ble memory error occurred.
The error has been corrected. The current number of correctable
memory errors is reported in the variable cpqHeCorrMemTotalErrs.
cpqHe2CorrectableMemoryLogDisabled
.1.3.6.1.4.1.232.0.6002
e memory error tracking disabled.
The frequency of errors is so high that the error tracking
logic has been temporarily disabled. The cpqHeCorrMemLogStatus
variable indicated the current tracking status.
cpqHeThermalTempFailed
.1.3.6.1.4.1.232.0.6003
ature status has been set to failed.
The system will be shutdown due to this thermal condition.
cpqHeThermalTempDegraded
.1.3.6.1.4.1.232.0.6004
ature status has been set to degraded.
The server's temperature is outside of the normal operating
range. The server will be shutdown if the
cpqHeThermalDegradedAction variable is set to shutdown(3).
cpqHeThermalTempOk
.1.3.6.1.4.1.232.0.6005
ature status has been set to ok.
The server's temperature has returned to the normal operating
range.
cpqHeThermalSystemFanFailed
.1.3.6.1.4.1.232.0.6006
fan status has been set to failed.
A required system fan is not operating normally. The system
will be shutdown if the cpqHeThermalDegradedAction variable
is set to shutdown(3).
cpqHeThermalSystemFanDegraded
.1.3.6.1.4.1.232.0.6007
fan status has been set to degraded.
An optional system fan is not operating normally.
cpqHeThermalSystemFanOk
.1.3.6.1.4.1.232.0.6008
fan status has been set to ok.
Any previously non-operational system fans have returned to
normal operation.
cpqHeThermalCpuFanFailed
.1.3.6.1.4.1.232.0.6009
n status has been set to failed.
A processor fan is not operating normally. The server will be
shutdown.
cpqHeThermalCpuFanOk
.1.3.6.1.4.1.232.0.6010
n status has been set to ok.
Any previously non-operational processor fans have returned
to normal operation.
cpqHeAsrConfirmation
.1.3.6.1.4.1.232.0.6011
is operational again.
The server has previously been shutdown by the
Automatic Server Recovery (ASR) feature and has just
become operational again.
cpqHeThermalConfirmation
.1.3.6.1.4.1.232.0.6012
is operational again.
The server has previously been shutdown due to a thermal
anomaly on the server and has just become operational again.
cpqHePostError
.1.3.6.1.4.1.232.0.6013
e POST errors occurred.
Power On Self-Test (POST) errors occur during the server
restart process.
cpqHeFltTolPwrSupplyDegraded
.1.3.6.1.4.1.232.0.6014
tolerant power supply sub-system condition has been
set to degraded.
cpqHe3CorrectableMemoryError
.1.3.6.1.4.1.232.0.6015
ble memory error occurred.
The error has been corrected. The current number of correctable
memory errors is reported in the variable cpqHeCorrMemTotalErrs.
cpqHe3CorrectableMemoryLogDisabled
.1.3.6.1.4.1.232.0.6016
e memory error tracking disabled.
The frequency of errors is so high that the error tracking
logic has been temporarily disabled. The cpqHeCorrMemLogStatus
variable indicated the current tracking status.
cpqHe3ThermalTempFailed
.1.3.6.1.4.1.232.0.6017
ature status has been set to failed.
The system will be shutdown due to this thermal condition.
cpqHe3ThermalTempDegraded
.1.3.6.1.4.1.232.0.6018
ature status has been set to degraded.
The server's temperature is outside of the normal operating
range. The server will be shutdown if the
cpqHeThermalDegradedAction variable is set to shutdown(3).
cpqHe3ThermalTempOk
.1.3.6.1.4.1.232.0.6019
ature status has been set to ok.
The server's temperature has returned to the normal operating
range.
cpqHe3ThermalSystemFanFailed
.1.3.6.1.4.1.232.0.6020
fan status has been set to failed.
