BAY-STACK-SFF-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
28
.1.3.6.1.4.1.45.5.29.1.2 · 1 row entry · 28 columns
Uses the nortel variant from /opt/observium/mibs/nortel.
Command help
Walk bsDdiSfpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'BAY-STACK-SFF-MIB' -M '/opt/observium/mibs/nortel:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'BAY-STACK-SFF-MIB::bsDdiSfpTable'
This table contains information about DDI SFPs.  Entries will
exist in this table only for DDI SFP ports.
bsDdiSfpEntry row .1.3.6.1.4.1.45.5.29.1.2.1
SFF interface settings.
Indexes
Column Syntax OID
Identifies the ifIndex of the SFF port.
IF-MIBInterfaceIndex
Type Constraints:
range: 1..2147483647
Description:
A unique value, greater than zero, for each interface or
interface sub-layer in the managed system. It is
recommended that values are assigned contiguously starting
from 1. The value for each interface sub-layer must …
.1.3.6.1.4.1.45.5.29.1.2.1.1
This object indicates whether the actual values read from EEPROM
internally within an implementation are already calibrated to the
appropriate units (Volts, mA, dB, etc), or whether these values
are first converted to a…
Enumeration
Enumerated Values:
1internal
2external
.1.3.6.1.4.1.45.5.29.1.2.1.2
This object indicates the measurement type used for the received
power. A value of oma(1) indicates Optical Modulation Amplitude
(OMA).
Enumeration
Enumerated Values:
1oma
2averagePower
.1.3.6.1.4.1.45.5.29.1.2.1.3
The actual temperature value, measured in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.4
The low alarm temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.5
The low warn temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.6
The high alarm temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.7
The high warn temperature threshold, measure in 1/10000 Celsius.
Integer32
Constraints:
range: -1280000-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.8
The actual voltage value, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.9
The low alarm voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.10
The low warn voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.11
The high alarm voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.12
The high warn voltage threshold, measured in 1/10000 volts.
Integer32
Constraints:
range: 0-65500
.1.3.6.1.4.1.45.5.29.1.2.1.13
The actual bias value, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.14
The low alarm bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.15
The low warn bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.16
The high alarm bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.17
The high warn bias threshold, measured in 1/10000 mA.
Integer32
Constraints:
range: 0-1280000
.1.3.6.1.4.1.45.5.29.1.2.1.18
The actual transmit power value, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.19
The low alarm transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.20
The low warn transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.21
The high alarm transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.22
The high warn transmit power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.23
The actual receive power value, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.24
The low alarm receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.25
The low warn receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.26
The high alarm receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.27
The high warn receive power threshold, measured in 1/10000 dBm.
Integer32
Constraints:
range: -400000-83000
.1.3.6.1.4.1.45.5.29.1.2.1.28