BIANCA-BRICK-MIBSYS-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
6

sysPCMTable

table mandatory
.1.3.6.1.4.1.272.4.17.1 · 1 row entry · 6 columns
Uses the bintec variant from /opt/observium/mibs/bintec.
Command help
Walk sysPCMTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BIANCA-BRICK-MIBSYS-MIB' -M '/opt/observium/mibs/bintec:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BIANCA-BRICK-MIBSYS-MIB::sysPCMTable'
sysPCMEntry row .1.3.6.1.4.1.272.4.17.1.1
Column Syntax OID
sysPCMSlotmandatory
Integer32
Constraints:
range: 0-30
.1.3.6.1.4.1.272.4.17.1.1.1
sysPCMUnitmandatory
Identification number of the used unit.
Integer32
Constraints:
range: -1-31
.1.3.6.1.4.1.272.4.17.1.1.2
shows wether this board can supply a clock signal to the
internal PCM-Highway.
ready: this board can supply a clock signal
not_ready: this board can't supply a clock signal
Enumeration
Enumerated Values:
1ready
2not-ready
.1.3.6.1.4.1.272.4.17.1.1.3
shows the status of this board.
candidate: this board can become PCM Highway master
master: this board is PCM Highway master
Enumeration
Enumerated Values:
1candidate
2master
.1.3.6.1.4.1.272.4.17.1.1.4
Priority during PCM-Highway master election.
A small value results in high priority; the candidate with
highest priority wins the election.
Prio 128 (lowest priority) lets the PCM-Highway master
use its own clock (inst…
Integer32r/w
Constraints:
range: 0-128
.1.3.6.1.4.1.272.4.17.1.1.5
sysPCMChangesmandatory
counts how often sysPCMClockMaster has changed.
RFC1155-SMICounter
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.272.4.17.1.1.10