CISCO-ENTITY-FRU-CONTROL-MIB

        The CISCO-ENTITY-FRU-CONTROL-MIB is used to monitor
and configure operational status of 
Field Replaceable Units (FRUs) and other managable 
physical entities of the system listed in the 
Entity-MIB (RFC 2737) entPhysicalTable. 
        
FRUs include assemblies such as power supplies, fans, 
processor modules, interface modules, etc.
    

Imported Objects

ciscoMgmtCISCO-SMI
entPhysicalName, entPhysicalVendorType, entPhysicalClass, entPhysicalModelName, entPhysicalIndex, entPhysicalContainedInENTITY-MIB
InetAddress, InetAddressTypeINET-ADDRESS-MIB
SnmpAdminStringSNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUPSNMPv2-CONF
OBJECT-TYPE, Integer32, Unsigned32, NOTIFICATION-TYPE, MODULE-IDENTITYSNMPv2-SMI
TruthValue, TimeStamp, DisplayString, TEXTUAL-CONVENTIONSNMPv2-TC

Type Definitions (11)

Name Base Type Values/Constraints
CefcPercentOrMinusOnerange: -1..100
CefcVmModuleOperTypedown(1), up(2), unknown(3), goingDown(4)
FRUCoolingUnitcfm(1), watts(2)
FRUCurrentTyperange: -1000000000..1000000000
FRUTimeSeconds
ModuleAdminTypeenabled(1), disabled(2), reset(3), outOfServiceAdmin(4)
ModuleOperTypeunknown(1), ok(2), disabled(3), okButDiagFailed(4), boot(5), selfTest(6), failed(7), missing(8), mismatchWithParent(9), mismatchConfig(10), diagFailed(11), dormant(12), outOfServiceAdmin(13), outOfServiceEnvTemp(14), poweredDown(15), poweredUp(16), powerDenied(17), powerCycled(18), okButPowerOverWarning(19), okButPowerOverCritical(20), syncInProgress(21), upgrading(22), okButAuthFailed(23), mdr(24), fwMismatchFound(25), fwDownloadSuccess(26), fwDownloadFailure(27)
ModuleResetReasonTypeunknown(1), powerUp(2), parityError(3), clearConfigReset(4), manualReset(5), watchDogTimeoutReset(6), resourceOverflowReset(7), missingTaskReset(8), lowVoltageReset(9), controllerReset(10), systemReset(11), switchoverReset(12), upgradeReset(13), downgradeReset(14), cacheErrorReset(15), deviceDriverReset(16), softwareExceptionReset(17), restoreConfigReset(18), abortRevReset(19), burnBootReset(20), standbyCdHealthierReset(21), nonNativeConfigClearReset(22), memoryProtectionErrorReset(23)
PowerAdminTypeon(1), off(2), inlineAuto(3), inlineOn(4), powerCycle(5)
PowerOperTypeoffEnvOther(1), on(2), offAdmin(3), offDenied(4), offEnvPower(5), offEnvTemp(6), offEnvFan(7), failed(8), onButFanFail(9), offCooling(10), offConnectorRating(11), onButInlinePowerFail(12)
PowerRedundancyTypenotsupported(1), redundant(2), combined(3), nonRedundant(4), psRedundant(5), inPwrSrcRedundant(6), psRedundantSingleInput(7)

