CISCO-EXT-SCSI-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
4
Rows
4
Columns
15
.1.3.6.1.4.1.9.9.299.1.1.1
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk ciscoExtScsiGenInstanceTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-EXT-SCSI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-EXT-SCSI-MIB::ciscoExtScsiGenInstanceTable'
This table is an extension to the
ciscoScsiInstanceTable defined in
the CISCO-SCSI-MIB.
The ciscoScsiInstIndex values are
assigned as follows:
1. there is one ciscoScsiInstIndex value
defined per disk group associated with the
system.
2. there is one ciscoScsiInstIndex value
defined per line-card.
3. there is one ciscoScsiInstIndex value
defined for the supervisor as a whole.
All ciscoScsiInstIndex values defined
for type 1 above have a disk group
ID associated with them, which is that
of the corresponding disk group. This
value is present in the corresponding
instance of ciscoExtScsiDiskGrpId object.
The corresponding instance of
ciscoExtScsiLineCardOrSup object will
contain the entity physical index of
the line card to which it is associated.
For ciscoScsiInstIndex values defined
for type 2, the ciscoExtScsiDiskGrpId
object is not meaningful and will be
empty. The corresponding instance of
ciscoExtScsiLineCardOrSup object will
contain the entity physical index value
of that line card.
For the ciscoScsiInstIndex value defined
for type 3, the ciscoExtScsiDiskGrpId
object is not meaningful and will be empty.
The corresponding instance of
ciscoExtScsiLineCardOrSup object will
contain the entity physical index value
of the supervisor.
An entry contains disk group ID and/or entity
physical index of a disk group/line card/supervisor
depending on the ciscoScsiInstIndex value
assignment as defined above. There is a one-to-one
mapping between an entry he…
physical index of a disk group/line card/supervisor
depending on the ciscoScsiInstIndex value
assignment as defined above. There is a one-to-one
mapping between an entry he…
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
| ciscoExtScsiDiskGrpIdThis object contains the disk group ID of a disk group if the value of the ciscoScsiInstIndex corresponds to that of a disk group. Otherwise, this object will contain a null string. | OctetString Constraints: range: 0-0range: 64-64 | .1.3.6.1.4.1.9.9.299.1.1.1.1.1 |
| ciscoExtScsiLineCardOrSupThis object contains the entity physical index of a line card if the ciscoScsiInstIndex value corresponds to that of a disk group or a line card. Otherwise, this object contains the entity physical index… | Unsigned32 Constraints: range: 1-2147483647 | .1.3.6.1.4.1.9.9.299.1.1.1.1.2 |
.1.3.6.1.4.1.9.9.299.1.1.6
·
1 row entry
·
6 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk ciscoExtScsiIntrDiscTgtTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-EXT-SCSI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-EXT-SCSI-MIB::ciscoExtScsiIntrDiscTgtTable'
This table is an extension to the ciscoScsiDscTgtTable.
An entry (conceptual row) in this table.
Indexes
No indexes recorded
| Column | Syntax | OID |
|---|---|---|
| ciscoExtScsiIntrDiscTgtVsanIdThe VSAN to which this target belongs to. | CISCO-ST-TCVsanIndex Type Constraints: range: 1..4094 | .1.3.6.1.4.1.9.9.299.1.1.6.1.1 |
| ciscoExtScsiIntrDiscTgtDevTypeThe device type of the SCSI target. | SNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.9.9.299.1.1.6.1.2 |
| ciscoExtScsiIntrDiscTgtVendorIdThe vendor Id of the SCSI target. | OctetString Constraints: range: 8-8 | .1.3.6.1.4.1.9.9.299.1.1.6.1.3 |
| ciscoExtScsiIntrDiscTgtProductIdThe product Id of the SCSI target. | OctetString Constraints: range: 16-16 | .1.3.6.1.4.1.9.9.299.1.1.6.1.4 |
| ciscoExtScsiIntrDiscTgtRevLevelThe product revision level of the SCSI target. | OctetString Constraints: range: 4-4 | .1.3.6.1.4.1.9.9.299.1.1.6.1.5 |
| ciscoExtScsiIntrDiscTgtOtherInfoThe bytes from 0 to 7 in the INQUIRY command response data. | OctetString Constraints: range: 8-8 | .1.3.6.1.4.1.9.9.299.1.1.6.1.6 |
.1.3.6.1.4.1.9.9.299.1.1.7
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk ciscoExtScsiIntrDiscLunsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-EXT-SCSI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-EXT-SCSI-MIB::ciscoExtScsiIntrDiscLunsTable'
This table is an extension to the ciscoScsiDscLunTable.
An entry (conceptual row) in this table.
Indexes
No indexes recorded
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ciscoExtScsiIntrDiscLunCapacityThe capacity of this Lun. | MBytesSNMPv2-SMIUnsigned32 Type Constraints: range: 0..4294967295 | .1.3.6.1.4.1.9.9.299.1.1.7.1.1 | ||||||||||||
| ciscoExtScsiIntrDiscLunNumberThe number of this LUN. | OctetString Constraints: range: 8-8 | .1.3.6.1.4.1.9.9.299.1.1.7.1.2 | ||||||||||||
| ciscoExtScsiIntrDiscLunSerialNumThe serial number of this LUN. | OctetString Constraints: range: 0-32 | .1.3.6.1.4.1.9.9.299.1.1.7.1.3 | ||||||||||||
| ciscoExtScsiIntrDiscLunOsThe Operating System for which this LUN was discovered. | LunDiscOS Type Values:
| .1.3.6.1.4.1.9.9.299.1.1.7.1.4 | ||||||||||||
| ciscoExtScsiIntrDiscLunPortIdThe port on which this LUN was discovered. LUNs are present on SCSI target ports. This object represents the FC-ID (Fibre Channel Identifier) of the target port on which this LUN was discovered. | CISCO-ST-TCFcAddressId Type Constraints: range: 3 | .1.3.6.1.4.1.9.9.299.1.1.7.1.5 |
.1.3.6.1.4.1.9.9.299.1.1.9
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk ciscoExtScsiPartialLunDiscTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-EXT-SCSI-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-EXT-SCSI-MIB::ciscoExtScsiPartialLunDiscTable'
This table contains a set of domain IDs on VSAN, on which the fabric-wide LUN/target discovery needs to be carried out. It is a mechanism to limit the fabric wide discovery of SCSI targets and LUNs to the domains and VSANs specified in this table. If this table is populated with some domain IDs on some VSANs and a discovery is started by setting ciscoExtScsiStartLunDisc object to 'startPartialDiscovery', then discovery of SCSI targets and LUNs is limited only to those domains on those VSANs.
An entry (conceptual row) in this table.
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ciscoExtScsiPartialLunDomIdThe Domain Id on which the lun discovery needs to be carried out. | CISCO-ST-TCDomainId Type Constraints: range: 1..239 | .1.3.6.1.4.1.9.9.299.1.1.9.1.1 | ||||||||||||
| ciscoExtScsiPartialLunRowStatusThe status of this conceptual row. | SNMPv2-TCRowStatusr/w Type Values:
Description: The RowStatus textual convention is used to manage the creation and deletion of conceptual rows, and is used as the value of the SYNTAX clause for the status column of a conceptual row (as described in Section 7.7.1 of … | .1.3.6.1.4.1.9.9.299.1.1.9.1.2 |