A required system fan is not operating normally. The system
will be shutdown if the cpqHeThermalDegradedAction variable
is set to shutdown(3).
cpqHe3ThermalSystemFanDegraded
.1.3.6.1.4.1.232.0.6021
fan status has been set to degraded.
An optional system fan is not operating normally.
cpqHe3ThermalSystemFanOk
.1.3.6.1.4.1.232.0.6022
fan status has been set to ok.
Any previously non-operational system fans have returned to
normal operation.
cpqHe3ThermalCpuFanFailed
.1.3.6.1.4.1.232.0.6023
n status has been set to failed.
A processor fan is not operating normally. The server will be
shutdown.
cpqHe3ThermalCpuFanOk
.1.3.6.1.4.1.232.0.6024
n status has been set to ok.
Any previously non-operational processor fans have returned
to normal operation.
cpqHe3AsrConfirmation
.1.3.6.1.4.1.232.0.6025
is operational again.
The server has previously been shutdown by the
Automatic Server Recovery (ASR) feature and has just
become operational again.
cpqHe3ThermalConfirmation
.1.3.6.1.4.1.232.0.6026
is operational again.
The server has previously been shutdown due to a thermal
anomaly on the server and has just become operational again.
cpqHe3PostError
.1.3.6.1.4.1.232.0.6027
e POST/UEFI errors occurred.
Power On Self-Test (POST) errors occur during the server
restart process. UEFI errors occur during server boot time and run time.
Details of the POST/UEFI error messages can be found in Integrated Management Log.
cpqHe3FltTolPwrSupplyDegraded
.1.3.6.1.4.1.232.0.6028
tolerant power supply sub-system condition has been
set to degraded.
cpqHe3CorrMemReplaceMemModule
.1.3.6.1.4.1.232.0.6029
ble memory log entry indicates a memory module needs
to be replaced.
The errors have been corrected, but the memory module should be
replaced. The error information is reported in the variable
cpqHeCorrMemErrDesc.
cpqHe3FltTolPowerSupplyDegraded
.1.3.6.1.4.1.232.0.6030
tolerant power supply condition has been set
to degraded for the specified chassis and bay location.
cpqHe3FltTolPowerSupplyFailed
.1.3.6.1.4.1.232.0.6031
tolerant power supply condition has been set
to failed for the specified chassis and bay location.
cpqHe3FltTolPowerRedundancyLost
.1.3.6.1.4.1.232.0.6032
Tolerant Power Supplies have lost redundancy for
the specified chassis.
cpqHe3FltTolPowerSupplyInserted
.1.3.6.1.4.1.232.0.6033
lerant Power Supply has been inserted into the
specified chassis and bay location.
cpqHe3FltTolPowerSupplyRemoved
.1.3.6.1.4.1.232.0.6034
lerant Power Supply has been removed from the
specified chassis and bay location.
cpqHe3FltTolFanDegraded
.1.3.6.1.4.1.232.0.6035
Tolerant Fan condition has been set to degraded
for the specified chassis and fan.
cpqHe3FltTolFanFailed
.1.3.6.1.4.1.232.0.6036
Tolerant Fan condition has been set to failed
for the specified chassis and fan.
cpqHe3FltTolFanRedundancyLost
.1.3.6.1.4.1.232.0.6037
Tolerant Fans have lost redundancy for the
specified chassis.
cpqHe3FltTolFanInserted
.1.3.6.1.4.1.232.0.6038
lerant Fan has been inserted into the specified
chassis and fan location.
cpqHe3FltTolFanRemoved
.1.3.6.1.4.1.232.0.6039
lerant Fan has been removed from the specified
chassis and fan location.
cpqHe3TemperatureFailed
.1.3.6.1.4.1.232.0.6040
ature status has been set to failed in the
specified chassis and location.
The system will be shutdown due to this condition.
cpqHe3TemperatureDegraded
.1.3.6.1.4.1.232.0.6041
ature status has been set to degraded in the
specified chassis and location.