Objects

ciscoEntityFRUControlMIB .1.3.6.1.4.1.9.9.117
cefcMIBObjects .1.3.6.1.4.1.9.9.117.1
cefcFRUPower .1.3.6.1.4.1.9.9.117.1.1
cefcFRUPowerSupplyGroupTable .1.3.6.1.4.1.9.9.117.1.1.1
cefcFRUPowerSupplyGroupEntry
.1.3.6.1.4.1.9.9.117.1.1.1.1
cefcPowerRedundancyMode .1.3.6.1.4.1.9.9.117.1.1.1.1.1
cefcPowerUnits
.1.3.6.1.4.1.9.9.117.1.1.1.1.2
cefcTotalAvailableCurrent .1.3.6.1.4.1.9.9.117.1.1.1.1.3
cefcTotalDrawnCurrent .1.3.6.1.4.1.9.9.117.1.1.1.1.4
cefcPowerRedundancyOperMode .1.3.6.1.4.1.9.9.117.1.1.1.1.5
cefcPowerNonRedundantReason .1.3.6.1.4.1.9.9.117.1.1.1.1.6
cefcTotalDrawnInlineCurrent .1.3.6.1.4.1.9.9.117.1.1.1.1.7
cefcFRUPowerStatusTable .1.3.6.1.4.1.9.9.117.1.1.2
cefcFRUPowerStatusEntry
.1.3.6.1.4.1.9.9.117.1.1.2.1
cefcFRUPowerAdminStatus .1.3.6.1.4.1.9.9.117.1.1.2.1.1
cefcFRUPowerOperStatus .1.3.6.1.4.1.9.9.117.1.1.2.1.2
cefcFRUCurrent .1.3.6.1.4.1.9.9.117.1.1.2.1.3
cefcFRUPowerCapability .1.3.6.1.4.1.9.9.117.1.1.2.1.4
cefcFRURealTimeCurrent .1.3.6.1.4.1.9.9.117.1.1.2.1.5
cefcMaxDefaultInLinePower .1.3.6.1.4.1.9.9.117.1.1.3
cefcFRUPowerSupplyValueTable .1.3.6.1.4.1.9.9.117.1.1.4
cefcFRUPowerSupplyValueEntry
.1.3.6.1.4.1.9.9.117.1.1.4.1
cefcFRUTotalSystemCurrent .1.3.6.1.4.1.9.9.117.1.1.4.1.1
cefcFRUDrawnSystemCurrent .1.3.6.1.4.1.9.9.117.1.1.4.1.2
cefcFRUTotalInlineCurrent .1.3.6.1.4.1.9.9.117.1.1.4.1.3
cefcFRUDrawnInlineCurrent .1.3.6.1.4.1.9.9.117.1.1.4.1.4
cefcFRUActualInputCurrent .1.3.6.1.4.1.9.9.117.1.1.4.1.5
cefcFRUActualOutputCurrent .1.3.6.1.4.1.9.9.117.1.1.4.1.6
cefcMaxDefaultHighInLinePower .1.3.6.1.4.1.9.9.117.1.1.5
cefcModule .1.3.6.1.4.1.9.9.117.1.2
cefcModuleTable .1.3.6.1.4.1.9.9.117.1.2.1
cefcModuleEntry
.1.3.6.1.4.1.9.9.117.1.2.1.1
cefcModuleAdminStatus .1.3.6.1.4.1.9.9.117.1.2.1.1.1
cefcVmModuleStatusLastChangeTime
.1.3.6.1.4.1.9.9.117.1.2.1.1.10
cefcModuleOperStatus .1.3.6.1.4.1.9.9.117.1.2.1.1.2
cefcModuleResetReason .1.3.6.1.4.1.9.9.117.1.2.1.1.3
cefcModuleStatusLastChangeTime
.1.3.6.1.4.1.9.9.117.1.2.1.1.4
cefcModuleLastClearConfigTime
.1.3.6.1.4.1.9.9.117.1.2.1.1.5
cefcModuleResetReasonDescription
.1.3.6.1.4.1.9.9.117.1.2.1.1.6
cefcModuleStateChangeReasonDescr
.1.3.6.1.4.1.9.9.117.1.2.1.1.7
cefcModuleUpTime .1.3.6.1.4.1.9.9.117.1.2.1.1.8
cefcVmModuleOperStatus .1.3.6.1.4.1.9.9.117.1.2.1.1.9
cefcIntelliModuleTable .1.3.6.1.4.1.9.9.117.1.2.2
cefcIntelliModuleEntry
.1.3.6.1.4.1.9.9.117.1.2.2.1
cefcIntelliModuleIPAddrType
.1.3.6.1.4.1.9.9.117.1.2.2.1.1
cefcIntelliModuleIPAddr
.1.3.6.1.4.1.9.9.117.1.2.2.1.2
cefcModuleLocalSwitchingTable .1.3.6.1.4.1.9.9.117.1.2.3
cefcModuleLocalSwitchingEntry
.1.3.6.1.4.1.9.9.117.1.2.3.1
cefcModuleLocalSwitchingMode .1.3.6.1.4.1.9.9.117.1.2.3.1.1
cefcMIBNotificationEnables .1.3.6.1.4.1.9.9.117.1.3
cefcMIBEnableStatusNotification
.1.3.6.1.4.1.9.9.117.1.3.1
cefcEnablePSOutputChangeNotif
.1.3.6.1.4.1.9.9.117.1.3.2
