CPI-UNIFIED-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
26
Rows
26
Columns
219

cpiPduTable

table
.1.3.6.1.4.1.30932.1.10.1.2.10 · 1 row entry · 18 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduTable'
This table contains a list of PDU entries that are being monitored
by the PDU. 
          
The table contains one, or many rows, depending upon the 
number of PDUs being monitored. Each row in the table represents a PDU 
in the daisy chain.
          
This table always contains at least one entry and a maximum of 32 entries.
The MAC address is used as an index on the table to allow data collectors
to ensure that information can be retrieved for a specific PDU.
cpiPduEntry row .1.3.6.1.4.1.30932.1.10.1.2.10.1
This entry defines the columns to be populated in the
'cpiPduTable'. Each column represents an attribute of a PDU.
This table is indexed by the PDU MAC that is globally unique.
Indexes
Column Syntax OID
cpiPduMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.1
cpiPduModelGet the model number of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.2
cpiPduNameSet or get the user assigned name of the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.3
cpiPduDescriptionSet or get the user assigned description of the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.4
cpiPduHasBranchMonitorAn indicator if the PDU supports monitoring voltage, and current on branches in the PDU.Enumeration
Enumerated Values:
0notsupported
1supported
.1.3.6.1.4.1.30932.1.10.1.2.10.1.5
cpiPduHasOutletMonitorAn indicator if the PDU supports monitoring current on the individual outlets in the PDU.Enumeration
Enumerated Values:
0notsupported
1supported
.1.3.6.1.4.1.30932.1.10.1.2.10.1.6
cpiPduHasOutletControlAn indicator if the PDU supports control (turn on/off) individual outlets in the PDU.Enumeration
Enumerated Values:
0notsupported
1supported
.1.3.6.1.4.1.30932.1.10.1.2.10.1.7
cpiPduNumberBranchesGet the number of branches (breakers) in the PDU.Integer32
Constraints:
range: 0-12
.1.3.6.1.4.1.30932.1.10.1.2.10.1.8
cpiPduNumberOutletsGet the number of outlets in the PDU.Integer32
Constraints:
range: 0-72
.1.3.6.1.4.1.30932.1.10.1.2.10.1.9
cpiPduOutOfServiceSet or get whether the PDU is in-service.Enumerationr/w
Enumerated Values:
0inservice
1outofservice
.1.3.6.1.4.1.30932.1.10.1.2.10.1.10
cpiPduVersionGet the firmware version number of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.11
cpiPduUpgradeAn indicator if the PDU firmware is being upgraded.Enumeration
Enumerated Values:
0no
1yes
.1.3.6.1.4.1.30932.1.10.1.2.10.1.12
cpiPduChainRoleGet the role of the PDU in a daisy chain.Enumerationr/w
Enumerated Values:
0secondary
1primary
2alternate
.1.3.6.1.4.1.30932.1.10.1.2.10.1.13
cpiPduIpGet IP address of the PDU.SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.10.1.2.10.1.14
cpiPduIpv6Get the IPv6 address of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.15
cpiPduTotalPowerGet the power in volt-amps for the entire PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.2.10.1.16
cpiPduCabinetIdGet/set the name of the cabinet the PDU is in.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.17
cpiPduSerialNumGet the serial number of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.2.10.1.18
.1.3.6.1.4.1.30932.1.10.1.3.10 · 1 row entry · 3 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduLineTable'
This table contains a list of PDU line entries that are being
monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of input lines. Each row 
in the table represents a PDU line in the daisy chain.
          
The table is indexed based on the corresponding Line Input ID and
the source PDU MAC.
cpiPduLineEntry row .1.3.6.1.4.1.30932.1.10.1.3.10.1
This entry defines the columns to be populated in the
'cpiPduLineTable'. Each column represents an attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
cpiPduLineMacGet the MAC address of the PDU that owns the input line.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.3.10.1.1
cpiPduLineIdGet the ID of the input line on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.10.1.2
cpiPduLineCurrentGet current draw in 1/100 amp of the line on the PDU. Convert the value by dividing by 100.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.10.1.3
.1.3.6.1.4.1.30932.1.10.1.3.110 · 1 row entry · 9 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduBranchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduBranchTable'
This table contains a list of PDU branch entries that are being
monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of branches per PDU. Each row 
in the table represents a PDU branch in the daisy chain.
          
The table is indexed based on the corresponding Branch ID and
the source PDU MAC.
cpiPduBranchEntry row .1.3.6.1.4.1.30932.1.10.1.3.110.1
This entry defines the columns to be populated in the
'cpiPduBranchTable'. Each column represents an attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
cpiPduBranchMacGet the MAC address of the PDU that owns the branch.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.3.110.1.1
cpiPduBranchIdGet the ID of the branch on the owning PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.110.1.2
cpiPduBranchCurrentGet the current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.110.1.3
cpiPduBranchMaxCurrentGet the maximum current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.110.1.4
cpiPduBranchVoltageGet the voltage in 1/10 volts of the branch on the PDU. Convert the value by dividing by 10.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.110.1.5
cpiPduBranchPowerGet the power in volt-amps for the branch.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.110.1.6
cpiPduBranchPowerFactorGet the power factor for the branch.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.110.1.7
cpiPduBranchStatusGet the alarm status of the branch.Enumeration
Enumerated Values:
0noalarm
1warning
2alarm
.1.3.6.1.4.1.30932.1.10.1.3.110.1.8
cpiPduBranchEnergyGet the branch energy accumulated in decaVA-secs, divide by 360 to obtain VA-hr.SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.30932.1.10.1.3.110.1.9
.1.3.6.1.4.1.30932.1.10.1.3.210 · 1 row entry · 12 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduBranchAlertTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduBranchAlertTable'
This table contains a list of PDU branch alert entries that are
being monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of branches per PDU. Each row 
in the table represents a PDU branch in the daisy chain.
          
