CPQNIC-MIB
- Source file
CPQNIC-MIB- Last revised
- Not declared
Imported Objects
| CPQHOST-MIB | compaq cpqHoTrapFlags |
| CPQSINFO-MIB | cpqSiServerSystemId |
| CPQSTDEQ-MIB | cpqSePciSlotBoardName |
| RFC-1212 | OBJECT-TYPE (no object page) |
| RFC-1215 | TRAP-TYPE (no object page) |
| RFC1155-SMI | Counter Gauge TimeTicks |
| RFC1213-MIB | DisplayString ipAdEntAddr sysName |
Objects (109)
Showing 109 of 109 objects
Object legend
Object type
Icons distinguish tables, entry rows, columns, scalars, and structural nodes.
SNMPv2-TCTruthValue
Syntax
Blue badges identify the value syntax. Connected badges read as defining module and convention.
IF-MIBifIndex
Table index
Green identifies an index object; yellow names its module when the index is defined elsewhere.
r/w
deprecated
obsolete
Access and status
r/w means read-write. Grey labels mark definitions retained for compatibility.
OBS ✓
Observium use
The indicator appears only when Observium directly references that object.
ifOperStatus
.1.3.6.1.2.1…
Names and OIDs
Object names link to their detail pages. Hover or focus a linked name or badge for available definition details.
.1.3.6.1.4.1.232.18 |
||
.1.3.6.1.4.1.232.18.1 |
||
|
|
Integer32
|
.1.3.6.1.4.1.232.18.1.1 |
|
|
Integer32
|
.1.3.6.1.4.1.232.18.1.2 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.1.3 |
.1.3.6.1.4.1.232.18.2 |
||
.1.3.6.1.4.1.232.18.2.1 |
||
.1.3.6.1.4.1.232.18.2.1.4 |
||
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.1.4.1 |
|
|
.1.3.6.1.4.1.232.18.2.1.4.2 |
|
|
|
.1.3.6.1.4.1.232.18.2.1.4.2.1 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.1.4.2.1.1 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.1.4.2.1.2 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.1.4.2.1.3 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.1.4.2.1.4 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.1.4.2.1.5 |
.1.3.6.1.4.1.232.18.2.2 |
||
|
|
.1.3.6.1.4.1.232.18.2.2.1 |
|
|
|
.1.3.6.1.4.1.232.18.2.2.1.1 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.2.1.1.1 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.2.1.1.10 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.2.1.1.11 |
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.12 |
|
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.13 |
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.14 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.2.1.1.15 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.16 |
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.17 |
|
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.18 |
|
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.19 |
|
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.2 |
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.20 |
|
|
|
.1.3.6.1.4.1.232.18.2.2.1.1.21 |
|
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.2.1.1.22 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.23 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.3 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.2.1.1.4 |
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.2.1.1.5 |
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.2.1.1.6 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.7 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.2.1.1.8 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.2.1.1.9 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.2.2 |
.1.3.6.1.4.1.232.18.2.3 |
||
|
|
.1.3.6.1.4.1.232.18.2.3.1 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.3.1.1.1 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.10 |
|
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.11 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.12 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.13 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.14 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.15 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.16 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.17 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.18 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.19 |
|
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.2 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.20 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.21 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.22 |
|
.1.3.6.1.4.1.232.18.2.3.1.1.23 |
||
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.24 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.25 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.26 |
|
.1.3.6.1.4.1.232.18.2.3.1.1.27 |
||
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.28 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.29 |
|
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.3 |
.1.3.6.1.4.1.232.18.2.3.1.1.30 |
||
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.31 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.32 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.33 |
|
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.3.1.1.34 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.35 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.36 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.37 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.38 |
|
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.39 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.4 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.40 |
|
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.41 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.42 |
|
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.3.1.1.43 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.5 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.6 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.3.1.1.7 |
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.8 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.1.1.9 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.2 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.2.1 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.3.2.1.1 |
|
|
.1.3.6.1.4.1.232.18.2.3.2.1.2 |
|
|
|
.1.3.6.1.4.1.232.18.2.3.2.1.3 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.3.3 |
.1.3.6.1.4.1.232.18.2.4 |
||
|
|
.1.3.6.1.4.1.232.18.2.4.1 |
|
|
|
.1.3.6.1.4.1.232.18.2.4.1.1 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.4.1.1.1 |
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.4.1.1.2 |
|
|
.1.3.6.1.4.1.232.18.2.4.1.1.3 |
|
|
|
Integer32
|
.1.3.6.1.4.1.232.18.2.4.1.1.4 |
|
|
OctetString
|
.1.3.6.1.4.1.232.18.2.4.1.1.5 |
|
|
.1.3.6.1.4.1.232.18.2.4.1.1.6 |
|
|
|
.1.3.6.1.4.1.232.18.2.4.1.1.7 |
|
.1.3.6.1.4.1.232.18.2.5 |
||
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.5.1 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.5.2 |
|
|
Enumeration
|
.1.3.6.1.4.1.232.18.2.5.3 |
Dependencies (10) 7 direct · 3 transitive Show tree and compile order Hide dependency details
Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.