cefcFRUFan .1.3.6.1.4.1.9.9.117.1.4
cefcFanTrayStatusTable .1.3.6.1.4.1.9.9.117.1.4.1
cefcFanTrayStatusEntry
.1.3.6.1.4.1.9.9.117.1.4.1.1
cefcFanTrayOperStatus .1.3.6.1.4.1.9.9.117.1.4.1.1.1
cefcFanTrayDirection .1.3.6.1.4.1.9.9.117.1.4.1.1.2
cefcFanTable .1.3.6.1.4.1.9.9.117.1.4.2
cefcFanEntry
.1.3.6.1.4.1.9.9.117.1.4.2.1
cefcFanSpeed .1.3.6.1.4.1.9.9.117.1.4.2.1.1
cefcFanSpeedPercent .1.3.6.1.4.1.9.9.117.1.4.2.1.2
cefcPhysical .1.3.6.1.4.1.9.9.117.1.5
cefcPhysicalTable .1.3.6.1.4.1.9.9.117.1.5.1
cefcPhysicalEntry
.1.3.6.1.4.1.9.9.117.1.5.1.1
cefcPhysicalStatus .1.3.6.1.4.1.9.9.117.1.5.1.1.1
cefcPowerCapacity .1.3.6.1.4.1.9.9.117.1.6
cefcPowerSupplyInputTable .1.3.6.1.4.1.9.9.117.1.6.1
cefcPowerSupplyInputEntry
.1.3.6.1.4.1.9.9.117.1.6.1.1
cefcPowerSupplyInputIndex .1.3.6.1.4.1.9.9.117.1.6.1.1.1
cefcPowerSupplyInputType .1.3.6.1.4.1.9.9.117.1.6.1.1.2
cefcPowerSupplyOutputTable .1.3.6.1.4.1.9.9.117.1.6.2
cefcPowerSupplyOutputEntry
.1.3.6.1.4.1.9.9.117.1.6.2.1
cefcPSOutputModeIndex .1.3.6.1.4.1.9.9.117.1.6.2.1.1
cefcPSOutputModeCurrent .1.3.6.1.4.1.9.9.117.1.6.2.1.2
cefcPSOutputModeInOperation
.1.3.6.1.4.1.9.9.117.1.6.2.1.3
cefcCooling .1.3.6.1.4.1.9.9.117.1.7
cefcChassisCoolingTable .1.3.6.1.4.1.9.9.117.1.7.1
cefcChassisCoolingEntry
.1.3.6.1.4.1.9.9.117.1.7.1.1
cefcChassisPerSlotCoolingCap .1.3.6.1.4.1.9.9.117.1.7.1.1.1
cefcChassisPerSlotCoolingUnit .1.3.6.1.4.1.9.9.117.1.7.1.1.2
cefcFanCoolingTable .1.3.6.1.4.1.9.9.117.1.7.2
cefcFanCoolingEntry
.1.3.6.1.4.1.9.9.117.1.7.2.1
cefcFanCoolingCapacity .1.3.6.1.4.1.9.9.117.1.7.2.1.1
cefcFanCoolingCapacityUnit .1.3.6.1.4.1.9.9.117.1.7.2.1.2
cefcModuleCoolingTable .1.3.6.1.4.1.9.9.117.1.7.3
cefcModuleCoolingEntry
.1.3.6.1.4.1.9.9.117.1.7.3.1
cefcModuleCooling .1.3.6.1.4.1.9.9.117.1.7.3.1.1
cefcModuleCoolingUnit .1.3.6.1.4.1.9.9.117.1.7.3.1.2
cefcFanCoolingCapTable .1.3.6.1.4.1.9.9.117.1.7.4
cefcFanCoolingCapEntry
.1.3.6.1.4.1.9.9.117.1.7.4.1
cefcFanCoolingCapIndex .1.3.6.1.4.1.9.9.117.1.7.4.1.1
cefcFanCoolingCapModeDescr
.1.3.6.1.4.1.9.9.117.1.7.4.1.2
cefcFanCoolingCapCapacity .1.3.6.1.4.1.9.9.117.1.7.4.1.3
cefcFanCoolingCapCurrent .1.3.6.1.4.1.9.9.117.1.7.4.1.4
cefcFanCoolingCapCapacityUnit .1.3.6.1.4.1.9.9.117.1.7.4.1.5
cefcConnector .1.3.6.1.4.1.9.9.117.1.8
cefcConnectorRatingTable .1.3.6.1.4.1.9.9.117.1.8.1
cefcConnectorRatingEntry
.1.3.6.1.4.1.9.9.117.1.8.1.1
cefcConnectorRating .1.3.6.1.4.1.9.9.117.1.8.1.1.1
cefcModulePowerConsumptionTable .1.3.6.1.4.1.9.9.117.1.8.2
cefcModulePowerConsumptionEntry
.1.3.6.1.4.1.9.9.117.1.8.2.1
cefcModulePowerConsumption .1.3.6.1.4.1.9.9.117.1.8.2.1.1
cefcFRUMIBNotificationPrefix .1.3.6.1.4.1.9.9.117.2
cefcMIBNotifications .1.3.6.1.4.1.9.9.117.2.0
cefcMIBConformance .1.3.6.1.4.1.9.9.117.3
cefcMIBCompliances .1.3.6.1.4.1.9.9.117.3.1
cefcMIBGroups .1.3.6.1.4.1.9.9.117.3.2

