CISCO-UNIFIED-COMPUTING-GRAPHICS-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
2
Rows
2
Columns
49
cucsGraphicsCardTable
table.1.3.6.1.4.1.9.9.719.1.73.1
·
1 row entry
·
30 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cucsGraphicsCardTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-UNIFIED-COMPUTING-GRAPHICS-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-UNIFIED-COMPUTING-GRAPHICS-MIB::cucsGraphicsCardTable'
Cisco UCS graphics:Card managed object table
Entry for the cucsGraphicsCardTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId | .1.3.6.1.4.1.9.9.719.1.73.1.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:dn managed object property
|
CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn | .1.3.6.1.4.1.9.9.719.1.73.1.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:deviceId managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:id managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:isSupported managed object property
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.719.1.73.1.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:lc managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsFsmLifecycle Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:operQualifierReason managed
object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:operState managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:operability managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:pciAddr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:pciSlot managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:perf managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:power managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:presence managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:revision managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:subDeviceId managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.19 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:subVendorId managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.20 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:thermal managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.21 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.22 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:vendorId managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.23 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:voltage managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.24 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:locationDn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.25 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:stepping managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.26 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:expanderSlot managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.27 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:firmwareVersion managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.28 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:pciAddrList managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.1.1.29 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Card:mode managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsGraphicsGpuMode Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.1.1.30 |
.1.3.6.1.4.1.9.9.719.1.73.2
·
1 row entry
·
19 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cucsGraphicsControllerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-UNIFIED-COMPUTING-GRAPHICS-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-UNIFIED-COMPUTING-GRAPHICS-MIB::cucsGraphicsControllerTable'
Cisco UCS graphics:Controller managed object table
Entry for the cucsGraphicsControllerTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Instance identifier of the managed object.
|
CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectId | .1.3.6.1.4.1.9.9.719.1.73.2.1.1 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:dn managed object property
|
CISCO-UNIFIED-COMPUTING-MIBCucsManagedObjectDn | .1.3.6.1.4.1.9.9.719.1.73.2.1.2 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:rn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.3 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:id managed object property
|
SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.4 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:model managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.5 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:operQualifierReason
managed object property |
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.6 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:operState managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.7 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:operability managed
object property |
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentOperability Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.8 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:pciAddr managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.9 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:pciSlot managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.10 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:perf managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.11 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:power managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPowerState Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.12 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:presence managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentPresence Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.13 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:revision managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.14 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:serial managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.15 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:thermal managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.16 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:vendor managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.17 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:voltage managed object property
|
CISCO-UNIFIED-COMPUTING-TC-MIBCucsEquipmentSensorThresholdStatus Type Values:
|
.1.3.6.1.4.1.9.9.719.1.73.2.1.18 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Cisco UCS graphics:Controller:locationDn managed object property
|
SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 |
.1.3.6.1.4.1.9.9.719.1.73.2.1.19 |