CIE1000-SYSUTIL-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
8
Rows
8
Columns
28
.1.3.6.1.4.1.9.9.832.1.24.1.2.3 · 1 row entry · 5 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilConfigTemperatureMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilConfigTemperatureMonitorTable'
Table of temperature monitor config.
cie1000SysutilConfigTemperatureMonitorEntry row .1.3.6.1.4.1.9.9.832.1.24.1.2.3.1
Each row set the sensor config.
Column Syntax OID
The identification of sensor for tempeature monitor.
CIE1000SysutilTemperatureMonitorSensorType
Type Values:
0board
1junction
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.1
The low threshold of temperature monior.
Integer32r/w
Constraints:
range: -40-125
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.2
The high threshold of temperature monior.
Integer32r/w
Constraints:
range: -40-125
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.3
The critical threshold of temperature monior.
Integer32r/w
Constraints:
range: 90-150
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.4
The value of hysteresis for temperature check.
Integer32r/w
Constraints:
range: 1-5
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.5
.1.3.6.1.4.1.9.9.832.1.24.1.3.2 · 1 row entry · 4 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilStatusPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusPowerSupplyTable'
Table of power supply status.
cie1000SysutilStatusPowerSupplyEntry row .1.3.6.1.4.1.9.9.832.1.24.1.3.2.1
Each row contains the power supply status.
Column Syntax OID
The identification of switch.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.1
The identification of power supply.
Integer32
Constraints:
range: 1-2
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.2
The state of power supply.
CIE1000SysutilPowerSupplyStateType
Type Values:
0active
1standby
2notPresent
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.3
The description of power supply.
OctetString
Constraints:
range: 0-30
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.4
.1.3.6.1.4.1.9.9.832.1.24.1.3.3 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilStatusSystemLedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusSystemLedTable'
Table of system LED status.
cie1000SysutilStatusSystemLedEntry row .1.3.6.1.4.1.9.9.832.1.24.1.3.3.1
Each row contains the system LED status.
Column Syntax OID
The identification of switch.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.1
The description of system LED status.
OctetString
Constraints:
range: 0-127
.1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.2
.1.3.6.1.4.1.9.9.832.1.24.1.3.6 · 1 row entry · 5 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilStatusTemperatureMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusTemperatureMonitorTable'
Table of temperature monitor status.
cie1000SysutilStatusTemperatureMonitorEntry row .1.3.6.1.4.1.9.9.832.1.24.1.3.6.1
Each row contains the sensor status.
Column Syntax OID
The identification of sensor for tempeature monitor.
CIE1000SysutilTemperatureMonitorSensorType
Type Values:
0board
1junction
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.1
The alarm flag of temperature low status.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.2
The alarm flag of temperature high status.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.3
The alarm flag of temperature critical status.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.4
Current temperature.
SNMPv2-SMIInteger32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.5
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1 · 1 row entry · 4 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilStatusLedStatusSystemTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusLedStatusSystemTable'
The table is the list of LED nodes. The index is the name of the LED
node
cie1000SysutilStatusLedStatusSystemEntry row .1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1
An index is a name e.g. alm
Column Syntax OID
The identification of the system LED.
CIE1000SysutilLedNameIndex
Type Values:
0alm
1dca
2dcb
3exp
4poe
5sys
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.1
Color of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) -
The led is bi-color greed red, green_amber(5) - The led is bi-color
green amber.
CIE1000SysutilLedColor
Type Values:
0off
1green
2red
3amber
4green-red
5green-amber
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.2
Type of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4)
LED is in alternative mode.
CIE1000SysutilLedMode
Type Values:
0initial
1solid
2off
3blinking
4alternative
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.3
The description of system LED status.
OctetString
Constraints:
range: 0-127
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.4
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2 · 1 row entry · 4 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilStatusLedStatusPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusLedStatusPortTable'
The table is the list of port interface LED nodes. The index is the
port interface
cie1000SysutilStatusLedStatusPortEntry row .1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1
Port interface
Column Syntax OID
Logical interface number.
CIE1000-TCCIE1000InterfaceIndex
Type Constraints:
range: 0..2147483647
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.1
Color of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) -
The led is bi-color greed red, green_amber(5) - The led is bi-color
green amber.
CIE1000SysutilLedColor
Type Values:
0off
1green
2red
3amber
4green-red
5green-amber
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.2
Type of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4)
LED is in alternative mode.
CIE1000SysutilLedMode
Type Values:
0initial
1solid
2off
3blinking
4alternative
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.3
The description of system LED status.
OctetString
Constraints:
range: 0-127
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.4
.1.3.6.1.4.1.9.9.832.1.24.1.4.1 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilControlRebootTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilControlRebootTable'
This is a table to reboot a swicth
cie1000SysutilControlRebootEntry row .1.3.6.1.4.1.9.9.832.1.24.1.4.1.1
Each switch has a set of parameters
Column Syntax OID
The identification of switch.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.1
Type of reboot. noReboot(0) does not reboot. coldReboot(1) is to do
cold reboot. warmReboot(2) is to do warm reboot, but this is optional.
The OID of vtssSysutilCapabilitiesWarmRebootSupported tells if warm
reboot is su…
CIE1000SysutilRebootTyper/w
Type Values:
0noReboot
1coldReboot
2warmReboot
3factoryReset
.1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.2
.1.3.6.1.4.1.9.9.832.1.24.1.4.2 · 1 row entry · 2 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cie1000SysutilControlSystemLedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilControlSystemLedTable'
This is a table to clear the system LED error status
cie1000SysutilControlSystemLedEntry row .1.3.6.1.4.1.9.9.832.1.24.1.4.2.1
Each switch has a set of parameters
Column Syntax OID
The identification of switch.
Integer32
Constraints:
range: 1-16
.1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.1
Type of system LED status clearing.all(0) is used to clear all error
status of the system LED and back to normal indication. fatal(1) is
used to clear fatal error status of the system LED. software(2) is used
to clear g…
CIE1000SysutilSystemLedClearTyper/w
Type Values:
0all
1fatal
2software
3post
4ztp
5stackFwChk
.1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.2