Notifications/Traps

NameOIDDescription
cefcModuleStatusChange


.1.3.6.1.4.1.9.9.117.2.0.1
This notification is generated when the value of
cefcModuleOperStatus changes. It can be utilized by 
an NMS to update the status of the module it is
managing.
cefcPowerStatusChange


.1.3.6.1.4.1.9.9.117.2.0.2
The cefcFRUPowerStatusChange notification indicates that
the power status of a FRU has changed. The varbind for this
notification indicates the entPhysicalIndex of the FRU,
and the new operational-status of the FRU.
cefcFRUInserted

.1.3.6.1.4.1.9.9.117.2.0.3
The cecfFRUInserted notification indicates that a FRU was
inserted. The varbind for this notification indicates the
entPhysicalIndex of the inserted FRU, and the entPhysicalIndex
of the FRU's container.
cefcFRURemoved

.1.3.6.1.4.1.9.9.117.2.0.4
The cefcFRURemoved notification indicates that a FRU was
removed. The varbind for this notification indicates the
entPhysicalIndex of the removed FRU, and the entPhysicalIndex
of the FRU's container.
cefcUnrecognizedFRU





.1.3.6.1.4.1.9.9.117.2.0.5
The cefcUnrecognizedFRU notification indicates that a FRU was
inserted whose product ID is not supported. The varbind for
this notification indicates the entPhysicalIndex of the 
inserted FRU, the entPhysicalClass this FRU belongs to, the
entPhysicalVendorType of this FRU, the entPhysicalName
of the FRU, the entPhysicalModelName of the inserted FRU, and
the cefcPhysicalStatus telling the reason code for sending this
notification.
cefcFanTrayStatusChange

.1.3.6.1.4.1.9.9.117.2.0.6
This notification is generated when the value of
cefcFanTrayOperStatus changes.
cefcPowerSupplyOutputChange



.1.3.6.1.4.1.9.9.117.2.0.7
The notification indicates that the power
supply's output capacity has changed.
          
This notification is triggered whenever one instance 
of the power supply's cefcPSOutputModeInOperation 
has transitioned from 'false' to 'true'.
cefcVmModuleStatusChangeNotif


.1.3.6.1.4.1.9.9.117.2.0.8
This notification is generated when the value of
cefcVmModuleOperStatus changes. It can be utilized by 
an NMS to update the status of the module it is
managing.