The table is indexed based on the corresponding Branch ID and the
source PDU MAC.
cpiPduBranchAlertEntry row .1.3.6.1.4.1.30932.1.10.1.3.210.1
This entry defines the columns to be populated in the
'cpiPduBranchAlertTable'. Each column represents an alert attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
cpiPduBranchAlertMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.3.210.1.1
cpiPduBranchAlertBranchIdGet the branch ID on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.2
cpiPduBranchAlertWarnLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.3
cpiPduBranchAlertWarnHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.4
cpiPduBranchAlertLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.5
cpiPduBranchAlertHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU, that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.6
cpiPduBranchAlertCriticalCurrentSet or get the critical current draw in 1/100 amp of the
branch on the PDU. Convert the value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.7
cpiPduBranchAlertWarnLoVoltSet or get the minimum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.8
cpiPduBranchAlertWarnHiVoltSet or get the maximum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.9
cpiPduBranchAlertLoVoltSet or get the minimum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.10
cpiPduBranchAlertHiVoltSet or get the maximum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.3.210.1.11
cpiPduBranchAlertIndexIndex for branch alert.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.30932.1.10.1.3.210.1.12
.1.3.6.1.4.1.30932.1.10.1.4.10 · 1 row entry · 12 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduOutletTable'
This table contains a list of PDU outlet entries that are being
monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of outlets on each PDU. 
Each row in the table represents a PDU outlet in the daisy chain.
          
The table is indexed based on the corresponding Outlet ID and
the source PDU MAC.
cpiPduOutletEntry row .1.3.6.1.4.1.30932.1.10.1.4.10.1
This entry defines the columns to be populated in the
'cpiPduOutletTable'. Each column represents an outlet of a PDU.
This table is indexed by the PDU Outlet identifier that is unique
within the PDU.
Column Syntax OID
cpiPduOutletMacGet the MAC address of the source PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.4.10.1.1
cpiPduOutletIdGet the ID of the outlet on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.10.1.2
cpiPduOutletBranchIdGet the ID of the branch the outlet is associated with on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.10.1.3
cpiPduOutletNameSet or get the user supplied name of the outlet on the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.4.10.1.4
cpiPduOutletDescriptionSet or get the user supplied description of the outlet on the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.4.10.1.5
cpiPduOutletCurrentGet the current draw in 1/100 amp of the outlet on the PDU. Convert
the value by dividing by 100.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.10.1.6
cpiPduOutletVoltageGet the voltage in 1/10 volts of the outlet on the PDU. Convert the
value by dividing by 10.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.10.1.7
cpiPduOutletPowerThe power in Volt-Amps of the outlet on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.10.1.8
cpiPduOutletStatusGet the alarm status of the outlet.Enumeration
Enumerated Values:
0noalarm
1warning
2alarm
.1.3.6.1.4.1.30932.1.10.1.4.10.1.9
cpiPduOutletEnergyGet the outlet energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.30932.1.10.1.4.10.1.10
cpiPduOutletControlSet or get power control to the outlet.Enumerationr/w
Enumerated Values:
0off
1on
.1.3.6.1.4.1.30932.1.10.1.4.10.1.11
cpiPduOutletResetSet or get reset power to the outlet.Enumerationr/w
Enumerated Values:
0nominal
1reset
.1.3.6.1.4.1.30932.1.10.1.4.10.1.12
.1.3.6.1.4.1.30932.1.10.1.4.210 · 1 row entry · 4 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduOutletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduOutletConfigTable'
This table contains a list of PDU outlet configuration entries
that are being monitored by the PDU.
          
 The table contains one, or many rows, depending upon the number
 of PDUs being monitored and the number of outlets per PDU. Each row 
 in the table represents a PDU outlet in the daisy chain.
           
 The table is indexed based on the corresponding Outlet ID and
 the source PDU MAC.
cpiPduOutletConfigEntry row .1.3.6.1.4.1.30932.1.10.1.4.210.1
This entry defines the columns to be populated in the
'cpiPduOutletConfigTable'. Each column represents an
configurable attribute of an outlet in the PDU. This
table is indexed by the PDU Line identifier that is
uni…
Column Syntax OID
cpiPduOutletConfigMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.4.210.1.1
cpiPduOutletConfigOutletIdGet the ID of the outlet on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.210.1.2
cpiPduOutletConfigOnDelaySet or get the outlet power-on delay in seconds.Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.30932.1.10.1.4.210.1.3
cpiPduOutletConfigResetDelaySet or get the outlet reset delay in seconds.Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.30932.1.10.1.4.210.1.4
.1.3.6.1.4.1.30932.1.10.1.4.310 · 1 row entry · 7 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduOutletAlertTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduOutletAlertTable'
This table contains a list of PDU outlet alert entries that are
being monitored by the PDU.
          
 The table contains one, or many rows, depending upon the number
 of PDUs being monitored and the number of outlets per PDU. Each row 
 in the table represents a PDU outlet in the daisy chain.
           
