CPQIODRV-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
6
Rows
6
Columns
108

cpqIoDrvInfoTable

table mandatory
.1.3.6.1.4.1.232.172.2.1.1 · 1 row entry · 53 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqIoDrvInfoTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIODRV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIODRV-MIB::cpqIoDrvInfoTable'
There will be an entry in this table for each IO Drive installed.
cpqIoDrvInfoEntry row .1.3.6.1.4.1.232.172.2.1.1.1
Each entry represents an IO Drive device in system.
Column Syntax OID
Unique number index for each IO Drive entries.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.232.172.2.1.1.1.1
The overall status of the unique IO Drive device.
Enumeration
Enumerated Values:
1other
2ok
3degraded
4failed
.1.3.6.1.4.1.232.172.2.1.1.1.2
System control device name for this IO Drive.
OctetStringr/w
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.3
IO Drive serial number.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.4
IO Drive part number.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.5
Sub-vendor system part number of this device.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.6
The spares part number of this IO Drive.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.7
The assembly number of this IO Drive (HW revision).
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.8
IO Drive firmware version.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.9
Device driver version of this IO Drive.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.10
IO Drive UID written at format time.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.11
The current state of the attached client device.
In order to function normally, the device must be
in the 'attached' state.

Quiescent states:

attached = device is ready for normal use…
Enumerationr/w
Enumerated Values:
0unknown
1detached
2attached
3minimal
4error
5detaching
6attaching
7scanning
8formatting
9updating
10attach
11detach
12format
13update
.1.3.6.1.4.1.232.172.2.1.1.1.12
The name of the attached client device.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.232.172.2.1.1.1.13
Writing a true value here will turn on the LED
flashing beacon for visual card identification. A
false value will turn the LED beacon off.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.14
IO Drive address on the PCI bus.
OctetString
Constraints:
range: 0-15
.1.3.6.1.4.1.232.172.2.1.1.1.15
IO Drive PCI ID.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.232.172.2.1.1.1.16
The PCI subdevice ID of this IO Drive.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.232.172.2.1.1.1.17
The subvendor ID of this IO Drive.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.232.172.2.1.1.1.18
The subvendor ID of this IO Drive.
OctetString
Constraints:
range: 0-25
.1.3.6.1.4.1.232.172.2.1.1.1.19
The PCI slot number of this IO Drive.
Integer32
Constraints:
range: 0-16
.1.3.6.1.4.1.232.172.2.1.1.1.20
A true condition indicates that the device has
surpassed the wearout threshold.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.21
A true condition indicates that flashback redundancy
is degraded.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.22
A value that indicates the writability of the device. This has been expanded to add the
writeReduced value.
Enumeration
Enumerated Values:
0writeReduced
1nonWritable
2normal
3unknown
.1.3.6.1.4.1.232.172.2.1.1.1.23
The current internal temperature of the device in Celsius.
Integer32
Constraints:
range: -100-100
.1.3.6.1.4.1.232.172.2.1.1.1.24
An estimate of the health of the drive expressed
as the remaining percentage of drive life before write rate
is reduced due to wearout. If health percentage is not available