Dependency tree
Dependency-first compile order
- RFC-1212rfc
- RFC-1215rfc
- RFC1155-SMIrfc
- SNMPv2-SMIrfc
- SNMPv2-TCrfc
- IANAifType-MIBrfc
- RFC1213-MIBrfc
- CPQHOST-MIBhp
- CPQSINFO-MIBhp
- CPQSTDEQ-MIBhp
- CPQNIC-MIBhpselected
Notifications / Traps (17)
| Name | OID | Description |
|---|---|---|
.1.3.6.1.4.1.232.0.18001 |
This trap will be sent any time connectivity is restored
to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18002 |
This trap will be sent any time the status of a logical
adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. |
|
.1.3.6.1.4.1.232.0.18003 |
This trap will be sent any time a previously failed physical
adapter in a connected logical adapter group returns to the OK condition. This trap is not sent when a logical adapter group has connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18004 |
This trap will be sent any time a physical adapter in a
logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. |
|
.1.3.6.1.4.1.232.0.18005 |
This trap will be sent any time connectivity is restored
to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18006 |
This trap will be sent any time the status of a logical
adapter changes to the Failed condition. This occurs when the adapter in a single adapter configuration fails, or when the last adapter in a redundant configuration fails. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. |
|
.1.3.6.1.4.1.232.0.18007 |
This trap will be sent any time a previously failed physical
adapter in a connected logical adapter group returns to the OK condition. This trap is not sent when a logical adapter group has connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18008 |
This trap will be sent any time a physical adapter in a
logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the cables to the adapter and the Hub or Switch. If no cable problems are found, the adapter, Hub, or Switch may need replacement. |
|
.1.3.6.1.4.1.232.0.18009 |
This trap will be sent when the Virus Throttle Filter
Driver detects virus like activity. User Action: The system reporting this trap requires immediate attention. |
|
.1.3.6.1.4.1.232.0.18010 |
This trap will be sent when the Virus Throttle Filter
Driver no longer detects virus like activity. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18011 |
This trap will be sent any time connectivity is restored
to a logical adapter. This occurs when the physical adapter in a single adapter configuration returns to the OK condition or at least one physical adapter in a logical adapter group returns to the OK condition. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18012 |
This trap will be sent any time the status of a logical adapter changes to disconnected. If this server is powered off, booting, or shutting down, occasional connectivity alerts may occur as the network adapter negotiates with the destination device. These alerts can be ignored and should clear automatically. If this server is booted up and running an operating system, this alert can be caused by loss of connectivity due to a cable being removed, a hub, switch, or interconnect port being disabled or going bad, or an error in configuration of either the OS or the destination device such as interconnect ,blade, switch etc . Check the physical connection from the server to its destination device, including any cables. Also check the configuration of the operating system and destination device. Note that for redundant network connections, this alert will be sent only if connectivity is lost on all individual connections.
|
|
.1.3.6.1.4.1.232.0.18013 |
This trap will be sent any time a previously failed physical
adapter in a connected logical adapter group returns to the OK condition. This trap is not sent when a logical adapter group has connectivity restored from a Failed condition. The cpqNicConnectivityRestored trap is sent instead. This can be caused by replacement of a faulty cable or re-attaching a cable that was unplugged. User Action: None required. |
|
.1.3.6.1.4.1.232.0.18014 |
This trap will be sent any time a physical adapter in a
logical adapter group changes to the Failed condition, but at least one physical adapter remains in the OK condition.. This can be caused by loss of link due to a cable being removed from the adapter or the Hub or Switch. Internal adapter, Hub, or Switch failures can also cause this condition. User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement. |
|
.1.3.6.1.4.1.232.0.18015 |
This trap will be sent any time a physical adapter has had a function up at any point and transitions to having all of its functions down (including function types not in the cpqNic MIB).
User Action: Check the connection to the adapter and validate the connectivity from the server to any external device, including the cabling. If no problems are found, the adapter or other connectivity device may need replacement. |
|
.1.3.6.1.4.1.232.0.18016 |
This trap will be sent any time a physical adapter has had a function up at any point and transitions to having all of its functions down (including function types not in the cpqNic MIB) and then has one if its functions return to up.
User Action: None Required |
|
.1.3.6.1.4.1.232.0.18017 |
This trap is sent when a Flexlom slot failed to train.
User Action: Reinstall the FlexibleLOM card. If the issue persists, update the card firmware. If the issue still persists, contact support |