 The table is indexed based on the corresponding Outlet ID and the
 source PDU MAC.
cpiPduOutletAlertEntry row .1.3.6.1.4.1.30932.1.10.1.4.310.1
This entry defines the columns to be populated in the
'cpiPduOutletAlertTable'. Each column represents an alert attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
cpiPduOutletAlertMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.4.310.1.1
cpiPduOutletAlertOutletIdGet the outlet ID on the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.4.310.1.2
cpiPduOutletAlertWarnLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.310.1.3
cpiPduOutletAlertWarnHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.310.1.4
cpiPduOutletAlertLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.310.1.5
cpiPduOutletAlertHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU, that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.310.1.6
cpiPduOutletAlertCriticalCurrentSet or get the critical current draw in 1/100 amp of the
outlet on the PDU. Convert the value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.4.310.1.7
.1.3.6.1.4.1.30932.1.10.1.5.5 · 1 row entry · 3 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduProbeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduProbeTable'
This table contains a list of PDU probes that are being monitored
by the PDU.
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of probes attached to the PDUs in
the daisy chain. Each row in the table represents a probe in the daisy chain.
          
The table is index based on the corresponding Probe ID and the source
PDU MAC.
cpiPduProbeEntry row .1.3.6.1.4.1.30932.1.10.1.5.5.1
This entry defines the columns to be populated in the
'cpiPduProbeTable'. Each column represents an attribute of a PDU probe.
This table is indexed by the PDU identifier that is unique
within the PDU and the probe ID.
Column Syntax OID
cpiPduProbeMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.5.5.1.1
cpiPduProbeIdGet the probe ID on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.5.1.2
cpiPduProbeNameSet or get the user defined name of the probe.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.5.5.1.3
.1.3.6.1.4.1.30932.1.10.1.5.10 · 1 row entry · 5 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduSensorTable'
This table contains a list of PDU sensor entries that are being monitored
by the PDU.
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of sensors attached to the PDUs in
the daisy chain. Each row in the table represents a sensor in the daisy chain.
          
The table is index based on the corresponding Sensor ID and the source
PDU MAC.
cpiPduSensorEntry row .1.3.6.1.4.1.30932.1.10.1.5.10.1
This entry defines the columns to be populated in the 'cpiPduSensorTable'.
Each column represents an attribute of a PDU sensor. This table is indexed
by the PDU identifier that is unique within the PDU and the sensor …
Column Syntax OID
cpiPduSensorMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.5.10.1.1
cpiPduSensorIdGet the sensor ID on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.10.1.2
cpiPduSensorNameSet or get the user defined name of the sensor.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.5.10.1.3
cpiPduSensorTypeGet the type of sensor for the entry.Enumeration
Enumerated Values:
1temperature
2humidity
.1.3.6.1.4.1.30932.1.10.1.5.10.1.4
cpiPduSensorValueGet the value of the sensor. For temperature the value is in degrees
Fahrenheit and for humidity the value is percent humidity.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.10.1.5
.1.3.6.1.4.1.30932.1.10.1.5.110 · 1 row entry · 6 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiPduSensorAlertTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiPduSensorAlertTable'
This table contains a list of PDU sensor alert entries that are
being monitored by the PDU.
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of sensors attached to the PDUs in
the daisy chain. Each row in the table represents a sensor in the daisy chain.
          
The table is index based on the corresponding Sonsor ID and the source
PDU MAC.
cpiPduSensorAlertEntry row .1.3.6.1.4.1.30932.1.10.1.5.110.1
This entry defines the columns to be populated in the 'cpiPduSensorAlertTable'.
Each column represents an attribute of a PDU sensor alert. This table
is indexed by the PDU identifier that is unique within the PDU.
Column Syntax OID
cpiPduSensorAlertMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.5.110.1.1
cpiPduSensorAlertSensorIdGet the id of the sensor.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.110.1.2
cpiPduSensorAlertWarnMinSet or get the minimum warning value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.110.1.3
cpiPduSensorAlertWarnMaxSet or get the maximum warning value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.110.1.4
cpiPduSensorAlertMinSet or get the minimum alarm value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.110.1.5
cpiPduSensorAlertMaxSet or get the maximum alarm value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.5.110.1.6
.1.3.6.1.4.1.30932.1.10.1.6.10 · 1 row entry · 2 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiGroupTable'
This table contains a list of PDU group entries that are being monitored
by the PDU.
           
 The table contains one, or many rows, depending upon the number
 of groups that have been configured. Each row in the table represents a
 group.
cpiGroupEntry row .1.3.6.1.4.1.30932.1.10.1.6.10.1
This entry defines the columns to be populated in the
'cpiGroupTable'. This table is indexed by the group identifier that
is unique within the PDU.
Column Syntax OID
cpiGroupEntryIndexThis is the index that indicates the row of the 'cpiPduTable'.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.30932.1.10.1.6.10.1.1
cpiGroupNameName for GROUP 1 of receptacles.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.6.10.1.2
.1.3.6.1.4.1.30932.1.10.1.6.20 · 1 row entry · 4 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiGroupOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiGroupOutletTable'
This table contains a list of PDU group entries.
The table contains zero, one, or many rows, depending upon the number
of groups that have been configured. Each row in the table represents a
group.
cpiGroupOutletEntry row .1.3.6.1.4.1.30932.1.10.1.6.20.1
This entry defines the columns to be populated in the
'cpiGroupTable'. This table is indexed by the group identifier that
is unique within the PDU.
Column Syntax OID
cpiGroupOutletEntryIndexThis is the index that indicates the row of the 'cpiGroupOutletTable'.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.30932.1.10.1.6.20.1.1
cpiGroupOutletGroupIDName for GROUP 1 of receptacles.SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.30932.1.10.1.6.20.1.2
cpiGroupOutletPDUMacMAC of PDU the outlet is on.SNMPv2-TCMacAddressr/w
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.6.20.1.3
cpiGroupOutletOutletIdThe ID of the outlet on the PDU.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.6.20.1.4
.1.3.6.1.4.1.30932.1.10.1.7.90 · 1 row entry · 6 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiEasConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiEasConfigTable'
This table contains a list of electronic locks that are connected to the PDU
and allows for the configuration of the various settings associated with the
EAS (electronic access system).
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of locks attached to the PDUs in
the daisy chain. Each row in the table represents a lock in the daisy chain.
          
