CISCO-FIREPOWER-BMC-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
1
Rows
1
Columns
19
cfprBmcSELCounterTable
table.1.3.6.1.4.1.9.9.826.1.6.1
·
1 row entry
·
19 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cfprBmcSELCounterTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FIREPOWER-BMC-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FIREPOWER-BMC-MIB::cfprBmcSELCounterTable'
Cisco Firepower bmc:SELCounter managed object table
Entry for the cfprBmcSELCounterTable table.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| cfprBmcSELCounterInstanceIdInstance identifier of the managed object. | CISCO-FIREPOWER-MIBCfprManagedObjectId | .1.3.6.1.4.1.9.9.826.1.6.1.1.1 | ||||||||||||||
| cfprBmcSELCounterDnCisco Firepower bmc:SELCounter:dn managed object property | CISCO-FIREPOWER-MIBCfprManagedObjectDn | .1.3.6.1.4.1.9.9.826.1.6.1.1.2 | ||||||||||||||
| cfprBmcSELCounterRnCisco Firepower bmc:SELCounter:rn managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.3 | ||||||||||||||
| cfprBmcSELCounterBitmaskCisco Firepower bmc:SELCounter:bitmask managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.4 | ||||||||||||||
| cfprBmcSELCounterCollIntervalCisco Firepower bmc:SELCounter:collInterval managed object property | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.9.9.826.1.6.1.1.5 | ||||||||||||||
| cfprBmcSELCounterContClassIdCisco Firepower bmc:SELCounter:contClassId managed object property | CISCO-FIREPOWER-TC-MIBCfprBmcSELCntEqptClassId Type Values:
| .1.3.6.1.4.1.9.9.826.1.6.1.1.6 | ||||||||||||||
| cfprBmcSELCounterContInstIdCisco Firepower bmc:SELCounter:contInstId managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.7 | ||||||||||||||
| cfprBmcSELCounterContInstIdPropIdCisco Firepower bmc:SELCounter:contInstIdPropId managed object property | CISCO-FIREPOWER-TC-MIBCfprBmcSELCntEqptInstIdPropId Type Values:
| .1.3.6.1.4.1.9.9.826.1.6.1.1.8 | ||||||||||||||
| cfprBmcSELCounterEqptClassIdCisco Firepower bmc:SELCounter:eqptClassId managed object property | CISCO-FIREPOWER-TC-MIBCfprBmcSELCntEqptClassId Type Values:
| .1.3.6.1.4.1.9.9.826.1.6.1.1.9 | ||||||||||||||
| cfprBmcSELCounterEqptInstIdCisco Firepower bmc:SELCounter:eqptInstId managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.10 | ||||||||||||||
| cfprBmcSELCounterEqptInstIdPropIdCisco Firepower bmc:SELCounter:eqptInstIdPropId managed object property | CISCO-FIREPOWER-TC-MIBCfprBmcSELCntEqptInstIdPropId Type Values:
| .1.3.6.1.4.1.9.9.826.1.6.1.1.11 | ||||||||||||||
| cfprBmcSELCounterGlobalIdCisco Firepower bmc:SELCounter:globalId managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.12 | ||||||||||||||
| cfprBmcSELCounterLocalIdCisco Firepower bmc:SELCounter:localId managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.13 | ||||||||||||||
| cfprBmcSELCounterPcGlobalIdCisco Firepower bmc:SELCounter:pcGlobalId managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.14 | ||||||||||||||
| cfprBmcSELCounterPcLocalIdCisco Firepower bmc:SELCounter:pcLocalId managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.15 | ||||||||||||||
| cfprBmcSELCounterStatsClassIdCisco Firepower bmc:SELCounter:statsClassId managed object property | CISCO-FIREPOWER-TC-MIBCfprBmcSELCntStatsClassId Type Values:
| .1.3.6.1.4.1.9.9.826.1.6.1.1.16 | ||||||||||||||
| cfprBmcSELCounterStatsPropIdCisco Firepower bmc:SELCounter:statsPropId managed object property | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.9.9.826.1.6.1.1.17 | ||||||||||||||
| cfprBmcSELCounterThresholdCisco Firepower bmc:SELCounter:threshold managed object property | SNMPv2-SMIGauge32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.9.9.826.1.6.1.1.18 | ||||||||||||||
| cfprBmcSELCounterValueCisco Firepower bmc:SELCounter:value managed object property | SNMP-FRAMEWORK-MIBSnmpAdminString Type Constraints: range: 0..255 | .1.3.6.1.4.1.9.9.826.1.6.1.1.19 |