the value will be set to -1.
Integer32
Constraints:
range: -1-100
.1.3.6.1.4.1.232.172.2.1.1.1.25
The date that the drive is estimated to reach the
wearout threshold based on drive usage in the short-term
interval.
RFC1213-MIBDisplayString .1.3.6.1.4.1.232.172.2.1.1.1.26
The date that the drive is estimated to reach the
wearout threshold based on drive usage in the long-term
interval.
RFC1213-MIBDisplayString .1.3.6.1.4.1.232.172.2.1.1.1.27
The date that the drive is estimated to go non-writable
based on drive usage in the short-term interval.
RFC1213-MIBDisplayString .1.3.6.1.4.1.232.172.2.1.1.1.28
The date that the drive is estimated to go non-writable
based on drive usage in the long-term interval.
RFC1213-MIBDisplayString .1.3.6.1.4.1.232.172.2.1.1.1.29
Reason card is in minimal mode.
Enumeration
Enumerated Values:
0unknown
1fwOutOfDate
2lowPower
3dualPlaneFail
5internal
6cardLimitExceeded
7notInMinimalMode
8unsupportedOS
.1.3.6.1.4.1.232.172.2.1.1.1.30
Reason card is in reduced write mode.
Enumeration
Enumerated Values:
0none
1userRequested
2noMdBlocks
3noMemory
4dieFailure
5wearout
6adapterPower
7internal
8powerLimiting
9unavailable
10groomFails
.1.3.6.1.4.1.232.172.2.1.1.1.31
Current voltage level of PCIe 12 volt bus in millivolts.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.32
Peak voltage level of PCIe 12 volt bus in millivolts.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.33
Minimum voltage level of PCIe 12 volt bus in millivolts.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.34
Current wattage drawn on the PCIe 12 volt bus in milliwatts.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.35
Peak wattage drawn on the PCIe 12 volt bus in milliwatts.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.36
Amperage flowing on the PCIe 12 volt bus in milliamps.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.37
Peak amperage flowing on the PCIe 12 volt bus in milliamps.
A value of 0 means value could not be determined.
Integer32
Constraints:
range: 0-65535
.1.3.6.1.4.1.232.172.2.1.1.1.38
Type of ioDimm adapter.
Enumeration
Enumerated Values:
0iodrive
1iodriveLowPro2
2iodriveDuo
3iosan
4unknown
5ioOctal
.1.3.6.1.4.1.232.172.2.1.1.1.39
Port number of this ioDimm on the adapter. If port number
is not available the value will be set to -1.
Integer32
Constraints:
range: -1-65535
.1.3.6.1.4.1.232.172.2.1.1.1.40
Serial number of the adapter where this ioDimm is connected.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.41
A true condition indicates that external power is connected
on the adapter where this ioDimm is connected.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.42
A true condition indicates that powerloss protection is
available but disabled.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.43
A true condition indicates that the internal temperature is
nearing the maximum rating.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.44
The current ambient temperature of the device in Celsius.
Integer32
Constraints:
range: -100-100
.1.3.6.1.4.1.232.172.2.1.1.1.45
The bandwidth compatibility of the PCI-E slot. If the value is not optimal,
the status and condition variables will be set accordingly.
Enumeration
Enumerated Values:
0incompatible
16suboptimal
2048optimal
32768unknown
.1.3.6.1.4.1.232.172.2.1.1.1.46
The power compatibility of the PCI-E slot. If the value is not optimal,
the status and condition variables will be set accordingly.
Enumeration
Enumerated Values:
0incompatible
16suboptimal
2048optimal
32768unknown
.1.3.6.1.4.1.232.172.2.1.1.1.47
The level of governing currently happening on the device. This may be
due to any of several reasons. Current reasons are because of high
temperature, power shortage, or to prolong life of the drive.