The server's temperature is outside of the normal operating
range. The server will be shutdown if the
cpqHeThermalDegradedAction variable is set to shutdown(3).
cpqHe3TemperatureOk
.1.3.6.1.4.1.232.0.6042
ature status has been set to ok in the
specified chassis and location.
The server's temperature has returned to the normal operating
range.
cpqHe3PowerConverterDegraded
.1.3.6.1.4.1.232.0.6043
Power Converter condition has been set to degraded
for the specified chassis, slot and socket.
cpqHe3PowerConverterFailed
.1.3.6.1.4.1.232.0.6044
Power Converter condition has been set to failed
for the specified chassis, slot and socket.
cpqHe3PowerConverterRedundancyLost
.1.3.6.1.4.1.232.0.6045
Power Converters have lost redundancy for the
specified chassis.
cpqHe3CacheAccelParityError
.1.3.6.1.4.1.232.0.6046
celerator parity error indicates a cache module
needs to be replaced.
The error information is reported in the variable
cpqHeEventLogErrorDesc.
cpqHeResilientMemOnlineSpareEngaged
.1.3.6.1.4.1.232.0.6047
emory Protection Online Spare Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. The Online Spare Memory has been activated.
User Action: Schedule server down-time to replace the faulty
memory.
cpqHe4FltTolPowerSupplyOk
.1.3.6.1.4.1.232.0.6048
tolerant power supply condition has been set back
to the OK state for the specified chassis and bay location.
cpqHe4FltTolPowerSupplyDegraded
.1.3.6.1.4.1.232.0.6049
tolerant power supply condition has been set
to degraded for the specified chassis and bay location.
cpqHe4FltTolPowerSupplyFailed
.1.3.6.1.4.1.232.0.6050
tolerant power supply condition has been set
to failed for the specified chassis and bay location.
cpqHeResilientMemMirroredMemoryEngaged
.1.3.6.1.4.1.232.0.6051
emory Protection Mirrored Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. Mirrored Memory has been activated.
User Action: Replace the faulty memory.
cpqHeResilientAdvancedECCMemoryEngaged
.1.3.6.1.4.1.232.0.6052
emory Protection Advanced ECC Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. Advanced ECC has been activated.
User Action: Replace the faulty memory.
cpqHeResilientMemXorMemoryEngaged
.1.3.6.1.4.1.232.0.6053
emory Protection XOR Engine Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. The XOR engine has been activated.
User Action: Replace the faulty memory.
cpqHe3FltTolPowerRedundancyRestored
.1.3.6.1.4.1.232.0.6054
Tolerant Power Supplies have returned to a redundant
state for the specified chassis.
cpqHe3FltTolFanRedundancyRestored
.1.3.6.1.4.1.232.0.6055
Tolerant Fans have returned to a redundant state for
the specified chassis.
cpqHe4CorrMemReplaceMemModule
.1.3.6.1.4.1.232.0.6056
Memory Errors Detected
The errors have been corrected, but the memory module should be
replaced.
cpqHeResMemBoardRemoved
.1.3.6.1.4.1.232.0.6057
rd or cartridge removed.
An Advanced Memory Protection sub-system board or cartridge has
been removed from the system.
User Action: Ensure the board or cartridge has memory correctly
installed and re-insert the memory board or cartridge back into
the system.
cpqHeResMemBoardInserted
.1.3.6.1.4.1.232.0.6058
rd or cartridge inserted.
An Advanced Memory Protection sub-system board or cartridge has
been inserted into the system.
User Action: None.
cpqHeResMemBoardBusError
.1.3.6.1.4.1.232.0.6059
rd or cartridge bus error detected.
An Advanced Memory Protection sub-system board or cartridge
bus error has been detected.
User Action: Replace the indicated board or cartridge.
cpqHeEventOccurred
.1.3.6.1.4.1.232.0.6060
as occurred.
User Action: None.
cpqHeManagementProcInReset
.1.3.6.1.4.1.232.0.6061
ment processor is currently in reset
The management processor is currently in the process of being reset
because of a firmware update or some other event.