The table is index based on the corresponding lock ID and the source
PDU MAC.
cpiEasConfigEntry row .1.3.6.1.4.1.30932.1.10.1.7.90.1
This entry defines the columns to be populated in the 'cpiEasTable'.
Each column represents an attribute of a PDU lock. This table is indexed
by the PDU identifier that is unique within the PDU and the lock ID.
Column Syntax OID
cpiEasConfigLockMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.7.90.1.1
cpiEasConfigEnabledIndicates whether the Electronic Access System (EAS) is available on the PDU.Enumeration
Enumerated Values:
0not-available
1available
.1.3.6.1.4.1.30932.1.10.1.7.90.1.2
cpiEasFrontLockEnabledEnables the front lock on the EAS.Enumerationr/w
Enumerated Values:
0disabled
1enabled
.1.3.6.1.4.1.30932.1.10.1.7.90.1.3
cpiEasRearLockEnabledEnables the rear lock on the EAS.Enumerationr/w
Enumerated Values:
0disabled
1enabled
.1.3.6.1.4.1.30932.1.10.1.7.90.1.4
cpiEasLockHoldOpenTimeThe length of time in seconds to hold open the lock after a successful card scan.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.7.90.1.5
cpiEasDoorOpenAlarmTimeThe length of time in minutes before alerting that the door is open.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.10.1.7.90.1.6

cpiEasTable

table
.1.3.6.1.4.1.30932.1.10.1.7.100 · 1 row entry · 11 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk cpiEasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::cpiEasTable'
This table contains a list of electronic locks that are connected to the PDU
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of locks attached to the PDUs in
the daisy chain. Each row in the table represents a lock in the daisy chain.
          
The table is index based on the corresponding lock ID and the source
PDU MAC.
cpiEasEntry row .1.3.6.1.4.1.30932.1.10.1.7.100.1
This entry defines the columns to be populated in the 'cpiEasTable'.
Each column represents an attribute of a PDU lock. This table is indexed
by the PDU identifier that is unique within the PDU and the lock ID.
Column Syntax OID
cpiPduLockMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.10.1.7.100.1.1
cpiPduLockIdGet the lock ID on the PDU.Enumeration
Enumerated Values:
1front
2rear
.1.3.6.1.4.1.30932.1.10.1.7.100.1.2
cpiPduEasStatusIndicates if the Electronic Access Control system is ready, inactive, or in an error state.

If the status is Inactive, then the lock is not enabled on the PDU.
If the status is Error, then the cpiEasError…
Enumeration
Enumerated Values:
0inactive
1ready
2error
.1.3.6.1.4.1.30932.1.10.1.7.100.1.3
cpiPduDoorStatusIndicates if the door sensor is closed or open.Enumeration
Enumerated Values:
0closed
1open
.1.3.6.1.4.1.30932.1.10.1.7.100.1.4
cpiPduLockStatusIndicates if the lock is closed or open.Enumeration
Enumerated Values:
0closed
1open
.1.3.6.1.4.1.30932.1.10.1.7.100.1.5
cpiPduForceStatusIndicates if the cabinet was forced open by a command from the webUI or SNMP interfaces.Enumeration
Enumerated Values:
0normal
1force
.1.3.6.1.4.1.30932.1.10.1.7.100.1.6
cpiPduTamperStatusIndicates if the cabinet is currently unlocked/opened without an authorization scan.Enumeration
Enumerated Values:
0normal
1tamper
.1.3.6.1.4.1.30932.1.10.1.7.100.1.7
cpiEasErrorGets the error code associated for the electronic lock system. The possible error codes are:

196608 (0x00030000
) - No error, the lock is working and ready.
167968771 (0x0a030003
) - The lock is not enabl…
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.30932.1.10.1.7.100.1.8
cpiEasLockVerGets the version of the electronic lock control.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.7.100.1.9
cpiEasLockSerialNumberGet the serial number of the electronic lock control.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.10.1.7.100.1.10
cpiPduLockCtrlTells the system to open the locks on the cabinet.Enumerationr/w
Enumerated Values:
0close
1open
.1.3.6.1.4.1.30932.1.10.1.7.100.1.11

saIpv4Table

table
.1.3.6.1.4.1.30932.1.20.5.5.11 · 1 row entry · 11 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saIpv4Table
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saIpv4Table'
This table contains a list of PDU IPv4 entries that are attached through
the SecureArray connection. 
          
The Row ID field is used as an index on the table.  The Row ID is not
guaranteed to be the same PDU from one instance in time to another.  It 
is recommended to utilize the MAC address as a universally unique ID.
saIpv4Entry row .1.3.6.1.4.1.30932.1.20.5.5.11.1
This entry defines the columns to be populated in the
'saIpv4Table'. Each column represents an attribute of a PDU.
Indexes
Column Syntax OID
saIpv4RowIdThe Row ID of the PDU.Integer32
Constraints:
range: 1-48
.1.3.6.1.4.1.30932.1.20.5.5.11.1.1
saIpv4PduMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.5.5.11.1.2
saIpV4EnableControls whether the IPv4 network interface is enabled.Enumerationr/w
Enumerated Values:
0disabled
1enabled
.1.3.6.1.4.1.30932.1.20.5.5.11.1.3
saIpv4PduIPSet or get the IPv4 address of the PDU.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.5.5.11.1.4
saAutoIPControls whether the IPv4 address is retrieved from a
DHCP server or is set statically.
Enumerationr/w
Enumerated Values:
0static
1dynamic
.1.3.6.1.4.1.30932.1.20.5.5.11.1.5
saAutoDNSControls whether the DNS addresses are retrieved from
a DHCP server or are set statically.
Enumerationr/w
Enumerated Values:
0static
1dynamic
.1.3.6.1.4.1.30932.1.20.5.5.11.1.6
saSubnetMaskThe subnet mask associated with the IPv4 address of this
entry. The value of the mask is an IPv4 address with all the
network bits set to 1 and all the hosts bits set to 0.
SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.5.5.11.1.7
saGatewaySet or get the IPv4 address of the gateway router for the PDU.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.5.5.11.1.8
saDns1Set or get the IPv4 address of the first DNS entry for the PDU.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.5.5.11.1.9
saDns2Set or get the IPv4 address of the second DNS entry for the PDU.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.5.5.11.1.10
saDns3Set or get the IPv4 address of the third DNS entry for the PDU.SNMPv2-SMIIpAddressr/w
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.5.5.11.1.11