Enumeration
Enumerated Values:
0none
1light
2moderate
3heavy
4unavailable
.1.3.6.1.4.1.232.172.2.1.1.1.48
Governing may be impacted for the sake of prolonging longevity of the
device. This value indicates the level of contribution for longevity.

none = no governing active
light = l…
Enumeration
Enumerated Values:
0none
1light
2moderate
3heavy
4unavailable
.1.3.6.1.4.1.232.172.2.1.1.1.49
Governing may be impacted due to a lack of power available to the
device. This value indicates the level of contribution due to
lack of power.

none = no governing active
light …
Enumeration
Enumerated Values:
0none
1light
2moderate
3heavy
4unavailable
.1.3.6.1.4.1.232.172.2.1.1.1.50
Governing may be impacted due to the device reaching high
temperatures. This value indicates the level of contribution due to
high temperatures.

none = no governing active
light …
Enumeration
Enumerated Values:
0none
1light
2moderate
3heavy
4unavailable
.1.3.6.1.4.1.232.172.2.1.1.1.51
A true condition indicates that lifespan governing is enabled.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.1.1.1.52
The target lifespan governing date.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.1.1.1.53

cpqIoDrvExtnTable

table mandatory
.1.3.6.1.4.1.232.172.2.2.1 · 1 row entry · 36 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqIoDrvExtnTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIODRV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIODRV-MIB::cpqIoDrvExtnTable'
This table is extension of IO Drive information.
cpqIoDrvExtnEntry row .1.3.6.1.4.1.232.172.2.2.1.1
Addiotnal Informaiton about IO Drive will be populated in this
table.
Column Syntax OID
Unique number index for each IO Drive extension entries.
There will be one-one mapping between cpqIoDrvExtnIndex
and cpqIoDrvInfoIndex.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.232.172.2.2.1.1.1
The upper word of the max format size in bytes.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.2
The lower word of the max format size in bytes.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.3
The upper word of the usable physical capacity
in bytes. This is space that is holding valid data,
is erased and ready for writing or waiting to be
reclaimed via garbage collection.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.4
The lower word of the usable physical capacity
in bytes. This is space that is holding valid data,
is erased and ready for writing or waiting to be
reclaimed via garbage collection.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.5
The upper word used physical capacity in bytes.
This is the space holding valid, current data.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.6
The lower word used physical capacity in bytes.
This is the space holding valid, current data.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.7
The upper word of the total logical capacity in
bytes as formatted.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.8
The lower word of the total logical capacity in
bytes as formatted.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.9
The upper word of the available logical capacity
in bytes.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.10
The lower word of the available logical capacity
in bytes.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.11
The upper word of the total number of bytes read
since the device was formatted.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.12
The lower word of the total number of bytes read
since the device was formatted.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.13
The upper word of the total bytes written.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.14
The lower word of the total bytes written.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.15
The upper word of the number of user data bytes
written.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.16
The lower word of the number of user data bytes
written.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.17
The start date used to characterize short-term
drive usage.
RFC1213-MIBDisplayStringr/w .1.3.6.1.4.1.232.172.2.2.1.1.18
The number of hours in the short-term usage
characterization window. If this value is non-zero,
then the short-term start date will automatically
track with the short-term end date by the number of
hours specified.
Integer32r/w
Constraints:
range: 0-100000
.1.3.6.1.4.1.232.172.2.2.1.1.19
The end date used to characterize short-term
drive usage.
RFC1213-MIBDisplayStringr/w .1.3.6.1.4.1.232.172.2.2.1.1.20
Set this variable true to automatically have the
short-term end date automatically updated to
the present date.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.2.1.1.21
The start date used to characterize long-term
drive usage.
RFC1213-MIBDisplayStringr/w .1.3.6.1.4.1.232.172.2.2.1.1.22
The number of hours in the long-term usage
characterization window. If this value is non-zero,
then the long-term start date will automatically
track with the long-term end date by the number of
hours specified.
Integer32r/w
Constraints:
range: 0-100000
.1.3.6.1.4.1.232.172.2.2.1.1.23
The end date used to characterize long-term
drive usage.
RFC1213-MIBDisplayStringr/w .1.3.6.1.4.1.232.172.2.2.1.1.24
Set this variable true to automatically have the
long-term end date automatically updated to
the present date.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.2.1.1.25
Set this true to automatically calculate the long-term
and short-term average write rate based on the start and
end dates selected. Otherwise, the average write rate must
be set manually.
Integer32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.232.172.2.2.1.1.26
The upper word of the short-term average write
rate used to characterize drive usage. This will be
automatically calculated based on short-term start and
end dates if the auto calc value is true.
RFC1155-SMICounterr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.27
The lower word of the short-term average write
rate used to characterize drive usage. This will be
automatically calculated based on short-term start and
end dates if the auto calc value is true.
RFC1155-SMICounterr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.28
The upper word of the long-term average write
rate used to characterize drive usage. This will be
automatically calculated based on long-term start and
end dates if the auto calc value is true.
RFC1155-SMICounterr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.29
The lower word of the long-term average write
rate used to characterize drive usage. This will be
automatically calculated based on long-term start and
end dates if the auto calc value is true.
RFC1155-SMICounterr/w
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.30
This defines the confidence interval used to calculate
the wearout and non-writable dates. Expressed as a
percentage, this value reflects the confidence in the
short and long-term averages used to characterize drive
usa…
Integer32r/w
Constraints:
range: 0-100
.1.3.6.1.4.1.232.172.2.2.1.1.31
The block size that this device is formatted to use.
Integer32
Constraints:
range: 512-4096
.1.3.6.1.4.1.232.172.2.2.1.1.32
The upper word of the current RAM usage in bytes for the drive.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.33
The lower word of the current RAM usage in bytes for the drive.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.34
The upper word of the peak RAM usage in bytes for the drive.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.35
The lower word of the peak RAM usage in bytes for the drive.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.2.1.1.36