User action: None
cpqHeManagementProcReady
.1.3.6.1.4.1.232.0.6062
ment processor is ready
The management processor has successfully reset and is now available
again.
User action: None
cpqHeManagementProcFailedReset
.1.3.6.1.4.1.232.0.6063
ment processor failed reset
The management processor was not successfully reset and is not
operational.
User action: Reset the management procesessor again or re-flash
the management processor firmware.
cpqHe5CorrMemReplaceMemModule
.1.3.6.1.4.1.232.0.6064
\ uncorrected Memory Errors Detected
The errors have been corrected, but the memory module should be
replaced. Value 0 for CPU means memory is not Processor based
cpqHe5ResMemBoardRemoved
.1.3.6.1.4.1.232.0.6065
rd or cartridge or riser removed.
An Advanced Memory Protection sub-system board or cartridge or riser has
been removed from the system. Value 0 for CPU means memory is not processor based.
User Action: Ensure the board or cartridge or riser has memory correctly
installed and re-insert the memory board or cartridge or CPU back into
the system.
cpqHe5ResMemBoardInserted
.1.3.6.1.4.1.232.0.6066
rd or cartridge or riser inserted.
An Advanced Memory Protection sub-system board or cartridge or riser
Has been inserted into the system. Value 0 for CPU means memory is not processor based.
User Action: None.
cpqHe5ResMemBoardBusError
.1.3.6.1.4.1.232.0.6067
rd or cartridge or Riser bus error detected.
An Advanced Memory Protection sub-system board or cartridge or Riser
bus error has been detected. Value 0 for CPU means memory is not processor based.
User Action: Replace the indicated board or cartridge or Riser.
cpqHeResilientMemLockStepMemoryEngaged
.1.3.6.1.4.1.232.0.6068
emory Protection LockStep Engine Memory Engaged.
The Advanced Memory Protection subsystem has detected a memory
fault. The LockStep engine has been activated.
User Action: Replace the faulty memory.
cpqHe4FltTolPowerSupplyACpowerloss
.1.3.6.1.4.1.232.0.6069
The fault tolerant power supply AC power loss for the specified chassis and bay location.
cpqHeSysBatteryFailed
.1.3.6.1.4.1.232.0.6070
battery has either failed or met a predictive failure condition
for the specified chassis and index location.
cpqHeSysBatteryRemoved
.1.3.6.1.4.1.232.0.6071
battery condition has removed
for the specified chassis and index location.
cpqHeSysPwrAllocationNotOptimized
.1.3.6.1.4.1.232.0.6072
Error in setting server power throttle. Server enclosure power request has increased. Server power allocation is not optimized.
cpqHeSysPwrOnDenied
.1.3.6.1.4.1.232.0.6073
One of the Field Replacement Units(FRU) is not allowing the system to power on.
cpqHePowerFailureError
.1.3.6.1.4.1.232.0.6074
This trap signifies a device connected to or embedded on the system board has an error.
cpqHeInterlockFailureError
.1.3.6.1.4.1.232.0.6075
This trap signifies a device missing or improperly seated on the system board.
cpqHeNvdimmBackupError
.1.3.6.1.4.1.232.0.6076
NVDIMM Error - Backup Error detected. Persistent data backup failed and data is not available.
cpqHeNvdimmRestoreError
.1.3.6.1.4.1.232.0.6077
NVDIMM Error - Restore Error detected. Persistent data restore failed and data is not available.
cpqHeNvdimmUncorrectableMemoryError
.1.3.6.1.4.1.232.0.6078
NVDIMM Error -Uncorrectable Memory Error - This NVDIMM will not be available to the operating system.
cpqHeNvdimmBackupPowerError
.1.3.6.1.4.1.232.0.6079
NVDIMM Error - Backup Power Error. Backup power is not available and a future backup is not possible.
cpqHeNvdimmNVDIMMControllerError
.1.3.6.1.4.1.232.0.6080
NVDIMM Error - NVDIMM Controller Error. An error was found with the NVDIMM controller. The OS will not use the NVDIMM.