saPduTable

table
.1.3.6.1.4.1.30932.1.20.10.11 · 1 row entry · 19 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduTable'
This table contains a list of PDU entries that are attached through
the SecureArray connection. 
          
The table contains one, or many rows, depending upon the 
number of PDUs being monitored. Each row in the table represents a PDU 
in the SecureArray.
          
This table always contains at least one entry and a maximum of 48 entries.
          
The Row ID field is used as an index on the table.  The Row ID is not
guaranteed to be the same PDU from one instance in time to another.  It 
is recommended to utilize the MAC address as a universally unique ID.
saPduEntry row .1.3.6.1.4.1.30932.1.20.10.11.1
This entry defines the columns to be populated in the
'saPduTable'. Each column represents an attribute of a PDU.
Indexes
Column Syntax OID
saPduRowIdThe Row ID of the PDU.Integer32
Constraints:
range: 1-48
.1.3.6.1.4.1.30932.1.20.10.11.1.1
saPduMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.10.11.1.2
saPduModelGet the model number of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.3
saPduNameSet or get the user assigned name of the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.4
saPduDescriptionSet or get the user assigned description of the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.5
saPduHasBranchMonitorAn indicator if the PDU supports monitoring voltage, and current on branches in the PDU.Enumeration
Enumerated Values:
0notsupported
1supported
.1.3.6.1.4.1.30932.1.20.10.11.1.6
saPduHasOutletMonitorAn indicator if the PDU supports monitoring current on the individual outlets in the PDU.Enumeration
Enumerated Values:
0notsupported
1supported
.1.3.6.1.4.1.30932.1.20.10.11.1.7
saPduHasOutletControlAn indicator if the PDU supports control (turn on/off) individual outlets in the PDU.Enumeration
Enumerated Values:
0notsupported
1supported
.1.3.6.1.4.1.30932.1.20.10.11.1.8
saPduNumberBranchesGet the number of branches (breakers) in the PDU.Integer32
Constraints:
range: 0-12
.1.3.6.1.4.1.30932.1.20.10.11.1.9
saPduNumberOutletsGet the number of outlets in the PDU.Integer32
Constraints:
range: 0-48
.1.3.6.1.4.1.30932.1.20.10.11.1.10
saPduOutOfServiceSet or get whether the PDU is in-service.Enumerationr/w
Enumerated Values:
0inservice
1outofservice
.1.3.6.1.4.1.30932.1.20.10.11.1.11
saPduVersionGet the firmware version number of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.12
saPduUpgradeAn indicator if the PDU firmware is being upgraded.Enumeration
Enumerated Values:
0no
1yes
.1.3.6.1.4.1.30932.1.20.10.11.1.13
saPduChainRoleGet the role of the PDU in a SecureArray.Enumerationr/w
Enumerated Values:
0secondary
1primary
2alternate
.1.3.6.1.4.1.30932.1.20.10.11.1.14
saPduIpGet IP address of the PDU.SNMPv2-SMIIpAddress
Type Constraints:
range: 4
.1.3.6.1.4.1.30932.1.20.10.11.1.15
saPduIpv6Get the IPv6 address of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.16
saPduTotalPowerGet the power in volt-amps for the entire PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.10.11.1.17
saPduCabinetIdGet/set the name of the cabinet the PDU is in.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.18
saPduSerialNumGet the serial number of the PDU.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.10.11.1.19
.1.3.6.1.4.1.30932.1.20.15.11 · 1 row entry · 5 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduLineTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduLineTable'
This table contains a list of PDU line entries that are being
monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of input lines. Each row 
in the table represents a PDU line in the SecureArray.
          
The table is indexed based on the corresponding Line Row ID.
saPduLineEntry row .1.3.6.1.4.1.30932.1.20.15.11.1
This entry defines the columns to be populated in the
'saPduLineTable'. Each column represents an attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Indexes
Column Syntax OID
saPduLineRowIdGet the ID of the input line on the PDU.Integer32
Constraints:
range: 0-512
.1.3.6.1.4.1.30932.1.20.15.11.1.1
saPduLineIdGet the ID of the input line on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.15.11.1.2
saPduLineMacGet the MAC address of the PDU that owns the input line.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.15.11.1.3
saPduLinePduNameGet the MAC address of the PDU that owns the input line.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.15.11.1.4
saPduLineCurrentGet current draw in 1/100 amp of the line on the PDU. Convert the value by dividing by 100.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.15.11.1.5
.1.3.6.1.4.1.30932.1.20.20.11 · 1 row entry · 11 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduBranchTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduBranchTable'
This table contains a list of PDU branch entries that are being
monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of branches per PDU. Each row 
in the table represents a PDU branch in the daisy chain.
          
