErrStatusOk
.1.3.6.1.4.1.232.0.2006
e memory error count is now below the threshold for the
memory module indicated by the `cpqSiMemErrorIndex` variable. The
appropriate cpqSiMemModuleECCStatus has been set to ok.
User Action: None.
cpqSiMemConfigChange
.1.3.6.1.4.1.232.0.2007
onfiguration change has occurred. CpqSiMemConfigChangeData
will indicate which memory modules slots have changed.
User Action: You may want to verify a valid reason for a memory
configuration to have occurred. If system issuing the alert is
a Desktop running NT, the memory configuration change information
is also logged in the NT System Log.
cpqSiHotPlugSlotBoardRemoved
.1.3.6.1.4.1.232.0.2008
lot Board Removed.
A Hot Plug Slot Board has been removed from the specified
chassis and slot.
User Action: None.
cpqSiHotPlugSlotBoardInserted
.1.3.6.1.4.1.232.0.2009
lot Board Inserted.
A Hot Plug Slot Board has been inserted into the specified
chassis and slot.
User Action: None.
cpqSiHotPlugSlotPowerUpFailed
.1.3.6.1.4.1.232.0.2010
lot Board Failed Power-Up.
A Hot Plug Slot Board has failed to power-up in the specified
chassis and slot.
User Action: Insure the board and all cables are installed
correctly and the board type and revision are the same as
the replaced board.
cpqSiSysBatteryFailure
.1.3.6.1.4.1.232.0.2011
y indicated by cpqSiSysBatteryIndex has failed
and must be replaced.
User Action: Contact your System Administrator or
Authorized Reseller to order a replacement battery.
Recycle your old battery. For proper disposal information,
refer to the documentation that came with your computer.
cpqSiSysBatteryChargingDegraded
.1.3.6.1.4.1.232.0.2012
t battery degradation has occurred with battery
indicated by cpqSiSysBatteryIndex. The battery can
no longer be fully recharged.
User Action: If using multiple batteries, run
the Power Conservation Utility to identify the
battery location. Contact your System Administrator
or Authorized Reseller to order a replacement
battery.
cpqSiSysBatteryCalibrationError
.1.3.6.1.4.1.232.0.2013
n is needed with battery
indicated by cpqSiSysBatteryIndex. The battery can
not correctly indicate capacity.
User Action: Run the Power Conservation Utility. Contact
your System Administrator or Authorized Reseller to
order a replacement battery.
cpqSiIntrusionInstalled
.1.3.6.1.4.1.232.0.2014
System intrusion alert hardware is installed.
cpqSiIntrusionRemoved
.1.3.6.1.4.1.232.0.2015
System intrusion alert hardware is removed.
cpqSiHoodReplaced
.1.3.6.1.4.1.232.0.2016
System hood has been replaced.
cpqSiHoodRemovedOnPowerOff
.1.3.6.1.4.1.232.0.2017
BIOS detected a system hood removal when server power was off.
cpqSiSysTelemetryThresholdAlert
.1.3.6.1.4.1.232.0.2018
The system telemetry metric value has either exceeded upper threshold or is below lower threshold.