.1.3.6.1.4.1.9.9.832.1.24.1.2.3
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilConfigTemperatureMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilConfigTemperatureMonitorTable'
Table of temperature monitor config.
Each row set the sensor config.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The identification of sensor for tempeature monitor.
|
CIE1000SysutilTemperatureMonitorSensorType Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.1 |
||||
|
The low threshold of temperature monior.
|
Integer32r/w Constraints: range: -40-125 |
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.2 |
||||
|
The high threshold of temperature monior.
|
Integer32r/w Constraints: range: -40-125 |
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.3 |
||||
|
The critical threshold of temperature monior.
|
Integer32r/w Constraints: range: 90-150 |
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.4 |
||||
|
The value of hysteresis for temperature check.
|
Integer32r/w Constraints: range: 1-5 |
.1.3.6.1.4.1.9.9.832.1.24.1.2.3.1.5 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.2
·
1 row entry
·
4 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilStatusPowerSupplyTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusPowerSupplyTable'
Table of power supply status.
Each row contains the power supply status.
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
|
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.1 |
||||||
|
The identification of power supply.
|
Integer32 Constraints: range: 1-2 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.2 |
||||||
|
The state of power supply.
|
CIE1000SysutilPowerSupplyStateType Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.3 |
||||||
|
The description of power supply.
|
OctetString Constraints: range: 0-30 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.2.1.4 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.3
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilStatusSystemLedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusSystemLedTable'
Table of system LED status.
Each row contains the system LED status.
| Column | Syntax | OID |
|---|---|---|
|
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.1 |
|
The description of system LED status.
|
OctetString Constraints: range: 0-127 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.3.1.2 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.6
·
1 row entry
·
5 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilStatusTemperatureMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusTemperatureMonitorTable'
Table of temperature monitor status.
Each row contains the sensor status.
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
|
The identification of sensor for tempeature monitor.
|
CIE1000SysutilTemperatureMonitorSensorType Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.1 |
||||
|
The alarm flag of temperature low status.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.2 |
||||
|
The alarm flag of temperature high status.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.3 |
||||
|
The alarm flag of temperature critical status.
|
SNMPv2-TCTruthValue Type Values:
Description: Represents a boolean value. |
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.4 |
||||
|
Current temperature.
|
SNMPv2-SMIInteger32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.6.1.5 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1
·
1 row entry
·
4 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilStatusLedStatusSystemTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusLedStatusSystemTable'
The table is the list of LED nodes. The index is the name of the LED node
An index is a name e.g. alm
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The identification of the system LED.
|
CIE1000SysutilLedNameIndex Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.1 |
||||||||||||
|
Color of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) - The led is bi-color greed red, green_amber(5) - The led is bi-color green amber. |
CIE1000SysutilLedColor Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.2 |
||||||||||||
|
Type of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4) LED is in alternative mode. |
CIE1000SysutilLedMode Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.3 |
||||||||||||
|
The description of system LED status.
|
OctetString Constraints: range: 0-127 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.1.1.4 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2
·
1 row entry
·
4 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilStatusLedStatusPortTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilStatusLedStatusPortTable'
The table is the list of port interface LED nodes. The index is the port interface
Port interface
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Logical interface number.
|
CIE1000-TCCIE1000InterfaceIndex Type Constraints: range: 0..2147483647 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.1 |
||||||||||||
|
Color of LED. off(0) - The led is off, green(1) - The led is green,
red(2) - The led is red, amber(3) - The led is amber, green_red(4) - The led is bi-color greed red, green_amber(5) - The led is bi-color green amber. |
CIE1000SysutilLedColor Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.2 |
||||||||||||
|
Type of LED mode.initial(0) Initial state. solid(1) LED is solid
on.off(2) LED is turned off.blinking(3) LED is blinking.alternative(4) LED is in alternative mode. |
CIE1000SysutilLedMode Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.3 |
||||||||||||
|
The description of system LED status.
|
OctetString Constraints: range: 0-127 |
.1.3.6.1.4.1.9.9.832.1.24.1.3.7.2.1.4 |
.1.3.6.1.4.1.9.9.832.1.24.1.4.1
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilControlRebootTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilControlRebootTable'
This is a table to reboot a swicth
Each switch has a set of parameters
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.1 |
||||||||
|
Type of reboot. noReboot(0) does not reboot. coldReboot(1) is to do
cold reboot. warmReboot(2) is to do warm reboot, but this is optional. The OID of vtssSysutilCapabilitiesWarmRebootSupported tells if warm reboot is su… |
CIE1000SysutilRebootTyper/w Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.4.1.1.2 |
.1.3.6.1.4.1.9.9.832.1.24.1.4.2
·
1 row entry
·
2 columns
Uses the cisco variant from
Command help
/opt/observium/mibs/cisco.
Walk cie1000SysutilControlSystemLedTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIE1000-SYSUTIL-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIE1000-SYSUTIL-MIB::cie1000SysutilControlSystemLedTable'
This is a table to clear the system LED error status
Each switch has a set of parameters
| Column | Syntax | OID | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
The identification of switch.
|
Integer32 Constraints: range: 1-16 |
.1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.1 |
||||||||||||
|
Type of system LED status clearing.all(0) is used to clear all error
status of the system LED and back to normal indication. fatal(1) is used to clear fatal error status of the system LED. software(2) is used to clear g… |
CIE1000SysutilSystemLedClearTyper/w Type Values:
|
.1.3.6.1.4.1.9.9.832.1.24.1.4.2.1.2 |