The table is indexed based on the corresponding Branch ID and
the source PDU MAC.
saPduBranchEntry row .1.3.6.1.4.1.30932.1.20.20.11.1
This entry defines the columns to be populated in the
'saPduBranchEntry'. Each column represents an attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
saPduBranchRowIdGet the Row ID of the branch on the owning PDU.Integer32
Constraints:
range: 0-768
.1.3.6.1.4.1.30932.1.20.20.11.1.1
saPduBranchIdGet the ID of the branch on the owning PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.11.1.2
saPduBranchMacGet the MAC address of the PDU that owns the branch.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.20.11.1.3
saPduBranchPduNameGet the MAC address of the PDU that owns the input line.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.20.11.1.4
saPduBranchCurrentGet the current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.11.1.5
saPduBranchMaxCurrentGet the maximum current draw in 1/100 amp of the branch on the PDU. Convert the value by dividing by 100.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.11.1.6
saPduBranchVoltageGet the voltage in 1/10 volts of the branch on the PDU. Convert the value by dividing by 10.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.11.1.7
saPduBranchPowerGet the power in volt-amps for the branch.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.11.1.8
saPduBranchPowerFactorGet the power factor for the branch.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.11.1.9
saPduBranchStatusGet the alarm status of the branch.Enumeration
Enumerated Values:
0noalarm
1warning
2alarm
.1.3.6.1.4.1.30932.1.20.20.11.1.10
saPduBranchEnergyGet the branch energy accumulated in decaVA-secs, divide by 360 to obtain VA-hr.SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.30932.1.20.20.11.1.11
.1.3.6.1.4.1.30932.1.20.20.12 · 1 row entry · 13 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduBranchAlertTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduBranchAlertTable'
This table contains a list of PDU branch alert entries that are
being monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of branches per PDU. Each row 
in the table represents a PDU branch in the daisy chain.
          
The table is indexed based on the corresponding Branch ID and the
source PDU MAC.
saPduBranchAlertEntry row .1.3.6.1.4.1.30932.1.20.20.12.1
This entry defines the columns to be populated in the
'saPduBranchAlertTable'. Each column represents an alert attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
saPduBranchAlertRowIdGet the Row ID of the branch on the owning PDU.Integer32
Constraints:
range: 0-768
.1.3.6.1.4.1.30932.1.20.20.12.1.1
saPduBranchAlertMacGet the MAC address of the PDU that owns the branch.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.20.12.1.2
saPduBranchAlertPduNameGet the MAC address of the PDU that owns the input line.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.20.12.1.3
saPduBranchAlertBranchIdGet the branch of the owning PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.4
saPduBranchAlertWarnLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.5
saPduBranchAlertWarnHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.6
saPduBranchAlertLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.7
saPduBranchAlertHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU, that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.8
saPduBranchAlertCriticalCurrentSet or get the critical current draw in 1/100 amp of the
branch on the PDU. Convert the value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.9
saPduBranchAlertWarnLoVoltSet or get the minimum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.10
saPduBranchAlertWarnHiVoltSet or get the maximum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.11
saPduBranchAlertLoVoltSet or get the minimum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.12
saPduBranchAlertHiVoltSet or get the maximum voltage that the branch can reach
up to in 1/10th volts, 0=ignore. Convert the value by
dividing by 10.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.20.12.1.13
.1.3.6.1.4.1.30932.1.20.25.11 · 1 row entry · 13 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduOutletTable'
This table contains a list of PDU outlet entries that are being
monitored by the PDU.
          
The table contains one, or many rows, depending upon the number
of PDUs being monitored and the number of outlets on each PDU. 
Each row in the table represents a PDU outlet in the SecureArray.
saPduOutletEntry row .1.3.6.1.4.1.30932.1.20.25.11.1
This entry defines the columns to be populated in the
'saPduOutletTable'. Each column represents an outlet of a PDU.
This table is indexed by the PDU Outlet identifier that is unique
within the PDU.
Column Syntax OID
saPduOutletRowIdGet the ID of the outlet on the PDU.Integer32
Constraints:
range: 1-4096
.1.3.6.1.4.1.30932.1.20.25.11.1.1
saPduOutletMacGet the MAC address of the source PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.25.11.1.2
saPduOutletIdGet the ID of the outlet on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.11.1.3
saPduOutletBranchIdGet the ID of the branch the outlet is associated with on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.11.1.4
saPduOutletNameSet or get the user supplied name of the outlet on the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.25.11.1.5
saPduOutletDescriptionSet or get the user supplied description of the outlet on the PDU.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.25.11.1.6
saPduOutletCurrentGet the current draw in 1/100 amp of the outlet on the PDU. Convert
the value by dividing by 100.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.11.1.7
saPduOutletVoltageGet the voltage in 1/10 volts of the outlet on the PDU. Convert the
value by dividing by 10.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.11.1.8
saPduOutletPowerThe power in Volt-Amps of the outlet on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.11.1.9
saPduOutletStatusGet the alarm status of the outlet.Enumeration
Enumerated Values:
0noalarm
1warning
2alarm
.1.3.6.1.4.1.30932.1.20.25.11.1.10
saPduOutletEnergyGet the outlet energy accumulated in decaWatt-secs, divide by 360 to obtain Watt-hr.SNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.30932.1.20.25.11.1.11
saPduOutletControlSet or get power control to the outlet.Enumerationr/w
Enumerated Values:
0off
1on
.1.3.6.1.4.1.30932.1.20.25.11.1.12
saPduOutletResetSet or get reset power to the outlet.Enumerationr/w
Enumerated Values:
0nominal
1reset
.1.3.6.1.4.1.30932.1.20.25.11.1.13
.1.3.6.1.4.1.30932.1.20.25.20 · 1 row entry · 5 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduOutletConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduOutletConfigTable'
This table contains a list of PDU outlet configuration entries
that are being monitored by the PDU.
          