cpqHeNvdimmEraseError
.1.3.6.1.4.1.232.0.6081
NVDIMM Error - Erase Error. NVDIMM could not be erased and future backups are not possible.
cpqHeNvdimmArmingError
.1.3.6.1.4.1.232.0.6082
NVDIMM Error - Arming Error. NVDIMM could not be armed and future backups are not possible.
cpqHeNvdimmSanitizationOk
.1.3.6.1.4.1.232.0.6083
This NVDIMM-N was selected for Sanitizing/Erasing. All data saved in the NVDIMM has been erased.
cpqHeNvdimmSanitizationError
.1.3.6.1.4.1.232.0.6084
NVDIMM Error - Sanitization Error. This NVDIMM-N was selected for Sanitizing/Erasing, but this process was not successful.
cpqHeNvdimmControllerFirmwareError
.1.3.6.1.4.1.232.0.6085
NVDIMM Error - Controller Firmware Error. The controller firmware has been corrupted. The OS will not use the NVDIMM.
cpqHeNvdimmErrorInterleaveOn
.1.3.6.1.4.1.232.0.6086
NVDIMM Error. NVDIMM received a memory initialization or uncorrectable error. All NVDIMMs on Processor are disabled.
cpqHeNvdimmInterleaveOff
.1.3.6.1.4.1.232.0.6087
NVDIMM Error - NVDIMM received a memory initialization or uncorrectable error. NVDIMM has been disabled.
cpqHeNvdimmEventNotifyError
.1.3.6.1.4.1.232.0.6088
NVDIMM Error - Unable to set event notification for this NVDIMM.
cpqHeNvdimmPersistencyLost
.1.3.6.1.4.1.232.0.6089
NVDIMM Error - Persistency Lost. NVDIMM Persistency is lost and future data backup is not available.
cpqHeNvdimmPersistencyRestored
.1.3.6.1.4.1.232.0.6090
NVDIMM - Persistency Restored. NVDIMM Persistency is restored and future data backup is available.
cpqHeNvdimmLifecycleWarning
.1.3.6.1.4.1.232.0.6091
NVDIMM Lifecycle Warning. NVDIMM lifetime has reached.
cpqHeNvdimmLogicalNvdimmError
.1.3.6.1.4.1.232.0.6092
e Logical NVDIMM errors occurred.
Details of the Logical NVDIMM error messages can
be found in Integrated Management Log
cpqHeNvdimmConfigurationError
.1.3.6.1.4.1.232.0.6093
e NVDIMM Configuration errors occurred.
Details of the NVDIMM Configuration error messages can
be found in Integrated Management Log
cpqHeNvdimmBatteryNotChargedwithWait
.1.3.6.1.4.1.232.0.6094
Smart battery is not charged sufficiently to support the NVDIMMs installed in the system.
cpqHeNvdimmBatteryNotChargedwithNoWait
.1.3.6.1.4.1.232.0.6095
Smart battery is not charged sufficiently to support the NVDIMMs installed in the system.
cpqHeDimmMemoryMapChanged
.1.3.6.1.4.1.232.0.6096
Uncorrectable Memory Error - The failed memory module could not be determined.
cpqHeNvdimmPersistantMemoryAddressError
.1.3.6.1.4.1.232.0.6097
Persistent Memory Address Range Scrub has detected an error.
cpqHeNvdimmInitializationError
.1.3.6.1.4.1.232.0.6098
NVDIMM(s) cannot be initialized due to internal error.
cpqHePwrSupplyError
.1.3.6.1.4.1.232.0.6099
System Power Supply Error.
cpqHePwrSupplyErrorRepaired
.1.3.6.1.4.1.232.0.6100
System Power Supply Error Repaired.
cpqHeBbuError
.1.3.6.1.4.1.232.0.6101
Battery Backup Unit Error.
cpqHeBbuErrorRepaired
.1.3.6.1.4.1.232.0.6102
Battery Backup Unit Error Repaired.
