is sent out when an error in the fan operation is
detected in a module.
atiStkSwMgmtDisabledTrap
.1.3.6.1.4.1.207.8.17.6.15
is sent out when a management interface is disabled due to
continuos invalid logins.
This trap is not applicable to 8300 series products.
atiStkSwTemperatureLimitTrap
.1.3.6.1.4.1.207.8.17.6.16
is send when the system temperature crosses threshold values
defined for different temperature levels,
e.g. high (warning) temperature, critical (error) temperature. Also
the threshold limit may be different depends on the model type.
atiStkSwFanOkTrap
.1.3.6.1.4.1.207.8.17.6.17
This trap is sent out when a fan become running Ok.
atiStkSwTemperatureNormalTrap
.1.3.6.1.4.1.207.8.17.6.18
is sent out when it is generated when system temperature
become normal.
atiStkSwHighRateStormDetectedTrap
.1.3.6.1.4.1.207.8.17.6.19
is sent out when Storm Detection function detects a received
packets rate is over the configured high rate threshold.
atiStkSwTemperatureAbnormalTrap
.1.3.6.1.4.1.207.8.17.6.2
is sent out when the temperature of a module
becomes abnormal.
atiStkSwWarningHighRateStormBlockedTrap
.1.3.6.1.4.1.207.8.17.6.20
is sent out when Storm Detection function blocks a port with
over a received packets high rate threshold.
atiStkSwRecoverHighRateStormBlockedTrap
.1.3.6.1.4.1.207.8.17.6.21
is sent out when Storm Detection function gets a blocked
port back to normal.
atiStkSwLowRateStormDetectedTrap
.1.3.6.1.4.1.207.8.17.6.22
is sent out when Storm Detection function detects a received
packets rate is over the configured row rate threshold.
atiStkSwWarningLowRateStormBlockedTrap
.1.3.6.1.4.1.207.8.17.6.23
is sent out when Storm Detection function blocks a port with
over a received packets low rate threshold.
atiStkSwRecoverLowRateStormBlockedTrap
.1.3.6.1.4.1.207.8.17.6.24
is sent out when Storm Detection function gets a blocked
port back to normal.
atiStkSwStackTopologyChangeTrap
.1.3.6.1.4.1.207.8.17.6.25
is sent out when there is a topology change in the stack.
Either one or more stack member is added or deleted.
atiStkSwBPDUGuardIsTriggeredTrap
.1.3.6.1.4.1.207.8.17.6.26
is sent out when a BPDU guard detects a spoofed BPDU
entering the STP system thru the edge port. The BPDU guard will disable
the port and notify the system administrator.
atiStkSwLoopDetectedTrap
.1.3.6.1.4.1.207.8.17.6.27
This trap is sent out when the switch detects a loop by receivig LDF packet.
atiStkSwWarningLoopBlockedTrap
.1.3.6.1.4.1.207.8.17.6.28
This trap is sent out when Loop Detection function blocks a port.
atiStkSwRecoverLoopBlockedTrap
.1.3.6.1.4.1.207.8.17.6.29
is sent out when Loop Detection function gets a blocked
port back to normal.
atiStkSwIntrusionDetectionTrap
.1.3.6.1.4.1.207.8.17.6.3
is sent out when an intrusion is detected on a port
in the switch and the port security has been configured to
send traps. It includes the mac address and vlan.
atiStkSwDOSTrap
.1.3.6.1.4.1.207.8.17.6.4
is sent out when DOS (Denial of Service) attack is detected
on a port in the switch and the port security has been configured to
send traps.
This trap is not applicable to 8300 series products.
atiStkSwSTPPortStateChangeTrap
.1.3.6.1.4.1.207.8.17.6.5
is sent out when STP port state changes due to RSTP/MSTP
topology changes in the switch.
This trap is not applicable to 8300 series products.
atiStkSwSTPTrunkStateChangeTrap
.1.3.6.1.4.1.207.8.17.6.6
is sent out when STP trunk state changes due to RSTP/MSTP
topology changes in the switch.
This trap is not applicable to 8300 series products.
atiStkSwSysRPSStateChangedTrap
.1.3.6.1.4.1.207.8.17.6.7
is sent out when the RPS(redundant Power Supply)
changes state in the switch.
Please read the description of the notification objects
and their states 'AtiStkSwSysProductInfoEntry' above.
This trap is not applicable to 8300 series products.