 The table contains one, or many rows, depending upon the number
 of PDUs being monitored and the number of outlets per PDU. Each row 
 in the table represents a PDU outlet in the daisy chain.
           
 The table is indexed based on the corresponding Outlet ID and
 the source PDU MAC.
saPduOutletConfigEntry row .1.3.6.1.4.1.30932.1.20.25.20.1
This entry defines the columns to be populated in the
'cpiPduOutletConfigTable'. Each column represents an
configurable attribute of an outlet in the PDU. This
table is indexed by the PDU Line identifier that is
uni…
Column Syntax OID
saPduOutletConfigOutletRowIdGet the ID of the outlet on the PDU.Integer32
Constraints:
range: 1-4096
.1.3.6.1.4.1.30932.1.20.25.20.1.1
saPduOutletConfigMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.25.20.1.2
saPduOutletConfigOutletIdGet the ID of the outlet on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.20.1.3
saPduOutletConfigOnDelaySet or get the outlet power-on delay in seconds.Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.30932.1.20.25.20.1.4
saPduOutletConfigResetDelaySet or get the outlet reset delay in seconds.Integer32r/w
Constraints:
range: 0-255
.1.3.6.1.4.1.30932.1.20.25.20.1.5
.1.3.6.1.4.1.30932.1.20.25.30 · 1 row entry · 8 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduOutletAlertTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduOutletAlertTable'
This table contains a list of PDU outlet alert entries that are
being monitored by the PDU.
          
 The table contains one, or many rows, depending upon the number
 of PDUs being monitored and the number of outlets per PDU. Each row 
 in the table represents a PDU outlet in the daisy chain.
saPduOutletAlertEntry row .1.3.6.1.4.1.30932.1.20.25.30.1
This entry defines the columns to be populated in the
'saPduOutletAlertTable'. Each column represents an alert attribute of a PDU.
This table is indexed by the PDU Line identifier that is unique
within the PDU.
Column Syntax OID
saPduOutletAlertOutletRowIdGet the outlet ID on the PDU.Integer32
Constraints:
range: 1-4096
.1.3.6.1.4.1.30932.1.20.25.30.1.1
saPduOutletAlertMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.25.30.1.2
saPduOutletAlertOutletIdGet the outlet ID on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.30.1.3
saPduOutletAlertWarnLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.30.1.4
saPduOutletAlertWarnHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers a warning condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.30.1.5
saPduOutletAlertLoCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.30.1.6
saPduOutletAlertHiCurrentSet or get the current draw in 1/100 amp of the branch on
the PDU, that triggers an alarm condition. Convert the
value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.30.1.7
saPduOutletAlertCriticalCurrentSet or get the critical current draw in 1/100 amp of the
outlet on the PDU. Convert the value by dividing by 100.
SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.25.30.1.8
.1.3.6.1.4.1.30932.1.20.30.10 · 1 row entry · 6 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduSensorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduSensorTable'
This table contains a list of PDU sensor entries that are being monitored
by the PDU.
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of sensors attached to the PDUs in
the daisy chain. Each row in the table represents a sensor in the daisy chain.
saPduSensorEntry row .1.3.6.1.4.1.30932.1.20.30.10.1
This entry defines the columns to be populated in the 'saPduSensorTable'.
Each column represents an attribute of a PDU sensor. This table is indexed
by the PDU identifier that is unique within the PDU and the sensor I…
Column Syntax OID
saPduSensorRowIdGet the sensor ID on the PDU.Integer32
Constraints:
range: 1-8192
.1.3.6.1.4.1.30932.1.20.30.10.1.1
saPduSensorMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.30.10.1.2
saPduSensorIdGet the sensor ID on the PDU.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.10.1.3
saPduSensorNameSet or get the user defined name of the sensor.SNMPv2-TCDisplayStringr/w
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.30.10.1.4
saPduSensorTypeGet the type of sensor for the entry.Enumeration
Enumerated Values:
1temperature
2humidity
.1.3.6.1.4.1.30932.1.20.30.10.1.5
saPduSensorValueGet the value of the sensor. For temperature the value is in degrees
Fahrenheit and for humidity the value is percent humidity.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.10.1.6
.1.3.6.1.4.1.30932.1.20.30.20 · 1 row entry · 7 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saPduSensorAlertTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saPduSensorAlertTable'
This table contains a list of PDU sensor alert entries that are
being monitored by the PDU.
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of sensors attached to the PDUs in
the daisy chain. Each row in the table represents a sensor in the daisy chain.
saPduSensorAlertEntry row .1.3.6.1.4.1.30932.1.20.30.20.1
This entry defines the columns to be populated in the 'cpiPduSensorAlertTable'.
Each column represents an attribute of a PDU sensor alert. This table
is indexed by the PDU identifier that is unique within the PDU.
Column Syntax OID
saPduSensorAlertSensorRowIdGet the id of the sensor.Integer32
Constraints:
range: 1-4096
.1.3.6.1.4.1.30932.1.20.30.20.1.1
saPduSensorAlertMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.30.20.1.2
saPduSensorAlertSensorIdGet the id of the sensor.SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.20.1.3
saPduSensorAlertWarnMinSet or get the minimum warning value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.20.1.4
saPduSensorAlertWarnMaxSet or get the maximum warning value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.20.1.5
saPduSensorAlertMinSet or get the minimum alarm value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.20.1.6
saPduSensorAlertMaxSet or get the maximum alarm value of the sensor.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.30.20.1.7
.1.3.6.1.4.1.30932.1.20.40.20 · 1 row entry · 7 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saEasConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saEasConfigTable'
This table contains a list of electronic locks that are connected to the PDU
and allows for the configuration of the various settings associated with the
EAS (electronic access system).
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of locks attached to the PDUs in
the daisy chain. Each row in the table represents a lock in the daisy chain.
          