cpqHeNoPowerSupplyDetected
.1.3.6.1.4.1.232.0.6103
Power Supply or Power Backplane Detection Error.
cpqHePowerProtectionFault
.1.3.6.1.4.1.232.0.6104
System Board Power Protection Fault.
cpqHePowerFuseDegraded
.1.3.6.1.4.1.232.0.6105
A degraded power event has been detected and the server system board should be replaced.
cpqHeTPMSecureEraseFailed
.1.3.6.1.4.1.232.0.6106
Trusted Platform Module has failed the Secure Erase Operation.
cpqHeSPISecureEraseFailed
.1.3.6.1.4.1.232.0.6107
One-button secure erase of system firmware configuration data has failed
cpqHePMMSecureEraseFailed
.1.3.6.1.4.1.232.0.6108
Secure Erase of HPE Persistent Memory has failed.
cpqHeNANDSecureEraseFailed
.1.3.6.1.4.1.232.0.6109
Secure Erase of the management processor's embedded media device has Failed.
cpqHeSedPassphrasefail
.1.3.6.1.4.1.232.0.6110
Device Encryption Error. Enabling or Disabling encryption/modifying passphrase failed.
cpqHeSedUnlockfail
.1.3.6.1.4.1.232.0.6111
Device Encryption Error - Three incorrect attempts were made to unlock Processor and DIMM. The device will be locked until the next power cycle.
cpqHePMMHealthFailure
.1.3.6.1.4.1.232.0.6112
The HPE Persistent Memory Module has experienced an issue and is not longer operational or resilient.
cpqHePMMLessUsageRemainingAlert
.1.3.6.1.4.1.232.0.6113
HPE Persistent Memory Percentage Remaining Alert. The HPE Persistent Memory Module has less usage remaining. Future errors on this HPE Persistent Memory Module may result in loss of data
cpqHePMMConfigErr
.1.3.6.1.4.1.232.0.6114
e PMM Configuration errors occurred.
Details of the PMM Configuration error messages can
be found in Integrated Management Log
cpqHePMMShutdownWarning
.1.3.6.1.4.1.232.0.6115
HPE Persistent Memory Health Warning. The HPE Persistent Memory Module reported an unsafe shutdown.
cpqHePMMCorrErrThreshold
.1.3.6.1.4.1.232.0.6116
Correctable Memory Error Threshold Exceeded
cpqHePMMBootStatusRegWarning
.1.3.6.1.4.1.232.0.6117
HPE Persistent Memory Error - The HPE Memory Module reported a failure on the previous boot
cpqHeInletAmbientPreCautionThresAlert
.1.3.6.1.4.1.232.0.6118
ent temperature sensor user defined Pre-Caution threshold level exceeded.
Air baffle or blank is missing or not installed properly and causing
a disruption of the airflow. Data Center cooling might be disrupted.
cpqHeCoolingModuleDegraded
.1.3.6.1.4.1.232.0.6119
The Cooling Module condition has been set to degraded for the specified chassis .
cpqHeCoolingModuleFailed
.1.3.6.1.4.1.232.0.6120
The Cooling Module condition has been set to failed for the specified chassis.
cpqHeCoolingModuleRedundancyLost
.1.3.6.1.4.1.232.0.6121
The Cooling Modules have lost redundancy for the specified chassis.
cpqHeCoolingModuleRedundancyRestored
.1.3.6.1.4.1.232.0.6122
The Cooling Modules have returned to a redundant state for the specified chassis.
cpqHeCorrectableMemoryError
.1.3.6.1.4.1.232.6.0.1
ble memory error occurred.
The error has been corrected. The current number of correctable
memory errors is reported in the variable cpqHeCorrMemTotalErrs.
cpqHeCorrectableMemoryLogDisabled
.1.3.6.1.4.1.232.6.0.2
e memory error tracking disabled.
The frequency of errors is so high that the error tracking
logic has been temporarily disabled. The cpqHeCorrMemLogStatus
variable indicated the current tracking status.