extSwitchMIB | CENTRECOM-MIB |
TRAP-TYPE | RFC-1215 |
sysUpTime, sysDescr | RFC1213-MIB |
Name | OID | Description |
---|---|---|
.1.3.6.1.4.1.207.8.12.2.0.10 | One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over. | |
.1.3.6.1.4.1.207.8.12.2.0.11 | One or more previously bad sources of power to this agent has come back to life without causing an agent restart. | |
.1.3.6.1.4.1.207.8.12.2.0.12 | Attached Redundant Power Supply device is indicating an alarm condition. | |
.1.3.6.1.4.1.207.8.12.2.0.13 | Attached Redundant Power Supply device is no longer indicating an alarm condition. | |
.1.3.6.1.4.1.207.8.12.2.0.6 | A overheat trap indicates that the on board tempature sensor has reported a overheat condition. System will shutdown until unit has sufficiently cooled such that operation may begin again. A cold start trap will be issued when the unit has come back on line. | |
.1.3.6.1.4.1.207.8.12.2.0.7 | A fan failed trap indicates one or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation. | |
.1.3.6.1.4.1.207.8.12.2.0.8 | A fan has transitioned out of a failure state and is now operating correctly. | |
.1.3.6.1.4.1.207.8.12.2.0.9 | A user attempted to login to console or by telnet but was refused access due to incorrect username or password |