The table is index based on the corresponding lock ID and the source
PDU MAC.
saEasConfigEntry row .1.3.6.1.4.1.30932.1.20.40.20.1
This entry defines the columns to be populated in the 'cpiEasTable'.
Each column represents an attribute of a PDU lock. This table is indexed
by the PDU identifier that is unique within the PDU and the lock ID.
Column Syntax OID
saEasConfigLockRowIdGet the MAC address of the PDU.Integer32
Constraints:
range: 1-128
.1.3.6.1.4.1.30932.1.20.40.20.1.1
saEasConfigLockMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.40.20.1.2
saEasConfigEnabledIndicates whether the Electronic Access System (EAS) is available on the PDU.Enumeration
Enumerated Values:
0not-available
1available
.1.3.6.1.4.1.30932.1.20.40.20.1.3
saEasFrontLockEnabledEnables the front lock on the EAS.Enumerationr/w
Enumerated Values:
0disabled
1enabled
.1.3.6.1.4.1.30932.1.20.40.20.1.4
saEasRearLockEnabledEnables the rear lock on the EAS.Enumerationr/w
Enumerated Values:
0disabled
1enabled
.1.3.6.1.4.1.30932.1.20.40.20.1.5
saEasLockHoldOpenTimeThe length of time in seconds to hold open the lock after a successful card scan.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.40.20.1.6
saEasDoorOpenAlarmTimeThe length of time in minutes before alerting that the door is open.SNMPv2-SMIInteger32r/w
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.30932.1.20.40.20.1.7

saEasTable

table
.1.3.6.1.4.1.30932.1.20.40.30 · 1 row entry · 12 columns
Uses the chatsworth variant from /opt/observium/mibs/chatsworth.
Command help
Walk saEasTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPI-UNIFIED-MIB' -M '/opt/observium/mibs/chatsworth:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPI-UNIFIED-MIB::saEasTable'
This table contains a list of electronic locks that are connected to the PDU
          
The table contains zero, one, or many rows, depending upon the number
of PDUs being monitored and the number of locks attached to the PDUs in
the daisy chain. Each row in the table represents a lock in the daisy chain.
          
The table is index based on the corresponding lock ID and the source
PDU MAC.
saEasEntry row .1.3.6.1.4.1.30932.1.20.40.30.1
This entry defines the columns to be populated in the 'cpiEasTable'.
Each column represents an attribute of a PDU lock. This table is indexed
by the PDU identifier that is unique within the PDU and the lock ID.
Indexes
Column Syntax OID
saPduLockRowIdGet the lock ID on the PDU.Integer32
Constraints:
range: 0-128
.1.3.6.1.4.1.30932.1.20.40.30.1.1
saPduLockMacGet the MAC address of the PDU.SNMPv2-TCMacAddress
Type Constraints:
range: 6
Description:
Represents an 802 MAC address represented in the
`canonical' order defined by IEEE 802.1a, i.e., as if it
were transmitted least significant bit first, even though
802.5 (in contrast to other 802.x protocols) requires M…
.1.3.6.1.4.1.30932.1.20.40.30.1.2
saPduLockIdGet the lock ID on the PDU.Enumeration
Enumerated Values:
1front
2rear
.1.3.6.1.4.1.30932.1.20.40.30.1.3
saPduEasStatusIndicates if the Electronic Access Control system is ready, inactive, or in an error state.

If the status is Inactive, then the lock is not enabled on the PDU.
If the status is Error, then the cpiEasError…
Enumeration
Enumerated Values:
0inactive
1ready
2error
.1.3.6.1.4.1.30932.1.20.40.30.1.4
saPduDoorStatusIndicates if the door sensor is closed or open.Enumeration
Enumerated Values:
0closed
1open
.1.3.6.1.4.1.30932.1.20.40.30.1.5
saPduLockStatusIndicates if the lock is closed or open.Enumeration
Enumerated Values:
0closed
1open
.1.3.6.1.4.1.30932.1.20.40.30.1.6
saPduForceStatusIndicates if the cabinet was forced open by a command from the webUI or SNMP interfaces.Enumeration
Enumerated Values:
0normal
1force
.1.3.6.1.4.1.30932.1.20.40.30.1.7
saPduTamperStatusIndicates if the cabinet is currently unlocked/opened without an authorization scan.Enumeration
Enumerated Values:
0normal
1tamper
.1.3.6.1.4.1.30932.1.20.40.30.1.8
saEasErrorGets the error code associated for the electronic lock system. The possible error codes are:

196608 (0x00030000
) - No error, the lock is working and ready.
167968771 (0x0a030003
) - The lock is not enabl…
SNMPv2-SMIUnsigned32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.30932.1.20.40.30.1.9
saEasLockVerGets the version of the electronic lock control.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.40.30.1.10
saEasLockSerialNumberGet the serial number of the electronic lock control.SNMPv2-TCDisplayString
Type Constraints:
range: 0..255
Description:
Represents textual information taken from the NVT ASCII

character set, as defined in pages 4, 10-11 of RFC 854.

To summarize RFC 854, the NVT ASCII repertoire specifies:

- the use of c…
.1.3.6.1.4.1.30932.1.20.40.30.1.11
saPduLockCtrlTells the system to open the locks on the cabinet.Enumerationr/w
Enumerated Values:
0close
1open
.1.3.6.1.4.1.30932.1.20.40.30.1.12