cpqIoDrvCapacityTable

table mandatory
.1.3.6.1.4.1.232.172.2.3.1 · 1 row entry · 5 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqIoDrvCapacityTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIODRV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIODRV-MIB::cpqIoDrvCapacityTable'
This table will describe the physical capacity of IO Drive.
cpqIoDrvCapacityEntry row .1.3.6.1.4.1.232.172.2.3.1.1
Defines an entry of the usable physical capacity table
Column Syntax OID
The ioDrive index. This correlates to the drive index
in the info table.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.232.172.2.3.1.1.1
Unique index for the usable physical capacity
log.
Integer32
Constraints:
range: 1-1000
.1.3.6.1.4.1.232.172.2.3.1.1.2
The upper word of the physical usable capacity
at this point in time
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.3.1.1.3
The lower word of the physical usable capacity
at this point in time
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.3.1.1.4
The time stamp entry.
RFC1213-MIBDisplayString .1.3.6.1.4.1.232.172.2.3.1.1.5

cpqIoDrvWriteTable

table optional
.1.3.6.1.4.1.232.172.2.4.1 · 1 row entry · 5 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqIoDrvWriteTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIODRV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIODRV-MIB::cpqIoDrvWriteTable'
This table will keep the history of writes on the IO Drive
cpqIoDrvWriteEntry row .1.3.6.1.4.1.232.172.2.4.1.1
A log of write volume history.
Column Syntax OID
The ioDrive index. This correlates with the index
in the info table.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.232.172.2.4.1.1.1
Unique index for this write volume entry.
Integer32
Constraints:
range: 1-1000
.1.3.6.1.4.1.232.172.2.4.1.1.2
The upper word of the total physical number of
bytes written at a given moment in time.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.4.1.1.3
The lower word of the total physical number of
bytes written at a given moment in time.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.4.1.1.4
The time stamp entryfor this value.
RFC1213-MIBDisplayString .1.3.6.1.4.1.232.172.2.4.1.1.5

cpqIoDrvTempTable

table optional
.1.3.6.1.4.1.232.172.2.5.1 · 1 row entry · 4 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqIoDrvTempTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIODRV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIODRV-MIB::cpqIoDrvTempTable'
IO Drive temperature history table.
cpqIoDrvTempEntry row .1.3.6.1.4.1.232.172.2.5.1.1
Log of IO Drive temperature.
Column Syntax OID
The device index. This correlates to the index in
the info table.
Integer32
Constraints:
range: 1-256
.1.3.6.1.4.1.232.172.2.5.1.1.1
Unique index for this temperature log entry.
Integer32
Constraints:
range: 0-255
.1.3.6.1.4.1.232.172.2.5.1.1.2
The current temperature of the device in Celsius.
Integer32
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.5.1.1.3
The timestamp for this entry.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.5.1.1.4

cpqIoDrvProcTable

table obsolete
.1.3.6.1.4.1.232.172.2.6.1 · 1 row entry · 5 columns
Uses the hp variant from /opt/observium/mibs/hp.
Command help
Walk cpqIoDrvProcTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQIODRV-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQIODRV-MIB::cpqIoDrvProcTable'
A table of processes that support IO Drive operation.
cpqIoDrvProcEntry row .1.3.6.1.4.1.232.172.2.6.1.1
Each entry represents a process in the table.
Column Syntax OID
A unique index for each process.
Integer32
Constraints:
range: 0-500
.1.3.6.1.4.1.232.172.2.6.1.1.1
The process name.
OctetString
Constraints:
range: 0-50
.1.3.6.1.4.1.232.172.2.6.1.1.2
The process state.
OctetString
Constraints:
range: 0-100
.1.3.6.1.4.1.232.172.2.6.1.1.3
The bytes of RAM currently in use by the process.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.232.172.2.6.1.1.4
The overall percentage of CPU usage.
Integer32
Constraints:
range: 0-100
.1.3.6.1.4.1.232.172.2.6.1.1.5